• Title/Summary/Keyword: low-field measurement

Search Result 562, Processing Time 0.029 seconds

Selective detection of AC transport current distributions in GdBCO coated conductors using low temperature scanning Hall probe microscopy

  • Kim, Chan;Kim, Mu Young;Park, Hee Yeon;Ri, Hyeong-Ceoul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.1
    • /
    • pp.26-29
    • /
    • 2017
  • We studied the distribution of the current density and its magnetic-field dependence in GdBCO coated conductors with AC bias currents using low temperature scanning Hall probe microscopy. We selectively measured magnetic field profiles from AC signal obtained by Lock-in technique and calculated current distributions by inversion calculation. In order to confirm the AC measurement results, we applied DC current corresponding to RMS value of AC current and compared distribution of AC and DC transport current. We carried out the same measurements at various external DC magnetic fields, and investigated field dependence of AC current distribution. We notice that the AC current distribution unaffected by external magnetic fields and preserved their own path on the contrary to DC current.

Low Fiele Measurement of 0.1 mT by Rabi's NMR Method (Rabi법 핵자기 공명에 의한 0.1 mT의 저자장 측정)

  • 유권상;김철기;우병칠;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.2
    • /
    • pp.139-142
    • /
    • 1993
  • The Rabi's NMR experiment using polarized flowing water was performed in order to measure the low field and the good NMR signal was obtained in the range of 0.1 mT. There was a change in amplitude and phase of signal due to the sinusoidal variation with the increasing RF field. The nominal field could be determined within a few tens ppm uncertainty by the NMR signal under the optimized RF condition.

  • PDF

A study of the effect of the temperature on the As Te Ge Si amorphous semiconductor (As Te Ge Si 무정형 반도체의 온도영향)

  • 박창엽
    • 전기의세계
    • /
    • v.23 no.6
    • /
    • pp.49-55
    • /
    • 1974
  • Amorphous semiconductor from As 30 Te 48 Ge 10 Si 12 was prepared, and studied electron microscopy, X-ray analysis and resistivity measurement. It's resistivity is 1.56*10$^{6}$ .ohm.-cm when small ampule is used for preparing sample it is found that no phase separation has occurced by electron microscopy, and that phase transition temperature is 232.deg. C by differential Thermal Analysis. The specimen showed threshold switching that the low resistance state occur at critical electric field and the resistance recover at low applied field. Critical electric field of the switching is 10$^{5}$ V/cm at room temperature. Threshold voltage secreace exponentially with increasing ambient temperature and at that each voltage resistance of the switching device increase exponentially. According to the series resistance and applied vottage current slope on the V-I curve is varied. When applied voltage is decreased after switching, the resistance of the switching device is increased. By this result the origin of the switching is the Joule's heating.

  • PDF

Pressure-Rise Measurement and Analysis of Low Current Interruption Capability of a 72.5kV 20kA Gas Circuit Breaker for Electrical Railway System (72.5kV 20kA 전철용 가스차단기의 압력상승 측정 및 소전류 차단성능해석)

  • Song, K.D.;Park, K.Y.;Chong, J.K.;Oh, Y.H.;Min, K.S.;Park, Ki-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.164-166
    • /
    • 1998
  • This paper presents the results of the measured pressure-rise and the analyzed results of the cold gas flow-field in a 72.5kV 20kA gas circuit breaker for the electrical railway system. The analysis of cold gas flow field and the calculation of electric field strength have been performed in 3 types of interrupters and the low current interruption capability has been estimated for each of the gas circuit breaker considering the opening speed, the nozzle shape and the stroke length.

  • PDF

Characteristics of Time Varying Magnetic Fields in Thyristor Rectifiers of 19kA in Chlor-Alkali Industry

  • Shirmohammadi, Siamak;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.383-384
    • /
    • 2014
  • This paper investigates the experimental and simulated time-varying magnetic field generation in a chlor-alkali manufacturing process. 19kA thyristor-based rectifier is modeled and analyzed. The performance is compared and evaluated on the basis of exposure guidelines from ICNIRP. The mechanical structure of current carrying conductor is simplified as an infinite long busbar model and low frequency harmonic contents up to 65kHz are considered. Thyristor rectifier generates a significant amount of low frequency magnetic field harmonic contents both at ac and dc busbar of rectifier infringing the limit of ICNIRP. Along with simulation analysis the experimental measurement of the time-varying magnetic field in ac input busbar, rectifier block, dc load and busbar are presented. The experimental test results partly confirm the simulation results.

  • PDF

Laboratory/Field evaluation and calibration method of low-cost PM sensor for indoor PM2.5, PM10 measurement (실내 미세먼지 측정을 위한 저가형 PM 센서의 실험실/현장 평가 및 보정 방법)

  • Doheon, Kim;Dongmin, Shin;Jungho, Hwang
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.109-127
    • /
    • 2022
  • Recently, low-cost particulate matter (PM) sensors have been widely used in monitoring mass concentration. Maintaining the accuracy of the sensors is important and requires rigorous performance evaluation and calibration. In this study, two commercial low-cost PM sensors(LCS), Plantower PMS3003 and Plantower PMS7003, were evaluated in the laboratory and field with a reference-grade PM monitor (GRIMM 11-D). Laboratory evaluation was conducted with single/mixed particles of PSL (Poly Styrene Latex) in an acrylic chamber at 20℃ and relative humidity of 20%. Field evaluation was conducted inside a building of Yonsei University (Shinchon) from February 12 to March 31, 2022. In both evaluations, LCS measured values became different from reference measured values when the relative humidity was high or the outdoor air PM10/PM2.5 ratio was high. Based on the field evaluation, the LCS measured values were corrected through four different regression analysis models. As a result, the multivariate polynomial regression analysis model showed highest matching with the reference PM monitor (PM2.5 >0.9, PM10 >0.85). In this model, the PM10/PM2.5 ratio and relative humidity were chosen as independent variables.

Quantitative Acetone PLIF Measurement of Fuel Distribution in a Gas Turbine Combustor Burner (아세톤 PLIF를 이용한 가스터빈 연소기 버너 출구 연료분포의 정량적 측정)

  • Jeon, Woo-Jin;Kim, Hyung-Mo;Lee, Kang-Yeop;Yang, Su-Seok
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.4
    • /
    • pp.43-52
    • /
    • 2010
  • A non-intrusive measurement, Planar Laser Induced Fluorescence was employed to visualize and measure the fuel distribution of the non-reacting field at the burner exit of gas turbine combustor. Measurement techniques, image processing method and quantification procedure were presented. Also, concentration measurement with gas analyzer was carried out to verify the propriety of PLIF result. The PLIF result coincides well with gas analyzer measurement result. PLIF test result for several other conditions are mentioned as well.

Measurement of Nonlinear Dielectric Constant (비선형 유전율의 측정)

  • Roh, I.S.;Kang, D.H.;Lee, S.U.;Heo, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1331-1333
    • /
    • 2001
  • In this study a measurement equipment was designed and made for the nonlinear dielectric constants in dielectrics. The determining method of the nonlinear dielectric constants also was proposed. The measurement equipment was consisted of the wave generation part, the high voltage amplifier part, the measurement part and the data acquisition part. In this equipment the measurement control and the data processing could be conducted by computer. In order to determine the nonlinear dielectric constants alternating sign-wave electric fields are applied to dielectrics with different magnitude and the waves of the electric fields and the response from dielectrics are stored in computer memories. The harmonics of dielectric displacement are obtained by the Fourier transformation of these waves. The nonlinear dielectric constants are determined at the relatively low-field region. The experiment for PZT ceramic samples was done by the equipment and the determining method and as the result meaningful data were obtained.

  • PDF

Measurement method for valve noise (밸브의 소음 측정 방법)

  • Lee, Y. B.;Yoon, B. R.;Kwon, H. S.;Park, K. A.;Yoo, S. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.433-438
    • /
    • 2001
  • Noise is one of the major environmental problems in human life. To reduce the noise emitted from the control valve it is necessary to develop the measurement method, measurement system, analysis method applicable to the field. In this study IEC and ISO standards were investigated and measurement method for the valve noise was proposed. Noise from the valve was measured in the reverberation room and sound power level was calculated. The sound power level increased as the flow rate and pressure difference increased. The noise characteristics are useful to predict valve noise for given conditions, to compare the performance of different valves and to develope low-noise valves.

  • PDF

The crystallinity and electrical characteristics of low density polyetylene thin film (저밀도 폴리에틸렌 필림의 결정화도 및 전기적 특성)

  • 윤중락;권정열;이헌용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.164-168
    • /
    • 1996
  • The relation between crystallinity and thermal history in low density polyethylene thin films and their effect on electric conduction phenomena and dielectric breakdown was studied. The low density polythylene thin films obtained by the solution growth method heat-treated at 140[$^{\circ}C$] for 2 h and subsequently cooling to various ways. The degree of crystallinity was estimated by the X-ray diffraction measurement for the specimen of slowly cooling, ICE quenching and liquid nitrogen quenching. The result shows that the crystallinity decreases become faster as the cooling speed increased, and that conduction phenomenon is governed by the space charge limited current in high field. It was found that the dielectric breakdown field increases with an increase in cooling speed and test number in self-healing breakdown method.

  • PDF