• Title/Summary/Keyword: low-cost sensor

Search Result 940, Processing Time 0.026 seconds

Accuracy improvement of respiration rate based on photo-plethysmography by enhancing motion artifact (광용적맥파(PPG)를 이용한 호흡수 측정에 있어서 동잡음을 이용한 정확도 향상)

  • Huh, Young-Jung;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.447-453
    • /
    • 2008
  • Respiration rate is one of the important vital signs. Photo-plethysmography (PPG) measurement especially on a finger has been widely used in pulse oximetry and also used in estimating respiration rate. It is well known that PPG contains respiration-induced intensity variation (RIIV) signal. However, the accuracy of finger PPG method has been controversial. We introduced a new technique of enhancing motion artifact by respiration. This was achieved simply by measuring PPG on the thorax. We examined the accuracy of these two PPG methods by comparing with two existing methods based on thoracic volume and nostril temperature changes. PPG sensing on finger tip, which is the most common site of measurement, produced 6.1 % error. On the other hand, our method of PPG sensing on the thorax achieved 0.4 % error which was a significant improvement. Finger PPG is sensitive to motion artifact and it is difficult to recover fully small respiratory signal buried in waveform dominated by absorption due to blood volume changes. Thorax PPG is poor to represent blood volumes changes since it contains substantial motion artifact due to respiration. Ironically, this inferior quality ensures higher accuracy in terms of respiration measurement. Extreme low-cost and small-sized LED/silicon detector and non-constrained reflection measurement provide a great candidate for respiration estimation in ubiquitous or personal health monitoring.

Development of multi-colorimeter module for low-cost urinalysis strip readers (저가형 요분석 시스템의 다중 광 검출 모듈개발)

  • Ye, Soo-Young;Jeon, Yong-Uk;Jeong, Do-Un;Jeon, Gye-Rok;Ro, Jung-Hoon
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.387-395
    • /
    • 2008
  • An optic module system is developed adopting multiple colorimetry units for the measurement of multi-pad urinalysis dipsticks. Multiple photometry system instead of moving mechanisms has the advantages of system reliability and simplicity as well as economic aspects due to the recent development of economic color light emitting diodes and stable photo sensors. An integration amplifier with programmable integration time, a current source circuit with selectable and stable current settings were connected through analog multiplexers to thirty light emitting diodes for illumination and ten photo transistors for reading each strip pad. All the circuits are controlled by a microprocessor through a simple set of serial communication commands. The detect ability is eighteen times better than the minimum color difference of the test grading which is 0.013 in urobilinogen in the color space defined in this paper.

Development of Stretchable PZT/PDMS Nanocomposite Film with CNT Electrode

  • Yun, Ji Sun;Jeong, Young Hun;Nam, Joong-Hee;Cho, Jeong-Ho;Paik, Jong-Hoo
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.400-403
    • /
    • 2013
  • The piezoelectric composite film of ferroelectric PZT ceramic ($PbZr_xTi_{1-x}O_3$) and polymer (PDMS, Polydimethylsiloxane) was prepared to improve the flexibility of piezoelectric material. The bar coating method was applied to fabricate flexible nanocomposite film with large surface area by low cost process. In the case of using metal electrode on the composite film, although there is no problem by bending process, the electrode is usually broken away from the film by stretching process. However, the well-attached, flexible CNT electrode on PZT/PDMS film improved flexibility, especially stretchability. PZT particles was usually settled down into polymer matrix due to gravity of the weighty particle, so to improve the dispersion of PZT powder in polymer matrix, small amount of additives (CNT powder, Carbon nanotube powder) was physically mixed with the matrix. By stretching the film, an output voltage of PZT(70 wt%)/PDMS with CNT (0.5 wt%) was measured.

The Fire Detection Method Using Image Logical Operation and Fire Feature (영상 논리곱 연산과 화재 특징자를 이용한 화재 검출 방법)

  • Piao, Peng-Ji;Moon, Kwang-Seok;Ryu, Ji-Goo;Jung, Shin-Il;Kim, Jong-Nam
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.594-597
    • /
    • 2010
  • This paper proposes a fire detection algorithm using low-cost camera to detect visual features of fire. In the previous work sensor cameras were used, but here we use very simple cameras. This method uses YCbCr and YIQ color model to detect candidate regions of fire. The candidate areas are extracted from the boundaries of the fire. noise removal elimination is performed. Regardless of environmental changes around the fire area, the results of the proposed algorithm are very satisfactory.

  • PDF

A Study on the Design of Health-Care Application System through Control of Multiple RFID in USN (USN 환경에서 다중 RFID 제어를 통한 헬스케어 응용 시스템 설계에 관한 연구)

  • Lee, Yang-Sun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.8
    • /
    • pp.1937-1942
    • /
    • 2010
  • In this paper, RFID technology was applied to fitness center and order to exercise the right of each user without the guidance of a personal trainer should be made systematically. for example, excercise sequence, equipment usage, excercise and golas etc. Also, Customers who use the fitness center using RFID is trainer at a low-cost under the guidance of the same effect can be expected. In this paper, Our system will record the movements of time, as well as our system can be analyze of excercise using micro processor and acceleration sensor.

Evaluation of Standing Balance of the Elderly with Different Balance Abilities by using Kinect and Wii Balance Board

  • Yang, Seung Tae;Seo, Jung Woo;Kim, Dae Hyeok;Kang, Dong Won;Choi, Jin Seung;Tack, Gye Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.391-396
    • /
    • 2016
  • Objective: This study aimed to evaluate and identify variables for the standing balance of elderly subjects with different balancing abilities by using Kinect and Wii Balance Board. Method: The Berg Balance Scale (BBS) test was performed in 40 elderly subjects aged ${\geq}65years$ who can perform daily activities. The participants were divided into two groups, the healthy seniors (n = 20, BBS score ${\geq}52$) and the seniors with balancing problems (n = 20, BBS score < 52). Each group performed two standing tests (eyes open and eyes close) with two devices (Kinect and Wii Balance Board). The root mean square (RMS), mean distance (MDIST), range of distance (ROD), mean velocity, and 95% ellipse area were calculated from the measured data. Results: Among the calculated variables, RMS, MDIST, and ROD in the mediolateral direction showed significant differences between the two groups and a negative correlation with BBS scores. Conclusion: The results of the present study show that simple standing balance of the elderly can be measured with Kinect and Wii Balance Board, which are low-cost, easy to carry, and easy to use, by using the selected variables.

Development of Detection and Monitoring by Light Scattering in Real Time (광산란 방식 실시간 미세먼지 측정 및 모니터링 시스템 개발)

  • Lee, Nuri;Um, Hyun-Uk;Cho, Hyun-Sug
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.134-139
    • /
    • 2018
  • Extremely fine particles seriously affect people and are becoming a social problem. Conventional methods using the type of beta ray absorption are difficult to have real-time measurements and miniaturization for the acquisition of fine dust. In this paper, a light scattering method was used. The sensors were configured internally with semiconductor laser diodes for miniaturization, low cost and lightweight. The use of the FFT method makes it easier to separate fine dust according to size compared to conventional light scattering sensors. Bluetooth communication also allows the connection, monitoring and control of devices using smart phones.

Applicability of CO2 Extinguishing System for Ships (질식사고 방지용 CO2 소화설비의 선박 적용성)

  • Ha, Yeon Chul;Seo, Jung Kwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.4
    • /
    • pp.294-300
    • /
    • 2017
  • The offshore installations and ships are the structures most likely to be exposed to hazards such as hydrocarbon fire and/or explosion. Developing proactive measures to prevent the escalation of such events thus requires detailed knowledge of the related phenomena and their consequences. $CO_2$ extinguishing systems are extensively used for fire accidents of on-and offshore installations because of outstanding performance and low cost. There is, however, the risk of carbon dioxide system which enumerates many of the fatalities by suffocation associated with industrial fire protection requirements. Therefore, the aim of this study is to perform the prediction of fire suppression characteristics of the carbon dioxide system in realistic enclosed compartment area of ships and propose $CO_2$ extinguish fire fighting system for preventing suffocation accidents during fire fighting. According to CFD calculations, it can be observed and assessed that various fire profiles with $CO_2$ and $O_2$ mole fraction in the target enclosed compartment area are applicable within the proposed system. Additionally, the design of fire safety system of ships and offshore installations can utilize ventilation system and/or layout arrangement through the proposed system.

Development of a Bath Assistive System with Water Temperature Monitoring to Prevent Heart Attack (수온 모니터링 기능을 탑재한 심장마비 방지용 목욕 보조 시스템)

  • Kang, So Myoung;Wei, Qun
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.242-249
    • /
    • 2019
  • Old people and patients with cardiovascular disease could die of a heart attack in the bath with heated water for a long time. Various researches have been studied to prevent these accidents from happening such as measuring the ECG signal when taking bath. However, these devices are hard to use and the higher price is not easily accepted by the public. In this paper, a low-cost and use-friendly, real time high precision water temperature monitoring device to prevent heart attack in the bath was developed. The device with waterproof design that lets the device can float on the surface of the water, and an accurate way to make water temperature measurement method was proposed by this paper that is immerging the sensor into water with 4cm depth to measure the temperature of underwater. The manufactured device was conducted to two experiments; one was to verify the basic functions of the device, and another one was for compare the proposed device with commercial products for monitoring the water temperature in the bathtub. As the experimental results shown, the proposed device has stable performance for the water temperature measurement and communicating with laptop in wireless.

Education Method for Basic Programming Subject through Physical Computing (피지컬 컴퓨팅을 통한 기초 프로그래밍 교육 방법)

  • Hur, Kyeong;Sohn, Won-Sung
    • Journal of Practical Engineering Education
    • /
    • v.9 no.2
    • /
    • pp.139-148
    • /
    • 2017
  • As the connection between objects and computers becomes easier, learning using physical computing is presented as a good alternative to solve the problems raised in programming education for beginners. In this paper, we propose a training method that can be applied to basic programming courses for beginners. To do this, we will proceed with a basic programming lecture based on the physical computing method. Currently, physical computing courses focus on various input sensor connection methods and output device control. However, the content of programming education using physical computing materials is lacking. In this paper, we proposed and tested a teaching method that is used in programming education by using low cost materials used in physical computing.