• 제목/요약/키워드: low span-to-depth ratio

검색결과 23건 처리시간 0.031초

Shear strength prediction of PRC coupling beams with low span-to-depth ratio

  • Tian, Jianbo;Shen, Dandan;Li, Shen;Jian, Zheng;Liu, Yunhe;Ren, Wengeng
    • Earthquakes and Structures
    • /
    • 제16권6호
    • /
    • pp.757-769
    • /
    • 2019
  • The seismic performance of a coupled shear wall system is governed by the shear resistances of its coupling beams. The plate-reinforced composite (PRC) coupling beam is a newly developed form of coupling beam that exhibits high deformation and energy dissipation capacities. In this study, the shear capacity of plate-reinforced composite coupling beams was investigated. The shear strengths of PRC coupling beams with low span-to-depth ratios were calculated using a softened strut-and-tie model. In addition, a shear mechanical model and calculating method were established in combination with a multi-strip model. Furthermore, a simplified formula was proposed to calculate the shear strengths of PRC coupling beams with low span-to-depth ratios. An analytical model was proposed based on the force mechanism of the composite coupling beam and was proven to exhibit adequate accuracy when compared with the available test results. The comparative results indicated that the new shear model exhibited more reasonable assessment accuracy and higher reliability. This method included a definite mechanical model and reasonably reflected the failure mechanisms of PRC coupling beams with low span-to-depth ratios not exceeding 2.5.

Seismic behavior of fiber reinforced cementitious composites coupling beams with conventional reinforcement

  • Liang, Xingwen;Xing, Pengtao
    • Earthquakes and Structures
    • /
    • 제14권3호
    • /
    • pp.261-271
    • /
    • 2018
  • Fiber reinforced cementitious composites (FRCC) materials that exhibit strain-hardening and multiple cracking properties under tension were recently developed as innovative building materials for construction. This study aims at exploring the use of FRCC on the seismic performance of coupling beams with conventional reinforcement. Experimental tests were conducted on seven FRCC precast coupling beams with small span-to-depth ratios and one ordinary concrete coupling beam for comparison. The crack and failure modes of the specimens under the low cycle reversed loading were observed, and the hysteretic characteristics, deformation capacity, energy dissipation capacity and stiffness degradation were also investigated. The results show that the FRCC coupling beams have good ductility and energy dissipation capacities compared with the ordinary concrete coupling beam. As the confinement stirrups and span-to-depth ratio increase, the deformation capacity and energy dissipation capacity of coupling beams can be improved significantly. Finally, based on the experimental analysis and shear mechanism, a formula for the shear capacity of the coupling beams with small span-to-depth ratios was also presented, and the calculated results agreed well with the experimental results.

Static and Fatigue Behavior of RC Beams Strengthened with Steel Plates

  • Oh, Byung-Hwan;Cho, Jae-Yeol;Cha, Soo-Won
    • KCI Concrete Journal
    • /
    • 제14권1호
    • /
    • pp.51-60
    • /
    • 2002
  • Strengthening of existing concrete structures is a major concern in recent years as the number of degraded structures increases. The purpose of this paper is to investigate the static and fatigue behavior of reinforced concrete (RC) beams strengthened with steel plates. To this end, a comprehensive test program has been set up and many series of strengthened beams have been tested. The major test variables include the plate thickness, adhesive thickness, and the shear-span to depth ratio. The test results indicate that the separation of plates is the dominant failure mechanism even for the full-span-length strengthened beams with steel plate. The theoretical ultimate load capacities for strengthened beams based on the full composite action of concrete beam and steel plate are found to be larger than the actual measured load capacities. The strengthened beams exhibit more dominant shear cracking as the shear-span to depth ratio decreases. The ultimate capacity of strengthened beams increases slightly with the increase of adhesive thickness, which may be caused by the late initiation of plate separation in the beams with thicker adhesive. A realistic concept of ductility for plate-strengthened beams is proposed in this study. It is seen that the strengthened beams show relatively low ductility compared with unstrengthened beams. The present study indicates that the strengthened beams exhibit much higher fatigue resistance than the unstrengthened beams. The increase of deflections of strengthened beams according to the number of load cycles is much smaller than that of unstrengthened beams. The present study provides very useful results for the realistic application of plate-strengthening method in reinforced concrete structures.

  • PDF

합성트러스 보의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance of Composite Truss Beam)

  • 박원섭;김흥열;김형준
    • 한국화재소방학회논문지
    • /
    • 제23권6호
    • /
    • pp.135-141
    • /
    • 2009
  • 합성트러스는 북미에서 고층건물 및 장지간 건축 구조물에 널리 사용되어지고 있는 구조물의 형태로 비슷한 다른 건축 구조에 비하여 빠른 시공 속도와 낮은 경간비와 자중비의 장점이 있다. 12~18m 경간 범위에서는 가장 경쟁력이 있는 구조물의 형태로 알려져 있다. WTC 붕괴 사고 이후, 화재 시 구조물의 내화거동에 관한 연구의 필요성이 부각됨에 따라 화재와 관계된 여러 분야에서의 연구가 세계적으로 활발하게 진행 중에 있다. 본 연구에서 수행된 실험에서 화염에 직접 노출된 트러스 강재 부재의 경우 짧은 가열시간에도 불구하고, $700^{\circ}C$ 이내의 온도 분포를 보이며 콘크리트 내부에 위치한 센서의 경우는 $200^{\circ}C$ 이내의 온도 분포를 보였다. 20mm 사재의 경우, 구조물의 처짐은 3분을 전후하여 빠른 처짐 분포를 보이며 파괴되었으나, 25mm, 35mm, 45mm 사재의 경우, 구조물은 파괴되지 않았으나 모두 15분 이내에 L/20의 처짐 기준에 도달하였다.

Direct Method에 의한 鐵筋콘크리트 二方向슬라브의 最適設計에 관한 硏究 (A Study on the Optimal Design Method of Reinforced Concrete Two Way Slabs)

  • 김용희;류홍열;박문호
    • 한국농공학회지
    • /
    • 제26권2호
    • /
    • pp.97-105
    • /
    • 1984
  • We have, at present, found some studies on the optimum design of reinforced concrete about the simple slab but very few about the multi-story and multi-span slab. The aim of this study is to make a optimum design of coalesced beam and column slab constructure. Some results of the evaluation by using the optimalized algorithm that was developed in this study are as follows. 1. Slab was mainly restricted by the constraint of effective depth, bending moment, and minimum steel ratio; especially the effective depth was the preceding crifical constraint. In the optimum design of slab, therefore, the constraint about the minimum thickness should be surely considered. 2. This optimum design is good economy as much as some 3.4&~6.2% compared with the conventional design method. 3. In most case, it was converged by 3 to 6 iteratin regardless of the highest or lowest value and only in case of N=1 and case 1, there is a little oscillation after the 3rd iteration but it makes no difference in taking either the highest or lowest value because the range of oscillation is low as much as about 1.2% of the total construction cost. 4. In this study the result seeking for constraints that make no difference in the least cost design shows that shear stress and maximum steel ration may not be considered in it. 5. Bending moment was converged by one time iteration regardless of the initial value, while steel ratio, in most case, by two times because both bending moment and steel ratio are the fuction of effective depth.

  • PDF

스트럿-타이 모델에 의한 고강도 철근콘크리트 깊은 보의 전단강도 예측에 관한 연구 (A Study on Shear Strength Prediction for High-Strength Reinforced Concrete Deep Beams Using Strut-and-Tie Model)

  • 이우진;서수연;윤승조;김성수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.918-923
    • /
    • 2003
  • Reinforced concrete deep beams are commonly used in many structural applications, including transfer girders, pile caps, foundation walls, and offshore structures. The existing design methods were developed and calibrated using normal strength concrete test results, and their applicability th HSC deep beams must be assessed. For the shear strength prediction of high-strength concrete(HSC) deep beams, this paper proposed Softened Strut-and-Tie Model(SSTM) considered HSC and bending moment effect. The shear strength predictions of the refined model, the formulas the ACI 318-02 Appendix A STM, and Eq. of ACI 318-99 11.8 are compared with the collected experimental data of 74 HSC deep beams with compressive strength in the range of 49-78MPa . It is shown the shear strength of deep beam calculated by those equations are conservative on comparing test results. The comparison shows that the performance of the proposed SSTM is better than the ACI Code approach for all the parameters under comparison. The parameters reviewed include concrete strength, the shear span-depth ratio, and the ratio of horizontal and vertical reinforcement. The proposed SSTM gave a mean predicted to experimental ratio of 0.99, 32 percent higher than ACI 318-02 Code, however with the low coefficient variation.

  • PDF

Experimental and numerical investigations on reinforcement arrangements in RC deep beams

  • Husem, Metin;Yilmaz, Mehmet;Cosgun, Suleyman I.
    • Advances in concrete construction
    • /
    • 제13권3호
    • /
    • pp.243-254
    • /
    • 2022
  • Reinforced concrete (RC) deep beams are critical structural elements used in offshore pile caps, rectangular cross-section water tanks, silo structures, transfer beams in high-rise buildings, and bent caps. As a result of the low shear span ratio to effective depth (a/d) in deep beams, arch action occurs, which leads to shear failure. Several studies have been carried out to improve the shear resistance of RC deep beams and avoid brittle fracture behavior in recent years. This study was performed to investigate the behavior of RC deep beams numerically and experimentally with different reinforcement arrangements. Deep beams with four different reinforcement arrangements were produced and tested under monotonic static loading in the study's scope. The horizontal and vertical shear reinforcement members were changed in the test specimens to obtain the effects of different reinforcement arrangements. However, the rebars used for tension and the vertical shear reinforcement ratio were constant. In addition, the behavior of each deep beam was obtained numerically with commercial finite element analysis (FEA) software ABAQUS, and the findings were compared with the experimental results. The results showed that the reinforcements placed diagonally significantly increased the load-carrying and energy absorption capacities of RC deep beams. Moreover, an apparent plastic plateau was seen in the load-displacement curves of these test specimens in question (DE-2 and DE-3). This finding also indicated that diagonally located reinforcements improve displacement ductility. Also, the numerical results showed that the FEM method could be used to accurately predict RC deep beams'behavior with different reinforcement arrangements.

Nonlinear behavior of deep reinforced concrete coupling beams

  • Zhao, Z.Z.;Kwan, A.K.H.
    • Structural Engineering and Mechanics
    • /
    • 제15권2호
    • /
    • pp.181-198
    • /
    • 2003
  • Six large scale models of conventionally reinforced concrete coupling beams with span/depth ratios ranging from 1.17 to 2.00 were tested under monotonically applied shear loads to study their nonlinear behavior using a newly developed test method that maintained equal rotations at the two ends of the coupling beam specimen and allowed for local deformations at the beam-wall joints. By conducting the tests under displacement control, the post-peak behavior and complete load-deflection curves of the coupling beams were obtained for investigation. It was found that after the appearance of flexural and shear cracks, a deep coupling beam would gradually transform itself from an ordinary beam to a truss composed of diagonal concrete struts and longitudinal and transverse steel reinforcement bars. Moreover, in a deep coupling beam, the local deformations at the beam-wall joints could contribute significantly (up to the order of 50%) to the total deflection of the coupling beam, especially at the post-peak stage. Finally, although a coupling beam failing in shear would have a relatively low ductility ratio of only 5 or even lower, a coupling beam failing in flexure could have a relatively high ductility ratio of 10 or higher.

Shear behavior of reinforced HPC beams made of a low cement content without shear reinforcements

  • Tang, Chao-Wei;Chen, Yu-Ping;Chen, How-Ji;Huang, Chung-Ho;Liu, Tsang-Hao
    • Computers and Concrete
    • /
    • 제11권1호
    • /
    • pp.21-37
    • /
    • 2013
  • High-performance concrete (HPC) usually has higher paste and lower coarse aggregate volumes than normal concrete. The lower aggregate content of HPC can affect the shear capacity of concrete members due to the formation of smooth fractured surfaces and the subsequent development of weak interface shear transfer. Therefore, an experimental investigation was conducted to study the shear strength and cracking behavior of full-scale reinforced beams made with low-cement-content high-performance concrete (LcHPC) as well as conventional HPC. A total of fourteen flexural reinforced concrete (RC) beams without shear reinforcements were tested under a two-point load until shear failure occurred. The primary design variables included the cement content, the shear span to effective depth ratio (a/d), and the tensile steel ratio (${\rho}_w$). The results indicate that LcHPC beams show comparable behaviors in crack and ultimate shear strength as compared with conventional HPC beams. Overall, the shear strength of LcHPC beams was found to be larger than that of corresponding HPC beams, particularly for an a/d value of 1.5. In addition, the crack and ultimate shear strength increased as a/d decreased or ${\rho}_w$ increased for both LcHPC beams and HPC beams. This investigation established that LcHPC is recommendable for structural concrete applications.

순환굵은골재 철근 콘크리트 보의 전단강도 분석 (An Analysis of the Shear Strength of Reinforced Concrete Beams with Recycled Coarse Aggregates)

  • 지상규;윤현도;송선화;최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.851-854
    • /
    • 2008
  • 순환골재의 사용은 매립을 줄이고 고갈되어 가는 천연골재의 대체자원으로 사용할 수 있어 친환경적인 방법이다. 그러나 기존연구에서는 낮은 품질의 순환골재를 사용하거나 작은 크기의 부재만을 연구하였다. 본 연구에서는 순환굵은골재의 치환율(0, 30, 60, 100%)과 전단보강근에 따른 철근콘크리트 보의 전단거동을 파악하기 위하여 총 6개의 보를 실험하였다. 실험결과 순환골재를 사용한 실험체는 전단보강근의 사용 유무에 관계없이 천연골재를 사용한 실험체와 대등한 전단강도를 나타내었다. 또한 본 연구와 기존 연구의 실험값을 전단경간비, 압축강도, 단면크기, 유효깊이에 따른 전단강도특성을 비교한 결과 순환골재 콘크리트는 천연골재 콘크리트와 유사한 전단강도특성을 나타내었다. 순환골재를 사용한 구조물의 순환골재를 사용한 구조물의 적용성을 검토하기 위하여 현행 KCI2007 규준식 및 Zsutty의 전단강도 계산 값을 실험결과와 비교한 결과 현행규준식은 전단강도를 안전측으로 평가하고 있어 순환골재를 사용한 실험체에도 적용 가능 할 수있는 것으로 판단된다.

  • PDF