• 제목/요약/키워드: low intensity laser

검색결과 115건 처리시간 0.03초

흰 쥐의 선상 절개 창상모델에서 저출력 레이저 자극이 조직 염증반응에 미치는 영향 (The Effects of Low Power Laser Treatment on Tissue Inflammatory Reactions in the Linear Incision Wound on Rat Skin)

  • 임인혁;이정원;김현숙
    • 한국전문물리치료학회지
    • /
    • 제10권2호
    • /
    • pp.61-70
    • /
    • 2003
  • The purposes of this study was to evaluate the effect of low power GaAsAl laser on tissue contraction in a linear incision wound on rat skin. The linear incision wound was made on the midline of the backside in the experimental animals. Low power laser applications with different intensities such as 3, 6, or 10 mW were applied to the experimental animals twice a day for 10 days. On either the seventh or tenth postoperative day, the quantitative analysis of the inflammatory reaction surrounding the linear incision wounds on the rats were performed using enzymatical analysis of myeloperoxidase (MPO) activity. The number of neutrophil was $.07-1.0{\times}106/m{\ell}$ from a normal blood sample that was obtained from the normal experimental animals. Each concentration of neutrophil showed .04-.62 unit activity of MPO. Therefore, the 6 unit activity of MPO per neutrophil was $.57{\pm}.014{\times}10^{-6}$ unit. On the 7th and 10th post operative day, non treated tissues demonstrated increased MPO activity as compared to that of normal tissue. These data indicated that the inflammatory reaction of tissue was induced after wound induction and the MPO activity were increased in the inflammed tissues. While both 3 mW or 6 mW intensity of laser treatments did not affect the tissue MPO activity, 10 mW intensity of laser treatment significantly decreased the tissue MPO activity on the 7th and 10th post operative day. These data demonstrated that only 10 mW intensity of laser treatment successfully suppressed tissue inflammatory reaction after wound induction. In conclusion, these findings suggested that 10 mW of GaAIAs laser treatments effectively suppressed the inflammatory reaction of tissue that was induced during the wound healing process.

  • PDF

The efficacy of low-level diode laser versus laser acupuncture for the treatment of myofascial pain dysfunction syndrome (MPDS)

  • Khalighi, Hamid Reza;Mortazavi, Hamed;Mojahedi, Seyed Masoud;Azari-Marhabi, Saranaz;Parvaie, Parvin;Anbari, Fahimeh
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권1호
    • /
    • pp.19-27
    • /
    • 2022
  • Background: Myofascial pain dysfunction syndrome (MPDS) is the most common type of temporomandibular disorder. This study compared the efficacies of low-level diode laser therapy (LLLT) and laser acupuncture therapy (LAT) in the treatment of MPDS. Methods: This double-blind randomized controlled clinical trial included 24 patients with MPDS who were randomly divided into two equally sized groups. Patients in the LLLT group received 12 sessions of low-level diode laser irradiation applied to the trigger points of the masticatory muscles during 1 month. The same protocol was also used in the LAT group according to the specific trigger points. We measured pain intensity and maximum mouth opening in both groups at baseline, during treatment, and 2 months after treatment completion. Results: The pain intensities decreased from 6.58±1.31 to 0.33±0.65 and from 7.08 ± 1.37 to 0 in the LLLT and LAT groups, respectively. The maximum mouth openings increased from 32.25 ± 8.78 mm to 42.58 ± 4.75 mm and from 33 ± 6.57 mm to 45.67 ± 3.86 mm in the LLLT and LAT groups, respectively. Pain intensity (P = 0.839) and level of maximum mouth opening (P = 0.790) did not differ significantly between the groups. Conclusion: Our results showed similar efficacy between LLLT and LAT in the treatment of MPDS signs and symptoms.

Low-Level Laser Therapy including Laser Acupuncture for Non-Specific Chronic Low Back Pain : Protocol for a Systematic Review

  • Yeum, Hyewon;Nam, Dongwoo
    • Journal of Acupuncture Research
    • /
    • 제36권4호
    • /
    • pp.251-255
    • /
    • 2019
  • Background: Low-level laser therapy (LLLT) including laser acupuncture (LA) has been widely used to treat chronic low back pain (CLBP), but there is no critically appraised evidence of the potential benefits. The purpose of this protocol for a systematic review was to enable the evaluation of the effectiveness of LLLT including LA for non-specific CLBP to identify the potential benefits. Methods: The electronic databases MEDLINE (PubMed), Embase (Ovid), the Cochrane Central Register of Controlled Trials (CENTRAL), Korean medical databases (KoreaMed, KMBASE, KISS, NDSL, KISTI, OASIS), the Chinese database (CNKI), and Japanese databases (CiNII, J-STAGE) are recommended. Results: Randomized controlled trials in LLLT including LA should be included in the searches. All data synthesis and subgroup analyses should be conducted using a Review Manager software. The Cochrane risk of bias tool can be used to evaluate methodological quality of the studies. A risk ratio or mean difference with a 95% confidence interval will show the effects of LLLT including LA. Conclusion: The primary outcome would be pain intensity and functional status/disability due to low back pain. The secondary outcome would be a global measurement of recovery or improvement, quality of life and adverse event.

External Feedback Effects on the Relative Intensity Noise Characteristics of InAIGaN Blue Laser Diodes

  • Cho Hyung-Uk;Yi Jong-Chang
    • Journal of the Optical Society of Korea
    • /
    • 제10권2호
    • /
    • pp.86-90
    • /
    • 2006
  • The external feedback effect on the relative intensity noise (RIN) characteristics of blue InAlGaN laser diode has been analyzed taking into account the spontaneous emission noise and the injection current for the high frequency modulation. A Langevin diffusion model was exploited to characterize its relative intensity noise. The simulation parameters were quantitatively evaluated from the optical gain properties of the InAlGaN multiple quantum well active regions by using the multiband Hamiltonian for the strained wurtzite crystals. The extracted parameters were then applied to the rate equations taking into account the external feedback and the high frequency modulation current. The RIN characteristics were investigated to optimize the low frequency laser diode noise characteristics.

홀로그래픽 정보저장장치에서 디지털 이미지 마스크를 이용한 실시간 광량 제어 알고리즘 (Real Time Light Intensity Control Algorithm Using Digital Image Mask for the Holographic Data Storage System)

  • 김상훈;양현석;박영필
    • 정보저장시스템학회논문집
    • /
    • 제6권1호
    • /
    • pp.1-5
    • /
    • 2010
  • Holographic data storage system(HDSS) has many noise sources - crosstalk, scattering and inter pixel interference, etc. Generally the intensity of a light generated from the laser source has Gaussian distribution and this ununiformity of light also can make the data page to have a low SNR. A beam apodizer is used to make the laser as a flat-top beam but the intensity distribution is not strictly uniform. The intensity of light can be controlled using image mask. In this paper the intensity distribution of light used for HDSS is controlled by a digital image mask. The digital image mask is changed arbitrarily in real-time with suggested algorithm for the HDSS.

Comparative Analysis of Photoplethysmography under Pulsed Magnetic Field and Low Level Laser Stimulus: Motivation for Blood Flow Increase using Stimulus on Acupoint LI4 (Hegu)

  • Kim, Young Jin;Yoo, Jun Sang;Hwang, Do Guwn;Lee, Hyun Sook
    • Journal of Magnetics
    • /
    • 제19권1호
    • /
    • pp.32-36
    • /
    • 2014
  • The purpose of this study was to investigate the effect of pulsed magnetic field (PMF) and low frequency low level laser (LFLLL) stimuli on acupoint LI4 (Hegu) using photoplethysmography (PPG). Our PMF system was designed to generate maximum intensity of 0.20 T at a transition time of 0.16 ms, with pulse intervals of 1 Hz. The diode laser with wavelength of 650 nm and power of 5 mW was also employed. It was observed the change of the pulsating blood volume through measuring PPG signals from both hands. These results imply that stimulating acupoint LI4 with PMF and LFLLL improves the circulation of peripheral vascular system. In particular, PMF stimulation brings a big improvement of the blood flow even with short term stimulation of 3-4 minutes compared to LFLLL stimulus.

다발성 관절염 실험동물 모델에서 저출력 GaAsAl 레이저 자극에 의한 소염효과 (The anti-inflammatory effect of low power GaAsAl laser stimulation on the polyarthritis of rats)

  • 장문경;심규리;최영덕
    • 대한물리치료과학회지
    • /
    • 제9권2호
    • /
    • pp.99-109
    • /
    • 2002
  • We designed the experiments to elucidate the anti-inflammatory effect of low power laser stimulation on acupoint or non-acupoint using arthrogenic solution induced poly arthritis animal model. In order to achieve the experimental purpose, change in body weight paw edema, pathological changes in inflammed pint and the serum interlukin-6 level were measured after arthritis induction in acupoint later stimulated group, non acupoint laser stimulated group and non treated control animal. The results were summerized as follows: 1. The consistent increase in body weight was observed in the normal animal during whole experimental period, while the induction of arthritis significantly suppressed increase in body weight from the 15 day after arthritis induction. Especially, non treated animal group showed more suppressive effect on increase in body weight as compared to that of low power laser stimulated groups (P<0.05). 2. Low power laser stimulation on acupoint (Zusanli) significantly inhibited edema in the left side paw from the 12th day after arthritis induction as compared to that of non treated animals. This suppressive effect on paw edema was maintained until the end of experiment. 3. Laser treatment on acupoint dramatically suppressed the radiological change (i.e. new bone proliferation and soft tissue swelling) caused by arthritis as compared to that of non treated group animals. 4. Low power laser treatment reduced the increase in serum interlukin-6 caused by arthritis induction to levels observed in the normal animals. In conclusion, the results of the present study demonstrated that low power laser stimulation on acupoint has potent anti-inflammatory effect on arthritis. Thus it is recommended that low power laser be used for long term treatment of arthritis induced inflammation. However, further study is necessary to clarify the possible side effect of laser treatment depending upon intensity and duration of stimulation.

  • PDF

열적외선 기기와 3차원 레이저 스캐너를 이용한 암석 표면의 풍화강도 분석 (Analysis The Intensity of Weathering of The Rock Surface Using 3D Terrestrial Laser Scanner and Thermal Infrared Instrument)

  • 이수곤;조항교;쉬징
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1324-1333
    • /
    • 2010
  • This paper is used in a recent civil engineering field in three-dimensional laser-meter tiles using thermal imaging cameras for the weathered rock slopes precisely measured indirectly, to the degree that began in the will. In the field is difficult to access the degree of weathering of the rock slope to the existing direct way to compensate for the shortcomings of 3D Terrestrial Laser Scanner and weathering characteristics of rocks using thermal imaging cameras to get the information to analyze the degree of rock weathering is. Intensity of 3D TLS and the thermal camera with image analysis to analyze the degree of weathering of bedrock in the field of core drilling targeting indoor laboratory tests were analyzed through the study. Granite, gneiss, sandstone, much of the cancerous samples, each experiment has a 40 per category, each of which 30 were used to analyze the data collected. That degree of rock weathering, the rock, depending on the strength of the Intensity values can change, depending on the level of thermal imaging camera, also weathered the changes in temperature could see. Intensity is the strength of weak rocks, the more value decrease, the temperature of the thermal imaging camera through the swell Intensity and notice that the temperature had an inverse relationship. Intensity value of the low strength of weak rock, but the value came out of the rocks have been proved to be largely dependent on the contrast. The contrast of the surface rocks are weathered dark Intensity values lower temperature to swell the contrary, the degree of weathering can be distinguished.

  • PDF

펨토초 레이저에 의한 투명 유리내부 미세가공특성 (Micromachining Characteristics inside Transparent Materials using Femtoseocond Laser Pulses)

  • 남기곤;조성학;장원석;나석주;황경현;김재구
    • 한국정밀공학회지
    • /
    • 제23권5호
    • /
    • pp.190-196
    • /
    • 2006
  • Transparent materials are widely used in the fields of optic parts and bio industry. We have experiment to find out the characteristics of the micromachining inside transparent materials using femtosecond laser pulses. With its non-linear effects by very high peak intensity, filament (plasma channel) was formed by the cause of the self-focusing and the self-defocusing. Physical damage could be found when the intensity is high enough to give rise to the thermal stress or evaporation. At the vicinity of the power which makes the visible damage or modification, the structural modification occurs with the slow scanning speed. According to the polarization direction to the scanning direction, the filament quality is quite different. There is a good quality when the polarization direction is parallel to the scanning direction. For fine filament, we could suggest the conditions of the high numerical aperture lens, the short shift of focusing point, the low scanning speed and the low power below 20 mW. As the examples of optics parts, we fabricated the fresnel zone plate with the $225{\mu}m$ diameter and Y-bend optical wave guide with the $5{\mu}m$ width.

$Cr^{4+}$:YAG 포화 흡수체를 이용한 레이저 다이오드 뒷면 여기 Nd:YAG 레이저의 들뜸 효율 및 Q-switching 특성 연구 (Measurement of excitation efficiency and passively Q-switched characteristics of laser diode end-pumped Nd:YAG laser by using $Cr^{4+}$:YAG as a saturable absorber)

  • 정태문;김광석;문희종;이종훈;김철중;이종민
    • 한국광학회지
    • /
    • 제9권4호
    • /
    • pp.231-235
    • /
    • 1998
  • 레이저 다이오드 뒷면 여기 방식을 이용한 Nd: YAG 레이저를 제작하고, 뒷면 여기 방식을 이용하였을 때, 들뜸 효율을 측정하였다. 포화 흡수체로 $Cr^{4+}$:YAG를 레이저 공진기 내부에 설치하여 수동형 Q-switching을 수행하였고, 그 때, 평균 출력, 펄스폭 및 반복율 특성등을 조사하였다. 수동형 Q-switching된 레이저의 펄스폭 및 반복율은 평균 출력 및 $Cr^{4+}$:YAG 결정의 낮은 강도 투과율(low intensity trasmission)에 따라 변화하였으며, 평균 출력은 최고 1 W, 펄스폭은 최저 51 nsec 까지 얻을 수 있었고 최고 약 40kHz의 고반복율로 동작하는 것을 관찰하였다.

  • PDF