• Title/Summary/Keyword: low dose gamma radiation

Search Result 232, Processing Time 0.025 seconds

Development and Characterization of a Dosimeter Using Tissue-Equivalent Scintillator by Photon-Counting Method (조직 등가 섬광체를 이용한 계수형 선량계의 개발과 특성 평가)

  • Cheon, Jong-Kyu;Kim, Sung-Hwan;Kim, Hong-Joo
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2014
  • A dosimeter using tissue-equivalent scintillator by photon-counting method was developed and evaluated in its performance. The dosimeter is portable and can be operated by low power from lap-top computer. A data-acquisition software of the dosimeter system was developed by Labwindows/CVI based on Windows. The energy to channel ratio for energy calibration was 0.839 keV/ch. obtained from pulse height spectrum of $^{137}Cs$ and $^{60}Co$ gamma-ray. Using the dosimeter system, the absorbed dose of environmental radiation in Gyungju was 0.18 ${\mu}Sv/h$.

A Study On Radiation Detection Using CMOS Image Sensor (CMOS 이미지 센서를 사용한 방사선 측정에 관한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.193-200
    • /
    • 2015
  • In this paper, we propose the radiation measuring algorithm and the device composition using CMOS image sensor. The radiation measuring algorithm using CMOS image sensor is based on the radiation particle distinguishing algorithm projected to the CMOS image sensor and accumulated and average number of pixels of the radiation particles projected to dozens of images per second with CMOS image sensor. The radiation particle distinguishing algorithm projected to the CMOS image sensor measures the radiation particle images by dividing them into R, G and B and adjusting the threshold value that distinguishes light intensity and background from the particle of each image. The radiation measuring algorithm measures radiation with accumulated and average number of radiation particles projected to dozens of images per second with CMOS image sensor according to the preset cycle. The hardware devices to verify the suggested algorithm consists of CMOS image sensor and image signal processor part, control part, power circuit part and display part. The test result of radiation measurement using the suggested CMOS image sensor is as follows. First, using the low-cost CMOS image sensor to measure radiation particles generated similar characteristics to that from measurement with expensive GM Tube. Second, using the low-cost CMOS image sensor to measure radiation presented largely similar characteristics to the linear characteristics of expensive GM Tube.

Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon (직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가)

  • Jung, hae youn;Seok, jin yong;Hong, joo wan;Chang, nam jun;Choi, byeong don;Park, jin hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose : The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Materials and Methods : Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and $R_{50%}$ was calculated to assess low dose spillage as per treatment plan. $D_{25%}$ of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. Results : There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and $R_{50%}$ on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum $D_{25%}$ was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest time was observed on 1A-VMAT. All plans indicated over 99.5%(p=0.00) of gamma pass rate (2 mm, 2%) in portal dosimetry quality assurance. Conclusion : As a result of study, postoperative prostate cancer radiation therapy for patient using a rectal balloon, there was no significant difference of PTV coverage but 1A-VMAT and 2A-VMAT were more efficient for dose reduction of normal tissue and OARs. Between VMAT plans. $R_{50%}$ and MU were little lower in 2A-VMAT but 1A-VMAT has the shortest delivery time. So it is regarded to be an effective plan and it can reduce intra-fractional motion of patient also.

  • PDF

The Radioprotective Effects of Rhizomata Herbs (대표적 근경류 생약의 방사선 방호효과)

  • Kim, Sung-Ho;Jo, Sung-Kee;Kwon, Oh-Deog
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.13-18
    • /
    • 2001
  • We performed this study to determine the effect of Baizhu (Atractylodes japonica), Chuanxiong (Cnidium officinale), Shanyao (Discorea japonica) and Shengma (Cimicifuga heracleifolia), as Oriental rhizomata herbs, on jejunal crypt survival, endogenous spleen colony formation and apoptosis in jejunal crypt cells of mice irradiated with high and low dose of ${\gamma}$-radiation. Shengma was effective in intestinal crypt survival(p<0.05). The frequency of radiation induced apoptosis was also reduced by pretreatment with Chuanxiong and Shengma(p<0.05). Although the mechanisms of this effort remain to be elucidated, these results indicated that Shengma might be a useful radioprotector, especially since it is a relatively nontoxic natural product.

  • PDF

Changes of Chemical Properties in Processing of Low Salted and Fermented Shrimp Using Gamma Irradiation immediately before Optimum Fermentation (저염 새우젓 제조를 위한 최적 숙성직전의 감마선 조사시 화학적 품질변화)

  • Lee, Kyong-Haeng;Ahn, Hyun-Joo;Lee, Cherl-Ho;Kim, Yeung-Ji;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.1051-1057
    • /
    • 2000
  • Gamma irradiation was applied to develop fermented shrimp product with lower salt concentration, high sensory quality and storage stability. Shrimp was prepared with 15 and 20% of salt and fermented at $15^{\circ}C$. The sample was irradiated for 15% added salt at the 4th week and for 20% at the 6th week during fermentation with 0, 5 and 10 kGy absorbed doses. The irradiation was applied at optimum stage of fermentation determined when the content of amino nitrogen(AN) arrived approximately 400 mg%. Chemical properties such as amino nitrogen(AN), volatile base nitrogen(VBN), trimethylamine(TMA) and neutral protease activity were examined during whole fermentation. The AN, VBN, TMA and protease activity were not affected immediately after gamma irradiation. The more NaCl concentrations and irradiation dose, the less content of chemical compounds and protease activity was found. From the results of chemical properties, it was concluded that fermented shrimp with 15% of salt and irradiated at 10 kGy before optimum fermentation, or 20% and 5 kGy or above were maintained the sound quality during storage compared with the control.

  • PDF

Breeding of four-leaf white clover (Trifolium repens L.) through 60Co gamma-ray irradiation

  • Song, In-Ja;Kang, Hong-Gyu;Kang, Ji-Yeon;Kim, Hae-Deun;Bae, Tae-Woong;Kang, Si-Young;Lim, Pyung-Ok;Adachi, Taiji;Lee, Hyo-Yeon
    • Plant Biotechnology Reports
    • /
    • v.3 no.3
    • /
    • pp.191-197
    • /
    • 2009
  • Four-leaf white clover is not found easily in nature due to its low appearance rate (1 in 10,000). Because people believe that it brings good luck and like to either keep it or present it to a loved one, it has commercial and ornamental value. To breed four-leaf clover, we exposed its flowers to ${\gamma}-rays$ at the pollination stage. The $M_1$ seeds produced following doses at 25-100 Gy showed an approximately 74% germination rate, with seedling survival at 46%. In the $M_1$ generation of plants irradiated within that dose range, we found an increased frequency of four leaflets. One of them, Jeju Lucky-1 (JL-1), had a frequency of about 60%. To see whether that mutation was somaclonal or genetic, we observed its $M_2$ generation and found that such a phenotype reappeared. Although our results demonstrated that the irradiation of fully mature flowers led to a higher frequency of 4-leaflets, we could not clearly explain the genetic mechanism involved. We suggest that JL-1 is valuable as a new variety, without further genetic fixation, because white clover can be propagated vegetatively by stolons.

Luminescence properties and compositions of contaminating inorganic minerals separated from gamma-irradiated fresh and white ginsengs from different areas

  • Ahn, Jae-Jun;Akram, Kashif;Jeong, Mi-Seon;Kwak, Ji-Young;Park, Eun-Joo;Kwon, Joong-Ho
    • Journal of Ginseng Research
    • /
    • v.37 no.4
    • /
    • pp.483-490
    • /
    • 2013
  • Gamma-irradiation (0-7 kGy) of ginseng is permitted in Korea for the purpose of microbial decontamination; with strict labeling, traceability and monitoring requirements. An identification study was conducted to determine the photostimulated-luminescence (PSL) and thermoluminescence (TL) properties of gamma-irradiated fresh and white ginsengs cultivated in different areas. Dose- dependent PSL-based screening was possible for white ginseng samples; however, inappropriate results from non-irradiated fresh ginseng samples were obtained, showing intermediate (700 to 5,000) or positive ($T_2$ >5,000, irradiated) PSL counts due to the abundance of minerals on the surfaces of the samples. TL analysis of separated minerals from all non-irradiated samples gave TL glow curves of low intensity with a maximum peak after $300^{\circ}C$. However, well-defined irradiation-specific (high intensity with a maximum peak at about $200^{\circ}C$) glow curves were observed for all the irradiated samples, regardless of their type and origins. TL ratios (first glow curve /second glow curve) were also determined to confirm the irradiated (>0.1) and non-irradiated (<0.1) results. SEM-EDX (scanning electron microscope-energy dispersive X-ray) and XRD (X-ray diffraction) spectroscopic analyses showed that feldspar and quartz minerals were the main source for the typical radiation-specific luminescence properties.

A Theoretical Calculation for Angular Dependence of X-ray Beams on Extremity Phantom (말단팬텀에서 X-선 빔의 방향의존성에 관한 이론적 계산)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Kim, Jang-Lyul;Kim, Kwang-Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.263-271
    • /
    • 1996
  • The ANSI N13.32 recommends that a study of the angular response of a dosimeter be carried out once, although no pass/fail criterion is given for angular response. Gamma dose equivalent conversion and angular dependence factors were calculated by using MCNP code for the case of ANSI N13.32 extremity phantoms(finger and arm) at the depth of $7mg/cm^2$. Those extremity dosimeters were assumed to be irradiated from both monoenergitic photons and ISO X-ray narrow beams. These calculated gamma dose equivalent conversion and angular dependence factors were compared to B. Grosswendt's result calculated by using X-ray beams. The result showed that the dose equivalent conversion factors of this study agreed well with that of B. Grosswendt for all energies within 2% except 7% in the case of the low energies. In the case of angular dependence factors comparison, they agreed within 3%. It was shown that angular dependence factors of the finger phantom decreased as the horizontal angle of the phantom increased for the ISO X-ray beams less than 60keV. For the higher energy X-ray beams range they decreased slightly around 40 degree, but then increased from this energy to 90 degree.

  • PDF

TID and SEL Testing on PWM-IC Controller of DC/DC Power Buck Converter (DC/DC 강압컨버터의 PWM-IC 제어기의 TID 및 SEL 실험)

  • Lho, Young Hwan;Hwang, Eui Sung;Jeong, Jae-Seong;Han, Changwoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.1
    • /
    • pp.79-84
    • /
    • 2013
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The DC/DC converter is composed of a PWM-IC (pulse width modulation-integrated circuit) controller, a MOSFET (metal-oxide semiconductor field effect transistor), inductor, capacitor, etc. It is shown that the variation of threshold voltage and the offset voltage in the electrical characteristics of PWM-IC increase by radiation effects in TID (Total Ionizing Dose) testing at the low energy ${\gamma}$ rays using $^{60}Co$, and 4 heavy ions applied for SEL (Single Event Latch-up) make the PWM pulse unstable. Also, the output waveform for the given input in the DC/DC converter is observed by the simulation program with integrated circuit emphasis (SPICE). TID testing on PWM-IC is accomplished up to the total dose of 30 krad, and the cross section($cm^2$) versus LET($MeV/mg/cm^2$) in the PWM operation is studied at SEL testing after implementation of the controller board.

Evaluation on the radioprotective effect of Korean favorite teas (한국인 기호 차류의 방사선 장해 경감효과 평가)

  • Kim, Se-Ra;Lee, Hae-June;Oh, Heon;Lee, Jin-Hee;Kim, Hu-Kyung;Kim, Tae-Hwan;Jo, Sung-Kee;Kim, Sung-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.4
    • /
    • pp.475-483
    • /
    • 2002
  • We performed this study to determine the effect of Korean favorite teas (green tea, ginseng tea, coffee and barley tea) on jejunal crypt survival, endogenous spleen colony formation and apoptosis in jejunal crypt cells of mice irradiated with high and low dose of ${\gamma}$-radiation. Jejunal crypts were protected by pretreatment of green tea (P.O.: 1.25% water extract, for 7 days before irradiation., I.P.: 50 mg/kg of body weight, at 12 and 36 hours before irradiation, p<0.01) or ginseng (I.P.: 50 mg/kg of body weight, at 12 and 36 hours before irradiation, p<0.05). Green tea (p<0.05) or ginseng (p<0.05) administration before irradiation (I.P. at 12 and 36 hours before irradiation) resulted in an increase of t formation of endogenous spleen colony. The frequency of radiation-induced apoptosis was also reduced by pretreatment of green tea (P.O.: p<0.005, I.P.: p<0.05), pretreatment of ginseng (P.O.: p<0.005, I.P.: p<0.005) or posttreatment of ginseng (I.P.: 50 mg/kg of body weight, at 30 minutes after irradiation, p<0.05). Treatment with coffee or barley tea showed no significant modifying effects on the radiation-induced damages. These results indicated that green tea and ginseng might be a useful radioprotector, especially since it is a relatively nontoxic natural product. Further studies are needed to characterize better the promotion nature of green tea, ginseng and its components.