• Title/Summary/Keyword: lower-half

Search Result 1,310, Processing Time 0.026 seconds

A Study on the Radiation Dose of $^{131}I$ in the Thyroid Gland during the Treatment of Hyperthyroidism (갑상선 기능항진증의 $^{131}I$ 치료시 갑상선 조사량에 관한 연구)

  • Suh, Hwan-Jo;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.9 no.1
    • /
    • pp.59-71
    • /
    • 1975
  • 53 patients with hyperthyroidism have been analyzed with special reference to therapeutic response to radioactive iodine ($^{131}I$) treatment. Mean effective half-life, 24 hour uptake rate and radiation dose of $^{131}I$ in hyperthyroid patients included in this study were respectively. 1. Mean effective half-life of $^{131}I\;was\;4.7{\pm}1.5$ days in the tracer dose and $5.0{\pm}1.5$ days in the therapeutic dose. 2. Mean 24 hour uptake rate of $^{131}I\;was\;72.7{\pm}11.1%$ in the tracer dose and $73.4{\pm}12.3%$ in the theapeutic dose. 3. Mean radiation dose of $^{131}I\;was\;5,319{\pm}2,648$ RAD as predicted and $5,692{\pm}2,843$ RAD as actual. A single dose of radioactive iodine treatment was satisfactory in 34 patients (radioiodine sensitive) and multiple doses of radioactive iodine treatments were required in 19 patients (radioiodine resistant). A radioiodine resistant group of patients with hyperthyroidism was distinctively characteristic in the following aspects. 1. Mean thyroid weight calculated in the resistant group ($63.9{\pm}14.0gm$) was significantly (p<0.01) greater than that of the sensitive group ($46.6{\pm}13.3gm$). 2. Mean 24 hour uptake rate of the tracer dose in the resistant group ($67.3{\pm}10.7%$) was significantly (p<0.01) lower than that of the sensitive group ($75.7{\pm}10.5%$). 3. Mean 24 hour uptake rate of the therapeutic dose in the resistant group ($68.5{\pm}13.7%$) was significantly (p<0.05) lower than that of the sensitive group ($76.1{\pm}10.9%$). 4. Mean predicted radiation dose, of $^{131}I$ in the resistant group ($3,684{\pm}1,745$ RAD) was significantly (p<0.01) lower than that of the sensitive group ($6,232{\pm}2,683$ RAD). 5. Mean actual radiation dose of $^{131}I$ in the resistant group ($4,100{\pm}1,691$ RAD) was significantly (p<0.01) lower than that of the sensitive group ($6,582{\pm}3,024$ RAD). 6. No significant difference was detected in terms of effective half-life of $^{131}I$ among the groups (p>0.05). 7. The average mean % difference of effective half-life, uptake rate and radiation dose measured following the tracer and therapeutic dose of $^{131}I$ were not statistically significant (p>0.05). Therefore effective half-life, uptake rate and radiation dose of the therapeutic dose of $^{131}I$ were readily predictable following the tracer dose of $^{131}I$. 8. It is concluded that the possibility of resistance to radioactive iodine treatment may be anticipated in patients with thyroid gland large in size and compromised $^{131}I$ uptake rate.

  • PDF

Compact Antenna Design for the UWB Lower Half-Band WVAN Gbps Data-Rate Transceiver (UWB 하반 대역 WVAN Gbps 데이터 전송률 트랜시버용 소형 광대역 안테나의 설계)

  • Eom, Da-Jeong;Lim, Dong-Jin;Kahng, Sung-Tek;Lee, Seung-Sik;Choi, Sang-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.283-291
    • /
    • 2012
  • In this paper, a compact antenna is designed for the UWB lower half-band WVAN Gbps data-rate transceiver. The proposed antenna broadens the bandwidth less than -10 dB by placing the ring stubs and an open stub on the rectangular monopole above the partial ground and creating multiple resonant current paths. The designed antenna goes through the electromagnetic simulation and is fabricated and the implemented antenna has the characteristics of the return loss lower than -10 dB, the antenna gain greater than 5 dBi, and the efficiency over 80 % in the UWB lower half-band ranging from 3.197 GHz to 4.732 GHz. Therefore, it is thought that the proposed antenna is suitable for the size-reduced and excellently performing wireless communication transceiver.

A Study on the Characteristics of Cylinder Wake Placed in Thermally Stratified Flow(II)(Par II. Turbulent Characteristics of Stratified Wake) (열성층유동장에 놓인 원주후류의 특성에 대한 연구(2)(Part 2. 성층후류의 난류유동특성))

  • 김경천;정양범;강동구
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1322-1329
    • /
    • 1994
  • The effect of thermal stratification on the stratified flow past a circular cylinder was examined in a wind tunnel. Turbulent intensities, the rms values of temperature and turbulent convective heat flux as well as the velocity and temperature profiles in the cylinder wake with a strong thermal gradient of $200^{\circ}C/m$ were measured by using a hot-wire and cold-wire combination probe. It is found that the temperature field affects as an active contaminant, so that the vertical growth of vortical structure is suppressed and the strouhal number decreases with increasing the extent of stratification. And also, the wake structure can not sustain their symmetricity about the wake centerline and vertical turbulent motion dissipates faster than that of the neutral case when such a strong thermal gradient is superimposed. It is evident that the turbulent mixing in the upper half section is stronger than that of the lower of the wake in a stably stratified flow because the turbulent intensities and convective heat flux in the upper half section are larger than those of the lower half of the wake.

First-principles Study on the Half-metallicity and Magnetism of a Full Heusler Alloy, Co2HfSi, in Bulk State and at its (001) Surfaces

  • Jin, Ying-Jiu;Lee, Jae-Il
    • Journal of Magnetics
    • /
    • v.13 no.4
    • /
    • pp.115-119
    • /
    • 2008
  • The authors predicted that $Co_2HfSi$, a $Co_2$-based full Heusler alloy, is being a half-metallic ferromagnet by first-principles calculations using the all electron full-potential linearized augmented plane wave method which adopts the generalized gradient approximation. The integer value of the calculated total magnetic moment of 2.00 ${\mu}_B$ per formula unit and a spin gap of 0.69 eV in spin down state confirmed the half-metallicity of bulk $Co_2HfSi$. For the $Co_2HfSi$(001) surface, we considered two possible surface terminations, namely, Co terminated and HfSi terminated surfaces. It was found that half-metallicity was retained at the HfSi-terminated surface but not at the Co-terminated surface. The magnetic moment of surface Co atoms in the Co-terminated surface was slightly lower than that of Co atoms in deep inner-layers, whereas the magnetic moments of Hf and Si atoms at the HfSi-terminated surface were almost same as those in deep inner-layers.

Design of a Robust Half-bridge Driver IC to a Variation of Process and Power Supply (공정 및 공급전압 변화에 강인한 하프브리지 구동 IC의 설계)

  • Song, Ki-Nam;Kim, Hyoung-Woo;Kim, Ki-Hyun;Seo, Kil-Soo;Jang, Kyung-Oun;Han, Seok-Bung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.801-807
    • /
    • 2009
  • In this paper, we propose a novel shoot-through protection circuit and pulse generator for half-bridge driver IC. We designed a robust half-bridge driver IC over a variation of processes and power supplies. The proposed circuit is composed a delay circuit using a beta-multiplier reference. The proposed circuit has a lower variation rate of dead time and pulse-width over variation of processes and supply voltages than the conventional circuit. Especially, the proposed circuit has more excellent pulse-width matching of set and reset signals than the conventional circuit. Also, the proposed pulse generator is prevented from fault operations using a logic gate. Dead time and pulse-width of the proposed circuit are typical 250 ns, respectively. The variation ratio is 68%(170 ns) of maximum over variation of processes and supply voltages. The proposed circuit is designed using $1\;{\mu}m$ 650 V BCD (Bipolar, CMOS, DMOS) process parameter, and the simulations are carried out using Spectre simulator of Cadence corporation.

Eight and a Half Syndrome: A Clinical Study of 2 Cases (8과 1/2 증후군 2례)

  • Park, Ji-Min;Kim, Jong-Han;Yoo, Je-Hyuk;Yoon, Ga-Young;Nam, Dong-Woo;Lee, Sang-Hoon;Kim, Jong-In
    • Journal of Acupuncture Research
    • /
    • v.29 no.3
    • /
    • pp.139-148
    • /
    • 2012
  • Objectives : The purpose of this case is to report the improvement of two patients diagnosed with eight and a half syndrome after combination therapy of oriental and western medicine. Methods : We treated the patients with combination therapy of oriental and western medicine such as acupuncture, moxibustion, herbal medication, antithrombotic agents and steroid therapy. Changes of peripheral facial paralysis were evaluated using House-Brackmann facial grading system and the degree of dizziness, tenderness and pain of upper abdomen were assessed using numerous rating scale. Changes in motor grade of upper and lower extremities were evaluated using medical research council scale. Results : We have recently experienced two cases of eight and a half syndrome - a syndrome characterized by the coexistence of one and a half syndrome, a rare ophthalmoparetic syndrome characterized by a conjugate horizontal gaze palsy in one direction and an internuclear ophthalmoplegia in the other, and cranial nerve VII palsy. The one and a half syndrome was caused by acute cerebral infarction. Two patients in this report were improved through combination therapy of oriental and western medicine. Conclusions : We report the clinical course and treatment methods of eight and a half syndrome.

A Study on Natural Vibration Characteristics of Dome Structure According to Natural Frequency Ratio of Substructure (하부 구조의 고유 진동수비에 따른 돔 구조의 고유 진동 특성에 관한 연구)

  • Park, Kwang-Seob;Kim, Yun-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.75-82
    • /
    • 2018
  • Large space structures exhibit different natural vibration characteristics depending on the aspect ratio of structures such as half-open angle. In addition, since the actual large space structure is mostly supported by the lower structure, it is expected that the natural vibration characteristics of the upper structure and the entire structure will vary depending on the lower structure. Therefore, in this study, the natural vibration characteristics of the dome structure are analyzed according to the natural frequency ratio by controlling the stiffness of the substructure. As the natural frequency of the substructure increases, the natural frequency of the whole structure increases similarly to the natural frequency of the upper structure. Vertical vibration modes dominate at $30^{\circ}$ and $45^{\circ}$, and horizontal vibration modes dominate at $60^{\circ}$ and $90^{\circ}$.

A New Broadband Microstrip-to-SIW Transition Using Parallel HMSIW

  • Cho, Dae-Keun;Lee, Hai-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.2
    • /
    • pp.171-175
    • /
    • 2012
  • In this work, a new microstrip-to-substrate integrated waveguide (SIW) transition using the parallel half-mode substrate integrated waveguide (HMSIW) is proposed. The proposed transition consists of three sections : a microstrip, parallel HMSIWs, and an SIW. By inserting the parallel HMSIWs section between the microstrip section and the SIW section, the proposed transition can improve the return loss characteristics of the near cut-off frequency because the HMSIWs section has a lower cut-off frequency than the SIW section (8.6 GHz). The lower cut-off frequency is achieved through gradual electromagnetic field mode changes for a low reflection. The measured return loss is less than 20 dB in the of 9.1~16.28 GHz freqeuncy range for the back-to-back transition. The measured insertion loss is within 1.6 dB for the back-to-back transition. The proposed transition is expected to play an important role in wideband SIW circuits fed by a microstrip.

Development of Battery Charger for Electric Vehicle using the LLC Resonant Converter (LLC 공진형 컨버터를 적용한 전기자동차 고압배터리 충전기 개발)

  • Kim, Gyoung-Man;Yoo, Jong-Uk;Kim, Tae-Kwon;Kang, Chan-Ho;Chun, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.443-447
    • /
    • 2013
  • This paper deals with LLC resonant converter of on-board charger for electric vehicle charging. Generally, the on-board charger must have a very widely charging voltage, higher efficiency, higher power factor, lower volume and lower weight. For reducing the switching losses, voltage and current stress of the device, the on-board charger is apply the half-bridge LLC resonant converter topology. To have a wide voltage range, it is design the hardware parameters and determine the switching frequency range of the LLC resonant converter. The experimental results show a wide charge voltage.

Measurement and Analysis of Pediatric Patient Exposure Dose Using Glass dosimeter and a PC-Based Monte Carlo Program (Glass dosimeter와 PCXMC Program을 이용한 소아피폭선량 측정 및 분석)

  • Kim, Young-Eun;Lee, Jeong-Hwa;Hong, Sun-Suk;Lee, Kwan-Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.9-14
    • /
    • 2012
  • Exposed dose of young child should be managed necessarily. Young child is more sensitive than adult of a Radioactivity, especially, and lives longer than adult. Must reduce exposed dose which follows The ALARA(As Low As Reasonably Achievable)rule is recommended by ICRP(International Commission on Radiological Protection)within diagnostic useful range. Therefore, We have to prepare Pediatric DRL(Diagnostic Reference Level) in Korea as soon as possible. Consequently, in this study, wish to estimate organ dose and effective dose using PCXMC Program(a PC-Based Monte Carlo Program), and measure ESD(Entrance surface dose)and organ dose using Glass dosimeter, and then compare with DRL which follows EC(European Commission)and NRPB(National Radiological Protection Board). Using glass dosimeter and PCXMC programs conforming to the International Committee for Radioactivity Prevention(ICRP)-103 tissue weighting factor based on the item before the organs contained in the Chest, Skull, Pelvis, Abdomen in the organ doses and effective dose and dose measurements were evaluated convenience. In a straightforward way to RANDO phantom inserted glass dosimeter(GD352M)by using the hospital pediatric protocol, and in a indirect way was PCXMC the program through a virtual simulation of organ doses and effective dose were calculated. The ESD in Chest PA is 0.076mGy which is slightly higher than the DRL of NRPB(UK) is 0.07mGy, and is lower than the DRL of EC(Europe) which is 0.1mGy. The ESD in Chest Lateral is 0.130mGy which is lower than the DRL of EC(Europe) is 0.2mGy. The ESD in Skull PA is 0.423mGy which is 40 percent lower than the DRL of NRPB(UK) is 1.1mGy and is 28 percent lower than the DRL of EC(Europe) is 1.5mGy. The ESD in Skull Lateral is 0.478mGy which is half than the DRL of NRPB(UK) is 0.8mGy, is 40 percent lower than the DRL of EC(Europe) is 1mGy. The ESD in Pelvis AP is 0.293mGy which is half than the DRL of NRPB(UK) is 0.60mGy, is 30 percent lower than the DRL of EC(Europe)is 0.9mGy. Finally, the ESD in Abdomen AP is 0.223mGy which is half than the DRL of NRPB(UK) is 0.5mGy, and is 20 percent lower than the DRL of EC is 1.0mGy. The six kind of diagnostic radiological examination is generally lower than the DRL of NRPB(UK)and EC(Europe) except for Chest PA. Shouldn't overlook the age, body, other factors. Radiological technician must realize organ dose, effective dose, ESD when examining young child in hospital. That's why young child is more sensitive than adult of a Radioactivity.

  • PDF