• Title/Summary/Keyword: low loading

Search Result 1,572, Processing Time 0.028 seconds

Charge Depletion Effect on Collection Efficiency of an Electret Cabin Air Filter for Submicron Particles (승용차용 정전 필터 내의 정전 섬유의 보유 하전 감쇄에 의한 미세 입자 포집효율 변화)

  • Ji, Jun-Ho;Kang, Suk-Hoon;Hwang, Jung-Ho;Bae, Gwi-Nam
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.71-76
    • /
    • 2001
  • An electret filter is composed of permanently charged electet fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles are loaded. Long-term experiments were conducted by applying different charging states, which are spray electrification and charge equilibrium by bipolar ionization. In order to investigate on the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. In NaCl 0.1%, the collection efficiency of electret filter decreased and then did not change in equilibrium state. In the case of relative larger particles of NaCl 1%, collection efficiency for the equilibrium charged particles increases due to the particle loading on the filter fibers. Particles charged by spray electrification are small in collection efficiency after equilibrium state and increase of filter media's pressure drop was very low in comparison of the equilibrium charged particles.

  • PDF

Mobility Assessment of Equipment Foundation using Fluid-loaded Whole Ship Model (접수 전선 모델을 이용한 장비 받침대 모빌리티 평가)

  • Lee, Dong-Sup;Cho, Dae-Seung;Kim, Kookhyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.3
    • /
    • pp.179-183
    • /
    • 2014
  • The fluid loading effect has been investigated for the shipboard equipment foundation mobility with finite element model. For the purpose, two kinds of finite element models for 60m class ship have been developed: global and local model. The former is for low frequency range and the latter for middle frequency range. These finite element models contain added mass explaining fluid loading effect. Added mass has been implemented with virtual mass matrix derived from Laplace equation governing fluid surrounding ship hull. The mobility assessment result for diesel generator foundation of the objective model shows that the fluid loading effect should be considered, especially in low frequency range, to more accurately assess shipboard equipment foundation mobility.

Comparison of Traction Motor design and characteristics for battery driven hybrid tram (무가선 트램용 추진 전동기 설계 및 특성 비교)

  • Ham, Sang-Hwan;Kim, Kwang-Soo;Kim, Mi-Jung;Lee, Hyung-Woo;Lee, Ju
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1383-1388
    • /
    • 2010
  • The latest generation of tram is low-floor design, various nations in europe and japan have developed battery driven hybrid trams that combine battery and wiring. Battery driven tram system is achieved by contactless power supply system, thus system is needed high efficiency, high power and low weight traction motor for maximization of energy efficiency. Research from abroad is still in induction motor(IM) application, and it is not meet the efficiency and the power per unit volume in IPMSM. In this paper, we design compare IM and IPMSM to apply battery driven tram, and then compare these motors. To design the motor, we estimate the loading condition at first. Loading condition includes rolling resistance, air-drag resistance, and slope resistance. Based on the loading condition by estimation, we determine the power and compute rated voltage and rated current. In this paper, voltage is limited by battery voltage level. As a result, volume about IM is 1.98 times bigger than IPMSM under same condition. Even though IPMSM is bigger than IM in power density per volume, we consider more factors for actual application because there are demagnetization of permanent magnet in IPMSM and so on by external environment conditions.

  • PDF

Wind loading of a finite prism: aspect ratio, incidence and boundary layer thickness effects

  • Heng, Herman;Sumner, David
    • Wind and Structures
    • /
    • v.31 no.3
    • /
    • pp.255-267
    • /
    • 2020
  • A systematic set of low-speed wind tunnel experiments was performed at Re = 6.5×104 and 1.1×105 to study the mean wind loading experienced by surface-mounted finite-height square prisms for different aspect ratios, incidence angles, and boundary layer thicknesses. The aspect ratio of the prism was varied from AR = 1 to 11 in small increments and the incidence angle was changed from α = 0° to 45° in increments of 1°. Two different boundary layer thicknesses were used: a thin boundary layer with δ/D = 0.8 and a thick boundary layer with δ/D = 2.0-2.2. The mean drag and lift coefficients were strong functions of AR, α, and δ/D, while the Strouhal number was mostly influenced by α. The critical incidence angle, at which the prism experiences minimum drag, maximum lift, and highest vortex shedding frequency, increased with AR, converged to a value of αc = 18° ± 2° once AR was sufficiently high, and was relatively insensitive to changes in δ/D. A local maximum value of mean drag coefficient was identified for higher-AR prisms at low α. The overall behaviour of the force coefficients and Strouhal number with AR suggests the possibility of three flow regimes.

Impact Force and Acoustic Analysis on Composite Plates with In-plane Loading (면내하중을 받는 복합적층판에 대한 충격하중 및 음향 해석)

  • Kim, Sung-Joon;Hwang, In-Hee;Hong, Chang-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.2
    • /
    • pp.179-186
    • /
    • 2012
  • The potential hazards resulting from a low-velocity impact(bird-strike, tool drop, runway debris, etc.) on aircraft structures, such as engine nacelle or leading edges has been a long-term concern to the aircraft industry. Certification authorities require that exposed aircraft components must be tested to prove their capability to withstand low-velocity impact without suffering critical damage. In most of the past research studies unloaded specimens have been used for impact tests, however, in reality it is much more likely that a composite structure is exposed to a certain stress state when it is being impacted, which can have a significant effect on the impact performance. And the radiated impact sound induced by impact is analyzed for the damage detection evaluation. In this study, an investigation was undertaken to evaluate the effect in-plane loading on the impact force and sound of composite laminates numerically.

Transesterification of Jatropha Oil over Ceria-Impregnated ZSM-5 for the Production of Bio-Diesel

  • Bhagiyalakshmi, Margandan;Vinoba, Mari;Grace, Andrews Nirmala
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.3059-3064
    • /
    • 2013
  • In this study transesterification of Triglycerides (TG) from Jatropha curcas oil (JCO) with methanol for production of biodiesel was investigated over cerium impregnated ZSM-5 catalysts. NaZSM-5 was synthesized in an alkaline medium and impregnated with cerium oxide by wet method using cerium nitrate as a source for cerium. They were characterized by X-ray diffraction (XRD), Thermogravimeteric analysis (TGA), $CO_2$-temperature programmed desorption, and $N_2$ adsorption/desorption analysis. XRD analysis showed decrease in intensity of the patterns with the increase in the ceria loading but crystallization of ceria to larger size is an evident for 10 and 15% loading. The optimal yield of transesterification process was found to be 90% under the following conditions: oil to methanol molar ratio: 1:12; temperature: $60^{\circ}C$; time: 1 h; catalyst: 5 wt %. Here the yield of fatty acid methyl ester (FAME) was calculated through $^1H$ NMR analysis. The investigation on catalyst loading, temperature, time and reusability illustrated that these ceria impregnated NaZSM-5's were found to be selective, recyclable and could yield biodiesel at low temperature with low methanol to oil ratio due to the presence of both Lewis and Bronsted basicity. Hence, from the above study it is concluded that ceria impregnated ZSM-5 could be recognized as a potential catalysts for biodiesel production in industrial processes.

Mass Transfer and Hydraulic Kinematic Character Using Lattices Packings by Countercurrent Flow of Gas-Liquid Phase in Packing Column (격자형 충진물을 이용한 충진탑내 기액상의 역류에 의한 물질전달과 수력학적 동특성)

  • Kim, Jang-Ho;Ha, Sang-An
    • Journal of Ocean Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.130-137
    • /
    • 1988
  • This thesis introduced that character of a treatment technique for a mading synthetic resin Hifiow-Ring. The material system of packings make an experiment air$NH_{3}$/air$H_{2}SO_{4}$, $SO_{2}$-air/NaOH, $NH_{3}$-air/$/H_{2}SO_{4}$ under general conditions. Lattices packing compared with conventional packings was proved low pressure loss and high separation efficiency for high loading per trans unit. And an inflow materal tested for absorption and rectification, it made an experiment under a range regular temperature, low energy and small amount of money. That made possible in simple equation, volume material tranfer coefficient$\beta_{L}$ . a by absorption or $\beta_{V}$ .a calculated in all range loading. The peculiarity pressure loss $\Delta\;P/NUT_{ov}$ for Hiflow-ring contributed to a fall cost of energy, a grade number of a vacuum rectification and absorption calculation.

  • PDF

Analysis on the Flexural Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel (L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 휨 거동 분석)

  • Yu, Sung-Yong;Ju, Ho-Seong;Son, Guk-Won
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.52-62
    • /
    • 2015
  • This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.

Analysis of the Influence Factors of Data Loading Performance Using Apache Sqoop (아파치 스쿱을 사용한 하둡의 데이터 적재 성능 영향 요인 분석)

  • Chen, Liu;Ko, Junghyun;Yeo, Jeongmo
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.2
    • /
    • pp.77-82
    • /
    • 2015
  • Big Data technology has been attracted much attention in aspect of fast data processing. Research of practicing Big Data technology is also ongoing to process large-scale structured data much faster in Relatioinal Database(RDB). Although there are lots of studies about measuring analyzing performance, studies about structured data loading performance, prior step of analyzing, is very rare. Thus, in this study, structured data in RDB is tested the performance that loads distributed processing platform Hadoop using Apache sqoop. Also in order to analyze the influence factors of data loading, it is tested repeatedly with different options of data loading and compared with data loading performance among RDB based servers. Although data loading performance of Apache Sqoop in test environment was low, but in large-scale Hadoop cluster environment we can expect much better performance because of getting more hardware resources. It is expected to be based on study improving data loading performance and whole steps of performance analyzing structured data in Hadoop Platform.

Three dimensional finite element analysis of the fully bone anchored bridge and implant-supported overdenture in edentulous mandible (무치하악에서 임플랜트를 이용한 고정성 및 가철성 보철물의 삼차원 유한요소 분석)

  • Lim, Heon-Song;Cho, In-Ho;Lim, Ju-Hwan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.251-276
    • /
    • 2002
  • The purpose of this study was to compare and analyze the stress distribution and displacement of the fully bone anchored bridge and implant-supported overdenture in edentulous mandible on certain conditions such as number of implants, different design of superstructure. Three dimensional analysis was used and nine kinds of models designed for this study. FEM models were created using commercial software[$Rhinoceros^{(R)}$ (Ver. 1.0 Robert McNeel & Associates, USA)], and analyze using commercial software [Cosmos/$Works^{TM}$(Ver. 4.0 Structural Research & Analysis Corp., US A)]. A vertical load and $45^{\circ}$ oblique load of 17kgf were applied at the left 1st. molar. The results were as follows : (1) In the group of OVD, the displacement was reduced as increasing the number of fixture under vertical loading but there was no specific difference in Von Mises stress. Under oblique loading, the displacement was same at the vertical loading but Von Mises stress was reduced in order of OVD-3, OVD-4, OVD-2. But, bending moment reduced according to increasing the number of fixture. (2) In the group of FBAB, under vertical and oblique loading, the magnitude of Von Mises stress and displacement reduced according to increasing the number of fixtures. FBAB-4 and FBAB-5 showed similar score and distribution, but FBAB-6 showed lower value relatively. (3) In cantilever design, the maximum displacement reduced under vertical loading but increased under oblique loading. However, von mises stresses on fixtures increased under vertical and oblique loading. (4) In comparing OVD-group with FBAB-group, FBAB showed low magnitude of displacement in respect of oblique loading. However OVD-group was more stable in respect of stress distribution.