• 제목/요약/키워드: low-damage design

검색결과 321건 처리시간 0.032초

비대칭 Groove를 이용한 FDB 회전축의 기울기 보상 (Compensation of Inclined Rotating Axis Using Unsymmetric Groove Patterns)

  • 이남훈;한재혁;오동호;김철순;변용규;구자춘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.582-585
    • /
    • 2004
  • Most of hard disk drives currently employ fluid dynamic bearing (FDB) for their rotor support. Stiffness of the FDB is affected by many design factors such as bearing clearance, fluid viscosity, and rotational speed. For the high rotating speed HDDs stiffness of the rotor is normally high enough to accomodate load disturbances. However small form factor HDDs that are to be operated in low power consumption are often designed with low stiffness rotors. Although the low stiffness rotor clearly benefits low power operation, it could damage the entire motor structure or head disk interface even by a light mechanical load disturbance such as shock or vibration. In addition, since a single channel HDD does not provide gram load equilibrium in axial direction the rotor could be tilted and make a hard contact to stator. A non-symmetric groove pattern could successfully compensate the tilted rotor angle during operation.

  • PDF

복합화력발전소 증기터빈 동익 손상 원인분석 (Root Cause Analysis on the Steam Turbine Blade Damage of the Combined Cycle Power Plant)

  • 강명수;김계연;윤완노;이우광
    • 동력기계공학회지
    • /
    • 제12권4호
    • /
    • pp.57-63
    • /
    • 2008
  • The last stage blade of the low pressure steam turbine remarkably affects turbine plant performance and availability Turbine manufacturers are continuously developing the low pressure last stage blades using the latest technology in order to achieve higher reliability and improved efficiency. They tend to lengthen the last stage blade and apply shrouds at the blades to enhance turbine efficiency. The long blades increase the blade tip circumferential speed and water droplet erosion at shroud is anticipated. Parts of integral shrouds of the last stage 40 inch blades were cracked and liberated recently in a combined cycle power plant. In order to analyze the root cause of the last stage blades shroud cracks, we investigated operational history, heat balance diagram, damaged blades shape, fractured surface of damaged blades, microstructure examination and design data, etc. Root causes were analyzed as the improper material and design of the blade. Notches induced by erosion and blade shroud were failed eventually by high cycle fatigue. This paper describes the root cause analysis and countermeasures for the steam turbine last stage blade shroud cracks of the combined cycle power plant.

  • PDF

Design of a 170 GHz Notch Filter for the KSTAR ECE Imaging Sensor Application

  • Mohyuddin, Wahab;Woo, Dong Sik;Kim, Sung Kyun;Kim, Kang Wook;Choi, Hyun-Chul
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.8-12
    • /
    • 2016
  • A planar, light-weight, and low-cost notch filter structure is required for the KSTAR ECEI (Electron Cyclotron Emission Imaging) system to protect the mixer arrays from spurious plasma heating power. Without protection, this heating power can significantly degrade or damage the performance of the mixer array. To protect mixer arrays, a frequency selective surface (FSS) structure is the suitable choice as a notch filter to reject the spurious heating power. The FSS notch filter should be located between the lenses of the ECEI system. This paper presents a 170 GHz FSS notch filter for the KSTAR ECEI sensor application. The design of such an FSS notch filter is based on the single-sided square loop geometry, because that makes it relatively insensitive to the incident angle of incoming wave. The FSS notch filter exhibits high notch rejection with low pass-band insertion loss over a wide range of incident angles. This paper also reviews the simulated and measured results. The proposed FSS notch filter might be implemented in other millimeter-wave plasma devices.

철골구조물의 연쇄붕괴에 대한 민감도 해석 (Sensitivity Analysis of Steel Frames Subjected to Progressive Collapse)

  • 박준희;홍수민;김진구
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.307-312
    • /
    • 2008
  • Local damage may cause sequential collapse of structure, which is called progressive collapse. Current progressive collapse analysis is based on the mean value of design variables. This deterministic approach has a low reliability as it doesn't consider uncertainty of variables. In this study the sensitivity of design variables for progressive collapse of structure is evaluated by Monte Calro simulation and Tornado diagram. The analysis results show that the behaviour of model structures is highly sensitive to variation of the yield force of beams and the structural damping ratio.

  • PDF

Fiber Orientation Effects on the Fracture Process and Acoustic Emission Characteristics of Composite Laminates

  • Woo, Sung-Choong;Kim, Jung-Heun;Choi, Nak-Sam
    • 비파괴검사학회지
    • /
    • 제25권6호
    • /
    • pp.451-458
    • /
    • 2005
  • The effects of fiber orientation on acoustic emission(AE) characteristics have been studied for various composite laminates. Reflection and transmission optical microscopy were used to investigate the damage zone of specimens. AE signals were classified through short time Fourier transform(STFT) as different types: AE signals with a high intensity and high frequency band were due to fiber fracture, while weak AE signals with a low frequency band were due to matrix cracking and/or interfacial cracking. Characteristic feature in the rate of hit-events having high amplitudes showed a procedure of fiber breakages, which expressed the characteristic fracture processes of notched fiber-reinforced plastics with different fiber orientations. As a consequence, the behavior of fracture in the continuous composite laminates could be monitored through nondestructive evaluation(NDE) using the AE technique.

CAE 기법을 이용한 서스펜션 너클의 피로수명 평가 (Fatigue Life Prediction of Suspension Knuckle by CAE Technology)

  • 김영진;서명원;서상민;서재호;김중재
    • 한국자동차공학회논문집
    • /
    • 제3권2호
    • /
    • pp.112-121
    • /
    • 1995
  • Various CAE technologies are used in automobile industries for the purpose of design and analysis. In this paper, a fatigue life evaluation system FLEVA based on the local strain approach is developed and the system is applied for the fatigue strength design of the suspension knuckle, an automobile component. Various steps such as material test, finite element analysis and cumulative fatigue damage analysis of the suspension knuckle were taken. The usefulness of the approach was verified by the fatigue test on the suspension knuckle.

  • PDF

Side Buffer가 적용된 차량의 설계 고찰 (A design study of carbody with side-buffer)

  • 권승열;곽태호;전시현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1618-1623
    • /
    • 2009
  • In this paper, we describe the design method of carbody structure with side-buffer. Recently railroad industry has a new interest with stability, fixed time, low environment pollution and mass transportation. Accidents have little on the railroad but railroad industry is trying to minimize carbody damage and passenger injury in case of accidents. So a side-buffer having anti-climber is applied to meet each special needs. Carbody with side-buffer is assembled with aluminum(6005A-T6) parts that are extruded. As the results of the study, it is showed that carbody with side-buffer has sufficient energy absorbtion about crashworthiness.

  • PDF

대심도 암반의 터널 설계를 위한 지반 조사와 특성화 (Ground Investigation and Characterization for Deep Tunnel Design)

  • 윤운상;최재원;박정훈;송국환;김영근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.584-590
    • /
    • 2009
  • One of the critical design problems involved in deep tunnelling in brittle rock, is the creation of surface spalling damage and breakouts. If weak fault zone is developed in deep tunnel, squeezing problem is added to the problems. According to the results of ground investigation in the study area, hard granitic rockmass and distinguished high angle fault zone are distributed on the tunnel level over 400m depth. To analyse the probability of brittle failure and squeezing, ground characterization with special lab. and field test were carried out. By the results, probability of brittle failures like spalling and rock burst is very low. But squeezing may be probable, if weak fault zone observed surface and drill core is extended to designed tunnel level.

  • PDF

Long term health monitoring of post-tensioning box girder bridges

  • Wang, Ming L.
    • Smart Structures and Systems
    • /
    • 제4권6호
    • /
    • pp.711-726
    • /
    • 2008
  • A number of efforts had been sought to instrument bridges for the purpose of structural monitoring and assessment. The outcome of these efforts, as gauged by advances in the understanding of the definition of structural damage and their role in sensor selection as well as in the design of cost and data-effective monitoring systems, has itself been difficult to assess. The authors' experience with the design, calibration, and operation of a monitoring system for the Kishwaukee Bridge in Illinois has provided several lessons that bear upon these concerns. The systems have performed well in providing a continuous, low-cost monitoring platform for bridge engineers with immediate relevant information.

지진파 탁월주기를 고려한 비구조요소의 수평설계지진력 평가 (A Study on Evaluation of Horizontal Force of Non-structural Components Considering Predominant Periods of Seismic Waves)

  • 오상훈;김주찬
    • 한국지진공학회논문집
    • /
    • 제24권6호
    • /
    • pp.267-275
    • /
    • 2020
  • In the event of an earthquake, non-structural components require seismic performance to ensure evacuation routes and to protect lives from falling non-structural components. Accordingly, the seismic design code proposes horizontal force for the design and evaluation of non-structural components. Ground motion observed on each floor is affected by a building's eigen vibration mode. Therefore, the earthquake damage of non-structural components is determined by the characteristics of the non-structural component system and the vibration characteristics of the building. Floor response spectra in the seismic design code are estimated through time history analysis using seismic waves. However, it is difficult to use floor response spectra as a design criterion because of user-specific uncertainties of time history analysis. In addition, considering the response characteristics of high-rise buildings to long-period ground motions, the safety factor of the proposed horizontal force may be low. Therefore, this study carried out the horizontal force review proposed in the seismic design code through dynamic analysis and evaluated the floor response of seismic waves considering buildings and predominant periods of seismic waves.