• Title/Summary/Keyword: low frequencies

Search Result 1,468, Processing Time 0.028 seconds

A New Method for Measuring the Distortions of the Loudspeaker at Low Frequencies (스피커의 저주파 대역 왜곡 측정의 새로운 기법)

  • 두세진
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.68-72
    • /
    • 1993
  • A method to measure the distortions of the loudspeaker at low frequencies without an anechoic chamber is proposed. This method utilizes the fact that the n-th harmonic distortion outside the enclosure is boosted by 40log n dB compared to that inside the enclosure. By compensating for the effect of standing waves occuring inside the enclosure, it is possible to predict the distortions for wide frequency ranges below the first break-up frequency of the diaphragm. The method is applicable to the intermodulation distortion as well.

  • PDF

E-band low-noise amplifier MMIC with impedance-controllable filter using SiGe 130-nm BiCMOS technology

  • Chang, Woojin;Lee, Jong-Min;Kim, Seong-Il;Lee, Sang-Heung;Kang, Dong Min
    • ETRI Journal
    • /
    • v.42 no.5
    • /
    • pp.781-789
    • /
    • 2020
  • In this study, an E-band low-noise amplifier (LNA) monolithic microwave integrated circuit (MMIC) has been designed using silicon-germanium 130-nm bipolar complementary metal-oxide-semiconductor technology to suppress unwanted signal gain outside operating frequencies and improve the signal gain and noise figures at operating frequencies. The proposed impedance-controllable filter has series (Rs) and parallel (Rp) resistors instead of a conventional inductor-capacitor (L-C) filter without any resistor in an interstage matching circuit. Using the impedance-controllable filter instead of the conventional L-C filter, the unwanted high signal gains of the designed E-band LNA at frequencies of 54 GHz to 57 GHz are suppressed by 8 dB to 12 dB from 24 dB to 26 dB to 12 dB to 18 dB. The small-signal gain S21 at the operating frequencies of 70 GHz to 95 GHz are only decreased by 1.4 dB to 2.4 dB from 21.6 dB to 25.4 dB to 19.2 dB to 24.0 dB. The fabricated E-band LNA MMIC with the proposed filter has a measured S21 of 16 dB to 21 dB, input matching (S11) of -14 dB to -5 dB, and output matching (S22) of -19 dB to -4 dB at E-band operating frequencies of 70 GHz to 95 GHz.

AC Electrical Treeing Phenomena in an Epoxy System with Low-chlorine BDGE at Various Electric Field Frequencies

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.324-328
    • /
    • 2013
  • An alternating current (AC) electrical treeing phenomena in an epoxy system with low chlorine BDGE (1,4-butanediol diglycidyl ether) was studied in a needle-plate electrode arrangement. To measure the treeing propagation rate and breakdown time, a constant AC of 10 kV with three different electric field frequencies (60, 500, and 1,000 Hz) was applied to the needle-plate electrode specimen at $130^{\circ}C$ in aninsulating oil bath. The treeing propagation rate of the DGEBA/high-chlorine BDGE system was higher than that of the DGEBA/low-chlorine BDGE system and the breakdown time of the system with high-chlorine BDGE was lower than that of the system with low-chlorine BDGE. These results implied that chlorine had a negative effect on the electrical insulation property of the epoxy system. As the electric field frequency increased, the treeing propagation rate increased and the breakdown time decreased.

Unsteady Analysis of Acoustic-Pressure Responses of $N_{2}$ Diluted $H_{2}$ and Air Diffusion Flames (희석된 수소/공기 확산화염의 비정상 음향파 응답특성 해석)

  • Sohn, Chae-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.320-325
    • /
    • 2003
  • Acoustic-Pressure Response of diluted hydrogen-air diffusion flames is investigated numerically by adopting a fully unsteady analysis of flame structures. In the low-pressure regime, the amplification index remains low and constant at low frequencies. As acoustic frequency increases, finite-rate chemistry is enhanced through a nonlinear accumulation of heat release rate, leading to a high amplification index. Finally, the flame responses decrease at high frequency due to the response lag of the transport zone. For a medium-pressure operation and low-frequency excitation, the amplification index is low and constant. It then decreases at moderate frequencies. As frequency increases further, the amplification index increases appreciably due to an intense accumulation effect.

  • PDF

Synoptic Climotological Characteristics of Winter Droughts in Korea (한국의 동계한발의 종관기후학적 특성)

  • Yang, Jin-Suk
    • Journal of the Korean association of regional geographers
    • /
    • v.11 no.4
    • /
    • pp.429-439
    • /
    • 2005
  • The propose of this study is to identify distributional characteristics of winter droughts through occurrence frequencies and to analyze synoptic characteristics on the sea level pressure fields and 500hPa levels in Korea. The regional distributions of winter droughts in occurrence frequency vary according to the monthly regional distributions of the variabilities of precipitation in Korea. In January and December, the eastern parts of Korea where the variabilities of precipitation show high, have high rate of drought frequencies, while the western parts have low rate of it. It means that the regional distribution of the drought frequencies in January and December shows the east-high and west-low pattern, In February the frequencies show the north-high and south-low pattern. In the distributions of the sea-level pressure and 500hPa level height anomalies, the positive anomalies appear around Korean Peninsula and Siberian high area, the negative anomalies on the Aleutian low area and the western parts of North Pacific Ocean during the drought period in January and February. The droughts appear when the inflow of warm and humid air from the south eastern parts blocked by the prevailing pressure patterns of the west-high and east-low. Therefore, the zonal wind of the Korean Peninsula is strong. The droughts of December reflect not only low frequencies of cyclone occurrence, also small inflow of warm and humid air from the southern parts stemming from positive anomalies over whole middle latitude of eastern parts of Asia including Korean Peninsula.

  • PDF

Motion of a System with Varying Stiffness/Damping Subject to Harmonic Force (변화하는 강성/감쇠를 갖는 계가 조화력을 받을 때의 운동)

  • Lee, Gun-Myung;Park, O-Cheol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.9 s.114
    • /
    • pp.958-963
    • /
    • 2006
  • The motion of a system composed of a plate, constant springs and varying dampers is considered when the system is subject to harmonic force. Letting the frequencies of harmonic force and damper variation $f_1\;and\;f_2$, respectively, the displacement at the center of the plate has the strongest component at frequency $f_1$. The angular displacement of the plate has strong components at $f_1-f_2$ and the natural frequency of the rotational mode of the system. If these two frequencies coincide, the plate oscillates with almost single frequency and a large amplitude. These results can be applied to development of a moment shaker with low frequencies.

Isolation of the Open and Infilled Trenches for the Surface-Waves Induced by the Traffic Loads (교통하중에 의한 지반진동의 차단에 관한 연구)

  • Lee, Phil-Kyu;Kim, Moon-Kyum;Kwon, Hyung-Oh
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1900-1906
    • /
    • 2000
  • In this study, the vibration screening effectiveness of barriers which can isolate structures from ground-transmitted vibration generated by harmonic forces is performed. For high frequencies, the vibration screening effectiveness of barriers is analyzed from field tests, and compared with the results from numerical analyses using a commercial program, ANSYS. Using these numerical analysis procedures, the effectiveness for vibration with various low frequencies is predicted. The frequency analysis tests of surface waves are performed in order to estimate the dynamic material properties of soil for 100 Hz, 150 Hz, 200 Hz, and 250 Hz. Three-dimensional solid elements are used in order to consider the diffraction of waves in all directions. Spring-damper combination elements are used in order to avoid the reflection of waves on the boundary. The results of numerical analysis agree with those of field tests. From the results of this numerical analyses, the reduction of vibration for low frequencies induced by the traffic loads can be predicted.

  • PDF

Motion of a System with Varying Stiffness/Damping Subject to Harmonic Force (변화하는 강성/감쇠를 갖는 계가 조화력을 받을 때의 운동)

  • Lee, Gun-Myung;Park, O-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.81-85
    • /
    • 2006
  • The motion of a system composed of a plate, constant springs and varying dampers is considered when the system is subject to harmonic force. Letting the frequencies of harmonic force and damper variation ${\Large f}_1\;and\;{\Large f}_2$, respectively, the displacement at the center of the plate has the strongest component at frequency ${\Large f}_1$. The angular displacement of the plate has strong components at ${\Large f}_1-{\Large f}_2$, and the natural frequency of the rotational mode of the system. If these two frequencies coincide, the plate oscillates with almost single frequency and a large amplitude. These results can be applied to development of a moment shatter with low frequencies.

  • PDF

Design and FEM Analysis of Langevin Type Ultrasonic Vibrator (란쥬반형 초음파 진동자의 설계와 유한요소 해석)

  • 박민호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.525-528
    • /
    • 2000
  • Piezoelectric ceramics can provide electro-mechanical transduction with high stresses but low displacement. To obtain larger displacements, several mechanical amplifying structures have been used. High alternating displacements can be obtained using resonant structure. In this paper, we designed three kinds of the bolt-tightened Langevin type ultrasonic vibrators whose resonant frequencies are 30[kHz], 40[kHz]. FEM(Finite Element Methode) was employed to calculated the resonant frequencies and maximum displacements of designed vibrators. The designed resonant frequencies and computer calculated frequencies were coincided. When input voltages were increased, maximum displacements were also raised. ANSYS was used to find resonant frequencies and calculate displacements of vibrators.

  • PDF

Optimal placement and tuning of multiple tuned mass dampers for suppressing multi-mode structural response

  • Warnitchai, Pennung;Hoang, Nam
    • Smart Structures and Systems
    • /
    • v.2 no.1
    • /
    • pp.1-24
    • /
    • 2006
  • The optimal design of multiple tuned mass dampers (multiple TMD's) to suppress multi-mode structural response of beams and floor structures was investigated. A new method using a numerical optimizer, which can effectively handle a large number of design variables, was employed to search for both optimal placement and tuning of TMD's for these structures under wide-band loading. The first design problem considered was vibration control of a simple beam using 10 TMD's. The results confirmed that for structures with widelyspaced natural frequencies, multiple TMD's can be adequately designed by treating each structural vibration mode as an equivalent SDOF system. Next, the control of a beam structure with two closely-spaced natural frequencies was investigated. The results showed that the most effective multiple TMD's have their natural frequencies distributed over a range covering the two controlled structural frequencies and have low damping ratios. Moreover, a single TMD can also be made effective in controlling two modes with closely spaced frequencies by a newly identified control mechanism, but the effectiveness can be greatly impaired when the loading position changes. Finally, a realistic problem of a large floor structure with 5 closely spaced frequencies was presented. The acceleration responses at 5 positions on the floor excited by 3 wide-band forces were simultaneously suppressed using 10 TMD's. The obtained multiple TMD's were shown to be very effective and robust.