• 제목/요약/키워드: low-field measurement

검색결과 564건 처리시간 0.028초

공동주택의 건강성능 평가지표 개발에 관한 연구 (A Study on the Evaluation Indicators of Healthy Housing Quality of Multi-Family Housing)

  • 조성희;강나나
    • 한국주거학회논문집
    • /
    • 제22권1호
    • /
    • pp.43-55
    • /
    • 2011
  • The purpose this study is to develop indicators that measure the healthy housing condition of multi-family housing. The major findings are as follow: first, healthy housing was defined by physical, mental, social, and management aspects and proposed the conceptual model of hierarchy structure of evaluation of healthy housing by literature reviews. Second, evaluating items were selected based on literature reviews of existing indicators and preceding studies about both domestic and overseas multi-family housing. The evaluating indicators were identified as a total of 87 evaluating items which were composed of four dimensions and 16 attributes on the basis of the conceptual model. They cover comprehensive scope of the multi-family housing such as unit, building, complex, and site. Third, as the measurement, the 5-point ordinal scale measure was suggested. The evaluating measurement including measure standards, measure methods, and measure contents were developed by each evaluating items. Lastly, the weighting of evaluating indicators was developed by AHP method conducted by survey of an expert group. Items were identified as high contributors or low contributors. The weighting of these items could suggest several evaluations according to the situation. The level of healthy housing condition may be evaluated by both total evaluation and a specific field of evaluation.

워터프런트 지역 고층아파트의 해염분포에 관한 연구 (A study on Sea-salt distribution of High-rise Apartments in Waterfront Area)

  • 도근영;이한석;송화철
    • KIEAE Journal
    • /
    • 제6권1호
    • /
    • pp.33-38
    • /
    • 2006
  • The purpose of this study is to investigate the concentration of sea-salt distribution giving great characteristic environmentally. Therefore the field measurement was conducted to target high-rise apartments constructing in reclaimed land of Busan and measured the concentration of sea-salt by means of distance and height of high-rise apartments from coast. The results of this study were as follows ; 1) The more a horizontal distance is far from coast, the more concentration sea-salt become low. But this study can not draw conclusion exactly as differ from a tendency of the thing close to the coast and the land. 2) In the near seaside, No.132 apartment accords existing research result that in difference of the concentration of sea-salt by height, the more height is high, the more that is high. But in seaside, No.117 apartment of middle point appears that the upper story and the lower story than middle story. Once more, in inland, No.132 apartment and No.117 apartment tend toward opposite it of the seaside. The reason that the result of this measurement and existing study is not agreement is thought that it occurs to turbulent flow between apartments by construction of high-rise apartments group.

소형 경량패널을 이용한 차음성능 영향요인별 음향감쇠계수 분석 (Characteristics of Sound Reduction Index through Small Sized Lightweight Panel)

  • 양홍석;정갑철;김명준
    • 한국소음진동공학회논문집
    • /
    • 제17권12호
    • /
    • pp.1184-1194
    • /
    • 2007
  • Recently, framed structure is increasingly being used as apartment structure due to the advantages during remodeling. Therefore, the use of lightweight panel as separating wall is increasing. To construct lightweight panel structures with sound insulation performance appropriate to the conditions of each field, measurement of sound reduction index(SRI) through panel structures should be performed. In this study, measurement of SRI through 46 kinds of panel structures was performed in the condition of various factors such as surface density, air space and absorber. The result showed that SRI of panel structures was generally higher by increasing of surface density. In the case of double panel with no absorber, SRI at below critical frequency was gradually increased according to rise of air space. Double panel with absorber make remarkable improvement in SRI at low frequency, but there is a little difference compared with SRI of double panel with no absorber over critical frequency.

유전체 슬랩이 삽입된 원통형 공진기를 이용한 저손실 물질의 유전 상수 측정 (An Approach to Estimate Dielectric Constant of Low-Loss Materials Using Dielectric Slab Loaded Cylindrical Cavity Resonators)

  • 이원희
    • 한국전자파학회논문지
    • /
    • 제19권10호
    • /
    • pp.1115-1121
    • /
    • 2008
  • 본 논문에서는 유전체의 유전 상수를 결정하기 위하여 유전체 슬랩을 원통형 공진기에 삽입하여 측정하는 기술을 제안한다. 유전 상수는 빈 공진기와 유전체 슬랩이 삽입된 공진기의 공진 주파수 편차에 의해 측정된다. 특성 방정식은 정확한 필드 해석에 의해 정의되었다 측정 장치는 HP8719A 벡터 네트웍 분석기와 금속 재질의 원통형 공동 공진기를 이용하였다. 이론적인 증명은 실험과 3D 시뮬레이터인 CST사의 MWS 4.0에 의해 확인되었다. 측정 된 결과는 전반적으로 만족하였다. 측정 된 테플론과 베이클라이트의 비유전율은 각각 2.03과 4.44이다.

가교폴리에틸렌 지중케이블에서 화상계측을 이용한 수트리 열화현상 분석 (The Analysis of Water Tree Degradations in Underground Distribution Cables Using Image Measurement)

  • 김덕근;임장섭;이진;이준웅;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.19-23
    • /
    • 1998
  • Water tree degradations have been considered as one of the most important causes of failure in underground distribution cables with polymeric insulation. Water tree growth is a preliminary step in the sequence of electrical tree initiation and electrical breakdown of the insulation. In this paper, needle electrode is made use of the etching methods and the pellet type specimen is made to observe the water tree in succession. In previous methods are able to observe the tree degradations without cutting and dyeing. The water tree image is recorded on VTR with CCD camera. The tree length of X, Y axis direction and aging area(treeing area) are calculated with image measurement. As a result of this study, water tree is observed by non-destructive method. Electrical tree is initiated from needle electrode tip only but water tree is initiated from total area of water electrode. Electrical tree owing to water treeing is initiated at low electric field and grown with discontinuously. Namely, water tree is shown up a different characteristics of tree growth.

  • PDF

자외선 조사량에 따른 태양전지 모듈 봉지재의 특성 분석 (Characterization of Photovoltaic Module Encapsulant According to UV Irradiation Dose)

  • 이송은;배준학;신재원;전찬욱
    • Current Photovoltaic Research
    • /
    • 제6권3호
    • /
    • pp.81-85
    • /
    • 2018
  • The photovoltaic modules installed in the actual field are affected by various external environments and the electrical performance output value is generally lowered compared to initial output value. The most of photovoltaic modules consists of low iron glass, encapsulant (EVA), back sheet, frame and junction box assembly based on the solar cells. In this paper, the characteristics of encapsulant which is an important constituent material of photovoltaic module were verified by maximum power determination, electro luminescence images, yellowness index measurement, and gel content measurement after ultraviolet (UV) irradiation exposure. The most commonly installed 72 cells crystalline photovoltaic modules were tested after various UV exposure of 0, 15, 30, and $60kWh/m^2$ and compared with the reference module. After UV exposure of $15kWh/m^2$, which is the current international test condition, a small amount of change was observed in yellowness index and electroluminescence, while a gell content rapidly increased. At a cumulative dose of $60kWh/m^2$, which will be a new international test condition in the near future, however, the yellowness index increased sharply and showed the greatest output power drop.

공동주택 입면 변화에 따른 단지 내 소음특성 (Effects of the Facade of the Buildings on the Sound Characteristics in an Apartment Complex)

  • 김용희;이평직;전진용;이병권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.367-370
    • /
    • 2005
  • This paper investigated the sound characteristics in an apartment complex. The field measurement was conducted in order to examine the acoustical characteristics of the apartment complex in situ. As a result, it shows that there are around 3 sec. reverberation time and the additional sound reinforcements at the area of high height due to the surrounded buildings. Thus, 1:50 Scale model measurement and Raynoise computer simulation were carried out with insertion of the parapet and the canopy on the balcony. In case of a single building, the parapet was effective to reduce noise level at low floor levels, and the canopy was effective to reduce noise level at high floor levels. But it also shows that both the parapet and the canopy were not effective to reduce noise level at middle floor levels. In case of an apartment complex, the canopy was less effective to reduce noise level at each floor in comparison with case of the single building.

  • PDF

PFT법에 의한 수직적 3 ZONE 분할 조건에서의 환기량 측정 (Ventilation Measurement with PFT in Three-storied Detached House)

  • 김훈
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.506-515
    • /
    • 2013
  • The PFT (PerFluorocarbon Tracergas Technique) is of advantage to field surveys for evaluating the ventilation condition, due to its simplicity and convenience. On the other hand, it requires researchers to make some additional considerations that include uncertainties, such as the substance concentration distribution in indoor air, representativeness of a sampler, deviation of emission sources, and analysis error. In this study, the PFT and $CO_2$ tracer gas methods were applied simultaneously, to evaluate the accuracy of PFT on six ventilation conditions in the three-storied detached house. The air exchange and the outdoor air introduction a between and into zones were measured. As the results, deviations of PFT concentration distributions were observed at a sufficiently low level for an accurate determination for a house where the interior height was large, and there were relatively many partition walls. However, when a uniform airflow appeared in the indoor air, it was also validated that the indoor air would be exhausted without sufficient mixing, and consequently the measurement error of the PFT would be large.

근거리장 및 원거리장용 하이브리드 RFID 리더 안테나 (A Hybrid Reader Antenna for Near- and Far-Field RFID in UHF Band)

  • 이주용;한원근;박익모;추호성
    • 한국전자파학회논문지
    • /
    • 제20권2호
    • /
    • pp.174-182
    • /
    • 2009
  • 본 논문에서는 삼각형 패치와 서브 패치를 이용하여 국내 UHF RFID 대역에서 근거리장 영역과 원거리장 영역을 겸용하여 사용할 수 있는 안테나를 제안하였다. 제안된 안테나는 FR-4 기판에 마이크로스트립 패치로 인쇄되어 대량생산이 용이한 평면 구조이며, UHF RFID 주파수 대역(912 MHz)에서 동작하도록 설계하였다. 삼각형 패치를 이용하여 정면방향에서 원형편파 특성을 가지고 동작하며 서브 패치를 삽입하여 근거리장 영역에서 강하고 균일한 수직 자계를 형성 할 수 있도록 하였다. 측정 결과 제작된 안테나는 개구면에서 3 cm 떨어진 근거리장 영역에서 -25 dBA/m 이상의 수직 자계를 형성하며, 정면방향 원거리장에서 AR<3 dB의 원형편파를 복사하며 6 dBi의 복사 이득을 보였다.

$C_{22}$-quinolium(TCNQ) LB막의 고전게 전기전도 현상 (Electrical conduction phenomena of $C_{22}$--quinolium(TCNQ) langmuir-blodgett films under the high-electric field)

  • 신동명;김태완;홍언식;송일식;유덕선;강도열
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권2호
    • /
    • pp.138-144
    • /
    • 1994
  • Electrical conduction phenomena of $C_{22}$-quinolium(TCNQ) Langmuir- Blodgett(LB) films are reported through a study of current-voltage(I-V) characteristics along a perpendicular direction. The I-V characteristics were investigated by applying a step or a pulse voltage to the specimen as well as changing temperatures in the range of 20-250[.deg. C] It show an ohmic behavior in low-electric field, and a nonohmic behavior in high-electric field. This nonohmic behavior has been interpreted in terms of a conduction mechanism of space-charge limited current and Schottky effect. When the electric field is near the strength of 10$_{6}$ V/cm, there occur anomalous phenomena similar to breakdown. When step or pulse voltage is applied, the breakdown voltage shifts to the higher one as the step or pulse time width becomes shorter. To see the influence of temperature, current was measured as a function of temperature under the several bias voltages, which are lower than that of breakdown. It shows that the current increases to about 103 times near 60-70[.deg. C], and remains constant for a while up to around 150[.deg. C] and then suddenly drops. We have also performed a DSC(differential scanning calorimetry) measurement with $C_{22}$-quinolium(TCNQ) powder in the range of 30-300[.deg. C]. These results imply that the anomalous phenomena occuring in the high electric field are caused by the electrical and internal thermal effect such as a joule heating.ating.

  • PDF