• 제목/요약/키워드: low voltage circuit-breakers

검색결과 60건 처리시간 0.021초

30AF 차단기 순시 Trip 동작 특성분석을 통한 저압차단기의 안전성 개선방안 (A Safety Improvement of Low Voltage Circuit-breakers through Analysis of Instantaneous Trip Characteristics of 30AF Circuit-Breakers)

  • 김주철;임정균;이상중
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.78-83
    • /
    • 2010
  • The domestic 30AFs that are currently being produced show many problems due to different instantaneous trip characteristics in case of short-circuit. The troubles may cause explosion by excessive short-circuit capacities and arc emission, which results in a wide range of blackout. The function and safety of the low voltage circuit breakers installed before the end load are very important. This paper presents an idea on the safety improvement of the low voltage circuit-breakers through the analysis of instantaneous trip characteristics of domestic 30AF circuit-breakers.

저압용 IEC 차단기와 국내 차단기 혼용방안에 관한 연구 (The Study About Low Voltage Circuit Breaker Mix Method Between IEC Circuit Breaker and Domestic Circuit Breaker)

  • 정진수;김한상;한운기;김선구;박찬엄
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.905-909
    • /
    • 2012
  • Recent WTO/TBT agreement was adopted by the IEC domestic. For this reason, low voltage electrical equipment was many Confusion arises. Low voltage circuit was also one of these. The case of low voltage circuit, existing domestic circuit breakers and circuit breakers IEC curve differs from the behavior of each other. If low voltage circuit breaker wrong facility, circuit breaker malfunction may occur due to the large property damage. In this paper, to solve these problems domestic circuit breakers and circuit breaker operation IEC curves were analyzed. And, through experiments suggested compatible breaker way.

저압 30AF 차단기의 순시 Trip동작 특성시험 및 분석 (A Test and Analysis of Instantaneous Trip Characteristics of Low Voltage 30AF Circuit Breakers)

  • 김주철;이상중
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.364-367
    • /
    • 2009
  • 현재 국내에서 제조되는 저압 30AF(Ampere Frame) 소형 차단기의 경우 선로 단락사고 시 특성에 따라 순시 (Instantaneous) 동작이 다르게 반응함으로써 정전범위 확대, 정격단락차단용량(Rated short-circuit breaking capacities) 초과로 인한 폭발 및 Trip시 Arc방출 등 많은 문제점을 보이고 있다. 최종부하의 전단에 설치되는 저압차단기(Low voltage circuit-breakers)는 그 기능 및 역할이 큰 만큼 안전성을 중대시키는 것이 매우 중요하다. 본 논문은 국내에서 제조되는 30AF 소형 차단기의 사고유형과 제조사별 순시 Trip 동작속도의 시험 data를 확보하여 이를 분석하였다. 이는 향후 저압차단기의 안전에 관한 규격개정에 활용될 수 있을 것으로 사료된다.

  • PDF

가속 열화 시험에 따른 저압용 차단기의 물리적 특성에 관한 연구 (A Study on the Physical Characteristics of the Low-voltage Circuit Breaker Based on the Accelerated Degradation Test)

  • 강신동;김재호
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.1-8
    • /
    • 2022
  • This study analyzed the characteristics of insulation resistance and operating time based on an accelerated degradation test of a low-voltage circuit breaker. The experimental sample used a molded case circuit breaker (MCCB) and an earth leakage circuit breaker (ELCB). After measuring the insulation resistance of the circuit breakers, the leakage current was affected by an external rather than an internal structure. Furthermore, the insulation resistance of the circuit breakers with accelerated degradation was measured using a Megger insulation tester. In the accelerated degradation test, aging times of five, ten, 15, and 20 years were applied according to a temperature derived using the Arrhenius equation. Circuit breakers with an equivalent life of ten, 15, and 20 years had increased insulation resistance compared to those with less degradation time. In particular, the circuit breaker with an equivalent life of ten years had the highest insulation resistance. Component analysis of the circuit breaker manufactured through an accelerated degradation test confirmed that the timing of the increase in insulation resistance and the time of additive loss were the same. Finally, after analyzing the operating time of the circuit breakers with degradation, it was confirmed that the MCCB did not change, but the ELCB breaker failed.

저압 배선용 차단기용 섬유강화 복합재료 개발(I) (Development on the fiber-reinforced materials for low-voltage circuit breakers(I))

  • 이창용;송태헌;김진수;김덕중;이두희;이관희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.127-129
    • /
    • 2002
  • A new type of fiber-reinforced polymeric materials for the main body and the arc chamber of the low-voltage circuit breakers was developed. The tensile and the flectional strength of the three kinds of thermoplastic resins for the cover of MCCBs(Molded case circuit breakers) increase much higher than those made of BMC that has been used. In a high current-breaking test, an experimental MCCB with the new insulating material showed no-cracks on the bodies.

  • PDF

저압전기기기의 보호를 위한 전류동작형 누전차단기의 특성에 관한 연구 (The Study on the Characteristics of Leakage Circuit Breakers in Protection of the Low Voltage Electrical Apparatus)

  • 김은배;오철수
    • 전기의세계
    • /
    • 제25권4호
    • /
    • pp.59-62
    • /
    • 1976
  • This study on the characteristics of the leakage circuit breakers handles the rolls of each itemized parts of the mentioned apparatus and their influence in determining of the characteristic curve of leakage circuit breaker. Furthermore the differential current transforms in the mentioned apparatus for detecting the fault is handled as a heavy point.

  • PDF

가연물 특성에 따른 저압용 차단기의 스위치 아크에 의한 화재특성 (Fire Characteristics of Circuit Breakers for Low Voltage during Switching Arcs according to the Characteristics of Combustibles)

  • 김동우;이기연;김동욱;김향근;최충석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.37-38
    • /
    • 2006
  • In this paper, the fire characteristics of circuit breakers for low voltage during switching arcs were analyzed according to the characteristics of combustible materials. Arc dispersion and ignition process were taken by high speed imaging system and digital camera. In this experiment, four resistors were connected as loads. To discover the fire characteristics of circuit breakers by combustible materials, ethanol and cotton were installed as combustibles near contacts respectively. In case of ethanol, fire broke out near the contacts while switch was turned on and turned off. Whereas, in case of cotton, fire broke out near deteriorated contacts while switch was turned off.

  • PDF

배선용 차단기의 전자 반발력에 관한 연구 (Analysis of Electromagnetic Repulse Forces of MCCB)

  • 김길수;임기조;강성화;조현길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.593-596
    • /
    • 2001
  • It is necessary for calculation of repulsion forces acting on the closed electric contacts flowing over-current, e.g. inrush current and overload currents, to do optimum design of switching devices. In this paper, the farces and flux densities generated by currents at the contact point when circuit breakers are in closed state are obtained by using 3D finite element methode. To be convinced of the results, we measure electrogmanetic repulsion forces on contacts by measuring voltage between opened contacts in MCCB.

  • PDF

IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰 (Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364)

  • 김두웅;류규상;김한수;신대성;류기환;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.

분광기법을 이용한 저압 차단기용 소호재료 특성연구 (Investigation of Arc Quenching Material for Low Voltage Circuit Breaker using Spectroscopic Method)

  • 이상엽;정영우;박홍태;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1665-1667
    • /
    • 2003
  • Recently, a breaking capacity increases with breaking method using gas pressure from ablation materials in low voltage circuit breakers. In this paper, we investigated arc quenching materials with spectroscopic method. Especially, Hydrogen spectrum was investigated because its dielectric characteristics are better than other gases. We selected two arc quenching materials, UP and PA6, that use in circuit breakers. They had hydrogen spectrums, but PA6 was better than UP in the qualitative aspect.

  • PDF