• Title/Summary/Keyword: low impact development (LID)

Search Result 209, Processing Time 0.032 seconds

A study on calculation of permeable area ratio in impervious basin using K-LIDM model (K-LIDM 모형을 이용한 불투수유역 내 투수면적비 산정에 관한 연구)

  • Park, Jaerock;Kim, Jaemoon;Baek, Jongseok;Seo, Youngjae;Shin, Hyunsuk
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.11
    • /
    • pp.969-977
    • /
    • 2022
  • In order to respond to the increase in water disasters due to climate change and urbanization, research on low impact development (LID) techniques and application to cities are expanding. The LID technique is a technology that reduces rainwater runoff in the city, controls various water disasters such as flash floods, etc. in an eco-friendly way, and restores the urban water circulation system to a natural water circulation system. However, quantitative analysis of stormwater runoff reduction through the LID technique is insufficient. Therefore, this study analyzed the ratio of the permeable area required to reduce the surface runoff of rainfall (25 mm/hr, 50 mm/hr, 100 mm/hr) with respect to the impervious watershed area of the old city using the permeable pavement. As a result of the analysis, it was found that a permeable area ratio of 7.14 to 12.63% of the total area was required for 25 mm/hr, 15.79 to 26.97% for 50 mm/hr, and 30 to 55.81% for 100 mm/hr.

Improvement of the Design Process of LID Retrofit Testbed for Effect Analysis of the Water Cycle (LID Retrofit 시범단지 설계 절차 개선)

  • Jung, Jong-Suk;Lim, Jung-Min;Hyun, Kyoung-Hak
    • Land and Housing Review
    • /
    • v.8 no.4
    • /
    • pp.267-274
    • /
    • 2017
  • Since LID design process for the urban regeneration has not yet been established in Korea, this study was extablished in LID design process through reterauture reviews and expert opinions. But the extablished LID design processes have many limitations to be applied to proper LID facilities to the site because of not considering characteristics and water flow of the site. To solve the limitations of existing design processes, it is necessary for analysis of water flow through GIS analysis at the site. After analysis of water flow, it is important to find areas cut off water flow and to install LID facilities at those points. Through these considerations, this study present the improved LID design process to apply to urban regeneration.

Development of Infiltration System for Stormwater Management from Paved Area (포장지역 강우유출수 관리를 위한 침투도랑 기술개발)

  • Lee, Jeong-Yong;Maniquiz, Marla C.;Lee, So-Young;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.12 no.3
    • /
    • pp.165-175
    • /
    • 2010
  • Recently, various development projects have occurred due to rapid industrialization and urbanization. Both industry and population grew rapidly which causes a corresponding rise in pollution. The accumulated pollutants are washed-off during rainy days, highly degrading the water quality of the receiving water body. This is because a lot of non point source (NPS) pollutants were accumulated on the surface during dry periods. This research focuses on the development of Eco-Bio Filter (EBF) system that treats NPS pollutants. It is constructed at Kongju National University campus. The EBF is a type of a structured infiltration system that falls under the category of Low Impact Development (LID) hydrologic design practices. The monitoring of rain events was performed. It includes the development of design, the lessons learned from the post-construction testing and the improvements in the renovation made. After a series of monitoring, the MOE will use the results to apply the design to other areas in the country.

Cost-Benefit Analysis for LID Installation in Flood Damage Basin (홍수 피해 유역의 LID 설치에 따른 비용 편익 분석)

  • Baek, Jong Seok;Kim, Baek Joong;Kim, Hyeong San;Lee, Sang Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.253-253
    • /
    • 2016
  • 여러 정부부처 및 지자체에서 도시지역 홍수 피해 및 비점오염원 저감 방안의 해법으로 LID 시설의 설치를 권장하고 있다. 하지만 LID 기술의 국내 도입 기간이 짧아 우리나라 환경에 맞는 LID 시공을 할 수 있는 업체가 한정적이고 시공경험도 많지 않아 시공 비용에 대한 경제성 분석이 어렵다. 이러한 문제점으로 인해 LID 설치 비용의 과대 인식과 실효성에 대한 불안감이 만연하여 시설 설치에 어려움을 겪고 있다. 이와 관련하여 GI&LID 연구단에서 LID 통합설계모듈 등의 모형 개발 연구가 활발히 진행중이나 이에 앞서 금번 연구에서는 SWMM 모형을 이용하여 분석을 수행하였고, 가시적인 비교가 용이하고 최근 가장 큰 피해를 가져왔던 2014년 홍수 사상을 대상으로 연구를 진행하였다. 본 연구에서는 도시내 급경사면이 많고 불투수면적율이 높아 유속이 빠르고 완경사로 변화되는 구간에 홍수 및 토석류가 집중되어 홍수피해에 취약한 부산시 온천천 유역을 대상으로 LID 시설을 모의 설치 및 시뮬레이션 하고 재해연보 상의 홍수피해 복구액과 비교하였다. 이를 통해 LID 시설 설치시 비용-편익을 분석하고 이점을 제시하여 추후 있을 LID 시공 및 관련 연구에 도움이 되고자 한다.

  • PDF

Performance Evaluation of Water Circulation Facilities with Infiltration and Retention Functions (침투 및 저류 기능을 가진 물 순환 시설의 효과 평가)

  • Hong, Jung Sun;Maniquiz-Redillas, Marla C.;Kim, Ree Ho;Lee, Seon Ha;Kim, Lee-Hyung
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.4
    • /
    • pp.305-310
    • /
    • 2015
  • In 2014, the city of Seoul revised the ordinance regarding water-cycle restoration in the Seoul Metropolitan areas by incorporating the 'Low Impact Development (LID)' policy. The new ordinance plan will utilize 630 mm or almost 45 to 50% of annual rainfall until 2050 by means of providing a rainwater management system consisting of infiltration, retention and vegetation. The LID is believed to be the key to achieving the target requirements, specifically in development projects. This research was performed to evaluate the stormwater runoff and pollutant reduction performance of three different LID facilities (water circulation facilities) including an infiltration inlet, bioretention swale, and permeable pavement constructed in Seoul City. Results show that among the water circulation facilities, the permeable pavement achieved the highest runoff reduction as it was able to entirely capture and infiltrate the runoff to the ground. However, in order to attain a long-term performance it is necessary to manage the accumulated sediment and trapped pollutants in the landscape areas through other water circulation techniques such as through soil erosion control. In terms of pollutant reduction capability, the infiltration inlet performed well since it was applied in highly polluted areas. The bioretention facility integrating the physico-chemical and biological mechanisms of soil, microorganisms and plants were able to also achieve a high runoff and pollutant reduction. The water circulation facilities provided not only benefits for water circulation but also various other benefits such as pollutant reduction, ecological restoration, and aesthetic functions.

Comparison of Flooding Tolerance for the Selection of Plants in Vegetation-Based Low Impact Development Facilities (식생기반형 LID 시설의 식재식물 선정을 위한 내침수성 비교)

  • Lee, Eun-Yeob;Hyun, Kyoung-Hak;Hou, Jin-Sung;Park, Mi-Ok;Koo, Bon-Hak
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.6
    • /
    • pp.466-476
    • /
    • 2014
  • In this study, 10 species of plants with high adaptability to aquatic environments were compared for selecting plant species suitable for vegetation-based low impact development (LID) facilities. The flooding tolerances of the plants were tested by analyzing their growth status under half-immersion and full-immersion conditions, with varying durations of immersion. In decreasing order of flooding tolerance, the comparative analysis of plant height and leaf width is as follows: Hemerocallis fulva, Juncus effusus var. decipiens, Iris pseudoacorus, Phragmites communis TRIN, Typha orientalis C.Presl, Aster koraiensis Nakai, Iris sanguinea, Equisetum hyemale, Acorus calamus. Specifically, Hemerocallis fulva, Juncus effusus var. decipiens. Iris pseudoacorus showed excellent growth status under both immersion conditions. Iris sanguinea and Equisetum hyemale. withered to death by around day 27 of the experiment, but their flooding tolerance was confirmed to be relatively high. Iris pseudoacoru showed flooding tolerance under the half-immersion condition unlike under the full-immersion condition, when compared on day 21 of the experiment. Aster koraiensis Nakai also thrived better under the half-immersion condition, proving to be a highly immersion-resistant species. On the basis of the results of this experiment, Hemerocallis fulva, Juncus effusus var. decipiens and Iris pseudoacorus, Typha orientalis C.Presl were selected as species suitable for vegetation-based LID facilities.

The Analysis of Runoff Characteristics by Alterations of SCS-CN Value using LID Method (LID 기법 적용에 의한 SCS-CN값 변화가 강우유출특성에 미치는 영향 분석)

  • Kwon, Jun-Hee;Park, In-Hyeok;Ha, Sung-Ryoung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.1
    • /
    • pp.49-57
    • /
    • 2010
  • The objective of the research is to analyze changing trend of water discharge in precipitation, according to changing land use, through an environment-friendly urban development method called LID. The study chose S1 basin (Separated Sewer districts) in Cheongju region for survey. Among LID methods, relatively more applicable methods of green rooftop space and parking lot with permeable material were selected to construct plausible scenarios. Curve Number (CN) value was calculated due to land use patterns in each scenario, and SWMM model simulation were conducted during 2008 for comparative analysis. For Case 1, only parking lot with permeable material was applied to the scenario. Green rooftop space I and II were applied to Case 2 and 3 respectively. For Case 4 and 5, green rooftop space I and II were applied, in addition to parking lot with permeable material, Calculation of CN value showed that for S1 basin, the value was 88.1 (prior to scenario application), 86.5 (Case 1), 81.9 (Case 2), 68.5 (Case 3), 80.4 (Case 4) and 67.2 (Case 5). Changing pattern of rain water discharge was analyzed for each scenario. For Case 1, the change was not remarkable before and after application of scenario. In Case 2 and 4, the impact of rain water discharge as source of pollutant fell to 20~30%. The rate dropped to 30~50% in Case 3 and 5 respectively. The result demonstrates that the amount of rain water discharge, amount and frequency of sewer overflow, frequency of rain water discharge, and pollution load decreased in accordance with declining CN value in each scenario. In installing green rooftop space, the effect was twice greater when rain water discharge was directly infiltrated into soil.

Analysis on the Water Circulation and Water Quality Improvement Effect of Low Impact Development Techniques by Test-Bed Monitoring (시범 단지 운영을 통한 LID 기법별 물순환 및 수질개선 효과 분석)

  • Ko, Hyugbae;Choi, Hanna;Lee, Yunkyu;Lee, Chaeyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.5
    • /
    • pp.27-36
    • /
    • 2016
  • Low Impact Development (LID) techniques are eco-friendly storm water management process for water circulation restoration and non-point pollutant reduction. In this study, four LID techniques (Small constructed wetland, Infiltration trench box, Infiltration trench, Vegetated swale) were selected and installed as a real size at the real site. All facilities were evaluated as monitoring under the real environmental climate situation and an artificial rain with exceeding design rainfall. In various rainfall, runoff reduction efficiency and non-point pollutant removal efficiency are increased to the bigger Surface Area of LID (SA)/Catchment Area (CA) ratio and the bigger Storage Volume of LID (SV)/Catchment Area (CA) ratio. Runoff did not occur at all rainfall event (max. 17.2 mm) in infiltration trench and vegetated swale. But Small constructed wetland was more efficient at less than 10 mm, a efficiency of infiltration trench box was similar at different rainfall. Although different conditions (such as structural material of LID, rainfall flow rate, antecedent dry periods), LID techniques are good effects not only water circulation improvement but also water quality improvement.

Application of Percentile Rainfall Event for Analysis of Infiltration Facilities used by Prior Consultation for LID (Low Impact Development)

  • Kwon, Kyung-Ho;Song, Hye-Jin
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.5-12
    • /
    • 2015
  • Purpose: Retention and infiltration of small and frequently-occurring rainfall by LID facilities account for a large proportion of the annual precipitation volume. Based on 4 standard facilities such as Porous Pavement, Infiltration Trench, Cylindrical Infiltration Well, Rectangular Infiltration Well by Seoul Metropolitan Handbook of the Prior Consultation for LID. The total retention volume of each facility was calculated according to the type and size. The Purpose of this study is to find out the quantitative relationship between Percentile Rainfall Event and Design Volume of Infiltration Facilities. Methode: For the estimation of Percentile Rainfall Event, Daily Precipitation of Seoul from 2005 to 2014 was sorted ascending and the distribution of percentile was estimated by PERCENTILE spreadsheet function. The managed Rainfall Depth and Percentile of each facility was calculated at the several sizes. In response to the rainwater charge volume of 5.5mm/hr by the Category "Private large site", the 3 types of facilities were planned for example. The calculated Rainfall Depth and Percentile were 54.4mm and 90% by the use of developed Calculation-Module based on the Spreadsheet program. Result: With this Module the existing Designed Infiltration volume which was introduced from Japan was simply converted to the Percentile-Rainfall-Event used in USA.

Water cycle evaluation of Bioretention based on hydrologic model (수문모형을 기반으로 한 식생저류지 물순환 평가)

  • Kim, Jae Moon;Baek, Jong Seok;Jang, Young Su;Shin, Hyun Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.290-290
    • /
    • 2021
  • 급격한 도시화 및 기후변화로 인한 물순환체계가 왜곡됨에 따라 자연수재해 피해가 급증하고 있어 대응방안으로 저영향개발(Low Impact Development, LID) 기법이 대두되고 있다. LID 요소 기술 중 하나인 식생저류지는 도시 유역내에서 발생하는 유출수를 저류 및 침투하여 우수유출수와 비점오염원으로 인한 오염저감 효과를 지니고 있는 LID 요소이다. 본 연구에서는 식생저류지의 우수유출수의 정량적 저감효과를 분석하기 위해 수문해석 프로그램인 K-LIDM(Korea Low Impact Development Model)을 이용하여 유역 내 식생저류지 배열과 저류용량에 따른 유출저감 효과를 분석하였다. 강우시나리오는 부산지점의 10년, 30년 발생빈도에 대하여 60분, 120분, 180분 확률강우시나리오를 선정하여 적용하였다. 모델링 분석결과 식생저류지 배치에 따라 5 ~ 15 % 이상의 유출저감효과가 산정되었으며, 식생저류지 저류용량에 따라 20 % 이상의 유출저감 효과가 산정되었다. 첨두유출 도달시간은 1.13 ~ 1.86배를 지연하는 결과가 산정되었다. 결과를 통해 식생저류지의 배열과 저류용량에 따라 유출량 저감효과와 첨두유출 도달시간에 영향을 미침을 알 수 있었다. 추후에 다른 매개변수인 식생저류지의 저류깊이, 지반의 침투능 및 유출부의 직경 등 여러 매개변수들을 고려한 연구를 수행한다면 식생저류지의 정량적 물순환 평가가 수행될것으로 사료된다.

  • PDF