• 제목/요약/키워드: low seismic regions

검색결과 74건 처리시간 0.027초

Identifying significant earthquake intensity measures for evaluating seismic damage and fragility of nuclear power plant structures

  • Nguyen, Duy-Duan;Thusa, Bidhek;Han, Tong-Seok;Lee, Tae-Hyung
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.192-205
    • /
    • 2020
  • Seismic design practices and seismic response analyses of civil structures and nuclear power plants (NPPs) have conventionally used the peak ground acceleration (PGA) or spectral acceleration (Sa) as an intensity measure (IM) of an earthquake. However, there are many other earthquake IMs that were proposed by various researchers. The aim of this study is to investigate the correlation between seismic responses of NPP components and 23 earthquake IMs and identify the best IMs for correlating with damage of NPP structures. Particularly, low- and high-frequency ground motion records are separately accounted in correlation analyses. An advanced power reactor NPP in Korea, APR1400, is selected for numerical analyses where containment and auxiliary buildings are modeled using SAP2000. Floor displacements and accelerations are monitored for the non- and base-isolated NPP structures while shear deformations of the base isolator are additionally monitored for the base-isolated NPP. A series of Pearson's correlation coefficients are calculated to recognize the correlation between each of the 23 earthquake IMs and responses of NPP structures. The numerical results demonstrate that there is a significant difference in the correlation between earthquake IMs and seismic responses of non-isolated NPP structures considering low- and high-frequency ground motion groups. Meanwhile, a trivial discrepancy of the correlation is observed in the case of the base-isolated NPP subjected to the two groups of ground motions. Moreover, a selection of PGA or Sa for seismic response analyses of NPP structures in the high-frequency seismic regions may not be the best option. Additionally, a set of fragility curves are thereafter developed for the base-isolated NPP based on the shear deformation of lead rubber bearing (LRB) with respect to the strongly correlated IMs. The results reveal that the probability of damage to the structure is higher for low-frequency earthquakes compared with that of high-frequency ground motions.

내풍설계된 초고층 철골중심가새골조의 지진응답 해석 (Seismic Response Analysis of Wind-Designed Concentrically Braced Steel Highrise Buildings)

  • 이철호;김선웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.60-67
    • /
    • 2004
  • The designer of a tall building even in moderate and low seismic regions should, in finalizing the desist consider the probable impact of the design basis earthquake on the selected structural system. In this study, seismic response analysis was conducted to evaluate the seismic performance of concentrically braced steel highrise buildings which were designed only for governing wind loading under moderate seismicity. The main purpose of this analysis was to see if the wind design would create a system whose elastic capacity clearly exceeds the probable demand as suggested by the design basis earthquake. The strength demand-to-capacity study revealed that the wind-designed steel highrise buildings with the aspect ratio of larger than five can withstand the design basis earthquake elastically by a sufficient margin due to the system over-strength resulting from the wind-serviceability criterion. The maximum story drift demand from the design basis earthquake was just 0.25% (or half the limit of Immediate Occupancy performance level in FEMA 273)

  • PDF

Minimum loading requirements for areas of low seismicity

  • Lam, Nelson T.K.;Tsang, Hing-Ho;Lumantarna, Elisa;Wilson, John L.
    • Earthquakes and Structures
    • /
    • 제11권4호
    • /
    • pp.539-561
    • /
    • 2016
  • The rate of occurrence of intraplate earthquake events has been surveyed around the globe to ascertain the average level of intraplate seismic activities on land. Elastic response spectra corresponding to various levels of averaged (uniform) seismicity for a return period of 2475 years have then been derived along with modifying factors that can be used to infer ground motion and spectral response parameters for other return period values. Estimates derived from the assumption of uniform seismicity are intended to identify the minimum level of design seismic hazard in intraplate regions. The probabilistic seismic hazard assessment presented in the paper involved the use of ground motion models that have been developed for regions of different tectonic and crustal classifications. The proposed minimum earthquake loading model is illustrated by the case study of Peninsular Malaysia which has been identified with a minimum effective peak ground acceleration (EPGA) of 0.1 g for a return period of 2475 years, or 0.07 g for a notional return period of 475 years.

동적거동에 기초한 약진지역 철골뼈대구조물의 내진설계 (Earthquake Resistant Design of a Steel Framed Structure in Low Seismic Regions Based on the Dynamic Behaviour)

  • 국승규
    • 한국지진공학회논문집
    • /
    • 제5권2호
    • /
    • pp.59-66
    • /
    • 2001
  • 구조물 내진설계의 개념은 기존요구조건이라는 조항으로 시방서에 규정되어 있으며 구조물이 지진발생시에 안전성과 경제성을 최대한 확보할 수 있으며 비선형시간 이력해석을 수행하여 자진시의 동적거동을 기술함으로써 확인할 수 있다. 내진설계에 보편적으로 적용하는 응답스펙트럼해석법은 선형해석법으로 구조물의 비선형동적거동의 영향을 거동계수로 반영하므로 파괴메카니즘 및 기본 요구조건의 만족여부를 거동계수를 구하는 과정으로 결정할 수 있다. 이 연구에서는 내진설계방식에 의해 설계된 약진지역에 의한 화학공장건물의 모델인 3차원 철골뼈대구조물을 선정하고 거동계수를 결정하는 과정을 수행하여 지진시의 동적거동을 확인하였다. 이 연구의 결과, 현 시방서의 응답스펙트럼해석법에 적용되는 거동계수는 강진지역의 구조물의 경우 기능성 및 안정성 한계를 제시하지만 약진지역 구조물의 경우는 실제 동적거동과 무관하다는것과 약진 지역에 위치한 구조물의 내진설계에는 시방서가 제시한 내진설계방식을 적용하는 것이 주요한 사항임을 확인하였다.

  • PDF

한정연성 철근콘크리트 교각의 유사동적 실험에 의한 내진 성능 평가 (Seismic Performance Evaluation of RC Bridge Piers with Limited Ductility by the Pseudo-Dynamic Test)

  • 정영수;박창규;박진영
    • 콘크리트학회논문집
    • /
    • 제15권5호
    • /
    • pp.705-714
    • /
    • 2003
  • 우리나라는 선진 외국에 비하여 늦은 1992년에 도로교 표준시방에 내진설계편이 도입되었다. 따라서, 1992년 이전에 설계된 교각들은 내진 설계가 되어있지 않음은 물론 시공편의상 소성힌지 구간에 주철근이 겹침이음 시공되어 현재에도 사용되고 있다. 또한, 현행 내진규정도 강진지역의 설계규정을 도입함으로써 중 약진 지역에 속하는 우리의 현실에 맞지 않아 현장에서 복잡한 철근배근을 요구함으로 시공성 및 경제성이 많이 떨어지고 있는 실정이다. 본 연구에서는 1992년 이전에 비내진 설계/시공되어 공용중인 원형 교각을 조사하여, 주철근이 겹침이음된 기준실험체(주철근비 1.01%, 심부구속철근비 0.13%) 1개를 실물크기와 유사하도록 직경 1.2m, 높이 4.8m로 제작하였으며, 또한 중 약진 지역에 속하는 우리나라의 실정을 감안하여 심부구속철근비를 비내진 규정의의 2.3배 현행 내진 설계규정의 0.32배에 해당하는 0.30%의 한정연성실험체 3개를 제작하여 유사동적 실험을 통하여 내진 연성도 평가를 하였다. 실험결과 비내진 실험체는 요구변위연성도 5를 만족시키지 못하였고, 한정연성 실험체의 경우는 현행 내진규정의 요구 변위연성도 5를 만족하는 것으로 나타났다.

중약진지역에 위치한 콘크리트교량의 수정내진 설계 (Modified Earthquake resistant design for a concrete bridge in the Low to moderated seismic Region)

  • 국승규
    • 한국지진공학회논문집
    • /
    • 제4권3호
    • /
    • pp.11-21
    • /
    • 2000
  • 구조물에 내진설계를 적용하는 목적은 지진에 노출되는 구조물에 안전성과 경제성을 고려한 파괴메카니즘을 부여하는 것이다. 내진설계에 보편적으로 적용하고 있는 응답스펙트럼해석법은 선형해석법으로 구조물의 비선형 동적거동에 의한 영향은 특정 계수로 반영한다. 그러나 기존의 내진설계시방서들이 강진지역에 있는 나라들에 의해 제정 및 개정되어 왔기 때문에 응답스펙트럼 해석법 뿐만 아니라 기타의 적용규정이 강진지역에 위치한 구조물의 상황만을 고려하여 제시되었다. 따라서 중약진지역에 위치한 구조물의 내진설계에 대한 별도의 연구가 요구되고 있다. 이 연구에서는 중약진지역에 위치한 콘크리트 교량을 선정하여 비선형 동적거동을 반영하는 계수를 결정하고 응답스펙트럼 해석법을 적용하였다. 연구 결과 바탕으로 중약진지역의 교량에 대해 내진설계의 목적을 만족하는 개선된 내진설계 절차를 제시하였다.

  • PDF

Simplified elastic design checks for torsionally balanced and unbalanced low-medium rise buildings in lower seismicity regions

  • Lam, Nelson T.K.;Wilson, John L.;Lumantarna, Elisa
    • Earthquakes and Structures
    • /
    • 제11권5호
    • /
    • pp.741-777
    • /
    • 2016
  • A simplified approach of assessing torsionally balanced (TB) and torsionally unbalanced (TU) low-medium rise buildings of up to 30 m in height is presented in this paper for regions of low-to-moderate seismicity. The Generalised Force Method of Analysis for TB buildings which is illustrated in the early part of the paper involves calculation of the deflection profile of the building in a 2D analysis in order that a capacity diagram can be constructed to intercept with the acceleration-displacement response spectrum diagram representing seismic actions. This approach of calculation on the planar model of a building which involves applying lateral forces to the building (waiving away the need of a dynamic analysis and yet obtaining similar results) has been adapted for determining the deflection behaviour of a TU building in the later part of the paper. Another key original contribution to knowledge is taking into account the strong dependence of the torsional response behaviour of the building on the periodic properties of the applied excitations in relation to the natural periods of vibration of the building. Many of the trends presented are not reflected in provisions of major codes of practices for the seismic design of buildings. The deflection behaviour of the building in response to displacement controlled (DC) excitations is in stark contrast to behaviour in acceleration controlled (AC), or velocity controlled (VC), conditions, and is much easier to generalise. Although DC conditions are rare with buildings not exceeding 30 m in height displacement estimates based on such conditions can be taken as upper bound estimates in order that a conservative prediction of the displacement profile at the edge of a TU building can be obtained conveniently by the use of a constant amplification factor to scale results from planar analysis.

Seismic evaluation of existing RC frames with wide beams using an energy-based approach

  • Benavent-Climent, A.;Zahran, R.
    • Earthquakes and Structures
    • /
    • 제1권1호
    • /
    • pp.93-108
    • /
    • 2010
  • This paper investigates the seismic performance of existing reinforced concrete frames with wide beams mainly designed for gravity loads, as typically found in the seismic-prone Mediterranean area before the introduction of modern codes. The seismic capacity is evaluated in terms of the overall amount of input energy that the frame can dissipate/absorb up to collapse. This approach provides a quantitative evaluation that can be useful for selecting and designing an appropriate retrofit strategy. Six prototype frames representative of past construction practices in the southern part of Spain are designed, and the corresponding non-linear numerical models are developed and calibrated with purposely conducted tests on wide beam-column subassemblages. The models are subjected to sixteen earthquake records until collapse by applying the incremental dynamic analysis method. It is found that the ultimate energy dissipation capacity at the story level is markedly low (about 1.36 times the product of the lateral yield strength and yield displacement of the story), giving values for the maximum amount of energy that the frame can dissipate which are from one fourth to half of that required in moderate-seismicity regions.

Mitigation of seismic drift response of braced frames using short yielding-core BRBs

  • Pandikkadavath, Muhamed Safeer;Sahoo, Dipti Ranjan
    • Steel and Composite Structures
    • /
    • 제23권3호
    • /
    • pp.285-302
    • /
    • 2017
  • Buckling-restrained braced frames (BRBFs) are commonly used as the lateral force-resisting systems in building structures in the seismic regions. The nearly-symmetric hysteretic response and the delayed brace core fracture of buckling-restrained braces (BRBs) under the axial cyclic loading provide the adequate lateral force and deformation capacity to BRBFs under the earthquake excitation. However, the smaller axial stiffness of BRBs result in the undesirable higher residual drift response of BRBFs in the post-earthquake scenario. Two alternative approaches are investigated in this study to improve the elastic axial stiffness of BRBs, namely, (i) by shortening the yielding cores of BRBs; and (ii) by reducing the BRB assemblies and adding the elastic brace segments in series. In order to obtain the limiting yielding core lengths of BRBs, a modified approach based on Coffin-Manson relationship and the higher mode compression buckling criteria has been proposed in this study. Both non-linear static and dynamic analyses are carried out to analytically evaluate the seismic response of BRBFs fitted with short-core BRBs of two medium-rise building frames. Analysis results showed that the proposed brace systems are effective in reducing the inter-story and residual drift response of braced frames without any significant change in the story shear and the displacement ductility demands.

RC기둥의 내진성능에 미치는 겹침 이음상세의 영향 (Effects of Lap Splice Details on Seismic Performance of RC Columns)

  • 김철구;박홍근;김태완;엄태성
    • 한국지진공학회논문집
    • /
    • 제20권6호
    • /
    • pp.351-360
    • /
    • 2016
  • In regions of low-to-moderate seismicity, various types of lap splices are used for longitudinal reinforcement of columns at the plastic hinge zones. The seismic performance of such lap spliced columns, such as strength, deformation capacity, and energy dissipation, is affected by material strengths, longitudinal re-bar size, confinement of hoops, lap splice location, and lap splice length. In the present study, cyclic loading tests were performed for columns using three types of lap splices (bottom offset bar splice, top offset bar splice, and splice without offset bend). Lap splice length($40d_b$ and $50d_b$) was also considered as test parameters. Ties with 90-degree end hooks were provided in the lap splice length. The test results showed that strength, deformation capacity, and energy dissipation of columns significantly differed depending on the details and the length of lap splices. The bottom offset bar splice showed high ductility and energy dissipation but low strength; on the other hand, the top offset bar splice and the splice without offset bend showed high strength but moderate ductility and energy dissipation.