• Title/Summary/Keyword: low-solidity

Search Result 28, Processing Time 0.029 seconds

Effect of Air Content on the Heat Transfer Characteristics of Nonwoven Insulating Materials (부직포내 공기함량이 열전달에 미치는 영향)

  • 김희숙;김은애
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.2
    • /
    • pp.244-251
    • /
    • 1994
  • The purpose of this study was to analyze conductive convective and radiative heat transfer characteristic of the nonwovens were studied by measuring thermal conductance at atmospheric and low air pressure. The results obtained were as follows . 1) As thickness of air layer Increased, overall heat transfer was decreased by reducing conductive and radiative heat trasfer. 2) The conductive and convective heat trasfer by air were in the range of 79~8971 of overall heat transfer. 3) As thickness of nonwoven increased for a given solidity, overall heat trasfer was decresed by increasing total thickness of air layer and by reducing conductive and radiative heat transfer. 4) For a given weight, increasing thickness is more effective than increasing solidity.

  • PDF

Performance Analysis of a Centrifugal Compressor for HFC-134a with Variation of Diffuser Vane Angle (디퓨저 베인 설치각 변화에 따른 R134a 원심압축기 성능 분석)

  • Park, Han-Young;Shin, You-Hwan;Lee, Yoon-Pyo;Kim, Kwang-Ho;Chung, Jin-Taek;Cho, Yong-Hun;Kim, Jong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2823-2828
    • /
    • 2007
  • Numerical simulation on the two-stage centrifugal compressor with Low Solidity Vaned Diffuser LSVD) for HFC-134a Turbo-chiller was performed using a commercial code. The comparative study with experimental results from other compressor was also investigated to testify the simulation schemes. The numerical analysis was separately simulated for each stage of the compressor and the effect of impeller-diffuser flow interaction was considered. Setting angle of the diffuser vane changed in the range of 15 deg. and the effects on its variation were discussed in detail including the flow analysis in the passage of the compressor. The vane setting angle obtained from the preliminary design was slightly adjusted to the optimal value by the performance enhancement in terms of pressure recovery and flow characteristics.

  • PDF

Chaotic vibration characteristics of Vertical Axis Wind Turbine (VAWT) shaft system

  • C.B. Maheswaran;R. Gopal;V.K. Chandrasekar;S. Nadaraja Pillai
    • Wind and Structures
    • /
    • v.36 no.3
    • /
    • pp.215-220
    • /
    • 2023
  • We study the progressive full-scale wind tunnel tests on a high solidity vertical axis wind turbine (VAWT) for various tip speeds and pitch angles to understand the VAWT shaft system's dynamics using 0-1 Test for chaos. We identify that while varying rotor speed (tip speed) of the turbine, the system's dynamics change from periodic to chaotic through quasiperiodic and strange non-chaotic (SNA) states. The present study is the first experimental evidence for the existence of these states in the VAWT shaft system to the best of our knowledge. Using the asymptotic growth value Kc in 0-1 test, when the turbine operates at the low tip speeds and high pitch angles for low incoming wind speeds, the system behaves periodic (Kc ≈ 0). However, when the incoming wind speed increases further the system's dynamics shift from periodic to chaotic vibrations through quasi-periodic and SNA. This phenomenon is due to the dynamic stalling of blades which induces chaotic vibration in the VAWT shaft system. Further, the singular continuous spectrum method validates the presence of SNA and differentiates the SNA from chaotic vibrations.

Analysis of impeller exit condition using a modified Stanitz equation in a centrifugal refrigerant compressor (예측수정된 Stanitz 방정식을 이용한 임펠러 출구 조건 해석)

  • Jeong, J.;Kim, C.D.;Lee, H.K.;Lee, Y.D.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.61-68
    • /
    • 1999
  • We have measured pressure distributions within the diffuser and pressures at the inlet and outlet of the compressor in orde to match impeller and low-solidity diffuser of 500RT centrifugal refrigerant-compressor which has been developed in LG Cable Ltd. Modified Stanitz equation is used to predict the measured data by tuning several parameters and then is validated. Using the validated parameters and modified Stanitz equation, we have obtained data necessary to design the diffuser.

  • PDF

Experimental Study on the Performance Characteristics of the Diffuser as a Relation of the Variation of Vane Turning Angle (베인 회전각의 변화에 따른 디퓨저의 성능특성에 관한 실험적 연구)

  • Cho, Sung-Kook;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.2 s.3
    • /
    • pp.74-80
    • /
    • 1999
  • Recently, impressive gains of performance and efficiency with apparently little or no loss in flow range have been seen with the use of LSVD(Low Solidity Vaned Diffuser) over vaneless diffuser. Experiments of the effects of the vane turning angle variations(positive, negative, zero), with the other design parameters fixed, on the performance and flow range were carried out. Diffusers with a zero turning angle have the best characteristics in terms of performance and efficiency and the FFT results show different frequency characteristics due to vane turning angles in low flow range.

  • PDF

Experimental study on the performance characteristics of the diffuser due to the variation of vane angle (베인각도의 변화에 따른 디퓨저의 성능특성에 관한 실험적 연구)

  • Cho, S. K.;Kang, S. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.142-148
    • /
    • 1998
  • Recently for the impressive gains of performance and efficiency over vaneless diffuser with apparently little or no loss in flow range, the use of LSVD(Low Solidity Vaned Diffuser) is well recommended. The experiments on the effect of the vane turning angle variation(positive, negative, zero) with other design parameters fixed on the performance and flow range were carried out. Diffuser with zero turning angle has the best characteristics in terms of performance and efficiency and The FFT results show the different frequency characteristics due to the vane turning angle in low flow range.

  • PDF

Development of the Turbo Compressor for a Geothermal Heat-Pump System (지열 히트 펌프시스템용 터보 압축기 개발)

  • Park, Jun-Young;Park, Moo-Ryong;Choi, Sang-Gu;Yoon, Eui-Soo;Hwang, Soon-Chan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1395-1400
    • /
    • 2004
  • A centrifugal compressor for geothermal heat pump system using R134a as working fluid has been developed. The centrifugal compressor consists of an impeller with splitters, two vaneless diffuser, a low solidity vaned diffuser and a volute. In this compressor, diffuser blade angles are controlled to satisfy both heating and cooling conditions. A aerodynamic design was done by applying the repeating design procedure including a meanline design, a 3D geometry generation and fluid dynamic calculation. In this paper, design and performance prediction results of the compressor are presented.

  • PDF

The Research on NAUT Characteristics Evaluation by Defection Image (결함 화상화를 통한 NAUT 특성평가 연구)

  • Na, Sun-Young;Kim, Jae-Yeol
    • Tribology and Lubricants
    • /
    • v.26 no.6
    • /
    • pp.341-345
    • /
    • 2010
  • The NAUT(Non contact Air coupled Ultrasonic Testing) is one of the ultrasonic wave inspection methods. It compensates High power ultrasound Pulser Receiver, pre-amp, air probe of high sensitivity in air to generate loss energy by NAUT methods. Generally, in case of ultrasound inspection, it applies contact methods by using couplant. However it can inspect of UT without couplant by this NAUT. The ultrasound transmission reception is composed in stable condition in NAUT. It can inspect high low material or the specimen of rough part, the narrow spot, too. The spot welding is applying the inosculation of automobile component, car body, all boards. The CFRP is necessity of NDE because of the solidity changes material according to lamella tearing. Therefore it checked on realization whether and commercialization in the spot welding and CFRP inspection that the NAUT would be applied them.

Theoretical and experimental study for optimization method of particle removal fibrous filter used in ventilation system (입자 제거용 환기 필터의 설계 변수 선정 기법을 위한 이론 및 실험적 연구)

  • Jung, Yee-Kyeong;Noh, Kwang-Chul;Park, Jae-Hong;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 2009
  • Pressure drop and particle removal efficiency of two commercial fibrous medium filters were measured with 20~1,000 nm sized aerosolized KCl particles. Pressure drop and particle removal efficiency were also theoretically predicted and the results qualitatively agreed with the experimental data. For this given particle removal efficiency, a filter design method for obtaining minimum pressure drop (and therefore minimum fan power) was suggested in this study by selecting solidity and fiber diameter as parameters. Therefore, by carrying out theoretical and experimental approaches together, this paper introduced a way of finding conditions for low pressure drop and high performance of a fibrous filter, especially if the filter would be used in mechanical ventilation system.

  • PDF

An Experimental Study of Surface Pressure on a Turbine Blade in Partial Admission (분사영역과 터빈익형 위치에 따른 표면압 변화에 관한 실험적 연구)

  • Choi, Hyoung-Jun;Park, Young-Ha;Kim, Chae-Sil;Cho, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.8
    • /
    • pp.735-743
    • /
    • 2011
  • In this study, the distribution of surface pressure was measured in a steady state on a turbine blade which was moved the injected region and receded the stagnation region using a linear cascade apparatus. Axial-type blades were used and the blade chord was 200mm. The rectangular nozzle was applied and its size was $200mm{\times}200mm$. The experiment was done at $3{\times}10^5$ of Reynolds number based on the chord. The surface pressures on the blade were measured at three different nozzle angles of $58^{\circ}$, $65^{\circ}$ and $72^{\circ}$ for off-design performance test. In addition, three different solidities of 1.25, 1.38 and 1.67 were applied. From the results, the low solidity caused the low pressure on the blade suction surface at entering region and the reverse rotating force was generated at the low nozzle angle. The positive incidence also made the pressure lower on the suction surface at entering region.