• Title/Summary/Keyword: low-dose

Search Result 2,884, Processing Time 0.025 seconds

Adaptive Response Induced by Low Dose Ionizing Radiation in Human Lymphocytes (인체 말초 혈액 림프구에서 저선량 방사선 조사에 의해 유도되는 적응 반응)

  • Kim, Jeong-Hee;Lee, Kyung-Jong;Cho, Chul-Koo;Yoo, Seong-Yul;Kim, Tae-Hwan;Kim, Sung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.97-102
    • /
    • 1995
  • Adaptive response induced by low dose ${\gamma}-ray$ irradiation in human peripheral lymphocytes was examimed. Human lymphocytes were exposured to low dose of ${\gamma}-ray$ (priming dose, 0.01Gy) followed by high dose (challenging dose, 1.5Gy) after various time intervals (4, 7, 20 hours). Frequencies of micronuclei were enumerated in both primed and unprimed groups. Maximum reduction in frequency of micronuclei was observed when challenging dose irradiation was followed by priming dose after 4hr incubation period. When challenging doses were irradiated 7 or 20hr after priming dose, frequencies of micronuclei were reduced slighty. However, these reduction were not statistically significant. In this study, human peripheral lymphocytes were irradiated at Go phase and they showed adaptive response induced by low dose radiation. Since micronucleus assay is relatively simpler and faster than other methods, it may be a good tool for evaluating radiation-induced adaptive responses.

  • PDF

Effect of Infrared Low Dose Laser on Injured Sciatic Nerve of Rats (백서의 좌골신경 손상에 미치는 저출력 레이저의 효과 (IR-Laser))

  • Jeong, Jin-Ou;Kwon, Jae-Young;Kim, Hae-Kyu;Baik, Seong-Wan;Kim, Inn-Se;Chung, Kyoo-Sub
    • The Korean Journal of Pain
    • /
    • v.5 no.1
    • /
    • pp.44-51
    • /
    • 1992
  • This study examined the microscopic changes following irradiation of infrared low dose laser on injured sciatic nerves of rats. In these days, many clinicians use the low dose laser therapy in pain clinicians use the low dose laser therapy in pain clinic on various fields and dieases. But the basic mechanism and indications were not known completely. Low-dose IR(infrared) laser irradiation applied to a crushed injured sciatic nerve of rats in the right leg in bilaterally inflicted crush injury. The results were as follows 1) There are a little histological differences between laser treated group and nontreated group. 2) Low power IR-laser irradiation, when applied to the injured sciatic nerve, increased vascularization and relatively well conserved tissue organization. 3) There are little histological difference in distal muscle biopsy, but atrophic muscle fibers were seen partially. 4) We found out that more hypertrophic epineurium was present in laser-treated group.

  • PDF

The Effect of Low Dose Bupivacaine on Epidural Morphine Analgesia for Postoperative Pian (경막외 몰핀 단독 투여와 국소마취제 혼주가 술후 진통 효과에 미치는 영향)

  • Ha, Han-Soo;Park, Yeong-Cheol;Kim, Hae-Kyoo;Baik, Seong-Wan;Chung, Kyoo-Sub
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.188-192
    • /
    • 1994
  • Recently, epidural morphine has been administrated to decrease patients' systemic stress responses such as: suffers, endocrine responses and impairment of pulmonary function, etc. Epidural morphine provided excellent analgesic effect, but incomplete sensory blockade as compared to epidural local anesthetics, which has sympathetic blockade effect and tachyphylaxis. Therefore, the authors surmised that low dose bupivacaine on low dose epidural morphine improved postoperative pain with greater sensory analgesia than epidural morphine alone. The effect of low dose bupivacaine on epidural morphine analgesia for postoperative pain was evaluated in seventy patients. They were physical status I-III by ASA classification. Patients were randomly divided into 2 groups and they were administrated morphine 2.5 mg only (group I), morphine 2.5 mg plus 0.125% bupivacaine (group II) through epidural catheter 1 hour before the end of the operation. During postoperative second days, their analgesic effects were evaluated by visual analogue scale (0-10). Side effects were also evaluated. The results were as follows, 1) On the day of the operation, VAS score showed significant differences between two groups (morphine group $3.20{\pm}0.16$, morphine plus bupivacaine group $2.77{\pm}0.08$; p < 0.05). 2) On the postoperative and second day, there were no statistical differences between the groups according to VAS score. 3) The incidence of pruritus, nausea, and vomiting were no differences in both groups. 4) None of the patients showed objective sedation or a low respiratory rate (< 10 bpm). We concluded that epidural administration of low dose bupivacaine on the epidural morphine analgesia was an effective method to decrease postoperative pain with little change in frequencies of side effects compared to epidural morphine alone.

  • PDF

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

A SOLUTION TO THE PROBLEM WITH ABSORBED DOSE

  • Braby, Leslie A.
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.533-538
    • /
    • 2008
  • In some situations, for example at very low doses, in microbeam irradiation experiments, or around high energy heavy ion tracks, use of the absorbed dose to describe the energy transferred to the irradiated target can be misleading. Since absorbed dose is the expected value of energy per mass it takes into account all of the targets which do not have any energy deposition. In many situations that results in numerical values, in Joules per kg, which are much less than the energy deposited in targets that have been crossed by a charged particle track. This can lead to confusion about the biochemical processes that lead to the consequences of irradiation. There are a few alternative approaches to describing radiation that avoid this potential confusion. Examples of specific situations that can lead to confusion are given. It is concluded that using the particle radiance spectrum and the exposure time, instead of absorbed dose, to describe these irradiations minimizes the potential for confusion about the actual nature of the energy deposition.

Radiation Effects on the Power MOSFET for Space Applications

  • Lho, Young-Hwan;Kim, Ki-Yup
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.449-452
    • /
    • 2005
  • The electrical characteristics of solid state devices such as the bipolar junction transistor (BJT), metal-oxide semiconductor field-effect transistor (MOSFET), and other active devices are altered by impinging photon radiation and temperature in the space environment. In this paper, the threshold voltage, the breakdown voltage, and the on-resistance for two kinds of MOSFETs (200 V and 100 V of $V_{DSS}$) are tested for ${\gamma}-irradiation$ and compared with the electrical specifications under the pre- and post-irradiation low dose rates of 4.97 and 9.55 rad/s as well as at a maximum total dose of 30 krad. In our experiment, the ${\gamma}-radiation$ facility using a low dose, available at Korea Atomic Energy Research Institute (KAERI), has been applied on two commercially available International Rectifier (IR) products, IRFP250 and IRF540.

  • PDF

The Efficacy of Low-dose Aspirin Therapy for Controlled Ovarian Hyperstimulation in IVF-ET (체외수정시술 환자의 과배란유도시 저용량 아스피린 투여의 효용성에 관한 연구)

  • Lee, Eun-Sil;Lee, Sang-Hoon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.28 no.3
    • /
    • pp.225-233
    • /
    • 2001
  • Objective : To evaluate the efficacy of low-dose aspirin on IVF outcome and endometrium in patients undergoing IVF-ET. Materials and Methods : From February, 2001 to Jun, 2001, 60 infertile patients were randomly divided into study group (28 cycles) and control group (32 cycles). The study group received a daily oral dose of 25 mg of aspirin for at least 2 weeks from first visiting day. Controlled ovarian hyperstimulation was initiated in all patients with the GnRH agonist starting in the midluteal phase of the previous cycle. Results: There were no significant differences in age of the patients, basal serum E2, LH, FSH level and endometrial thickness among two groups. There were no statistically significant differences between the study group and the control group respectively in dosage ($26.5{\pm}4.8$ vs $26.2{\pm}5.3$ amples) and duration ($10.4{\pm}4.2$ vs $9.8{\pm}5.3$ days) of gonadotropin administration, serum E2 level on the hCG administration day ($1823{\pm}342$ vs $1854{\pm}543$), LH ($14.5{\pm}2.7$ vs $14.8{\pm}3.1$), FSH ($16.7{\pm}3.4$ vs $18.3{\pm}4.7$), the number of follicles > 15 mm ($13.2{\pm}6.3$ vs $12.8{\pm}5.9$), the number of oocytes retrieved ($9.2{\pm}2.4$ vs $8.4{\pm}1.7$), the number of embryos transferred ($4.7{\pm}2.0$ vs $4.7{\pm}2.0$), fertilization rate (68.4% vs 64.5%), implantation rate (21.3% vs 17.6%), and clinical pregnancy rate (28.4% vs 26.2%). The endometrial thickness and the percentage of endometrial trilaminar pattern on hCG day were significantly higher in study group than control group ($12.9{\pm}3.7mm$ vs $10.4{\pm}2.8mm$, 78.3% vs 64.5%). Conclusion: Many reports suggest that low-dose aspirin improve ovarian response, implantation rate, fertilization rate, implantation rate, and pregnancy rate by increasing the blood flow, but we couldn't prove the significant effect of low-dose aspirin on the IVF outcome except on endometrium. This may be affected by dose of aspirin, duration, and number of patients studied. This trial is small, so our results highlight the need for a large randomized controlled trial to identify the effect of low-dose as pirin on IVF-ET outcome.

  • PDF

Effect of famotidine on propranolol elimination in the isolated perfused rat liver (Famotidine이 propranolol 대사에 미치는 작용)

  • 조태순;박두순;박미정;이선미
    • Environmental Analysis Health and Toxicology
    • /
    • v.9 no.1_2
    • /
    • pp.9-17
    • /
    • 1994
  • The Ha-antagonist, cimetidine, has been shown to retard the hepatic elimination of low and high clearance drugs, and this has been attributed to inhibition of microsomal cytochrome P-450. This study was done to determine the effects of low (50$\mu\textrm{g}$) and high (1mg) dose of famotidine, another histamine H$_2$-receptor antagonist, on hepatic elimination of propranolol compared with cimetidine in the isolated perfused rat liver. Both low and high dose of cimetidine not only inhibited the elimination of propranolol but also increased the area under the perfusate propranolol concentration time curve (AUC). In contrast, low and high dose of famotidine did not affect hepatic elimination of propranolol. Our findings suggest that famotidine has not a propensity for hepatic microsomal inhibition.

  • PDF

Studies on Digitalis Receptor Desensitization in Rat Ventricle

  • Lee, Shin-Woong-;Jang, Tae-Soo
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.301-301
    • /
    • 1994
  • $^3$H〕Ouabain binding parameters(K$\_$D/ and B$\_$max/,) in homogenates prepared fpom control rat ventricular strip and Langendorff preparations which were not previously exposed to ouabain were compared to those in homogenates from ventricular strip and Langendorff preparations that had been first exposed to a complete ouabain dose-response curve(10$\^$-7/M to 10$\^$-4/ M). In rat ventricular strips and Langendorff perfused rat heart preparations, cumulative dose-response cruves of ouabain revealed biphasic positive inotropic effects, a "low-dose" and a "high-dose" effect with ED$\_$50/ values of 0.5${\mu}$M and 35${\mu}$M ouabain, respectively- The "low-dose" effect in rat ventricular strips disappeared or was diminished significantly when the ouabain dose-response curve wag repeated after the washout of the effects of the first curve, whereas the maximal "high-dose" effect was identical in both exposures to oubain. However, there was no change in the "low-dose" effects in both sets of the Langendorff perfused hearts. The contractile activity of the pre-exposed strips did not indicate the presence of residual ouabain since their basal contractile force was decreased 10% compared to initial control. 〔$^3$H〕Ouabain binding parameters, K$\_$D/ and B$\_$max/, were not changed comparing homogenate of control ventricular strips with that of strips pre-exposed to ouabain. These results suggest that digitalis receptor desensitization in the rat ventricular strip may due to the change of post-receptor events induced by ouabain binding to a high affinity site(${\alpha}$$_2$ isoform).

  • PDF

Single Oral Dose Toxicity Test of Low Molecular Weight Fucoidan in Rats

  • Yoon, Hyun-Soo;Shin, Yong-Kyu;Jung, Young-Mi;Lee, Hyeung-Sik;Ku, Sae-Kwang
    • Biomolecules & Therapeutics
    • /
    • v.17 no.3
    • /
    • pp.325-331
    • /
    • 2009
  • The object of this study was to evaluate the single oral dose toxicity of Low Molecular Weight Fucoidan (LMF) in male and female rats. LMF was administered to female and male SD rats as an oral dose of 2,000, 1,000 and 500 mg/kg (body wt.). Animals were monitored for the mortality and changes in body weight, clinical signs and gross observation organ weight and histopathology of 14 principle organs were examined upon necropsy. As the results, no LMF treatment related mortalities, clinical signs, changes on the body and organ weights, gross and histopathological observations against 14 principle organs were detected up to 2,000 mg/kg in both female and male rats except for some sporadic findings not LMF treatment related toxicological signs. Therefore, $LD_{50}$ (50% lethal dose) and approximate LD of LMF after single oral treatment in female and male rats were considered over 2,000 mg/kg - the limited dosages recommended by KFDA Guidelines [2005-60, 2005], respectively.