• Title/Summary/Keyword: low frequency inverter

Search Result 397, Processing Time 0.028 seconds

Electronic Ballast Design Driven by Low Frequency Square Wave for High Power MHL (고출력 MHL용 구형저주파 구동 방식의 전자식 안정기 설계)

  • Kim, Ki-Nam;Park, Jong-Yun;Choi, Young-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.394-400
    • /
    • 2010
  • In this paper, We proposed electronic ballast that applys Buck Converter operation principle to Full-Bridge inverter. The proposed ballast consists of an EMI Filter, a full-bridge rectifier, a passive power factor correction (PFC) circuit and a full-bridge inverter. The passive PFC is used and a Full-Bridge inverter operation by two frequency. High Side and Low Side switch was driven by high frequency and low frequency and realized buck Converter's operation. The lamp is driven by Low Frequency square wave to avoid Acoustic Resonance. Also, bulk of inductor is reduced by high frequency switching. Performance of the proposed ballast was validated through computer simulation using Pspice, experimentation and by applying it to an electronic ballast for a prototype 700W MHL.

The Output Characteristics Analysis by Cut-off Frequency Set-up of the LCR Filter on NPC Multi-Level Inverter with Trap-Filter (트랩필터를 갖는 NPC멀티레벨 인버터의 LCR필터 차단주파수 설정에 따른 출력특성 분석)

  • Kim, Soo-Hong;Kim, Yoon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.892-897
    • /
    • 2007
  • This paper presents the output filter design and the output characteristic analysis by cut-off frequency set up of the LCR filter on NPC multi-level inverter with trap-filter. The single-phase NPC three-level inverter operates at low switching frequency. The proposed LC trap filter is comprised of a conventional LCR output filter, by using LC trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also. low damping resistor is increased the output filter system. The multilevel inverter system used NPC type inverter in proper system for high power application and controller is used DSP(TMS320C31). The effectiveness of proposed system confirmed the validity through SPICE simulation and experimental results.

Investigation of Low-Frequency Characteristics of Four-Switch Three-Phase Inverter

  • Yuan, Qingwei;Cheng, Chong;Zhao, Rongxiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1471-1483
    • /
    • 2017
  • The low-frequency characteristics of four-switch three-phase (FSTP) inverter are investigated in this paper. Firstly, a general space vector pulse width modulation (SVPWM) directly involved the neutral point voltage of DC-link is proposed, where no sector identifications and trigonometric function calculations are needed. Subsequently, to suppress the DC offset in the neutral point voltage, the relationship between the neutral point voltage and the ${\beta}-axis$ component of the load current is derived, and then a new neutral point voltage control scheme is proposed where no low pass filter is adopted. Finally, the relationship between the load power factor and the maximum linear modulation index of the FSTP inverter is revealed. Since the operational region for the FSTP inverter in low frequency is reduced by the enlarged amplitude of the neutral point voltage, a linear modulation range enlargement scheme is proposed. A permanent magnet synchronous motor with preset rotary speed serves as the low-frequency load of the FSTP inverter. Experimental results verify that the new neutral point voltage control scheme is effective in the deviation suppression of the neutral point voltage, and the proposed scheme is able to provide a larger linear operational region in low frequency.

High-Frequency DC Link Inverter for Grid-Connected Photovoltaic System (고주파링크방식을 이용한 PV용 PCS의 고찰)

  • Jung, Young-Seok;Yu, Gwon-Jong;Jung, Myoung-Woong;Choi, Jae-Ho;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1313-1315
    • /
    • 2002
  • This paper proposes an inverter for the grid-connected photovoltaic system based on the transformer-less inverter. This system consists of a high frequency inverter bridge, high frequency transformer, diode bridge rectifiers, a DC filter, a low frequency inverter bridge, and an AD filter. The high frequency inverter bridge switching at 20kHz is used to generate bipolar PWM pulse, which is subsequently rectified by diode bridge rectifiers to result in a full-wave rectified sine wave. Finally, it is unfolded by a low frequency inverter bridge to result in a 60Hz sine wave power output. In this paper, the control algorithm for synchronous current feedback control method and a maximum power point tracking (MPPT) method using DSP are described. And, the simulation and experimental results are shown to verify the validity of the proposed system.

  • PDF

A Study on Commercial Frequency Source with High Frequency Resonant Type using ZCS (ZCS를 이용한 고주파 공진형 상용주파수 전원에 관한 연구)

  • Kim, Jong-Hae;Kim, Dong-Hui;No, Chae-Gyun;Gu, Tae-Geun;Bae, Sang-Jun;Lee, Bong-Seop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.448-454
    • /
    • 1999
  • This paper describes a new dc-ac inverter system which for achieving sinusoidal ac waveform makes use of parallel loaded high frequency resonant inverter consisting of full bridge. Each one of the pair of switches in the inverter is driven to synchronous output frequency and the other is driven to PWM signal with resonant frequency proportional to magnitude of sine wave. A forced discontinuous conduction mode is used to realize the quasi-sinusoidal pulse in each switching period. Therefore the inverter generates sinusoidal modulated output voltage including carrier frequency that is resonant frequency. Carrier frequency components of modulated output voltage is filtered by low pass filter. Since current through switches is always zero at its turn-on in the proposed inverter, low stress and low switching loss is achieved. Operating characteristics of the proposed system is analyzed in per unit system using computer simulation. The output voltage of if includes low harmonics and it is almost close to sine wave. Also, the theoretical analysis is proved through the experimental test.

  • PDF

Cascade 3-Phase IHCML Inverter using maximal distension vector control (최근접 벡터 제어기법을 이용한 Cascade 3상 IHCML 인버터)

  • Song, Sung-Geun;Park, Sung-Jun;Nam, Hae-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.187-189
    • /
    • 2007
  • In this paper, the cascade 3-phase IHMCL inverter using two low frequency transformers is proposed. The proposed inverter is constructed by connecting a 3-phase IHCML inverter. the cascade 3-phase IHCML inverter has several advantages. One advantage is that only one input power source is required because of using transformers to isolate. Another advantage is that the switching frequency of the high power switches is almost fundamental frequency of reference and the other the switching frequency of the low power switches is higher. It can be known that cascade 3 phase IHCML inverter has the excellent efficiency and the outstanding electric quality. lastly, we tested the 5kW cascade 3-phase IHCML inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed inverter.

  • PDF

Digital Control of Low-Frequency Square-Wave Two-Stage Electronic Ballast for HID Lamps with Resonant Ignition and High Efficiency (공진 점등 기능과 효율 향상을 위한 HID 램프의 저주파수 구형파 2단 전자식 안정기)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.69-76
    • /
    • 2013
  • In this paper, electronic ballast using resonant inverter for HID lamp is designed and implemented. The proposed electronic ballast is used the soft switching technology ZVS(Zero Voltage Switching) to reduce turn-on and turn-off loss. The ignition of proposed electronic ballast is achieved by controlling a full bridge inverter which is consisted of LC filter for resonance. After ignition the ballast operates as a low frequency square wave inverter by controlling a full bridge inverter as a buck converter. After ignition at resonant frequency of $f_o$=160kHz, the switching frequency of a buck converter is consisted of 50kHz of high frequency and 170Hz of low frequency. This is for attenuating high frequency harmonics and avoiding acoustic resonance. The experimental results show that electronic ballast using resonant inverter is operated stably.

3kW multi-string photovoltaic inverter design and simulation (3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션)

  • Lee, Jong-In;Yu, Beyng-Gyu;Yu, Gwen-Jong;Kim, Heung-Geun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

Torque ripple reduction in DTC of induction motor driven by 3-level inverter with low switching frequency (3레벨 인버터로 구동되는 유도전동기 직접토크제어의 낮은 스위칭 주파수에서의 토크 리플 저감법)

  • 송중호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.203-206
    • /
    • 2000
  • This paper presents a torque ripple reduction technique of direct torque control(DTC) for high power induction motors driven by 3-level inverters with the inverter switching frequency limited around 0.5-1kHz level. It is noted that conventional DTC algorithms to reduce torque ripple are devised for applications with relatively high switching frequency above 2-3kHz. A new DTC algorithms especially for low switching frequency inverter system illustrates relatively reduced torque ripple are devised for applications with relatively high switching frequency above 2-3kHz. Anew DTC algorithm especially for low switching frequency inverter system illustrates relatively reduced torque ripple characteristics Simulation and experimental results show the effectiveness of the proposed control algorithm

  • PDF

A New Simplified Vector Control For A High Performance Common-Arm IHCML Inverter (고성능 공통암 IHCML 인버터를 위한 새로운 벡터 제어 방식)

  • Song, Sung-Geun;Park, Sung-Jun;Nam, Hae-Kon;Kim, Kwang-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1071-1079
    • /
    • 2007
  • In this paper, a novel space vector control method for isolated multi-level inverter using 3-phase low frequency transformers is proposed. This method is based on the simplification of the space-vector diagram of a five-level inverter using calculated table into fully programming method. The execution time of the proposed method is about same as that of the method using calculated table. Also, the proposed method is easily applied to other case level inverter. We applied this method into the 3-phase IHCML inverter using common arm. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformers could be reduced compare with an exiting 3-phase multi-level inverter using single phase transformer. In addition, this method generates very low harmonic distortion operation with nearly fundamental switching frequency. Finally, We tested multi-level inverter to clarify electric circuit and reasonableness through Matlab simulation and experiment by using prototype inverter.