• 제목/요약/키워드: low-field measurement

Search Result 562, Processing Time 0.033 seconds

Simple Interpretation of VLF Data (VLF 전자탐사 자료의 해석)

  • Kim Hee Joon;Nam Myung Jin;Song Yoonho;Suh Jung Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.184-190
    • /
    • 2005
  • We have attempted to give some physical into the factors that control the response of subsurface target to plane wave excitation at VLF (very low frequency) frequencies. Although the VLF technique has some serious disadvantages, such as a lack of penetration depth and limited frequencies, its advantages are also extremely important to have made it by far the most popular electromagnetic technique in current use. In the magnetic-field measurement mode these lightweight, relatively low-priced tools allow us to survey large areas rapidly and inexpensively, to locate and roughly define subsurface electrical conductors. When used in the electric-field mode the technique is, in simple environments, capable of quantitative interpretation and once again the speed and relative cheapness of these devices makes them a natural 'first electromagnetic tool ' to use in reconnaissance mapping.

Effect of splenectomy on the blood and marrow megakaryocyte picture in dogs (견(犬)에 있어서 비장적출(脾臟摘出)이 혈액(血液) 및 골수거대핵세포상(骨髓巨大核細胞像)에 미치는 영향(影響))

  • Hong, Kyung-tae;Lee, Hyun-beom;Lee, Keun-woo
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.2
    • /
    • pp.327-336
    • /
    • 1993
  • Present experiments were undertaken in order to clarify the effect of splenectomy on the hematology and marrow megakaryocyte picture and to know the genesis of postsplenectomy thrombocytosis in dogs. Six mongrel dogs weighing 8.5~18㎏ were used, of which three were splenectomized and the other three were laparotomized for comparison. Erythrocyte count, total and differential leukocyte counts, thrombocyte count and packed cell volume measurement were made using the blood samples. In addition, bone marrow samples obtained from the femur at 7th and 23rd day of the operation were examined for the number per low-power field, the diameter, and the distribution frequency of the megakaryocyte. From these experiments, following results were obtained : Erythrocyte count and packed cell volume showed significant decrease beginning on the 15th day of splenectomy. Total and differential leukocyte counts showed marked increase for the first 2 days of postsplenectomy. The thrombocyte count of splenectomized dogs increased from the 2nd day of the operation, reached to the peak count on the 15th day, and returned to the preoperation count by the 28th day. The megakaryocyte count per low-power field of the biopsied preparation increased in according to the increase in thrombocyte count. The megakaryocyte diameter of splenectomized dog showed no increase on the 7th or 23rd day of the operation. However, the distribution frequency of the larger megakaryocyte was higher in the splenectomized dogs than in the laparotomized dogs. The total plasma protein concentration showed no significant change after splenectomy or laparotomy. From these results, it may be concluded that the postsplenectomy thrombocytosis results from the increased megakaryocytopoesis or the activated thrombocytopoesis of the marrow megakaryocytes.

  • PDF

Eddy Covariance Measurement of CH4 Flux in a Rice Paddy in Gimje, Korea (김제 논에서 메탄 플럭스의 에디 공분산 관측)

  • Talucder, Samiul Ahsan;Yun, Juyeol;Kang, Namgoo;Shim, Kyo Moon;Kim, Joon
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2013.11a
    • /
    • pp.28-29
    • /
    • 2013
  • We have been measuring $CH_4$ flux in a rice paddy in Gimje using the eddy covariance method since July 2011. In order to measure the fast fluctuations of $CH_4$ concentration, an innovative LI-7700 open-path laser spectrometer is used. This high-precision, low power, light weight, low maintenance sensor enables us to operate it on a continuous and long-term basis. One particular feature, among other things, is the self-cleaning lower mirror which decreases maintenance requirements while ensuring more robust, continuous, high-quality dataset. Its cleaning is initiated at user-specified time intervals or a signal strength threshold, and its status is recorded as a diagnostic index. We have noticed that the operation of LI-7700 at Gimje site is quite challenging particularly due to its frequent mirror cleaning requirement and the associated sensitivity of the instrument. In this presentation, we present some field observation data regarding the mirror cleaning and their analysis, thereby suggesting the pertinent operation options for high-quality, maximum data retrieval in the field.

  • PDF

Integrity Assessment and Verification Procedure of Angle-only Data for Low Earth Orbit Space Objects with Optical Wide-field PatroL-Network (OWL-Net)

  • Choi, Jin;Jo, Jung Hyun;Kim, Sooyoung;Yim, Hong-Suh;Choi, Eun-Jung;Roh, Dong-Goo;Kim, Myung-Jin;Park, Jang-Hyun;Cho, Sungki
    • Journal of Astronomy and Space Sciences
    • /
    • v.36 no.1
    • /
    • pp.35-43
    • /
    • 2019
  • The Optical Wide-field patroL-Network (OWL-Net) is a global optical network for Space Situational Awareness in Korea. The primary operational goal of the OWL-Net is to track Low Earth Orbit (LEO) satellites operated by Korea and to monitor the Geostationary Earth Orbit (GEO) region near the Korean peninsula. To obtain dense measurements on LEO tracking, the chopper system was adopted in the OWL-Net's back-end system. Dozens of angle-only measurements can be obtained for a single shot with the observation mode for LEO tracking. In previous work, the reduction process of the LEO tracking data was presented, along with the mechanical specification of the back-end system of the OWL-Net. In this research, we describe an integrity assessment method of time-position matching and verification of results from real observations of LEO satellites. The change rate of the angle of each streak in the shot was checked to assess the results of the matching process. The time error due to the chopper rotation motion was corrected after re-matching of time and position. The corrected measurements were compared with the simulated observation data, which were taken from the Consolidated Prediction File from the International Laser Ranging Service. The comparison results are presented in the In-track and Cross-track frame.

A study on the emissions of SOx and NH3 for a 78 kW class agricultural tractor according to agricultural operations

  • Baek, Seung Min;Kim, Wan Soo;Lee, Jun Ho;Kim, Yean Jung;Suh, Dae Seok;Chung, Sun Ok;Choi, Chang Hyun;Gam, Byoung Woo;Kim, Yong Joo
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.1135-1145
    • /
    • 2020
  • The purpose of this study was to compare and analyze the emissions of SOx and NH3 for a 78 kW class agricultural tractor during agricultural operations. A real-time monitoring system was constructed for measuring the load data. The field test was conducted during plow and rotary tillage. The working conditions were selected with the transmission gears in M3 Low and M2 High for the plow tillage and L3 High and L3 Low for the rotary tillage. The engine torque and fuel consumption were measured using controller area network (CAN) communication, and the emissions of SOx and NH3 were calculated based on the fuel consumption. As a result of the field tests, the engine torque was higher for the plow tillage than for the rotary tillage. As the gear stage was increased, the engine torque became higher. The emissions of SOx and NH3 were higher for the plow tillage than for the rotary tillage because the fuel consumption increased. Moreover, the emissions of SOx and NH3 tended to be more distributed for the rotary tillage than for the plow tillage. To develop an emission factor for agricultural machinery, it is important to measure reliable emission data during agricultural operations. In a future study, we will collect various emission data using a portable emission measurement system during agricultural operations.

Measurement of Volatile Organic Sulfur Compounds in Ambient Air by Canister and Tedlar-bag Sampling Method (캐니스터와 Tedlar-bag 시료채집법을 이용한 대기 중의 휘발성유기황화합물의 측정)

  • 전선주;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.417-428
    • /
    • 1999
  • The measurement of VOSCs(volatile organic sulfur compounds) in the air is nowadays a very important environmental research field. It is, however, very difficult because the concentration of the VOSC in ambient air is usually very low and the high reactivity makes it difficult to keep in container without loss of recovery. In this study, sampling method with cryogenic preconcentration is evaluated for analysis of atmospheric VOSC such as $CH_3SH,\;CH_3CH_2SH,\;CH_3SCH_3,\;CS_2,\;CH_3SSCH_3,\;CH_3SCH_2SCHA_3,\;and\;C_2H_5SSC_2H_5$ analyzed by GC-MS or GC-FID. Repeatabilities of measurement accompanied with preconcentration for 3-successive runs were in the range of 0.2~1.0% as a relative standard deviation. Stabilities up to 13 days were measured in 6 L canister and 10 L tedlar bag filled with VOSCs in ppb level. Higher stability was observed in tedlar bag as compared to canister with glass coated inner walls, and thiol compounds show dramatic losses in canister within 2~3 days. It is found that recovery over 70% was obtained in a week for all tested VOSCs when the compounds from ambient air matrix were stored in tedlar bag. It is also found that the stabilities of VOSCs are depending on humidity and coexisting compounds in matrix gas due to sample adsorption onto inner surface and reactivity. The results indicate the possibility and limitations of VOSC analysis in ambient air using container sampling method with cryogenic preconcentration.

  • PDF

The Early Detection of the Protein Toxin using Sanification and Fluorescent Dye in the Field (현장에서 초음파 파쇄와 형광시약을 이용한 단백질 독소의 조기 탐지)

  • Ha, Yeon-Chul;Choi, Ki-Bong;Kim, Seong-Joo;Choi, Jung-Do
    • KSBB Journal
    • /
    • v.22 no.1
    • /
    • pp.48-52
    • /
    • 2007
  • This study was carried out to establish the optimum disruption condition of a sonificator for the protein toxin for the purpose of developing automatic biological agent detector equipped a sonificator. One of the best-known collisional quenchers is molecular oxygen, which quenches almost all known fluorophores. The sonification does an excellent job of degassing, which decreased the quenching effect and increased the fluorescence quantity. The fluorescence measurement for the protein using 0.7 X fluorescent dye concentration and above must be done in 1 minute and the fluorescence measurement for the protein using 0.3 X fluorescent dye concentration and below has to be done between 2 and 3 minute. The fluorescence quantity of the sonificatied protein sample was much higher that of the non-sonificatied protein sample. Sonificating the sample turned out to be favorable for the fluorescence measurement when measuring at the low protein concentration.

A Study on Measurement of Internal Defects of Pressure Vessel by Digital Shearography(I) (전자 전단 간섭법을 이용한 압력용기의 내부결함 측정에 관한 연구(I))

  • Kang, Young-June;Park, Nak-Kyu;Ryu, Won-Jae;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.393-401
    • /
    • 2002
  • Pipelines in power plants, nuclear facilities and chemical industries are often affected by corrosion effects. It is important to inspect the internal defects in pipelines in oder to guarantee safe operational condition. We have taken relatively much time, cost and manpower to use conventional NDT methods because these methods are contact measuring methods. In this paper, we used digital shearography, a laser-based optical method which allows full-field measurement of surface displacement derivatives. This method has many advantages in practical use, such as low sensitivity to environmental noise, simple optical configuration and real time measurement. The experiment was performed with pressure vessels which has different internal cracks and detected internal cracks in the pressure vessels at a real time using phase shifting method.

Design and implementation of comb filter for multi-channel, 24bit delta-sigma ADC (다채널 24비트 델타시그마 ADC 용 콤필터 설계 및 구현)

  • Hong, Heedong;Park, Sangbong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.427-430
    • /
    • 2020
  • The multi-channel analog signal to digital signal conversion is increasing in the field of IoT and medical measurement equipments. It has chip area and power consumption constraints to use a few single or 2_channel ADC for multi_channel application. This paper described to design and implement a proposed comb filter for multi-channel, 24bit ADC. The function of proposed comb filter is verified by matlab simulation and the FPGA test board. It was fabricated using SK Hynix 0.35㎛ CMOS standard process. The performance and chip size is compared with the existing design method that uses integrator/differentiator and FIR construction. The proposed comb filter is expected to use the IoT product and medical measurement equipments that require multi-channel, low power consumption and small hardware size.

A Study on the Evaluating Indicators of the Level of Deterioration in High-rise and high-density Apartments (고층고밀 아파트단지의 노후도 평가지표 개발)

  • Cho, Sung-Heui;Lee, Tae-Kyung
    • Journal of the Korean housing association
    • /
    • v.20 no.4
    • /
    • pp.131-142
    • /
    • 2009
  • High-rise and high-density apartment complexes have been built and supplied on a large scale in the 1st period of the New Town project in metropolitan areas since the late 1980s. Now It has become necessary to improve those apartment complexes, which have serious deterioration problems for aging more than about 20 years accompanying simultaneity and a large scale. The purpose of this research is to develop the evaluating indicators to measure the level of deterioration of apartments inclusively and practically in order to regenerate apartments as sustainable residential environments. This study is composed of the following four parts; (a) establishing the conceptual model of evaluation of apartment deterioration, (b) selecting evaluation items, (c) constituting evaluation measurement, and(d)weighting evaluation indicators. First, deterioration of apartments was conceptualized by physical. social, and economical aspects in terms of sustainable development and proposed the conceptual model of hierarchy structure of evaluation of apartment deterioration by literature reviews. Second, evaluating items were selected based on literature reviews of existing indicators and preceding studies about apartments of Korea and foreign countries. The evaluating indicators were identified as a total of 77 evaluating items which were composed of three dimensions and 9 attributes on the basis of the conceptual model. They cover comprehensive scope of the apartment such as unit, building, complex, and site. Third, as the measurement, the 5 point ordinal scale measure was suggested. The evaluating measurement including measure standards, measure methods, and measure contents were developed by each evaluating items. Lastly, the weighting of evaluating indicators was analyzed by AHP method conducted by survey on the expert group. Items were identified as high contributors or low contributors. The weighting of these items could suggest several evaluations according to the situation. The evaluation of the level of deterioration can be done by both total evaluation and a specific field of evaluation. In addition, it is easy to grasp deteriorated attributes or dimensions by providing a radar and bar chart showing evaluation results. These evaluating indicators could be a useful tool to grasp actual methods for the regeneration of apartments.