• Title/Summary/Keyword: low level measurement

Search Result 720, Processing Time 0.028 seconds

Calibration Techniques for Low-Level Current Measurement in the Characteristic Analysis System for Semiconductor Devices (저전류 측정을 위한 반도체 소자 특성 분석 시스템에서의 보상 기법)

  • Choi, In-Kyu;Park, Jong-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.111-117
    • /
    • 2002
  • In this paper, we proposed calibration techniques to improve measurement accuracy in the characteristic analysis system for semiconductor devices. Systematic errors can be reduced using proposed calibration techniques. Also, error current reduction procedures including leakage current and offset current are proposed to measure low-level current in pA level. Calibration parameters are calculated and stored by microprocessor using least-square fitting with measured sample data. During measurement time microprocessor corrects measured data using stored calibration parameters. Experimental results show that current measurement error above nA level is less than 0.02%. And they also show that current measurement in pA level can be performed with about 0.2% accuracy.

Development of Automatic Water Level Measurement System for the Irrigation Reservoir - Study on Low Power and Remote Controlled Water Level Measurement System - (농업저수지 자동 수위관측기 개발 - 저전력 원격제어 수위관측기 중심 -)

  • Kim, Jin-Taek;Joo, Uk-Jong;Choi, Seung-Chul
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.491-494
    • /
    • 2003
  • An Automatic Water Level Measurement System has been developed in this study. It has the characteristics that it use lower power and solar power and it has the ability of sending data and remote-controlled by wireless MODEM this system was set up in the experimental site and was tested. Also, the management system for the water level data has been developed and will be used by instruments administrating reservoirs.

  • PDF

Uncooled Microbolometer FPA Sensor with Wafer-Level Vacuum Packaging (웨이퍼 레벨 진공 패키징 비냉각형 마이크로볼로미터 열화상 센서 개발)

  • Ahn, Misook;Han, Yong-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.300-305
    • /
    • 2018
  • The uncooled microbolometer thermal sensor for low cost and mass volume was designed to target the new infrared market that includes smart device, automotive, energy management, and so on. The microbolometer sensor features 80x60 pixels low-resolution format and enables the use of wafer-level vacuum packaging (WLVP) technology. Read-out IC (ROIC) implements infrared signal detection and offset correction for fixed pattern noise (FPN) using an internal digital to analog convertor (DAC) value control function. A reliable WLVP thermal sensor was obtained with the design of lid wafer, the formation of Au80%wtSn20% eutectic solder, outgassing control and wafer to wafer bonding condition. The measurement of thermal conductance enables us to inspect the internal atmosphere condition of WLVP microbolometer sensor. The difference between the measurement value and design one is $3.6{\times}10-9$ [W/K] which indicates that thermal loss is mainly on account of floating legs. The mean time to failure (MTTF) of a WLVP thermal sensor is estimated to be about 10.2 years with a confidence level of 95 %. Reliability tests such as high temperature/low temperature, bump, vibration, etc. were also conducted. Devices were found to work properly after accelerated stress tests. A thermal camera with visible camera was developed. The thermal camera is available for non-contact temperature measurement providing an image that merged the thermal image and the visible image.

Measurement of low level sound noise using cross spectrum method (크로스 스펙트럼 기법을 이용한 저레벨 소음의 측정)

  • 박창규;강경일
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.2
    • /
    • pp.241-248
    • /
    • 1998
  • The accurate measurement of the room sound level is required in environment noise control. However, it has been found that the measurement system noise always corrupts the actual noise from the sound source. In this study, a new sound level measurement technique in which the system noise is eliminated from the measured signal by the cross spectrum method, is proposed. The received signals of two measuring microphones are recorded to DAT through the pre-amplifier and digitized by A/D converter. The cross spectrum calculated from the digitized signals gives the accurate sound level since the system noise is uncorrelated with the sound source noise which we want to measure. The performance of the proposed technique is verified experimentally to be effective and the technique is found to be economic since the low cost general purpose microphone could be used in this technique.

  • PDF

The research of the UWB system radiation measurement (UWB 시스템의 방사출력 측정방법 연구)

  • Song, Hong-Jong;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.277-286
    • /
    • 2010
  • In this paper we analyse radiation measurement method for UWB wireless system of the wideband low power frequency characteristics. In the radiation measurement environment we discuss RMS electric field strength, UWB PSD, UWB detect signal level, UWB noise signal collection etc.. also, we discuss power measure method of the CISPR16-1, low level e.i.r.p radiation measurement method. lastly we analyse consideration problem for the signal analyser of the UWB system.

A Measurement and Analysis of Low Level Radiated-Noise Using Vertical Line Array (수직선배열을 이용한 저소음 함정음향 측정 및 분석기법)

  • Choi, Jae-Yong;Son, Kweon;Dho, Kyeong-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.55-64
    • /
    • 2003
  • Underwater acoustic noise measurement is an essential element for vulnerability assessment of modern naval platforms. But during the last few decades environmental conditions have drastically changed due to the gradually increasing sea ambient noise level and decreasing submarine radiated noise level. A real-time underwater acoustic measurement system with vertical line array is designed for the quiet submarine radiated noise assessment in challenging environment. This system has a constant directivity index in measurement frequency range and accurate tracking capability for the transmission loss compensation and navigation aids inside the submarine. This system has been validated at sea and used several times for the submarine noise measurement.

A Study on the Measurement of Small Partial Discharges in a Low-voltage Induction Motor (저압 유도전동기에서 미소 부분방전 측정에 관한 연구)

  • Kil, Gyung-Suk;Song, Jae-Yong;Seo, Hwang-Dong;Hwang, Don-Ha;Kang, Dong-Sik;Kim, Yong-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.10
    • /
    • pp.960-964
    • /
    • 2005
  • In this paper, we dealt with a partial discharge(PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage electric and electronic devices. The PD measurement system Is composed of a coupling network, a low noise amplifier, and associated electronics. h shielded box Is adopted to make a better measurement environment against around noise. A low cut-off frequency of the coupling network estimated by a sinusoidal wave input was 125 kHz (-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 10 mV/pC. In an application test oil a low-voltage three phase Induction motor (5 HP), we could detect 0.53 pC level of partial discharge at the applied voltage of AC 650 $V_{peak}$.

Design and Fabrication of an Ultra-low Partial Discharge Measurement System (극미소 부분방전 측정시스템의 설계 및 제작)

  • Seo, Hwang-Dong;Song, Jae-Yong;Moon, Seung-Bo;Kil, Gyung-Suk;Kwon, Jang-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.208-211
    • /
    • 2005
  • This paper presents an ultra-low partial discharge(PD) measurement system that has been accepted as a non-destructive method to estimate electrical insulation of low-voltage electric devices. The PD measurement system is composed of a coupling network, a low noise amplifier, and associated electronics. A shielding box is used to make a better condition against electromagnetic interference. A low cut-off frequency of the coupling network was 1MHz(-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 11.4mV/pC. In an application experiment on a low-voltage induction motor(5HP), we could detect 0.77pC level of partial discharge pulse at the applied voltage of AC 664 V$_{peak}$.

  • PDF

Cause Analysis of Level Measurement Error in Steam Generator of Nuclear Power Plant (원자력발전소의 증기발생기 수위계측 오차 원인분석)

  • Lee, Kwang-Dae;Oh, Eung-Se;Yang, Seung-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.591-593
    • /
    • 2006
  • The differential pressure method has been used in the level measurement of steam generator in nuclear power plant. Two sensing lines from a steam generator to a pressure transmitter are needed to measure the high pressure and low pressure. The fluid conditions in the sensing line require the uniform phase with no bubbles and the slope of sensing line should be installed with forward slope. The expansion of the bubble volume according to the upper pressure and the reverse slope of sensing lines explain how the level errors took place.

  • PDF

An Experimental Study to Improve Measurement Reliability for the Airborne Sound Insulation Performance by Laboratory Test (실험실 실험을 통한 벽체 차음성능 측정의 신뢰성 향상을 위한 실험적 연구)

  • Kim, Hang;Park, Hyeon Ku;Ku, Hee Mo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.1
    • /
    • pp.35-44
    • /
    • 2014
  • Sound pressure levels in the receiving room while testing airborne sound insulation performance are varied by the measuring points. This may increase the measurement error, then decrease the measurement reliability. With this reason the research has carried out on the method to reduce deviations of sound pressure level in the ISO type rectangular laboratory focusing on the measurement of airborne sound insulation performance. Tests were made to see the effect of sound absorption in the receiving room, loudspeaker locations, microphones locations and flanking transmission path. Consequently, it was resulted that sound absorption in the receiving room and the loudspeaker location have influence on the sound level deviations especially in the low frequency. The microphone location was very important to get measurement reliability. The effective measuring point, which the sound level difference with average sound pressure level is within 2 dB, could yield most reliable average sound pressure level. Therefore it is necessary to find the effective measuring points in the receiving room. Flanking transmission path should be sealed using sound absorber or magnet etc. to prevent from lowering the sound insulation performance.