• 제목/요약/키워드: low temperature-long time

검색결과 392건 처리시간 0.038초

A Study on Optimal Dye-coating Conditions to Reduce Dye-adsorption Time with Improved DSSC Efficiency

  • 서영호;최은창;홍병유
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.481.1-481.1
    • /
    • 2014
  • Dye-sensitized solar cell (DSSC) has been extensively investigated as the next generation energy source. Despite attractive features of simple fabrication process and its economical efficiency, there are some problems such as low efficiency and low long-term stability. Many groups have attempted the proposed way to improve the cell efficiency and long-term stability such as low recombination rate between $TiO_2$ surface and electrolyte, the development of new dye molecules capable of light adsorption as broadly as possible, the fabrication of a solid-state DSSC by replacing the liquid electrolyte, and protective coating on glass. In this work, we confirmed new dye-coating conditions to maximize the dye adsorption between the dye and $TiO_2$ nanoparticle surface. The experiment results coating conditions with the coating temperature of $70^{\circ}C$, the dye concentration of 10 mM and the coating time of 3 min. Conditions have two times, three times cycle the experiment in progress efficiency rises.

  • PDF

Polyacrylamide Gel 전기영동법에 의한 생유 및 살균처리유의 Whey 단백질 조성에 관한 비교 연구 (Comparative Studies on Protein Composition of Whey from Raw and Pasteurized Milk by Polyacrylamide Gel Electrophoresis)

  • 남궁석;우세홍;조종후
    • 한국식품위생안전성학회지
    • /
    • 제5권4호
    • /
    • pp.219-228
    • /
    • 1990
  • 생유와 시판되고 있는 저온살균유, 고온 순간살균유 및 초고온순간살균유 각 20예에 대하여 polyacrylamide 겔 전기 영동법으로 단백질의 조성을 구하였다. 생유의 Whey 단백질 중 혈청 albumin, ${\alpha}-lactalbumin,\;{\beta}-lactoglobulin$의 조성은 3.71 : 11.44 : 84.85였으며 저온 살균과 고온순간살균에 의하여 큰 변호를 주지 않았다. 그러나 초고온 순간 살균으로 조성비는 0 : 64.75 : 35.5로 변화되어 형청 albumin의 소실과 ${\beta}-lactoglobulin$의 감소를 보였다. 살균처리유의 냉장보존 3일째에 ${\alpha}-lactalumin과\;{\beta}-lactoglobulin$의 감소가 있었으나 $25^{\circ}C$ 실온보존에서는 변화가 없었다. 고온 순간 살균유는 실온보존 2일째에 혈청 albumin, 3일째에 ${\alpha}-Lactalbumin의$ 감소만 있었고 다른 Whey 단밸질은 보존온도에 관계없이 3일간 농도변화가 없었다. 초고온순간살균유는 냉장보존 2일째 혈청 albumin의 감소만 인정되었다.

  • PDF

Development of Long-Term Storage Technology for Chinese Cabbage - Physiological Characteristics of Postharvest Freshness in a Cooler with a Monitoring and Control Interface

  • Lim, Ki Taek;Kim, Jangho;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • 제39권3호
    • /
    • pp.194-204
    • /
    • 2014
  • Purpose: The aim of this study was to develop long-term storage technology for Chinese cabbage in order to extend the period of availability of freshly harvested products. The scope of the paper deals with the use of a cooler with a remote monitoring and control interface in conjunction with use of packaging film. Methods: A cooler with a real time monitoring system was designed as a low-temperature storage facility to control temperature and relative humidity (RH). The effects of storage in high-density polyethylene (HDPE) plastic boxes, 3% chitosan dipping solution, polypropylene film (PEF) with perforations, and mesh packaging bags on physiological responses were investigated. The optimal storage temperature and humidity for 120 days were below $0.5^{\circ}C$ and 90%, respectively. Physiological and biochemical features of cabbage quality were also analyzed: weight loss, texture, and sugar salinity, chlorophyll, reducing sugar, and vitamin C contents. Results: The cooler with a remote monitoring and control interface could be operated by an HMI program. A $0.5^{\circ}C$ temperature and 90% humidity could be remotely controlled within the cooler for 120 days. Postharvest freshness of Chinese cabbages could be maintained up to 120 days depending on the packaging method and operation of the remote monitoring system. In particular, wrapping the cabbages in PEF with perforations resulted in a less than a 5% deterioration in quality. This study provides evidence for efficient performance of plastic films in minimizing post-harvest deterioration and maintaining overall quality of cabbages stored under precise low-temperature conditions with remote monitoring and a control interface. Conclusions: Packaging with a modified plastic film and storage in a precisely controlled cooler with a remote monitoring and control interface could slow down the physiological factors that cause adverse quality changes and thereby increase the shelf life of Chinese cabbage.

CF8M과 SA508 용접재의 열화거동과 기계적특성 평가 (Evaluation of Mechanical Properties with Thermal Aging in CF8M/SA508 Welds)

  • 우승완;최영환;권재도
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1968-1973
    • /
    • 2004
  • Structural degradations are often experienced on the components of nuclear power plants in reactor pressure vessels (RPV) and steam generators (SG) when these components are exposed to high temperature and high pressure for a long period of time. Such conditions result in the change of microstructures and of mechanical properties of materials, which requires an evaluation of the safeguards related to structural integrity. In a primary reactor cooling system (RCS), a dissimilar weld zone exists between cast stainless steel (CF8M) in a pipe and low-alloy steel (SA508 cl.3) in a nozzle. Thermal aging is observed in CF8M as the RCS is exposed for a long period of time under the operating temperature between 290 and 33$0^{\circ}C$. Under the same conditions, it is well known that degradation is not observed in low alloy steel. An investigation of the effect of thermal aging on the various mechanical properties of the dissimilar weld zone is required. The purpose of the present investigation is to find the effect of thermal aging on the dissimilar weld zone. The specimens are prepared by an artificially accelerated aging technique maintained for various times at 43$0^{\circ}C$, respectively. Then, The various mechanical test for the dissimilar welds are performed.

Structural Changes in Isothermal Crystallization Processes of Synthetic Polymers Studied by Time-Resolved Measurements of Synchrotron-Sourced X-Ray Scatterings and Vibrational Spectra

  • Tashiro, Kohji;Hama, Hisakatsu
    • Macromolecular Research
    • /
    • 제12권1호
    • /
    • pp.1-10
    • /
    • 2004
  • The structural changes occurring in the isothermal crystallization processes of polyethylene (PE), poly-oxymethylene (POM), and vinylidene fluoridetrifluoroethylene (VDFTrFE) copolymer have been reviewed on the basis of our recent experimental data collected by the time-resolved measurements of synchrotron-sourced wide-angle (WAXS) and small-angle X-ray scatterings (SAXS) and infrared spectra. The temperature jump from the melt to a crystallization temperature could be measured at a cooling rate of 600-1,000 $^{\circ}C$/min, during which we collected the WAXS, SAXS, and infrared spectral data successfully at time intervals of ca. 10 sec. In the case of PE, the infrared spectral data clarified the generation of chain segments of partially disordered trans conformations immediately after the jump. These segments then became transformed into more-regular all-trans-zigzag forms, followed by the formation of an orthorhombic crystal lattice. At this stage, the generation of a stacked lamella structure having an 800-${\AA}$-long period was detected in the SAXS data. This structure was found to transfer successively to a more densely packed lamella structure having a 400-${\AA}$-long period as a result of the secondary crystallization of the amorphous region in-between the original lamellae. As for POM, the formation process of a stacked lamella structure was essentially the same as that mentioned above for PE, as evidenced from the analysis of SAXS and WAXS data. The observation of morphology-sensitive infrared bands revealed the evolution of fully extended helical chains after the generation of lamella having folded chain structures. We speculate that these extended chains exist as taut tie chains passing continuously through the neighboring lamellae. In the isothermal crystallization of VDFTrFE copolymer from the melt, a paraelectric high-temperature phase was detected at first and then it transferred into the ferroelectric low-temperature phase at a later stage. By analyzing the reflection profile of the WAXS data, the structural ordering in the high-temperature phase and the ferroelectric phase transition to the low-temperature phase of the multi-domain structure were traced successfully.

Aspects of spike damage by cold stress during young spike development period in wheat

  • Ahn, Seunghyun;Kim, Deawook;Lee, Hyeonseok;Jeong, Jaehyeok;Jeong, Hanyong;Hwang, Woonha;Choi, Kyungjin;Park, Hongkyu;Youn, Jongtag
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.199-199
    • /
    • 2017
  • This study investigated the aspects of damage due to low temperature treatment in order to establish the damage criterion according to low temperature invasion during regeneration period in wheat after regeneration period in the early spring. We cultivated wheat cultivar 'Geumgang' in Wagner pots and treated them with three types of low temperature, and the gradual temperature change program was set in a low temperature incubator for 12.5 h per day for 5 days during the night time when the length of young spikes was about 1 mm. All treatments except for the control were treated in 5 steps for each temperature. Treatment 1 was treated at the lowest temperature $-5^{\circ}C$ for 5 h, treatment 2 for 7 h at $-5^{\circ}C$, and treatment 3 for 9 h at $-5^{\circ}C$. The most common type of damage was partial infertility, and there were some discolored spikes. The damage rate of wheat spikes treated at $-5^{\circ}C$ for 9 h was the highest, while the damage rates of wheat sprouts treated at 5h and 7h were not different from each other. It was found that the damage of wheat spikes exposed to low temperatures for a long time was large. It is necessary to investigate the aspects of spike damage by duration days of low temperature.

  • PDF

솔벤트 증기처리 Reflow를 이용한 폴리머 마이크로 렌즈 제작 및 특성고찰 (Fabrication and Characterization of Polymer Microlens using Solvent-vapor-assisted Reflow)

  • 양승우;김신형;김보현;조영학
    • 한국정밀공학회지
    • /
    • 제32권3호
    • /
    • pp.299-305
    • /
    • 2015
  • In this paper, we propose a simple and low-cost fabrication method of polymer microlens using solvent-vapor-assisted reflow (SVAR). Metal molds for replication of polymer were fabricated using micro milling and the cylindrical shape of polymer was imprinted using hot-embossing process. The cylindrical shape of polymer was changed to hemispherical lens shape by SVAR. The characteristics of fabricated microlens were evaluated according to the condition of SVAR such as temperature and time. The focal length of polymer microlens could be controlled more easily in low-temperature and long-time condition than in high-temperature and short-time condition. That is, the level of concentrated light to focal point could be improved through the control of temperature and time. Also, we confirmed that toluene was more appropriate solvent than acetone in fabrication of PMMA polymer microlens using SVAR.

저온에서 생물활성탄의 기질제거특성 (Substrate Removal Characteristics for Low Temperature by Biological Activated Carbon)

  • 류성호;박중현
    • 상하수도학회지
    • /
    • 제11권2호
    • /
    • pp.76-93
    • /
    • 1997
  • Activated carbon is widely used for the treatment of water, wastewater and other liquid wastes. Biological activated carbon (BAC) process is water and wastewater treatment process developed in the 1970's. In addition to activated carbon adsorption, biodegradation organic pollutants occurs in the BAC bed where a large amount of aerobic biomass grows. This results in a long operation time of the carbon before having to be regenerated and thus a low treatment cost. Although the BAC process has been widely used, its mechanisms have not been well understood, especially the relationship between biodegradation and carbon adsorption, whether these two reactions can promote each other or whether they just simultaneously exist in the BAC bed. Also, the phenomenon of bioregeneration has been confused that previously occupied adsorption sites appear to be made available through the actions of microorganisms. And that, because biological process is influenced by low temperature, the mechanism of the BAC process is also effected by temperature variation in our country of winter temperature near the freezing point. Therefore, the objective of this study examines closely the mechanism of the BAC process by temperature variation using phenol as substrate. From this study, biological activated carbon is good substrate removal better than non adsorbing materials (charcoal, sand) as temperature variation, especially low temperature(near $5^{\circ}C$).

  • PDF

HEMT 소자 공정 연구 (Part 1. 금속박막 형성을 위한 Lift-off 공정연구) (A Study on HEMT Device Process (Part I. Lift-off Process for the Metallization))

  • 이종람;박성호;김진섭;마동성
    • 대한전자공학회논문지
    • /
    • 제26권10호
    • /
    • pp.1535-1544
    • /
    • 1989
  • The overhang structure of photoresist in optical lithography was studied for the metallization of GaAs-related devices throughout lift-off method. Optical contact aligner with a dose of 8.5 m J/cm\ulcornerand with a wavelength of 300mm was used for ultraviolet exposure of single layer of S1400-27 photoresist. The overhang thickness shows a linear relationship with the soaking time in monochlorobenzene, which its magnitude becomes high at elevated softbake temperature. Such process conditions as a low softbake temperature, a long monochlorohbenzene soaking time and a little exposed energy make the development rate of photoresist lower. The optimum process conditions to obtain a target line-width, which include an appropriate overhang structure such as complete separation between the sidewall of photoresist pattern and the deposited metal edge, are determined as the softbake temperature of 64-74\ulcornerC, the monochlorobenzene soaking time of 10-15min, the ultraviolet exposure time of 70-100sec and the development time of 50-80sec.

  • PDF

진단용 초음파 검사시간에 따른 허벅지의 온도 변화에 관한 고찰 (A Study On Temperature Changes In Thigh According To Diagnostic Ultrasonography Scan Time)

  • 김지원;임현수
    • 한국방사선학회논문지
    • /
    • 제6권3호
    • /
    • pp.201-206
    • /
    • 2012
  • 진단적 초음파가 태아에 미치는 영향에 대하여는 대부분의 연구결과, 심각한 영향을 미칠 가능성이 매우 낮다고 보고되고 있으나, 장시간의 과도한 조사는 초음파가 인체조직에 온도 상승이나 물리적인 영향을 줄 수 있어 초음파 검사시간에 따라 허벅지의 온도 변화를 조사하여 태아 초음파 검사 시 영향이 없는 시간을 알아보았다. 그 결과 초음파 검사 전보다 40분 안에는 온도가 떨어졌고 50분에는 허벅지의 온도가 검사 전보다 $1^{\circ}C$이상 올라가는 것을 확인하였다. 그러므로 40분 안에 초음파 검사를 한다면 안전한 것으로 추론해 본다.