Ultraviolet A Induces Immunosuppression, Protection or Memory Enhancement Depending on Dose, while Ultraviolet B is Immunosuppressive and Tolerogenic over a Large Dose Range

  • Halliday, Gary M.;Byrne, Scott N.
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.197-200
    • /
    • 2002
  • UVR-induced immunosuppression contributes to skin cancer. The aim was to construct accurate dose response curves for primary and secondary contact sensitivity for solar-simulated UVR (ssUVR; 290-400nm), UVA and UVB as the role of UVA in immunosuppression is controversial. We used a xenon arc source. The mice were immobilised, enabling accurate dosing. C57BL/6 mice were immunosuppressed at half the dose of ssUVR required to cause sunburn but not by higher doses (up to the sunburn dose). Thus, ssUVR causes systemic immunosuppression only over a narrow, low dose range. UVA caused suppression at low but not high doses whereas UVB induced immunosuppression at all doses tested. 8 weeks later the mice were resensitised to assess tolerance. Mice exposed to the minimum immunosuppressive dose of ssUVR prior to primary sensitisation were tolerant to re-sensitisation. However, at higher doses of ssUVR, these mice were protected from tolerance. Interestingly, while low doses of UV A caused immunosuppression, even lower doses enhanced the response to the second sensitisation. Higher doses of UVA had no affect. UVB induced tolerance in a dose related manner. Thus, ssUVR only induces immunosuppression and tolerance over a narrow dose range. Both UVA and UVB are immunosuppressive at this dose, while higher doses of UVA protect from the suppressive effects of UVB. Surprisingly very low doses of UVA enhanced memory development. Thus UVR has complex effects on the immune system depending on dose and spectrum.

  • PDF

Risk Assessment from Heterogeneous Energy Deposition in Tissue. The Problem of Effects from Low Doses of Ionizing Radiation

  • Le, Feinendegen;J, Booz
    • 대한핵의학회지
    • /
    • 제26권1호
    • /
    • pp.8-13
    • /
    • 1992
  • Low doses of ionizing radiation from external or internal sources cause heterogeneous distribution of energy deposition events in the exposed biological system. With the cell being the individual element of the tissue system, the fraction of cells hit, the dose received by the hit, and the biological response of the cell to the dose received eventually determine the effect in tissue. The hit cell may experience detriment, such as change in its DNA leading to a malignant transformation, or it may derive benefit in terms of an adaptive response such as a temporary improvement of DNA repair or temporary prevention of effects from intracellular radicals through enhanced radical detoxification. These responses are protective also to toxic substances that are generated during normal metabolism. Within a multicellular system, the probability of detriment must be weighed against the probability of benefit through adaptive responses with protection against various toxic agents including those produced by normal metabolism. Because irradiation can principally induce both, detriment and adaptive responses, one type of affected cells may not be simply summed up at the expense of cells with other types of effects, in assessing risk to tissue. An inventory of various types of effects in the blood forming system of mammals, even with large ranges of uncertainty, uncovers the possibility of benefit to the system from exposure to low doses of low LET radiation. This experimental approach may complement epidemiological data on individuals exposed to low doses of ionizing radiation and may lead to a more rational appraisal of risk.

  • PDF

Non-linear Responses of Hordeum vulgare Germs to Low Doses of Ionizing Radiation

  • Kim, Jin-Kyu;Alla A. Oudalova;Vladimir G. Dikarev
    • 환경생물
    • /
    • 제21권4호
    • /
    • pp.384-391
    • /
    • 2003
  • The induction of chromosome aberrations in Hordeum vulgare germs after irradiation is studied for the dose range of 10 to 1,000 mGy. The relationship between the frequency of aberrant cells and the absorbed dose is shown to be non -linear and has a dose-independent plateau within the range of 56-467 mGy where the level of cytogenetic damage is statistically significantly distinguished from the spontaneous level. The comparison of the goodness of the experimental data fitting with mathematical models of different complexities, using the most common quantitative criteria, demonstrates the benefit of the piecewise linear model over the linear and polynomial ones in approximating the cytogenetical disturbance frequency. The results of our study support the conclusion about indirect mechanism of chromosome aberrations induced by low doses or dose rates mutagenesis.

일반촬영에서 kVp와 mAs의 변화에 따른 농도와 환자 선량 비교 (A Comparison of Density and Patient Doses According to kVp and mAs Changes in General Radiography)

  • 강은보
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.987-994
    • /
    • 2019
  • 일반촬영의 저관전압 촬영에서 발생되는 저 에너지 X-선은 신체에 흡수가 많고 영상 품질 향상에는 도움을 주지 못한다. 본 연구에서는 일반 촬영에서 적정 농도를 유지하면서 환자의 피폭 선량을 줄이기 위해 농도에 따른 관전압 15%법칙과 농도에 비례하는 관전류량을 이용하여 면적 선량과 입사표면선량을 측정하여 환자의 피폭선량을 비교하였다. Hand, Knee, Abdomen, Skull 촬영에서 kVp를 115%까지 증가하면서 mAs를 50%까지 감소시키고, kVp를 85%까지 감소시키고 mAs를 200%까지 증가시키면서 면적선량과 입사표면선량을 측정하여 각각의 선량을 비교하였다. 그리고 각 영상의 5군데를 정하여 농도를 측정하고 Kruskal wallis H 검증을 하여 집단-간의 유의확률을 알아보았다. 농도를 일정하게하기 위해 관전압을 115%로 증가하고, 관전류를 50%로 감소시킨 조건에서 각 부위별 평균 면적선량과 입사표면선량을 측정한 결과 기준 선량을 100%로 할 때 각각 58.68%, 59.85%로 감소하고, 관전압을 85%로 감소하고 관전류를 200%로 증가시킨 조건에서 각각 147.28%, 159.9%로 증가하였다. 농도 변화를 비교한 결과 Hand, Knee, Abdomen, Skull 촬영 모두 유의확률 >0.05 나타나 농도 변화는 없는 것으로 나타났다. 해상력과 대조도에 영향을 주지 않는 범위에서 적정한 계산을 통해 관전압을 증가시키고 관전류를 낮게 해서 촬영하는 것이 적정농도를 유지하면서 환자의 피폭 선량을 줄이는 간단한 방법으로 사료된다.

The Low-Radiation Dosimetry Application of "tris" Lyoluminescence using Electron Paramagnetic Resonance at Low Temperature

  • Son, Phil-Kook;Choi, Suk-Won;Kim, Sung-Soo;Gwag, Jin-Seog
    • Journal of Magnetics
    • /
    • 제17권3호
    • /
    • pp.172-175
    • /
    • 2012
  • We present a method for detecting very weak radiation by analyzing the inner structure of irradiated tris (lyoluminescence) materials using electron paramagnetic resonance (EPR) at low temperature. Organic materials have been looked into for use in emergency dosimetry of inhabitants around radiation accidents. However, this technology has never been applied to imperceptible radiation doses (< 0.5 Gy) because there is no proper method for detecting the change of inner structure of the subject bombed by very weak radiation at room temperature. Our results show that tris materials can be applied as a radiation detectors of very small radiation doses below 0.05 Gray, if EPR is used at low temperature (130 K ${\leq}$ T ${\leq}$ 270 K). The EPR signal intensity from the irradiated-tris sample had barely faded at all after 1 year.

3차원 안모분석을 위한 저선량 Multi-detector CT 영상의 유효선량 및 화질 평가 (Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning)

  • 정기정;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

Hormesis as a Confounding Factor in Epidemiological Studies of Radiation Carcinogenesis

  • Sanders Charles L.
    • Journal of Radiation Protection and Research
    • /
    • 제31권2호
    • /
    • pp.69-89
    • /
    • 2006
  • Biological mechanisms for ionizing radiation effects are different at low doses than at high doses. Radiation hormesis involves low-dose-induced protection and high-dose-induced harm. The protective component is associated with a reduction in the incidence of cancer below the spontaneous frequency, brought about by activation of defensive and repair processes. The Linear No-Threshold (LNT) hypothesis advocated by the International Commission on Radiological Protection (ICRP) and the Biological Effects of ionizing Radiation (BEIR) Report VII for cancer risk estimations Ignores hormesis and the presence of a threshold. Cancer incidences significantly less than expected have been found in a large number of epidemiological studies including, airline flight personnel, inhabitants of high radiation backgrounds, shipyard workers, nuclear site workers in scores of locations throughout the world, nuclear power utility workers, plutonium workers, military nuclear test site Participants, Japanese A-bomb survivors, residents contaminated by major nuclear accidents, residents of Taiwan living in $^{60}Co$ contaminated buildings, fluoroscopy and mammography patients, radium dial painters, and those exposed to indoor radon. Significantly increased cancer was not found at doses <200 $mSv^*$. Evidence for radiation hormesis was seen in both sexes for acute or chronic exposures, low or high LET radiations, external whole- or partial body exposures, and for internal radionuclides. The ubiquitous nature of the Healthy Worker Effect (HWE)-like responses in cellular, animal and epidemiological studies negates the HWE as an explanation for radiation hormesis. The LNT hypothesis is wrong and does not represent the true nature of the dose-response relationship, since low doses or dose-rates commonly result in thresholds and reduce cancer incidences below the spontaneous rate. Radiation protection organizations should seriously consider the cost and health implications of radiation hormesis.

Orthopos$\textregistered$ 파노라마방사선촬영기의 각종 프로그램에 따른 흡수선량 (The absorbed doses from each exposure program of the Orthopos$\textregistered$ panoramic machine)

  • 최순철;이설미
    • Imaging Science in Dentistry
    • /
    • 제31권4호
    • /
    • pp.215-219
    • /
    • 2001
  • Purpose: The objective of this study was to estimate the radiation absorbed doses in certain critical organs in the head and neck region with 16 imaging programs available on the Orthopos/sup (R)/ panoramic machine. Materials and Methods: A Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses were measured at the thyroid gland, the submandibular gland, the parotid gland, the mouth floor. the maxillary sinus, the brain, the mandibular body, the mandibular ramus. the 2nd cervical spine and the skin over TMJ area. Results : The overall absorbed doses with imaging programs available on the Orthopos/sup (R)/ panoramic machine were much less than that of standard program (program 1) except program 8, 11, and 16. Generally, the absorbed doses to the bone marrow of the mandibular ramus and the parotid gland were high, but the absorbed doses to the bone marrow in the mandibular body, brain, maxillary sinus, and, especially, the thyroid gland were very low. Conclusion : The modified imaging programs available on the Orthopos/sup (R)/ panoramic machine can be effectively used in aspect of radiation protection.

  • PDF

파노라마방사선촬영기종에 따른 흡수선량 차이 (Difference in Radiation Absorbed Dose According to the Panoramic Radiographic Machines)

  • 최순철
    • Imaging Science in Dentistry
    • /
    • 제30권1호
    • /
    • pp.11-15
    • /
    • 2000
  • Purpose: The primary objective of this study was to estimate the radiation absorbed doses in certain critical organs in the head and neck region with an Orthopos plus, a Panelipse, and a Panex-E machines. The second objective was to compare the absorbed doses between 5 inch by 12 inch and 6 inch by 12 inch image field for the Orthopos plus. Materials and Methods: Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses were measured at the thyroid gland, the submandibular gland, the parotid gland, the mouth floor, the maxillary sinus, the brain, the mandibular body, the mandibular ramus, the 2nd cervical spine and the skin over TMJ area. Results: The highest absorbed dose value was recorded at the mandibular ramus for the Orthopos plus with narrow image field. Higher absorbed dose values were recorded at the parotid gland, the mouth floor, the submandibular gland, and the 2nd cervical spine. The doses in the parotid gland were 597 μGy and 529 μGy with Orthopos plus, 638 μGy with Panelipse, and 1094μGy with Panex-E. Corresponding figures for the mandibular ramus were 2363 Gy and 1220 μGy, 248 μGy, and 118 μGy. The absorbed doses to the thyroid gland, the maxillary sinus, the brain, and the skin over TMJ were very low. Conclusion: Higher exposure values were recorded for the Orthopos plus than Panelipse and Panex-E. There was no significant differences of the absorbed doses according to the image field size.

  • PDF

최근 개발된 cone beam computed tomography의 흡수선량 및 유효선량 평가 (Absorbed and effective dose from newly developed cone beam computed tomography in Korea)

  • 이종녕;한원정;김은경
    • Imaging Science in Dentistry
    • /
    • 제37권2호
    • /
    • pp.93-102
    • /
    • 2007
  • Purpose: Cone beam computed tomography (CBCT) provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology. The purpose of this study was to evaluate the absorbed and effective doses of Implagraphy and VCT (Vatech Co., Hwasung, Korea) and compare them with those of panoramic radiography. Materials and Methods: Thermoluminescent dosimeter (TLD) chips were placed at 27 sites throughout the layers of Female ART Head and Neck Phantom for dosimetry. Implagraphy, VCT units, and Planmeca Proline XC panoramic unit were used for radiation exposures. Radiation weighted doses and effective doses were measured and calculated using 1990 and 2005 ICRP tissue weighting factors. Results: Effective doses in Sv (ICRP 2005, ICRP 1990) were 90.19, 61.62 for Implagraphy at maxillay molar area, 123.20, 90.02 for Implagraphy at mandibular molar area, 183.55, 139.26 for VCT and 40.92, 27.16 for panoramic radiography. Conclusion: Effective doses for VCT and Implagraphy were only about 2.2 to 4.5 times greater than those for panoramic radiography. VCT and Implagraphy, CBCT machines recently developed in Korea, showed moderately low effective doses.

  • PDF