• 제목/요약/키워드: low magnetic field

검색결과 790건 처리시간 0.039초

Effect of Bias Magnetic Field on Magnetoelectric Characteristics in Magnetostrictive/Piezoelectric Laminate Composites

  • Chen, Lei;Luo, Yulin
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.347-352
    • /
    • 2015
  • The magnetoelectric (ME) characteristics for Terfenol-D/PZT laminate composite dependence on bias magnetic field is investigated. At low frequency, ME response is determined by the piezomagnetic coefficient $d_{33,m}$ and the elastic compliance $s_{33}^H$ of magnetostrictive material, $d_{33,m}$ and $s_{33}^H$ for Terfenol-D are inherently nonlinear and dependent on $H_{dc}$, leading to the influence of $H_{dc}$ on low-frequency ME voltage coefficient. At resonance, the mechanical quality factor $Q_m$ dependences on $H_{dc}$ results in the differences between the low-frequency and resonant ME voltage coefficient with $H_{dc}$. In terms of ${\Delta}E$ effect, the resonant frequency shift is derived with respect to the bias magnetic field. Considering the nonlinear effect of magnetostrictive material and $Q_m$ dependence on $H_{dc}$c, it predicts the low-frequency and resonant ME voltage coefficients as a function of the dc bias magnetic field. A good agreement between the theoretical results and experimental data is obtained and it is found that ME characteristics dependence on $H_{dc}$ are mainly influenced by the nonlinear effect of magnetostrictive material.

정밀솔레노이드를 사용한 저자장 표준시스템 제작 (Construction of a Low Magnetic Field Standard System Using a Precision Solenoid)

  • 박포규;손대락;우병칠;김창석
    • 한국자기학회지
    • /
    • 제2권2호
    • /
    • pp.150-155
    • /
    • 1992
  • 자장의 범위가 1 mT 이하이고, 분해능이 100 nT인 국가표준을 확립하고 저자장 측정장비의 교정 및 측정능력을 확보하기 위한 저자장 표준시스템을 제작하였다. 저장 발생용으로 석영관을 사용 한 정밀 솔레노이드를 가공.제작하였으며, 지자장 상쇄용으로 대형 3-축 헬름홀쯔 코일을 구성하였다. 자장 균일도를 향상시키기 위하여 단층 솔레노이드에서 주전류의 2개의 보조전류를 사용하는 three-current 방법을 사용하였으며, 컴퓨터를 사용하여 축상에서 최대의 균일도를 주는 조건을 계산하였다. Three-curent 방법을 사용한 경우 솔레노이드 중심축상에서 ${\pm}5\;cm$ 범위에서 0.01%, single current 일 때는 0.1%의 정밀도로 자장을 발생할 수 있었으며, 저자장 측정장비의 동특성을 측정할수 있는 시스 템을 구성하여 장비의 성능을 평가할 수 있었다.

  • PDF

Effect of Magnetic Field Annealing on Microstructure and Magnetic Properties of FeCuNbSiB Nanocrystalline Magnetic Core with High Inductance

  • Fan, Xingdu;Zhu, Fangliang;Wang, Qianqian;Jiang, Mufeng;Shen, Baolong
    • Applied Microscopy
    • /
    • 제47권1호
    • /
    • pp.29-35
    • /
    • 2017
  • Transverse magnetic field annealing (TFA) was carried out on $Fe_{73.5}Cu_1Nb_3Si_{15.5}B_7$ nano-crystalline magnetic core with the aim at decreasing coercivity ($H_c$) while keeping high inductance ($L_s$). The magnetic field generated by direct current (DC) was applied on the magnetic core during different selected annealing stages and it was proved that the nanocrystalline magnetic core achieved lowest $H_c$ when applying transverse field during the whole annealing process (TFA1). Although the microstructure and crystallization degree of the nanocrystalline magnetic core exhibited no obvious difference after TFA1 compared to no field annealing, the TFA1 sample showed a more uniform nanostructure with a smaller mean square deviation of grain size distribution. $H_c$ of the nanocrystalline magnetic core annealed under TFA1 decreased along with the increasing magnetic field. As a result, the certain size nanocrystalline magnetic core with low $H_c$ of 0.6 A/m, low core loss (W at 20 kHz) of 1.6 W/kg under flux density of 0.2 T and high $L_s$ of $13.8{\mu}H$ were obtained after TFA1 with the DC intensity of 140 A. The combination of high $L_s$ with excellent magnetic properties promised this nanocrystalline alloy an outstanding economical application in high frequency transformers.

Development of a Magnetic-field Stimulation System for Cell Cultures in situ: Simulation by Finite Element Analysis

  • Dominguez, G.;Arias, S.;Reyes, Jose L.;Rogeli, Pablo
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.326-332
    • /
    • 2017
  • The effects of exposure to an extremely low-frequency magnetic field (25 Hz 20G) on animal cells have been studied. In some reports, stimulation was performed for fixed frequency and variations in magnitude; however, animal-cell experiments have established that both parameters play an important role. The present work undertook the modeling, simulation, and development of a uniform-magnetic-field generation system with variable frequency and stimulation intensity (0-60 Hz, 1-25G) for experimentation with cell cultures in situ. The results showed a coefficient of variation less than 1 % of the magnetic-field dispersion at the working volume, which is consistent with the corresponding simulation results demonstrating a uniform magnetic field. On the other hand, long-term tests during the characterization process indicated that increments of only $0.4^{\circ}C$ in the working volume temperature will not be an interfering factor when experiments are carried out in in situ cell cultures.

탄소계 소재를 이용한 극저주파 영역에서의 자기 차폐효과 연구 (Study on the Magnetic Shield Effect of Carbon-based Materials at Extremely Low Frequency)

  • 오성문;강동수;이상민;백운경;노재승
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.15-20
    • /
    • 2015
  • To examine the magnetic shielding effect for carbon-based materials at extremely low frequencies (60 Hz), two types of carbon black (Super-P and Denka Black) and a natural graphite (HC-198) were mixed into organic binder at 10 wt.% to produce a coating solution, and a powder coating with varying thickness was applied on an aluminum disk measuring 88 mm in radius. A device was developed to measure the sheielding effect at extremely low frequencies. A closed circuit was achieved by connecting a transformer and a resistor. The applied voltage was fixed at 65 V, and the magnetic field was measured to being the range of 4.95~5.10 mG. Depending on the thickness of the coating layer, the magnetic field showed a decreasing trend. The maximum decrease in the magnetic field of 38.3% was measured when natural graphite was coated with specimens averaging $455{\mu}m$. This study confirmed that carbon-based materials enable magnetic shielding at extremely low frequencies, and that the magnetic shielding effect can be enhanced by varying the coating thickness.

자기센서용 Ni-PZT-Ni, Co, Fe 적층구조 소자의 ME 특성 (Magnetoelectric Characteristics on Layered Ni-PZT-Ni, Co, Fe Composites for Magnetic Field Sensor)

  • 류지구;전성즙
    • 한국전기전자재료학회논문지
    • /
    • 제28권2호
    • /
    • pp.92-98
    • /
    • 2015
  • The magnetoelectric characteristics on layered Ni-PZT-Ni, Co, Fe composites by epoxy bonding for magnetic field sensor were investigated in the low-frequency range. The ME coefficient of Ni-PZT-Ni, Ni-PZT-Co and Ni-PZT-Fe composites reaches a maximum of $200mV/cm{\cdot}Oe$ at $H_{dc}=110$ Oe, $106mV/cm{\cdot}Oe$ at $H_{dc}=90$ Oe and $87mV/cm{\cdot}Oe$ at $H_{dc}=160$ Oe, respectively. A trend of ME charateristics on Ni-PZT-Co, Ni-PZT-Fe composites was similar to that of Ni-PZT-Ni composites. The ME output voltage shows linearly proportional to ac field $H_{ac}$ and is about 0~150 mV at $H_{ac}$=0~7 Oe and f=110 Hz in the typical Ni-PZT-Ni sample. The frequency shift effect due to the load resistance $R_L$ shows that the frequency range for magnetic field sensor application can be modulated with appropriate load resistance $R_L$. This sample will allow for a low-magnetic ac field sensor in the low-frequency (near f=110 Hz).

초크랄스키법에 의한 8인치 실리콘 단결정 성장시 비대칭 커스프자장의 영향에 관한 연구 (A numerical study on the effects of the asymmetric cusp magnetic field in 8 inch silicon single crystal growth by Czochralski method)

  • 이승철;정형태;윤종규
    • 한국결정성장학회지
    • /
    • 제6권1호
    • /
    • pp.1-10
    • /
    • 1996
  • 초크랄스키법에 의한 8언치 실리콘 단결정 성장시 커스프자장의 영향에 관한 수치 해석적 연구를 행하였다. 액상실리콘의 유동에 대한 모렐은 저레이놀즈수 모렐을 사용하였다. 대칭커스프자장은 유션의 강도를 감쇄하였고, 특히 도가니 벽면 근처에서의 유동의 감쇄효과가 현저하였다. 결정으로 혼업되는 산소의 농도는 인가되는 커스프자장의 증가에 따라 감소하였다. 그리고, 결정으로 혼업되는 산소농도의 균일성은 향상되었다. 비대칭커스프 자장은 결정으로 혼 입되는 산소의 농도를 중가시켰지만, 반경방향의 산소농도의 분포는 일정하게 유지되었다. 대칭 과 비대청 커스프자장의 적절한 조합을 행하면 축방향으로 일정한 산소의 분포를 갖는 적절한 조업조건이 도출될 것으로 예상된다.

  • PDF

Comparative Study of Coupling Factors for Assessment of Low-Frequency Magnetic Field Exposure

  • Shim, Jae-Hoon;Choi, Min-Soo;Jung, Kyu-Jin;Kwon, Jong-Hwa;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.516-523
    • /
    • 2016
  • In this paper, coupling factors are calculated based on numerical analysis in order to assess various non-uniform low-frequency magnetic field exposure situations. Two types of non-uniform magnetic field sources are considered; circular coil and parallel wires with balanced currents. For each magnetic field source, source current values are determined so that reference magnetic field magnitude can be measured at the specified point on the human model. Various exposure situations are investigated by changing parameters such as the distance between source and human model, radius of circular coil, and the gap between parallel wires. For equivalent human models, prolate spheroid model and simplified human model from IEC 62311 standard are used. The calculated coupling factor values are compared with those obtained by 2D uniform disk human model, and the dependence of coupling factor on the choice of equivalent human model is analyzed.

극저주파 디지털 자계 측정기의 설계 및 구현 (Design and Implementation of ELF Digital Magnetic Fields Meter)

  • 임재유;황정환;김원호
    • 한국위성정보통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.84-88
    • /
    • 2015
  • 본 논문은 극저주파 자계 세기를 무선 모니터링하기 위한 디지털 자계측정기의 설계 및 구현에 대해 기술한다. 우리 실생활에 극 저주파대역의 자기장이 노출되어 있어 인체에 자기장이 얼마나 영향을 미치는가에 대한 연구의 필요성이 있으며 그에 따른 측정 장비의 수요가 증가하고 있다. 본 논문에서는 3-축 코일형 자계센서를 사용하였으며, 자계의 측정 범위는 0.03~10uT, 주파수 범위는 40~180Hz이다. 자계 세기의 측정과 주파수 특성을 보상하는 등화기능은 DSP 기반의 디지털 방식으로 설계하였으며, 측정 값은 와이파이 통신을 이용하여 PC 모니터링 할 수 있도록 설계 및 구현하였고 측정오차는 6% 이내로 실용성을 확인하였다.

Magnetic Wireless Actuator for Medical Applications

  • Kazushi, Ishiyama;Masahiko, Sendoh;Aya, Yanmazaki;Ken, Ichi Arai
    • Journal of Magnetics
    • /
    • 제8권1호
    • /
    • pp.74-78
    • /
    • 2003
  • The largest advantage of magnetic micromachine is wireless operation. This advantage makes it suitable for medical micromachine working inside the human body. In the medical field, low invasion treatment is very important From this point of view, very small machines working in the body without power supply cables meet the needs of the medical field. In this paper, we report about magnetic wireless actuators for medical applications.