• 제목/요약/키워드: low frequency

검색결과 11,373건 처리시간 0.034초

Research of the Mechanism of Low Frequency Oscillation Based on Dynamic Damping Effect

  • Liu, Wenying;Ge, Rundong;Zhu, Dandan;Wang, Weizhou;Zheng, Wei;Liu, Fuchao
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1518-1526
    • /
    • 2015
  • For now, there are some low frequency oscillations in the power system which feature low frequency oscillation with positive damping and cannot be explained by traditional low frequency oscillation mechanisms. Concerning this issue, the dynamic damping effect is put forward on the basis of the power-angle curve and the study of damping torque in this article. That is, in the process of oscillation, damping will dynamically change and will be less than that of the stable operating point especially when the angle of the stable operating point and the oscillation amplitude are large. In a situation with weak damping, the damping may turn negative when the oscillation amplitude increases to a certain extent, which may result in an amplitude-increasing oscillation. Finally, the simulation of the two-machine two-area system verifies the arguments in this paper which may provide new ideas for the analysis and control of some unclear low frequency phenomena.

Evaluation and Comparison of the Low-Frequency Oscillation Damping Methods for the Droop-Controlled Inverters in Distributed Generation Systems

  • Tao, Yong;Deng, Yan;Li, Guangdi;Chen, Guipeng;He, Xiangning
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.731-747
    • /
    • 2016
  • The droop-based control strategy is widely applied in the interfacing inverters for distributed generation. This can be a problem since low-frequency stability issues may be encountered in droop-based microgrid. The objective of this paper is to classify, evaluate and compare various low-frequency damping methods. First, low-frequency stability problems are analyzed and an equivalent model of a droop-controlled inverter is investigated to classify the damping methods into the source-type damping strategies and the impedance-type damping strategies. Moreover, the lead-lag compensation network insertion control is proposed as a beneficial part of the source-type damping strategies. Then, the advantages and disadvantages of the different types of damping methods are theoretically evaluated and experimentally tested. Furthermore, the damping methods are comprehensively compared to illustrate the application field of each method. Finally, the synthesis of different damping methods to enhance the low-frequency stability is discussed and experimental validation is presented.

은침점전기자극의 인체적용이 신사구체여과율(Glomerular Filtration Rate)에 미치는 효과 (Effects of Silver Spike Point Electrical Stimulation on Glomerular Filtration Rate in Volunteer)

  • 천기영;김순희;민경옥;최영덕;이준희;김중환
    • 대한물리치료과학회지
    • /
    • 제11권1호
    • /
    • pp.28-35
    • /
    • 2004
  • The purpose of the present study was to investigate the effectiveness of silver spike point (SSP) low frequency electrical stimulation on glomerular filtration rate (GFR), specifically, such as diuretic action in 24 hour urine and in plasma analysis from normal volunteer. The current of 1 Hz continue type (CT) of SSP low frequency electrical stimulation significantly decreased in plasma creatine from normal volunteer. However, the urine creatinine clearance (Ccr) was significantly increased by SSP low frequency electrical stimulation in normal volunteer. These results suggest that the SSP low frequency electrical stimulation, especially current of 1 Hz continue type, significantly regulates urine creatinine clearance and glomerular filtration rate from normal volunteer. Therefore, the SSP low frequency electrical stimulation is a good regulator through a diuretic action of hypertension.

  • PDF

${\beta}-Endorphin$의 내피세포의존성-세로토닌 유도-근 수축 억제와 저빈도-주파수 은침점전자극의 혈장 ${\beta}-endorphin$ 증가 (Inhibition of Endothelial Cell-dependent Serotonin-induced Contraction of ${\beta}-endorphin$ and Increment of Plasma ${\beta}-endorphin$ of Silver Spike Point Low Frequency Electrical Stimulation)

  • 최영덕;이준희;김중환
    • The Journal of Korean Physical Therapy
    • /
    • 제16권3호
    • /
    • pp.22-31
    • /
    • 2004
  • The purpose of this study was to demonstrate the effects of silver spike point (SSP) low frequency electrical stimulation on plasma ${\beta}-endorphin$ activities measured by radio- immunoassay from normal volunteer and the effects of ${\beta}-endorphin$ on 5-hydroxytryptamine (5-HT, serotonin)-induced contraction investigated by isometric tension methode in rats. The current of 3 Hz continue type, but not 100 Hz continue type, of SSP low frequency electrical stimulation significantly increased in plasma ${\beta}-endorphin$ from normal volunteer. The endothelial cell-dependent 5-HT-induced contractions were inhibited by ${\beta}-endorphin$ $1{\mu}M$. These results suggest that the ${\beta}-endorphin$ regulates nociceptive-like substance, such as 5-HT, in part and that the SSP low frequency electrical stimulation, specifically current of low frequency of 3 Hz continue type, significantly increases plasma ${\beta}-endorphin$ from normal volunteer.

  • PDF

근전도 스펙트럼 분석을 이용한 만성 요통 환자의 요부근육과 복부근육의 피로도 분석 (A Study of Muscle Fatigue in Lumbar and Abdominal Muscles in Patients with Chronic Low Back Pain by Electromyographic Power Spectral Analysis)

  • 남기석;이영희;이충휘;조상현
    • 한국전문물리치료학회지
    • /
    • 제6권2호
    • /
    • pp.16-31
    • /
    • 1999
  • The purpose of this study was to assess the fatigue in lumbar and abdominal muscles in patients with chronic low back pain compared with normal subjects using spectral analysis with mean power frequency and median power frequency. The experimental group consisted of twenty subjects who had experienced chronic low back pain for over one year after the onset day. A control group consisted of twenty normal subjects with no history of low back pain. All subjects stood in an apparatus to perform sustained contraction in the lumbar and abdominal muscles for 30 seconds with 60% maximal voluntary isometric contraction (MVIC). The resulting electromyographic (EMG) recorded time serial data were transformed into frequency serial data by Fast Fourier Transformation (FFT). The results were as follows: 1) lumbar muscles measured, the frequency change ratio of both median power frequency and mean power frequency was significantly greater for experimental group compared with control group group (p<0.05). In measured two abdominal muscles (inferior rectus abdominis, obliquus externus abdominis) except superior rectus abdominis, the frequency change ratio of both median power frequency and mean power frequency was significantly greater for experimental group compared with control group (p<0.05). 2) In all three (longissimus thoracis, iliocostalis lumborum, multifidus) lumbar muscles measured, the initial frequency value of both median power frequency and mean power frequency was significantly lower for the experimental group compared with the control group (p<0.05). In the two (inferior rectus abdominis, obliquus externus abdominis) abdominal muscles measured (superior rectus abdominis not included), the initial frequency value of both median power frequency and mean power frequency was significantly lower for the experimental group compared with the control group (p<0.05). These results suggest that in patients with chronic low back pain there is a trend for more fatigue to occur in both lumbar and abdominal muscles than in the normal control group. This would seem to suggest that in treatment programs for patients with chronic low back pain, improvement of endurance in all trunk muscles should be considered.

  • PDF

Low Frequency Roll Motion of a Semi-Submersible Moored in Irregular Waves

  • Hong, Yong-Pyo;Choi, Yong-Ho;Lee, Dong-Yeon;Lee, Wang-Keun
    • Journal of Ship and Ocean Technology
    • /
    • 제11권3호
    • /
    • pp.1-13
    • /
    • 2007
  • A semi-submersible drilling rig is regarded as one of the typical offshore structures operated in the field with moderate environments such as the Gulf of Mexico, Brazil, and West Africa. Its typical roll and pitch natural periods are around 30 seconds, which avoids prevailing regions of the wave energy spectrum, and their responses in waves are quite acceptable for common operation conditions. But large roll and pitch motions can be induced by wave difference frequency energy spectrum if the metacentric heights of a semi-submersible decrease to small values in some loading conditions, and it is because the roll and pitch natural periods increase and approach to the region where the spectral density of the low frequency wave drift moment has significant value. This paper describes the low frequency roll motion of a semi-submersible that are excited by the wave 2nd order difference frequency energy by a series of model experiments. From the model tests with several different initial metacentric heights (GM), it was observed that a semi-submersible can experience large roll motion due to the wave group spectrum.

상완이두근의 등장성 운동시 근피로인자로서 표면근전도의 저주파수대역 선정에 관한 연구 (A Study on Low Frequency Band Selection as a Fatigue Parameter in Surface EMG during Isotonic Exercise of Biceps Brachii Muscle)

  • 이상식;이기영
    • Journal of Biosystems Engineering
    • /
    • 제36권4호
    • /
    • pp.285-289
    • /
    • 2011
  • Muscle fatigue is characterized as a progressive increase in discomfort arising from the active muscle at moderate load levels are maintained. The median frequency is the most commonly used as a parameter to describe muscle fatigue. However, the estimate of the median frequency is difficult to indicate muscle fatigue because of its high standard deviation and instability. This paper investigates the power changes of the appropriate low frequency band as a fatigue parameter in EMG during isotonic exercise. To select the appropriate band, linear regression lines are employed to calculate the slopes and the coefficient of determination. Three females and seven males volunteered to participate in surface EMG recordings placed on the biceps brachii and each recording experiment continued until their exhaustion. The results of experiment shows that the power changes of the selected low frequency band (15~45 Hz) have linear slopes and high determinant coefficients. Therefore, this fatiguing parameter using the power changes of the low frequency band is valid to measure the state of muscular fatigue.

큰 반경의 원운동을 하는 점 음원에 의한 저주파수 스위싱 음장 분석 (Study on Low Frequency Swishing Sound Field by a Singularity in Circular Motion with Large Radius)

  • 이광세;정철웅
    • 한국소음진동공학회논문집
    • /
    • 제24권7호
    • /
    • pp.569-574
    • /
    • 2014
  • In order to investigate low frequency swishing noise of wind turbines, acoustic source model using a singularity in circular motion is introduced to derive analytic solution of Lowson acoustic analogy in time domain. Results in time and frequency domains computed by the solution show apparent modulation of amplitude and frequency. The solution indicates that time histories of acoustic pressure at receiver points varied significantly according to receiver's directional location, even when the retarded time distributions are similar. However, the corresponding time-averaged spectra of sound pressure at the receiver locations where the retarded time distributions are almost same are not significantly different. It can be inferred from these results that the time-averaged sound pressure spectra which cannot take into account the detailed difference in the time-variation of wind turbine noise may not represent the sound quality of wind turbines due to its swishing. Finally, as an introduction of procedure to quantify low frequency swishing noise level, relative variation of overall sound pressure level is obtained using tonal low frequency noise model.

Correction of resonance frequency for RF amplifiers based on superconducting quantum interference device

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Lee, S.K.;Chong, Y.;Oh, S.J.;Semertzidis, Y.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.6-10
    • /
    • 2018
  • Low-noise amplifiers in the radio-frequency (RF) band based on the direct current (DC) superconducting quantum interference device (SQUID) can be used for quantum-limited measurements in precision physics experiments. For the prediction of peak-gain frequency of these amplifiers, we need a reliable design formula for the resonance frequency of the microstrip circuit. We improved the formula for the resonance frequency, determined by parameters of the DC SQUID and the input coil, and compared the design values with experimental values. The proposed formula showed much accurate results than the conventional formula. Minor deviation of the experimental results from the theory can be corrected by using the measured geometrical parameters of the input coil line.

합곡에 대한 유침, 저주파 및 고주파 전침이 흰쥐의 장운동에 미치는 영향 (Effect of Pre-treatment or Post-treatment of Acupuncture, Low Frequency Electro-acupuncture and High Frequency Electro-acupuncture at $LI_4$ on Intestinal Motility in Rats)

  • 남세현;이현
    • Journal of Acupuncture Research
    • /
    • 제25권4호
    • /
    • pp.11-29
    • /
    • 2008
  • Objectives : The purpose of this study was to observe the effects of acupuncture and electro-acupuncture at $LI_4$ on intestinal motility in rat. Methods : We made over-activated state of intestinal motility with carbachol and suppressed state of intestinal motility with loperamide in rat and carried out needle retention acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture at $LI_4$ or sham point in rat devided into pre-treatment group and post-treatment group. and we resulted as follow for measuring charcoal travel rate to observe intestinal motility. Results : 1. Any of needle retention acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture at $LI_4$ have no significant influences on intestinal motility of rat in normal state. 2. All of the pre-treatment and post-treatment of needle retention acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture didn't significantly decrease intestinal motility in rat which over-activated with carbachol. 3. Pre-treatment of needle retention acupuncture and high frequency electro-acupuncture significantly increased intestinal motility in rat which suppressed with loperamide. 4. Post-treatment of needle retention acupuncture, low frequency electro-acupuncture and high frequency electro-acupuncture significantly increased intestinal motility in rat which suppressed with loperamide. Conclusions : These results suggest that acupuncture on $LI_4$ have preventive effect and therapeutic effect on suppressed intestinal motility, and especially high frequency electro-acupuncture is more effective.

  • PDF