• 제목/요약/키워드: low signal/noise ratio

검색결과 670건 처리시간 0.021초

7 T 자기공명영상시스템에서의 송수신 RF 공진기 최적화 (Transmit Receive RF Resonator Optimization at 7 T MRI System)

  • ;유형석
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1727-1730
    • /
    • 2016
  • Magnetic resonance imaging has a potential to produce clear anatomical as well as functional images of human body. However, the ability to diagnose is limited by signal to noise ratio (SNR) and the resolution of current medical systems. To remove the challenges prevalent due to the use of high field scanners, dedicated radio frequency coils are used. Transverse electromagnetic coils have an advantage of providing homogeneous magnetic field throughout the region but with low signal to noise ratio while surface coils have an advantage of providing higher signal to noise ratio but with low homogeneity. This research combines both the advantage into one by utilizing transmit only transverse electromagnetic radio frequency coils (8 channel) along with receive only surface coils (by varying the number) for better imaging of brain. A 7 Tesla 32-channel close fitting helmet shaped phased-array surface coils along with the combination of 8 channel transmit only transverse electromagnetic coils provided good homogeneity as well as significant SNR improvements throughout the human brain.

커프 신경전극을 위한 저잡음 증폭기 시스템 개발 (Development of a Low-Noise Amplifier System for Nerve Cuff Electrodes)

  • 송강일;추준욱;서준교;최귀원;유선국;윤인찬
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권1호
    • /
    • pp.45-54
    • /
    • 2011
  • Cuff electrodes have a benefit for chronic electroneurogram(ENG) recording while minimizing nerve damage. However, the ENG signals are usually contaminated by electromyogram(EMG) activity from the surrounding muscle, the thermal noise generated within the source resistance, and the electric noise generated primarily at the first stage of the amplifier. This paper proposes a new cuff electrode to reduce the interference of EMG signals. An additional middle electrode was placed at the center of cuff electrode. As a result, the proposed cuff electrode achieved a higher signal-to-interference ratio compared to the conventional tripolar cuff. The cuff electrode was then assembled together with closure, headstage, and hermetic case including electronic circuits. This paper also presents a lownoise amplifier system to improve signal-to-noise ratio. The circuit was designed based on the noise analysis to minimize the electronic noise. The result shows that the total noise of the amplifier was below $1{\mu}V_{rms}$ for a cuff impedance of $1\;k{\Omega}$ and the common-mode rejection ratio was 115 dB at 1 kHz. In the current study, the performance of nerve cuff electrode system was evaluated by monitoring afferent nerve signals under mechanical stimuli in a rat animal model.

변형된 역확산기 기반의 GPS 적응 간섭제거기의 출력 SINR 해석 (Output SINR Analysis of GPS Adaptive Interference Canceler Based on Modified Despreader)

  • 황석승
    • 한국전자통신학회논문지
    • /
    • 제9권2호
    • /
    • pp.195-202
    • /
    • 2014
  • 다양한 상업적, 군사적 방면에서 사용되고 있는 위성항법시스템(Global Positioning System: GPS)은 특정 사용자나 물체의 위치를 추정하기 위해 설계되었다. 정확한 위치추정을 위해 위성항법시스템은 최소 네 개의 위성으로부터 신호를 수신하여야 한다. GPS 수신기는 매우 낮은 신호-대-잡음 비(signal-to-noise ratio: SNR)에서 동작하며, GPS 신호에 비해 매우 높은 전력을 가지는 간섭신호들에 의해 위치추정 성능에 영향을 받을 수 있다. 본 논문에서는 고 전력 간섭들을 정확한 GPS 신호의 도래각(angle-of-arrival: AOA) 정보 없이 제거하는 변형된 역확산기(modified despreader) 기반의 다수개의 GPS 신호를 위한 적응 간섭제거기를 소개한다. 또한 변형된 역환산 빔형성기의 출력에 대한 신호-대-간섭 및 잡음 비(signal-to-interference and noise ratio: SINR)의 수학적 해석을 제공한다. 컴퓨터 시뮬레이션을 통해 고려된 GPS 수신기의 간섭제거성능과 SINR에 대한 수학적 해석을 확인한다.

흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교 (Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol)

  • 이원정;안봉선;박영선
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.84-89
    • /
    • 2012
  • 임상에서 사용하고 있는 흉부 CT촬영의 저선량 프로토콜과 표준선량 프로토콜 간의 선량과 화질을 비교 분석하였다. 흉부 저선량 프로토콜(120 kVp, 30 mAs)과 표준선량 프로토콜(120 kVp, 180 mAs)로 촬영($Brilliance^{TM}$ CT 16slice, PHILIPS)한 61명의 조영제를 사용하지 않은 영상에서 기관 분기부 위치의 종격동 영상을 본 연구를 위해 사용하였다. 상행대동맥과 가시아래근에서 CT number와 잡음을 측정하였고, Back-ground 잡음을 측정하여 신호대잡음비(signal-to-noise ratio. SNR)와 대조도잡음비(contrast-to-noise ratio, CNR)를 구하였다. 두부 아크릴 팬텀을 이용하여 선량을 측정하였고, 워터 팬텀으로 얻은 영상에서 CT number와 잡음을 측정하였다. 모든 측정은 3회 실시하여 평균값을 SPSS 프로그램(version 14.0)으로 분석하였고, 그래프는 시그마 플롯 프로그램(version10.0)을 사용하였다. 결과: 상행대동맥과 가시아래근에서 저선량 프로토콜 영상이 표준선량 프로토콜 영상 보다 유의하게 높은 잡음을 보였고, SNR과 CNR은 유의하게 낮았다. 두 영상에서 비만지수에 대한 잡음은 양의 관련성을 보였지만, SNR과 CNR은 음의 관련성을 보였다. 팬텀 결과에서 저선량 프로토콜의 선량이 표준선량 프로토콜 보다 유의하게 낮았지만(0.35 mGy vs. 1.95 mGy, p=0.008), 잡음은 저선량 프로토콜에서 유의하게 높았다(p=0.029). 저선량 프로토콜이 표준선량 프로토콜 보다 유의하게 낮은 선량을 보였지만, 화질 평가도 유의하게 낮은 결과를 보임으로서 임상에서 사용하는 저선량 프로토콜의 노출 선량은 화질을 고려하여 상향 조정할 필요가 있다.

흉부 전·후방향 검사 시 고관전압 및 산란선 후처리 소프트웨어 적용이 화질과 선량에 미치는 영향 (Effect of High Tube Voltage and Scatter Ray Post-processing Software on Image Quality and Radiation Dose During Chest Anteroposterior Radiography)

  • 김종석;주영철;이승근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.295-300
    • /
    • 2021
  • This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.

Speech Denoising via Low-Rank and Sparse Matrix Decomposition

  • Huang, Jianjun;Zhang, Xiongwei;Zhang, Yafei;Zou, Xia;Zeng, Li
    • ETRI Journal
    • /
    • 제36권1호
    • /
    • pp.167-170
    • /
    • 2014
  • In this letter, we propose an unsupervised framework for speech noise reduction based on the recent development of low-rank and sparse matrix decomposition. The proposed framework directly separates the speech signal from noisy speech by decomposing the noisy speech spectrogram into three submatrices: the noise structure matrix, the clean speech structure matrix, and the residual noise matrix. Evaluations on the Noisex-92 dataset show that the proposed method achieves a signal-to-distortion ratio approximately 2.48 dB and 3.23 dB higher than that of the robust principal component analysis method and the non-negative matrix factorization method, respectively, when the input SNR is -5 dB.

압축센싱 기법을 적용한 선박 수중 방사 소음 신호의 저주파 토널 탐지 (Detection of low frequency tonal signal of underwater radiated noise via compressive sensing)

  • 김진홍;심병효;안재균;김성일;홍우영
    • 한국음향학회지
    • /
    • 제37권1호
    • /
    • pp.39-45
    • /
    • 2018
  • 압축센싱을 적용하면 전체 신호의 차원 대비 실제 사용하는 신호의 차원이 작은 희소신호의 경우, 적은 수의 관측치를 통하여 빠른 시간 내에 복원이 가능하다. 수중 표적의 기어박스 및 보조 장치 등으로부터 방사되는 신호의 토널 주파수 성분들은 처리하고자 하는 주파수 대역에서 상대적으로 주파수 성분이 적다. 따라서 토널 신호는 주파수 영역 전체 대비 희소신호로 모델링 될 수 있으므로 희소 신호 복원 알고리듬인 S-OMP(Simultaneous-Orthogonal Matching Pursuit)를 이용하여 복원할 수 있다. 본 논문에서는 압축센싱 기법을 이용하여 수중 표적의 방사 소음 신호의 토널 주파수를 검출하는 기법을 제안하고 모의 실험을 통해 성능을 확인한다. 모의실험에서 기존의 FFT(Fast Fourier Transform) 임계치 기법을 이용한 방법에 비해 낮은 SNR(Signal to Noise Ratio)에서도 정확한 토널 성분을 추정 할 수 있음을 확인하였다.

GPS 재방송 재밍신호 검출을 위한 통합 의사잡음신호를 사용한 확장된 ELP 기법 (Extended Early-Late Phase Scheme using Combined Pseudo-Random Noise Signal to Detect GPS Repeat-Back Jamming Signals)

  • 유승수;염동진;지규인;김선용
    • 제어로봇시스템학회논문지
    • /
    • 제22권6호
    • /
    • pp.483-489
    • /
    • 2016
  • This paper proposes a repeat-back jamming signal detection scheme that utilizes a combined pseudo random noise signal that is effective for processing a global positioning system (GPS) repeat-back jamming signal with the early minus late phase scheme to alleviate any existing multipath signal detection. The proposed scheme uses the combined pseudo random noise signal to treat repeat-back jamming signals like similar multipath signals and can effectively detect a repeat-back jamming signal by applying the early minus late phase scheme to a combined pseudo random noise signal. Through a Monte-Carlo simulation, the detection probability of the proposed scheme is better than the one of the conventional scheme under low jamming to signal power ratio.

잡음환경에서의 바이모달 시스템을 위한 견실한 끝점검출 (Robust Endpoint Detection for Bimodal System in Noisy Environments)

  • 오현화;권홍석;손종목;진성일;배건성
    • 전자공학회논문지CI
    • /
    • 제40권5호
    • /
    • pp.289-297
    • /
    • 2003
  • 음성인식 시스템과 입술독해 시스템을 결합한 하여 음향학적 잡음에 대하여 안정된 성능을 갖는 바이모달(bimodal) 시스템을 구현한다. 바이모달 시스템의 성능은 두 인식 시스템의 성능뿐만 아니라 입력 신호의 끝점검출 성능에도 크게 영향을 받는다. 본 논문에서는 음성신호와 영상신호에서 끝점을 자각 자동 검출하여 입력 음성신호로부터 음성신호에서 추정한 신호대잡음비(signal-to-noise ratio: SNR)로 두 끝점검출 결과를 선택하는 방법을 제안한다. 즉 낮은 SNR에서는 영상신호로부터 검출된 끝점을 선택하고 높은 SNR에서는 음성신호로부터 검출된 끝점을 선택함으로써 음향학적 잡음에 대하여 견실하게 끝점을 검출한다. 제안한 끝점검출 방법이 적용된 바이모달 시스템이 강한 음향학적 잡음에 대하여 만족스러운 인식성능을 나타냄을 실험견과에서 확인할 수 있다.

낮은 SNR 다중 표적 환경에서의 iterative Joint Integrated Probabilistic Data Association을 이용한 표적추적 알고리즘 연구 (Study of Target Tracking Algorithm using iterative Joint Integrated Probabilistic Data Association in Low SNR Multi-Target Environments)

  • 김형준;송택렬
    • 한국군사과학기술학회지
    • /
    • 제23권3호
    • /
    • pp.204-212
    • /
    • 2020
  • For general target tracking works by receiving a set of measurements from sensor. However, if the SNR(Signal to Noise Ratio) is low due to small RCS(Radar Cross Section), caused by remote small targets, the target's information can be lost during signal processing. TBD(Track Before Detect) is an algorithm that performs target tracking without threshold for detection. That is, all sensor data is sent to the tracking system, which prevents the loss of the target's information by thresholding the signal intensity. On the other hand, using all sensor data inevitably leads to computational problems that can severely limit the application. In this paper, we propose an iterative Joint Integrated Probabilistic Data Association as a practical target tracking technique suitable for a low SNR multi-target environment with real time operation capability, and verify its performance through simulation studies.