• 제목/요약/키워드: low voltage cables

검색결과 54건 처리시간 0.026초

초고압 XLPE 케이블 금속 차폐층 고찰 (A study or Metallic sheath for Extra-high voltage XLPE cable)

  • 최창수;이갑중;정무영;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1652-1654
    • /
    • 1994
  • The Extra-high voltage XLPE cable is characterized by low transmission loss, large capacity, and high reliability. Conventionally, for XLPE cables of l54kV and above, aluminium sheath was used to be moisture barrier (thus preventing water tree deterioration of the insulation) and to protect cable core from physical stresses. However, as transmission capacity of the cable increases, so does the cable diameter and the corresponding aluminium sheath outer diameter and thickness. As a result, eddy-current loss in the sheath is increased, limiting the maximum current capacity of the cable itself. As an alternative to aluminium sheath, we have adopted stainless steel sheath with non-magnetic properties and a large resistivity, The new XLPE cable with stainless-steel sheath (CSZV cable) has drastically reduced eddy-current loss in the sheath.

  • PDF

전력케이블 진단을 위한 부분방전 검출장치의 설계 및 제작 (Design and Fabrication of a PD Detector for Power Cable Diagnosis)

  • 송재용;서황동;길경석;한문섭;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.777-782
    • /
    • 2005
  • In this paper, we designed and fabricated a partial discharge (PD) detector to diagnose the soundness of CNCV cables by analyzing PD pulses and to predict discharge locations. The PD detector is consisted of a coupling network with a discharge free capacitor and a detection impedance, a voltage follower and a low noise amplifier. Lower cut-off frequency of the detector is adjusted at 175kHz to block AC voltage and to pass discharge pulse only. The discharge location could be obtained by the time of arrival method using travelling wave propagation theory. In a laboratory test on an eighty meter CV cable, we could position the discharge location within a two meter error.

  • PDF

복합고체절연물의 극저온 절연성능 평가를 위한 임펄스 내전압시험 (Impulse Tests for a Composite Solid Insulator for High Voltage Superconducting Power Applications)

  • 김우석;유승덕;현옥배;김혜림;임성우;양성은;김희선
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.24-27
    • /
    • 2011
  • High voltage insulation in cryogenic environment is one of big issues for development of superconducting power application, such as superconducting fault current limiter, transformer, transmission cable, and so on. We had proposed a composite solid insulator composed of plastics and polymer insulation sheets for a use of high voltage superconducting power applications. It is well known that the G10 FRP keeps its mechanical strength at very low temperature and the PPLP is very good insulator adopted as insulations for superconducting transmission cables. The composition of these two materials will show very good electrical and mechanical properties adequate for the insulation components of superconducting power applications, such as bushing, insulation barrier, and even for a cryostat. Dielectric strengths of prepared samples were measured at the temperature of boiling point of liquid nitrogen at atmospheric pressure, which will be presented in this paper to show a usefulness of this technique.

초고압 XLPE 전력케이블용 Prefabricated Joint 및 접속기술 동향 (Trends of Prefabricated Joints and their Jointing Techniques for EHV XLPE-insulated Power Cables)

  • 김영;성정규;한창석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1608-1610
    • /
    • 1998
  • An oil-filled paper-insulated power cable and a XLPE-insulated power cable have been mainly applied as an extra-high-voltage underground power cable. But in recent the XLPE cable has been applied more widely than the OF cable, because of its advantages, such as the low-cost and simple installation. In general two types, molded and prefabricated, of straight joints are applied for the XLPE cables. For a tape-molded joint, one of molded joints, its electrical properties are excellent, but it has some disadvantages, such as a long working time. high skill of workers and the high cost of jointing equipments. For a prefabricated joint, developed and applied in Europe and Japan, its working time is short, its jointing procedures are simple, and its quality control is easy, but its prices are very high. In Korea the development of a compression-type PJ will be finished in the near future, and studies of its jointing techniques and equipments is actively going on. This paper describes the design and construction of the PJ, the jointing procedures and techniques for the PJ, and its future trends.

  • PDF

Improved Reactive Power Sharing for Parallel-operated Inverters in Islanded Microgrids

  • Issa, Walid;Sharkh, Suleiman;Mallick, Tapas;Abusara, Mohammad
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1152-1162
    • /
    • 2016
  • The unequal impedances of the interconnecting cables between paralleled inverters in the island mode of microgrids cause inaccurate reactive power sharing when the traditional droop control is used. Many studies in the literature adopt low speed communications between the inverters and the central control unit to overcome this problem. However, the losses of this communication link can be very detrimental to the performance of the controller. This paper proposes an improved reactive power-sharing control method. It employs infrequent measurements of the voltage at the point of common coupling (PCC) to estimate the output impedance between the inverters and the PCC and then readjust the voltage droop controller gains accordingly. The controller then reverts to being a traditional droop controller using the newly calculated gains. This increases the immunity of the controller against any losses in the communication links between the central control unit and the inverters. The capability of the proposed control method has been demonstrated by simulation and experimental results using a laboratory scale microgrid.

원자력발전소 고압케이블 열화진단에 관한 연구 (Study on Diagnosis of High Voltage Cables for Nuclear Power Plant)

  • 하체웅;주광호;한성흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2061-2062
    • /
    • 2011
  • 국내 원자력발전소에 설치되어 있는 고압케이블은 장기운전에 따라 열화진단 및 유지보수의 필요성이 증대되고 있다. 주기적 안전성 평가(Periodic Safety Review) 및 계속운전과 관련하여서도 고압케이블의 관리방안이 지속적으로 요구되고 있다. 본 논문에서는 원자력발전소에 설치되어 있는 13.8kV급 고압케이블의 건전성을 확인하기 위하여 원자력발전소 계획예방정비 중 열화진단을 수행한 결과를 소개하고 있다. 특히 미국 NRC(Nuclear Regulatory Commission)에서는 케이블 진단 기법 11가지를 권고하고 있는데 본 논문에서는 그 중 국내 원자력발전소에 적용이 가능한 최신 케이블 진단 기술인 HFCT(High Frequency Current Transformer)를 이용한 부분방전(Partial Discharge ; PD) 측정, VLF(Very Low Frequency) 장치를 이용한 $Tan{\delta}$ 측정 및 열화상카메라를 이용한 케이블 온도 측정을 사용하여 고압 케이블 진단을 실시하였고, 그 결과를 서술하였다.

  • PDF

저압 절연전선의 허용전류 계산을 위한 열적 파라메타 검토 (The Investigation of the Thermal Parameters of Calculating Ampacity of Low-Voltage Insulated Cables)

  • 정성환;남기영;이재덕;최상봉;류희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.272-273
    • /
    • 2006
  • Recently KS standards being kept in step with IEC standard in electrical safety. This paper examines thermal parameters of KS C IEC 60364-5-523(2002) to calculating the ampacity of insulated cable at 1kV below.

  • PDF

액체질소에서 절연지 및 mini-model 케이블의 전기절연 특성 (The Electric Insulation Characteristics of the Insulation Paper and Mini-model Cable in Liquid Nitrogen)

  • 곽동순;김영석;정종만;김해종;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.224-227
    • /
    • 2003
  • According to the increasing power demands for the power transmission of major cities, HTS power cables which have large current capacity and low power loss will be needed. In this paper we have studied breakdown voltage properties of paper/liquid composite insulating system for HTS cable insulation. And we measured the dielectric loss(tan$\delta$) of mini-model cable. From results, the insulation paper-ice composite insulation system is thought to be one of good candidate for the electrical insulating system at cryogenic temperature.

  • PDF

세라믹 메탈할라이드 램프용 안정기의 점화기 설계 방법 (Igniter design methods of the ballasts for Ceramic Metal Halide lamp)

  • 박종연;최왕섭
    • 산업기술연구
    • /
    • 제30권A호
    • /
    • pp.75-81
    • /
    • 2010
  • We described the operating principles of two different type of igniters for lightning of Ceramic Metal Halide Lamp(CMHL) and also provide some useful comparisons. One is for magnetic ballast, the other one is for electronic ballast which operates lamp by low-frequency square-waveform. Ignition voltage of lamp depends on the structure of igniter, such as the length and electrical characteristics of cable, which make troubles for ignition in real sites. Therefore, we measured and analyzed ignition voltages from igniters which are used in magnetic and electronic ballast in cables at a distance of 5 meters between a lamp and a igniter to suggests an applicable solution in real sites.

  • PDF

저압 지중케이블의 토양 열저항률 적용에 관한 연구 (A Study on the Apply to Soil Thermal Resistivity of Low-Voltage Underground Power Cables)

  • 이주철;김기현;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.65-70
    • /
    • 2012
  • The current-carrying capacities in IEC standards for underground refers to a soil thermal resistivity of 2.5[$K{\cdot}m/W$] where no measured data are available. But this value is considered too conservative and may not justifiable economically as to need precaution in using the value. In this paper, the standard practices on the application of soil thermal resistivity of some countries(UK, USA etc) are surveyed and proposed a reasonable representative value 1.0[$K{\cdot}m/W$] of soil thermal resistivity considering the domestic soil thermal properties with regard to the application of IEC standard.