• 제목/요약/키워드: low-dose-rate

검색결과 577건 처리시간 0.052초

RADIATION SHIELDING EVALUATION OF IP-2 PACKAGES FOR LOW- AND INTERMEDIATE-LEVEL RADIOACTIVE WASTE

  • Kim, Min-Chul;Choi, Jong-Rak;Chung, Sung-Hwan;Ko, Jae-Hoon
    • Nuclear Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.511-516
    • /
    • 2008
  • Korea Hydro & Nuclear Power Co., Ltd. (KHNP) developed new IP-2 packages to transport low- and intermediate-level radioactive waste (LILW) steel drums from nuclear power plants to a disposal facility in accordance with IAEA and Korean transport regulations of radioactive material. Radiation shielding evaluation of the packages was carried out to demonstrate compliance with the regulatory requirements for IP-2 packages of radioactive material. Dose rate limits of LILW drums contained in the packages were determined.

Determination of optimum gamma ray range for radiation mutagenesis and hormesis in quinoa (Chenopodium quinoa Willd.)

  • Park, Chan Young;Song, Seon Hwa;Sin, Jong Mu;Lee, Hyeon Young;Kim, Jin Baek;Shim, Sang In
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.240-240
    • /
    • 2017
  • Quinoa (Chenopodium quinoa Willd.) is one of the ancient crops cultivated in the Andes region at an altitude of 3,500-4000m in Chile and Bolivia from 5000 BC. It contains a large amount of protein, minerals and vitamins in comparison with other crops. The cultivation area has been increasing worldwide because of its excellent resistance to various abiotic stress such as salinity, drought and low temperature. ${\gamma}$-Ray radiation of high dose is often used as a tool to induce mutations in plant breeding, but it has a deleterious effect on organisms. However, the radiation may have a positive stimulatory effect of 'hormesis' in the low dose range. This experiment was carried out to investigate the optimum dose range for creating the quinoa genetic resources and to investigate the hormesis effect at low dose on the quinoa. This experiment was performed for 120 days from November, 2016 to February, 2017 in the greenhouse of Gyeongsang National University. ${\gamma}$-Ray radiation was irradiated to seeds at 0 Gy, 50 Gy, 100 Gy, 200 Gy, 300 Gy, 400 Gy, 600 Gy, 800 Gy and 1000 Gy for 8 hours. (50 Gy) using the low level radiation facility ($Co^{60}$) of Cooperative Research Institute of Radiation Research Institute, KAERI. Fifty seeds were placed on each petri dish lined with wet filter paper and germination rate was measured at a time interval of 2 hours for 40 hrs. The length of the root length was measured one week after germination. Each treatment was carried out in 3 replicates. The growth of seedlings were investigated for 10 days after transplanting of 30 day-old seedlings. The plant height, NDVI, SPAD, Fv/Fm, and panicle weight were measured. The germination rate was highest at 50Gy and 0Gy and the rate of seeds treated with 400Gy or higher rate decreased to 25% of the seeds treated with 50Gy. The emergence rate of seedling in pot experiment was higher at the dose of 200 Gy, 300 Gy and 400 Gy than at 0 and 50Gy. However, the rate was lower at strong radiation higher than 600Gy at which $1^{st}$ leaf was not expanded fully and dead due to extreme overgrowth at 44 days after treatment (DAT). The highest value of panicle weight was observed at 50Gy (6.15g) and 100Gy (5.57g). On the other hand, the weight at high irradiated dose of 300Gy and 400Gy was decreased by about 55% compared to low dose (50 Gy). NDVI measurement also showed the highest value at 50 Gy as the growth progressed. SPAD was the highest at 400 Gy and showed positive correlation with irradiation dose except 0 Gy. Fv/Fm was high at 50 Gy up to 30 DAT and no difference between treatments was observed except for 400 Gy from 44 DAT. The plant height was the highest in 50Gy during the growing period and was higher in the order of 50Dy, 100Gy, 0Gy, 200Gy, 300Gy and 400Gy in 88 DAT. In this experiment, the optimal radiation dose for hormesis was 50Gy and 100Gy, and the optimal radiation dose for mutagenesis seems to be 400 Gy.

  • PDF

저선량 방사선이 저온 저장한 감자 기내 소괴경의 휴면타파와 생육에 미치는 효과 (Effect of Low Dose γ Radiation on the Dormancy Breaking and Growth of in vitro Microtubers of Potato (Solanum tuberosum L.) Stored at Low Temperature)

  • 김재성;김동희;백명화;전재흥;이영복
    • 원예과학기술지
    • /
    • 제19권4호
    • /
    • pp.515-520
    • /
    • 2001
  • 기내에서 생산하여 저온 저장한 감자품종 대지와 수미 소괴경의 휴면타파에 미치는 저선량 방사선의 효과를 조사하고자 ${\gamma}$선을 0.5-30 Gy 수준으로 조사하여 맹아발생과 맹아생육 및 온실에서의 생육과 수량 등을 조사하였다. 감자 괴경의 맹아율과 생육에 대한 저선량 방사선 효과는 저장기간과 품종에 따라 다르게 나타났다. 대지 품종은 대체로 2-8 Gy에서 빠른 맹아 출현율과 양호한 생육 및 수량을 보였으며, 수미 품종은 대체로 2-4 Gy에서 맹아 출현이 빨랐고 온실에서의 생육 및 수량은 4 Gy에서 양호한 증가 효과를 보였다. 이에 저선량 ${\gamma}$선이 감자의 휴면타파와 생육촉진에 효과가 있음을 확인할 수 있었다.

  • PDF

묵은 고추종자의 발아와 생리활성에 미치는 저선량 방사선조사 효과 (Effects of low dose gamma irradiation on the germination and physiological activity of old red pepper ( Capsicum annuum L.) seed)

  • 김재성;백명화;이해연;이영근
    • Journal of Radiation Protection and Research
    • /
    • 제26권4호
    • /
    • pp.409-415
    • /
    • 2001
  • 저선량 방사선 조사가 묵은 고추종자의 발아율과 발아종자의 생리활성에 미치는 효과 등을 알아보고자 4년 저장한 조광고추와 3년 저장한 홍광고추 종자에 저선량 ${\gamma}$선을 $2{\sim}50Gy$ 까지 조사하여 관찰한 결과는 다음과 같다. 저선량 조사한 고추종자의 발아율은 대조구보다 증가하는 경향을 보였다. 특히 발아초기에 그 효과가 뚜렷하게 나타나 파종 7일 후에 조광고추 품종은 4Gy 조사구에서 74%, 홍광고추 품종은 8 Gy 조사구에서 11% 증가하였다. 고추의 유묘초장에서도 거의 모든 저선량 조사구에서 증가하였는데 특히 조광고추 품종은 4 Gy 조사구에서, 홍광고추 품종은 8 Gy 조사구에서 유의성있는 증가효과를 보였다. 저선량 조사한 종자의 단백질 함량은 조광고추 풀종은 발아후기에, 홍광고추 품종은 발아초기에 증가하였고, catalase와 peroxidase 활성은 조광고추 품종은 4 Gy 조사구에서, 홍광고추 품종은 8 Gy 조사구에서 높은 값을 보였다. 이에 저선량 ${\gamma}$선 조사에 의해 묵은 종자의 발아와 생리활성이 촉진됨을 확인할 수 있었다.

  • PDF

Nutritional strategy of early amino acid administration in very low birth weight infants

  • Lee, Byong Sop
    • Clinical and Experimental Pediatrics
    • /
    • 제58권3호
    • /
    • pp.77-83
    • /
    • 2015
  • Relative to a fetus of the same gestational age, very low birth weight (VLBW) infants are more likely to be underfed and to undergo growth restriction during their early hospital stay. The current trend towards "early and aggressive" nutritional strategies in VLBW infants aims to overcome the early nutritional deficiency and thereby boost postnatal catch-up growth, simultaneously improving long-term neurodevelopmental outcomes. Although the minimum starting amino acid (AA) dose to prevent negative nitrogen balance is well established, the upper limit and the rate of increase of early AA doses are controversial. Most randomized controlled trials show that early and high-dose (target, 3.5 to 4.9 g/kg/day) AA regimens, with or without high nonprotein calories, do not improve long-term growth and neurodevelopment. High-dose AA supplementation may lead to early metabolic disturbances and excessive or disproportionate plasma AA levels, particularly in infants of very low gestational age. Further large studies are needed to clarify the optimal strategy for early administration of parenteral AA doses in VLBW infants.

Analysis of Trends in Dose through Evaluation of Spatial Dose Rate and Surface Contamination in Radiation-Controlled Area and Personal Exposed Dose of Radiation Worker at the Korea Institute of Radiological and Medical Sciences (KIRAMS)

  • Lee, Bu Hyung;Kim, Sung Ho;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Park, Seungwoo;Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.146-155
    • /
    • 2016
  • As the probability of exposure to radiation increases due to an increase in the use of radioisotopes and radiation generators, the importance of a radiation safety management field is being highlighted. We intend to help radiation workers with exposure management by identifying the degree of radiation exposure and contamination to determine an efficient method of radiation safety management. The personal exposure doses of the radiation workers at the Korea Institute of Radiological & Medical Sciences measured every quarter during a five-year period from Jan. 1, 2011 till Dec. 31, 2015 were analyzed using a TLD (thermoluminescence dosimeter). The spatial dose rates of radiation-controlled areas were measured using a portable radioscope, and the level of surface contamination was measured at weekly intervals using a piece of smear paper and a low background alpha/beta counter. Though the averages of the depth doses and the surface doses in 2012 increased from those in 2011 by about 14%, the averages were shown to have decreased every year after that. The exposure dose of 27 mSv in 2012 increased from that in 2011 in radiopharmaceutical laboratories and, in the case of the spatial dose rate, the rate of decrease in 2012 was shown to be similar to the annual trend of the whole institute. In the case of the surface contamination level, as the remaining radiation-controlled area with the exception of the I-131 treatment ward showed a low value less than $1.0kBq/m^2$, the annual trend of the I-131 treatment ward was shown to be similar to that of the entire institute. In conclusion, continuous attention should be paid to dose monitoring of the radiation-controlled areas where unsealed sources are handled and the workers therein.

병기 IB 자궁경부암의 방사선치료에서 외부방사선치료와 고선량율 강내치료의 최적선량 배합 (Optimum Dose Combination of External Radiation and High Dose Rate ICR in FIGO IB Uterine Cervical Cancer)

  • 이상욱;서창옥;정은지;김우철;장세경;금기창;김귀연
    • Radiation Oncology Journal
    • /
    • 제14권3호
    • /
    • pp.201-209
    • /
    • 1996
  • 목적 : FIGO 병기 Ib 자궁경부편평상피암 환자에서 고선량율 강내치료를 이용한 방사선치료후 환해율, 5년 국소제어을, 5년 생존율 및 예후인자, 방사선 합병증을 분석하여 고선량율 강내치료의 효용성을 평가하고자 하였다. 그리고 심각한 후기 합병증 없이 만족스런 국소 제어율을 얻기 위한 외부방사선선량과 강내치료선량의 최적 선량배합을 알아보고자 하였다. 대상 및 방법 : 1979. 5 - 1990. 12월 까지 연세암센타 치료방사선과에서 자궁경부 편평상피암 FlGO 병기 Ib로 진단된후 근치적 목적하에 외부 및 강내치료를 받은 162명의 환자들을 대상으로 치료 결과를 후향적 분석하였다. 외부 방사선 치료는 LINAC 10MV X-ray를 이용해 180-200cGy/fr씩 4000-4600cGy14.5-5주를 전골반 부위에 시행하였근데, 일부환자에서 2000-4000 cGy에서 중앙차폐(midline block)를 시행하였다. 코발트 선원을 이용한 원격 조정 아프터 로딩 고선량율 강내치료를 A점에 1회당 300cGy씩 주 3회, 총 10-13회 (3000-3900 cGy)실시하여 A 점에 들어간 총방사선 조사량은 6420 - 9500cGy 으로 평균 8394 cGy 였다. 결과 : 방사선 치료후 완전 관해율은 $99.4\%$ 였다. 5년 전체생존율은 $91.1\%$이고, 5년 무병생존율은 $90.9\%$였다. 추적 관찰 기간동안 치료 실패 양상을 관찰해 보면 국소 실패만 보인 경우는 7명이었고 원격전이만 보인경우가 6명이었으며, 국소 및 원격전이가 모두 발생한 경우가 1예 있어서 국소제어 실괘율은 $4.9\%$(8/163), 원격전이율은 $4.3\%$(7/164)였다. 후기 합병증은 38명 ($23.5\%$)에서 발생하였초, 그 중 30병 직장 합병증으로 $18.5\%$ 후기 합병증 발생율을 보였고, 방광 합병증은 8명에서 발생하여 $4.9\%$ 후기 합병증 발생율을 보였다. 직장 합병증이 생긴 환자관에서 직장에 소사된 방사선량은 평균 7887 cGy 이었고, 합병증이 발생하지 않은 환자군의 평균조사량은 7488 cGy이었다. 결론 : 근치적 목적으로 외부 방사선 치료 및 고선량률 강내 치료는 FIGO병기 Ib 자궁경 부편평상피암을 치료하는데 매우 효과석이라 생각하였고, 외부방사선치료중 중앙차폐를 시행하여 A점 선량이 75Gy를 넘지 않게 방사선치료 설계를 하면 심각 합병증없이 좋은 치료성적을 얻을 수 있겠다.

  • PDF

Use of Cylindrical Chambers as Substitutes for Parallel-Plate Chambers in Low-Energy Electron Dosimetry

  • Chun, Minsoo;An, Hyun Joon;Kang, Seong-Hee;Cho, Jin Dong;Park, Jong Min;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.16-22
    • /
    • 2018
  • Current dosimetry protocols recommend the use of parallel-plate chambers in electron dosimetry because the electron fluence perturbation can be effectively minimized. However, substitutable methods to calibrate and measure the electron output and energy with the widely used cylindrical chamber should be developed in case a parallel-plate chamber is unavailable. In this study, we measured the correction factors and absolute dose-to-water of electrons with energies of 4, 6, 9, 12, 16, and 20 MeV using Farmer-type and Roos chambers by varying the dose rates according to the AAPM TG-51 protocol. The ion recombination factor and absolute dose were found to be varied across the chamber types, energy, and dose rate, and these phenomena were remarkable at a low energy (4 MeV), which was in good agreement with literature. While the ion recombination factor showed a difference across chamber types of less than 0.4%, the absolute dose differences between them were largest at 4 MeV at approximately 1.5%. We therefore found that the absolute dose with respect to the dose rate was strongly influenced by ion-collection efficiency. Although more rigorous validation with other types of chambers and protocols should be performed, the outcome of the study shows the feasibility of replacing the parallel-plate chamber with the cylindrical chamber in electron dosimetry.