• Title/Summary/Keyword: low-rise residential building

Search Result 56, Processing Time 0.025 seconds

Simulation of Changes in Nearby Thermal Environment According to Green Roof in Low-Rise Residential Area of Daegu (대구광역시 저층주거지역의 옥상녹화 조성에 따른 주변 열환경 변화 모의실험)

  • Kim, Dae-Wuk;Jung, Eung-Ho;Cha, Jae-Gyu
    • Journal of the Korean housing association
    • /
    • v.24 no.3
    • /
    • pp.45-53
    • /
    • 2013
  • It is important to secure green spaces to solve the urban heat island phenomenon, which is among problems resulted by high-density developments in metropolitan areas. However, it is hard to secure such green spaces in established urban areas so Green Rooftop development approaches have recently been highlighted and introduced as a solution to the situation. The present study conducts a simulation on residential areas in urbanized regions to quantitatively evaluate the effects of green rooftop developments through a comparison of changes in the air temperatures before and after relevant development projects. According to the evaluation results, when the green roof top development is conducted in the available areas, the temperature is reduced by 0.14 degree. The extension of green project to the entire building showed the reduction of the temperature by 0.29 degree. Based on these results, it can be concluded that the green rooftop development is a practically solution for reducing the air temperature of urbanized areas.

A Study on the POE (Post Occupancy Evaluation) according to the Residential Environment of Mixed-use Apartment Complexes In Seoul

  • Ha, Man Joon
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.2
    • /
    • pp.197-212
    • /
    • 2020
  • In this study, POE(Post Occupancy Evaluation) evaluation indexes were selected into six categories through the consideration of theories and prior research. Therefore, qualitative supply can be achieved through POE according to the aspect of residential environment after the quantitative supply of mixed-use apartment complex by the population concentration in Seoul due to industrialization and urbanization. As the evaluation elements, detailed survey contents were selected for livability, convenience, comfort, safety, economy, and sociality. Based on the survey contents, six elements were evaluated and analyzed using Data coding and Likert scale after surveying 12 complexes (Urban areas and non-urban areas) in Seoul. As a result of the study, six categories selected as the POE showed that importance of quality of life and safety was developed in high recognition according to high satisfaction with convenience and safety. Sociality showed the lowest satisfaction in the following order : livability, comfort, economy and sociality. Residents' sense of community, interaction with neighborhood, etc., showed low satisfaction, and it seems that it is necessary to improve and supplement the system for the development of mixed-use apartment complex in the future. The detailed characteristics of livability showed high satisfaction of the living room, the front door and the main room which are main uses of housing, and low satisfaction in storage size. The analysis of convenience is that convenient public transportation was the highest, and educational environment and additional facilities were the lowest, showing the advantages and disadvantages of location characteristics. As a result of the analysis of comfort, satisfaction with the landscape area was low and it seems that green space is needed for the development of mixed-use apartment complex in the future. Lastly, regarding the safety, the satisfaction of the access control, the location of security office, etc. were high, however separation of circulation was low. Therefore, it is necessary to clearly separate the circulation between the residence and other facilities in the mixed-use apartment complex.

An Analysis of the Relationship Between Resettlement and Housing Redevelopment Characteristics (주택재개발사업 특성이 재입주에 미치는 영향)

  • Ko Duk Kyun;Kim Hong-Kyu
    • Journal of the Korean housing association
    • /
    • v.16 no.3
    • /
    • pp.101-107
    • /
    • 2005
  • The reason that compulsory removals of a low-quality housing redevelopment such as involuntary or unintentional migration present a problem for urban communities is that whether involuntary movers adapt themselves to their new home has an influence on the urban communities that surround them. Moreover, involuntary emigrants have higher probability of choosing faulty residential areas than voluntary emigrants do. This gives rise to a problem of another residential migration for involuntary movers. In order to solve these problems, there is a need for a new housing policy that enables original residents to come back to their old community. However studies for resettlement had not conducted subjects about housing redevelopment characteristics which influences the involuntary movers directly. Instead personal microscopic characteristics such as statistics of resettlement, the moving distance, the reason of moving, improvement of living environment, had been main subjects of farmer studies. So the purpose of this study is to analyze an analysis of the relationship between resettlement and housing redevelopment characteristics. The data used in this study was obtained at 47 areas designated by Seoul (metropolis) since 1990 for redevelopment. Cluster Analysis Is used for dividing high rate of resettlement with low rate of resettlement and Regression Analysis is used for the analysis of the relationship between resettlement and housing redevelopment characteristics. The results of examining the effects of a redeveloped housing complex on returning residents at 47 areas designated by Seoul (metropolis) since 1990 fur redevelopment are as follows: First, A housing complex with a high returning rate (remove-in rate?) has no state/public land, unauthorized building owners who are in the low-income brackets, and few interested parties such as union members. This is the characteristic of a redeveloped housing complex with a short-period project span. On the contrary, a housing complex that has a low returning rate is crowded by state/public land, and numerous unauthorized building owners, and interested parties. Second, According to the linear regression analysis, among the factors that affect returning residents, 'physical properties(characteristics) of a region', 'population properties within a region', and 'properties of a project span' indicate a negative(-)influence whereas 'properties of a complex density' shows a positive(+) influence. In a nutshell, the more the physical properties, population properties, projectspan properties, the lower the returning rate and the more the complex density properties, the higher the returning rate. In detail, an area with many small land and new/large buildings, a high population, and a long project duration has a low returning rate of original residents while an area holding large capacity and buildings with many number of floors (multiple-storied building) has a high returning rate.

A Study on Potential of Engineered Wood for 9-story Office Buildings (공학목재의 9층 사무소 건물 적용 가능성 연구)

  • Chu, Yurim;Kim, Taewan;Kim, Seung-Rae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.163-170
    • /
    • 2017
  • The need for eco-friendly building materials such as engineered wood has increased to reduce carbon emissions. Although the range and height of engineered wood buildings are gradually increasing in North America and Europe, engineered wood is mainly used for low-rise residential buildings in Korea. In order to reduce carbon emissions more, therefore, it needs to expand the use of engineered wood by applying it to various buildings with different uses or more stories. With this background, the aim of this study is to investigate the applicability of engineered wood for 9-story office buildings. Since a 9-story building with engineered wood only is not allowed in KBC, an example building has RC ordinary shear walls as the lateral force resisting system while engineered wood is only used for gravity load resisting moment frames. Another example building is also used for comparison where both lateral and gravity load resisting systems are designed by RC. The applicability of engineered wood is investigated by comparing the seismic performance and the amount of carbon emission of both buildings. The result shows that the seismic performance of both buildings was not significantly different while the amount of carbon emission of the engineered wood building was much less then the RC building. Based on this result, engineered wood is sufficiently applicable to 9-story office buildings even though it still needs to pay attention to the shear design of reinforce concrete walls.

A Study on the Evaluating Indicators of the Level of Deterioration in High-rise and high-density Apartments (고층고밀 아파트단지의 노후도 평가지표 개발)

  • Cho, Sung-Heui;Lee, Tae-Kyung
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.131-142
    • /
    • 2009
  • High-rise and high-density apartment complexes have been built and supplied on a large scale in the 1st period of the New Town project in metropolitan areas since the late 1980s. Now It has become necessary to improve those apartment complexes, which have serious deterioration problems for aging more than about 20 years accompanying simultaneity and a large scale. The purpose of this research is to develop the evaluating indicators to measure the level of deterioration of apartments inclusively and practically in order to regenerate apartments as sustainable residential environments. This study is composed of the following four parts; (a) establishing the conceptual model of evaluation of apartment deterioration, (b) selecting evaluation items, (c) constituting evaluation measurement, and(d)weighting evaluation indicators. First, deterioration of apartments was conceptualized by physical. social, and economical aspects in terms of sustainable development and proposed the conceptual model of hierarchy structure of evaluation of apartment deterioration by literature reviews. Second, evaluating items were selected based on literature reviews of existing indicators and preceding studies about apartments of Korea and foreign countries. The evaluating indicators were identified as a total of 77 evaluating items which were composed of three dimensions and 9 attributes on the basis of the conceptual model. They cover comprehensive scope of the apartment such as unit, building, complex, and site. Third, as the measurement, the 5 point ordinal scale measure was suggested. The evaluating measurement including measure standards, measure methods, and measure contents were developed by each evaluating items. Lastly, the weighting of evaluating indicators was analyzed by AHP method conducted by survey on the expert group. Items were identified as high contributors or low contributors. The weighting of these items could suggest several evaluations according to the situation. The evaluation of the level of deterioration can be done by both total evaluation and a specific field of evaluation. In addition, it is easy to grasp deteriorated attributes or dimensions by providing a radar and bar chart showing evaluation results. These evaluating indicators could be a useful tool to grasp actual methods for the regeneration of apartments.

Effect of the Urban Land Cover Types on the Surface Temperature: Case Study of Ilsan New City (도시지역의 토지피복유형이 지표면온도에 미치는 영향: 경기도 일산 신도시를 중심으로)

  • Kim, Hyun-Ok;Yeom, Jong-Min
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.2
    • /
    • pp.203-214
    • /
    • 2012
  • The physical environment of urban areas covered mostly by concrete and asphalt is the main cause of the urban heat island effect, primarily becoming apparent through increased land surface temperature. This study examined the effect of different urban land cover types on the land surface temperature using MODIS, Landsat ETM+ and RapidEye satellite data. As a result, the remote sensing based land surface temperature showed a marked difference according to the land use pattern in the case study of Ilsan new city. The high-rise apartment residential districts with less building-to-land ratio and higher green area ratio revealed lower land surface temperature than the low-story single-family housing districts characterized by relatively high building-to-land ratio and low green area ratio. From the view of climate zone and land cover types, there is a strong linear correlation between the impervious land cover ratio and the land surface temperature; the land surface temperature increases as the impervious built-up areas expand. In contrast, vegetation;water and shadow areas affect the decrease of land surface temperature. There is also a negative (-) correlation between NDVI and land surface temperature but the seasonal variation of NDVI can be hardly corrected.

Comparison of behavior of high-rise residential buildings with and without post-tensioned transfer plate system

  • Byeonguk Ahn;Fahimeh Yavartanoo;Jang-Keun Yoon;Su-Min Kang;Seungjun Kim;Thomas H.-K. Kang
    • Computers and Concrete
    • /
    • v.31 no.4
    • /
    • pp.337-348
    • /
    • 2023
  • Shear wall is commonly used as a lateral force resisting system of concrete mid-rise and high-rise buildings, but it brings challenges in providing relatively large space throughout the building height. For this reason, the structure system where the upper structure with bearing, non-bearing and/or shear walls that sits on top of a transfer plate system supported by widely spaced columns at the lower stories is preferred in some regions, particularly in low to moderate seismic regions in Asia. A thick reinforced concrete (RC) plate has often been used as a transfer system, along with RC transfer girders; however, the RC plate becomes very thick for tall buildings. Applying the post-tensioning (PT) technique to RC plates can effectively reduce the thickness and reinforcement as an economical design method. Currently, a simplified model is used for numerical modeling of PT transfer plate, which does not consider the interaction of the plate and the upper structure. To observe the actual behavior of PT transfer plate under seismic loads, it is necessary to model whole parts of the structure and tendons to precisely include the interaction and the secondary effect of PT tendons in the results. This research evaluated the seismic behavior of shear wall-type residential buildings with PT transfer plates for the condition that PT tendons are included or excluded in the modeling. Three-dimensional finite element models were developed, which includes prestressing tendon elements, and response spectrum analyses were carried out to evaluate seismic forces. Two buildings with flat-shape and L-shape plans were considered, and design forces of shear walls and transfer columns for a system with and without PT tendons were compared. The results showed that, in some cases, excluding PT tendons from the model leads to an unrealistic estimation of the demands for shear walls sit on transfer plate and transfer columns due to excluding the secondary effect of PT tendons. Based on the results, generally, the secondary effect reduces shear force demand and axial-flexural demands of transfer columns but increases the shear force demand of shear walls. The results of this study suggested that, in addition to the effect of PT on the resistance of transfer plate, it is necessary to include PT tendons in the modeling to consider its effect on force demand.

A study of aerodynamic pressures on elevated houses

  • Abdelfatah, Nourhan;Elawady, Amal;Irwin, Peter;Chowdhury, Arindam
    • Wind and Structures
    • /
    • v.31 no.4
    • /
    • pp.335-350
    • /
    • 2020
  • In coastal residential communities, especially along the coastline, flooding is a frequent natural hazard that impacts the area. To reduce the adverse effects of flooding, it is recommended to elevate coastal buildings to a certain safe level. However, post storm damage assessment has revealed severe damages sustained by elevated buildings' components such as roofs, walls, and floors. By elevating a structure and creating air gap underneath the floor, the wind velocity increases and the aerodynamics change. This results in varying wind loading and pressure distribution that are different from their slab on grade counterparts. To fill the current knowledge gap, a large-scale aerodynamic wind testing was conducted at the Wall of Wind experimental facility to evaluate the wind pressure distribution over the surfaces of a low-rise gable roof single-story elevated house. The study considered three different stilt heights. This paper presents the observed changes in local and area averaged peak pressure coefficients for the building surfaces of the studied cases. The aerodynamics of the elevated structures are explained. Comparisons are done with ASCE 7-16 and AS/NZS 1170.2 wind loading standards. For the floor surface, the study suggests a wind pressure zoning and pressure coefficients for each stilt height.

Seismic performance of a 10-story RC box-type wall building structure

  • Hwang, Kyung Ran;Lee, Han Seon
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1193-1219
    • /
    • 2015
  • The purpose of this study is to evaluate the seismic performance of high-rise reinforced concrete (RC) box-type wall structures commonly used for most residential buildings in Korea. For this purpose, an analytical model was calibrated with the results of the earthquake simulation tests on a 1:5 scale 10-story distorted model. This calibrated model was then transformed to a true model. The performance of the true model in terms of the stiffness, strength, and damage distribution through inelastic energy dissipation was observed with reference to the earthquake simulation test results. The model showed high overstrength factors ranging from 3 to 4. The existence of slab in this box-type wall system changed the main resistance mode in the wall from bending moment to tension/compression coupled moment through membrane actions, and increased the overall resistance capacity by about 25~35%, in comparison with the common design practice of neglecting the slab's existence. The flexibility of foundation, which is also commonly neglected in the engineering design, contributes to 30~50% of the roof drift in the stiff direction containing many walls. The possibility of concrete spalling and reinforcement buckling and fracture under the maximum considered earthquake (MCE) in Korea appears to be very low when compared with the case of the 2010 Concepcion, Chile earthquake.

Evaluation of Seismic Capacity and Estimation of Earthquake Damage for Existing Unreinforced Masonry Building in Korea (국내 조적조 건물의 내진성능평가 및 지진피해율 상정)

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.535-542
    • /
    • 2006
  • In Seoul, more than 80 percent of residential buildings are constructed with unreinforced masonry(URM) buildings in early 1970 to 1990. In general, URM buildings have the advantages of reducing the construction time and easy to construction. However, URM buildings do not have enough strength against the lateral force. Moreover, low rise buildings have not adopted seismic designs, and for that reason a critical damage is expected with an earthquake. And also, the necessity of the seismic performance evaluation of existing building structures is raised through the Taiwan earthquake in 1999. The purpose of this study is to provide basic information for unreinforced masonry building in Korea by application of the proposed seismic evaluation method. In this study, seismic capacities of 50 existing unreinforced masonry buildings are evaluated based on the proposed method. Also, relationships of seismic capacities between Korean earthquake damage ratios of korean unreinforced masonry buildings are estimated. Results of this study were as follows; 1)Seismic retrofit was needed $8{\sim}48%$ in Korean unreinforced masonry buildings. 2)Korean unreinforced masonry buildings were expected to have severe damage under the earthquake intensity level experienced in Japan.