• 제목/요약/키워드: low-field measurement

검색결과 564건 처리시간 0.441초

A Study on the Evaluating Indicators of the Level of Deterioration in High-rise and high-density Apartments (고층고밀 아파트단지의 노후도 평가지표 개발)

  • Cho, Sung-Heui;Lee, Tae-Kyung
    • Journal of the Korean housing association
    • /
    • 제20권4호
    • /
    • pp.131-142
    • /
    • 2009
  • High-rise and high-density apartment complexes have been built and supplied on a large scale in the 1st period of the New Town project in metropolitan areas since the late 1980s. Now It has become necessary to improve those apartment complexes, which have serious deterioration problems for aging more than about 20 years accompanying simultaneity and a large scale. The purpose of this research is to develop the evaluating indicators to measure the level of deterioration of apartments inclusively and practically in order to regenerate apartments as sustainable residential environments. This study is composed of the following four parts; (a) establishing the conceptual model of evaluation of apartment deterioration, (b) selecting evaluation items, (c) constituting evaluation measurement, and(d)weighting evaluation indicators. First, deterioration of apartments was conceptualized by physical. social, and economical aspects in terms of sustainable development and proposed the conceptual model of hierarchy structure of evaluation of apartment deterioration by literature reviews. Second, evaluating items were selected based on literature reviews of existing indicators and preceding studies about apartments of Korea and foreign countries. The evaluating indicators were identified as a total of 77 evaluating items which were composed of three dimensions and 9 attributes on the basis of the conceptual model. They cover comprehensive scope of the apartment such as unit, building, complex, and site. Third, as the measurement, the 5 point ordinal scale measure was suggested. The evaluating measurement including measure standards, measure methods, and measure contents were developed by each evaluating items. Lastly, the weighting of evaluating indicators was analyzed by AHP method conducted by survey on the expert group. Items were identified as high contributors or low contributors. The weighting of these items could suggest several evaluations according to the situation. The evaluation of the level of deterioration can be done by both total evaluation and a specific field of evaluation. In addition, it is easy to grasp deteriorated attributes or dimensions by providing a radar and bar chart showing evaluation results. These evaluating indicators could be a useful tool to grasp actual methods for the regeneration of apartments.

Low Stratospheric Wind Measurement Using Mobile Rayleigh Doppler Wind LIDAR

  • Shu, Zhi-Feng;Dou, Xian-Kang;Xia, Hai-Yun;Sun, Dong-Song;Han, Yan;Cha, Hyunki;Kim, Dukhyeon;Wang, Guo-Cheng;Baik, Sunghoon;Hu, Dong-Dong
    • Journal of the Optical Society of Korea
    • /
    • 제16권2호
    • /
    • pp.141-144
    • /
    • 2012
  • A mobile Rayleigh Doppler wind LIDAR at an eye-safe wavelength of 355 nm incorporating double-edge technique with triple-channel Fabry-Perot etalon is developed for wind measurement from 5 to 40km. The structure of this LIDAR system is described. An intercomparsion experiment with rawinsonde is made, showing good agreement with expected measurement accuracy. A continuous observation of stratosphere wind field for several days with temporal resolution of 15 min and spatial resolution of 200 m from 5 to 40 km is presented, demonstrating the stability and robustness of the LIDAR. A stratospheric quasi-zero wind layer can be found at around 20 km with a direction change from east to west evident in the continuous observation.

Growth and characterization of molecular beam epitaxy grown GaN thin films using single source precursor with ammonia

  • Chandrasekar, P.V.;Lim, Hyun-Chul;Chang, Dong-Mi;Ahn, Se-Yong;Kim, Chang-Gyoun;Kim, Do-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.174-174
    • /
    • 2010
  • Gallium Nitride(GaN) attracts great attention due to their wide band gap energy (3.4eV), high thermal stability to the solid state lighting devices like LED, Laser diode, UV photo detector, spintronic devices, solar cells, sensors etc. Recently, researchers are interested in synthesis of polycrystalline and amorphous GaN which has also attracted towards optoelectronic device applications significantly. One of the alternatives to deposit GaN at low temperature is to use Single Source Molecular Percursor (SSP) which provides preformed Ga-N bonding. Moreover, our group succeeds in hybridization of SSP synthesized GaN with Single wall carbon nanotube which could be applicable in field emitting devices, hybrid LEDs and sensors. In this work, the GaN thin films were deposited on c-axis oriented sapphire substrate by MBE (Molecular Beam Epitaxy) using novel single source precursor of dimethyl gallium azido-tert-butylamine($Me_2Ga(N_3)NH_2C(CH_3)_3$) with additional source of ammonia. The surface morphology, structural and optical properties of GaN thin films were analyzed for the deposition in the temperature range of $600^{\circ}C$ to $750^{\circ}C$. Electrical properties of deposited thin films were carried out by four point probe technique and home made Hall effect measurement. The effect of ammonia on the crystallinity, microstructure and optical properties of as-deposited thin films are discussed briefly. The crystalline quality of GaN thin film was improved with substrate temperature as indicated by XRD rocking curve measurement. Photoluminescence measurement shows broad emission around 350nm-650nm which could be related to impurities or defects.

  • PDF

Development of Unmanned Remote Radiation Detection Module (무인 원격 방사선 검출 모듈 개발)

  • Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • 제15권6호
    • /
    • pp.795-801
    • /
    • 2021
  • The designed drone-based unmanned remote radiation detection module was developed according to the needs of the nuclear power plant decommissioning workshop. Using the Geiger-Mueller tube sensitive to low-level radiation measurement, It was manufactured to measure the amount of radiation leaking into and out of the containment vessel. The drone-based radiation detection module weighs less than 200g, It can be operated inside and outside the containment vessel of a nuclear power plant. To check the performance of the designed equipment, a performance evaluation test was conducted with reference to the international standard (IEC-60864). The stability of the radiation detection module designed to meet the needs of the field the statistical rate of change by repeated measurements in the rate of change experiment to evaluate the measurement accuracy was ±4.6%. The accuracy ±7.3% in the linearity experiment to evaluate the dose rate dependence, the linear The figure satisfies the international performance evaluation standard of ±3.5%. The radiation detection module developed in this study is a customized equipment for a nuclear power plant dismantling workshop. It will be helpful for accurate measurement of space dose rate and safety management of radiation worksites in sites with a lot of radiation dust.

Microstructure and Strengthening Mechanism Characteristics of Titanium Fabricated by SPS Method after Mechanical Milling Treatment (기계적 밀링 처리하여 SPS법으로 제작한 티타늄의 미세조직과 강화기구 특성)

  • Chang-Suk Han;June-Sung Kim;Woo-Bin Sim
    • Korean Journal of Materials Research
    • /
    • 제33권6호
    • /
    • pp.242-250
    • /
    • 2023
  • Titanium, which has excellent strength and toughness characteristics, is increasingly used in the aerospace field. Among the titanium alloys used for body parts, more than 80 % are Ti-6Al-4V alloys with a tensile strength of 931 MPa. The spark plasma sintering (SPS) method is used for solidification molding of powder manufactured by the mechanical milling (MM) method, by sintering at low temperature for a short time. This sintering method avoids coarsening of the fine crystal grains or dispersed particles of the MM powder. To improve the mechanical properties of pure titanium without adding alloying elements, stearic acid was added to pure titanium powder as a process control agent (PCA), and MM treatment was performed. The properties of the MM powder and SPS material produced by solidifying the powder were investigated by hardness measurement, X-ray diffraction, density measurement and structure observation. The processing deformation of the pure titanium powder depends on the amount of stearic acid added and the MM treatment time. TiN was also generated in powder treated by MM 8 h with 0.50 g of added stearic acid, and the hardness of the powder was higher than that of Ti-6Al-4V alloy when treated with MM for 8 h. When the MM-treated powder was solidified in the SPS equipment, TiC was formed by the solid phase reaction. The SPS material prepared as a powder treated with MM 8 h by adding 0.50 g of stearic acid also formed TiN and exhibited the highest hardness of Hv1253.

Experimental Investigation on the Effect of Low-Speed Icing Condition to the Surface Roughness Formation (저속 결빙조건이 표면 조도 형성에 미치는 영향에 관한 실험적 연구)

  • Kang, Yu-Eop;Min, Seungin;Kim, Taeseong;Yee, Kwanjung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제48권2호
    • /
    • pp.99-108
    • /
    • 2020
  • In the field of aircraft icing prediction, surface roughness has been considered as critical factor because it enhances convective heat transfer and changes local collection efficiency. For this significance, experimental studies have been conducted to acquire the quantitative data of the formation process. Meanwhile, these experiments was conducted under low-speed condition due to the measurement difficulties. However, it has not been investigated that how the flow characteristic of low-speed will effects to the surface roughness. Therefore, the present study conducted experiment under low-speed icing condition, and analyzed the relation between surface roughness characteristics and icing condition. As an analysis method, the dominant parameters used in the previous high-speed experiments are employed, and roughness characteristics are compared. The size of roughness element was consistent with the previous known tendency, but not the smooth zone width.

Development of a Modular Clothing System for User-Centered Heart Rate Monitoring based on NFC (NFC 기반 사용자 중심의 모듈형 심박측정 의류 시스템 개발)

  • Cho, Hakyung;Cho, SangWoo;Cho, Kwang Nyun
    • Science of Emotion and Sensibility
    • /
    • 제23권2호
    • /
    • pp.51-60
    • /
    • 2020
  • This study aimed to develop a modular smart clothing system for heart rate monitoring that reduces the inconvenience caused by battery charging and the large size of measurement devices. The heart rate monitoring system was modularized into a temporary device and a continuous device to enable heart rate monitoring depending on the requirement. The temporary device with near-field communication (NFC) and heart rate sensors was developed as a clothing attachment type that enables heart rate monitoring via smart phone tagging when required. The continuous device is based on Bluetooth Low Energy (BLE) communication and batteries and was developed to enable continuous heart rate measurement via a direct connection to the temporary device. Furthermore, the temporary device was configured to connect with a textile electrode made of a silver-based knitted fabric designed to be located below the pectoralis major muscle for heart rate measurement. Considering the user-experience factors, key functions, and the ease of use, we developed an application to automatically log through smart phone tagging to improve usability. To evaluate the accuracy of the heart rate measurement, we recorded the heart rate of 10 healthy male subjects with a modular smart clothing system and compared the results with the heart rate values measured by the Polar RS800. Consequently, the average heart rate value measured by the temporary system was 85.37, while that measured by the reference device was 87.03, corresponding to an accuracy of 96.73%. No significant difference was found in comparison with the reference device (T value = -1.892, p = .091). Similarly, the average heart rate measured by the continuous system was 86.00, while that measured by the reference device was 86.97, corresponding to an accuracy of 97.16%. No significant difference was found in terms of the heart rate value between the two signals (T value = 1.089, p = .304). The significance of this study is to develop and validate a modular clothing system that can measure heart rates according to the purpose of the user. The developed modular smart clothing system for heart rate monitoring enables dual product planning by reducing the price increase due to unnecessary functions.

Electron Emission Properties of Hetero-Junction Structured Carbon Nanotube Microtips Coated With BN And CN Thin Films (탄소 나노튜브 위에 붕소 및 탄소 질화 박막이 코팅된 이종접합 구조 미세팁의 전자방출 특성)

  • Noh, Young-Rok;Kim, Jong-Pil;Park, Jin-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제59권4호
    • /
    • pp.743-748
    • /
    • 2010
  • Boron nitride (BN) and carbon nitride (CN) films, which have relatively low work functions and commonly exhibit negative electron affinity behaviors, were coated on carbon nanotubes (CNTs) by magnetron sputtering. The CNTs were directly grown on metal-tip (tungsten, approximately 500nm in diameter at the summit part) substrates by inductively coupled plasma-chemical vapor deposition (ICP-CVD). The variations in the morphology and microstructure of CNTs due to coating of the BN and CN films were analyzed by field-emission scanning electron microscopy (FE-SEM). The energy dispersive x-ray (EDX) spectroscopy and Raman spectroscopy were used to identify the existence of the coated layers (CN and BN) on CNTs. The electron-emission properties of the BN-coated and CN-coated CNT-emitters were characterized using a high-vacuum field emission measurement system, in terms of their maximum emission currents ($I_{max}$) at 1kV and turn-on voltage ($V_{on}$) for approaching $1{\mu}A$. The results showed that the $I_{max}$ current was significantly increased and the $V_{on}$ voltage were remarkably reduced by the coating of CN or BN films. The measured values of $I_{max}-V_{on}$ were as follows; $176{\mu}A$-500V for the 5nm CN-coated emitter and $289{\mu}A$-540V for the 2nm BN-coated emitter, respectively, while the $I_{max}-V_{on}$ of the as-grown (i.e., uncoated) emitter was $134{\mu}A$-620V. In addition, the CNT emitters coated with thin CN or BN films also showed much better long-term (up to 25h) stability behaviors in electron emission, as compared with the conventional CNT emitter.

Comparison of Flood Discharge and Velocity Measurements in a Mountain Stream Using Electromagnetic Wave and Surface Image (전자파와 수표면 영상을 이용한 산지하천 홍수유량 및 유속 계측 비교 연구)

  • Yang, Sung-Kee;Kim, Dong-Su;Yu, Kwon-Kyu;Kang, Meyong-Su;Jung, Woo-Yul;Lee, Jun-Ho;Kim, Yong-Seok;You, Ho-Jun
    • Journal of Environmental Science International
    • /
    • 제21권6호
    • /
    • pp.739-747
    • /
    • 2012
  • Due to the difficulties for measuring flood discharge in the dangerous field conditions, conventional instruments with relatively low accuracy such as float still have been widely utilized for the field survey. It is also limited to use simple stage-discharge relationship for assessment of the flood discharge, since the stage-discharge relationship during the flood becomes complicated loop shape. In recent years, various non-intrusive velocity measurement techniques such as electromagnetic wave or surface images have been developed, which is quite adequate for the flood discharge measurements. However, these new non-intrusive techniques have little tested in the flood condition, though they promised efficiency and accuracy. Throughout the field observations, we evaluated the validity of these techniques by comparing discharge and velocity measurements acquired concurrently during the flood in a mountain stream. As a result, the flood discharge measurements between electromagnetic wave and surface image processing techniques showed high positive relationship, but velocities did not matched very well particularly for the high current speed more 3 m/s. Therefore, it should be noted here that special cares are required when the velocity measurements by those two different techniques are used, for instance, for the validation of the numerical models. In addition, authors assured that, for the more accurate flood discharge measurements, velocity observation as well as stage height is strongly necessary owing that the unsteady flow occurs during the flood.

Measurement of Nonwoven Geotextile Deformation with Strain Gauges (스트레인 게이지를 이용한 부직포의 변형거동 계측)

  • Won, Myoung-Soo;Lee, Yong-An;Ko, Hyoung-Woo;Kim, You-Seong;Park, Byung-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.96-102
    • /
    • 2006
  • Because of the increasing need to use clayey soil as the backfill in reinforced soil structures and embankment material, nonwoven geotextiles with the drain capability have been receiving much attention. However, there are few studies of the deformation behavior of nonwoven geotextiles at geosynthetics reinforced soil structures in the field because the nonwoven geotextile, which has low tensile stiffness and higher deformability than geogrids and woven geotextiles, is difficult to measure its deformation by strain gauges and to prevent the water from infiltrating. This study proposes a new, more convenient method to measure the deformation behaviour of nonwoven geotextile by using a strain gauge; and examines the availability of the method by conducting laboratory tests and by applying it on two geosynthetics reinforced soil (GRS) walls in the field. A wide-width tensile test conducted under confining pressure of 7kPa showed that the local deformation of nonwoven geotextile measured with strain gauges has a similar pattern to the total deformation measured with LVDT. In the field GRS walls, nonwoven geotextile showed a larger deformation range than the woven geotextile and geogrid; however, the deformation patterns of these three reinforcement materials were similar. The function of strain gauges attached to nonwoven geotextile in the walls works normally for 16 months. Therefore, the method proposed in this study for measuring nonwoven geotextile deformation by using a strain gauge proved useful.

  • PDF