방사선(放射線) 조사(照射) 중(中) 절연유(絶緣油)의 유기전류(誘起電流)에 관한 연구(硏究) (A Study on Radition-Induced Current in Insulating Oil during X-ray Irradiation)

  • 김영일;이덕출;정연택
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제11권1호
    • /
    • pp.33-41
    • /
    • 1988
  • This study was measured the radiation-induced current - X-ray dose, dose rate, X-ray quality, time, temperature, electric field characteristics and the dependence of gap length in insulating oil under of D.C. Voltage before, during and after X-ray irradiation. The obtained results can be summarized as following. 1. The radiation - induced current is more the dependence of X-ray quality (tube voltage) than quantity (tube current), the dependence of quantity is appeared at the high than low X-.ay tube voltage. 2. The dependence of dose rate is appeared at the more dose rate, and ${\triangle}\;=\;0.64{\sim}0.74$. 3. The higher temperature of insulating oil and X-ray tube voltage (X-ray quality) is increased, at the low electric field, the more radiation-induced current. 4. $G_{eq}-G_{o}(={\triangle}G)$ is increased at the low than high temperature, high than low X-ray quality. 5. The dependence of temperature is appeared before than during X-ray irradiation. 6. The RIC saturation region is appeared at the high than low insulating oil temperature during (1000 V/cm above) than before (4000 V/cm above) X-ray irradiation.

  • PDF

저선량 X-ray 영상의 잡음 제거를 위한 확률 거리 기반 3차원 비지역적 평균 알고리즘 (3D Non-local Means(NLM) Algorithm Based on Stochastic Distance for Low-dose X-ray Fluoroscopy Denoising)

  • 이민석;강문기
    • 전자공학회논문지
    • /
    • 제54권4호
    • /
    • pp.61-67
    • /
    • 2017
  • 방사선 노출의 위험을 줄이기 위한 저선량 X-ray 영상은 양자노이즈로 인해 화질열화가 발생한다. 본 논문은 저선량 X-ray 기기를 통해 입력받은 저화질의 동영상으로부터 포아송 확률 거리(Stochastic distance)에 기반하여 동영상 X-ray 데이터의 노이즈를 3차원 Non-local Means(3D NLM) 필터를 통해 제거한다. 포아송 확률 거리는 X-ray 영상에서 3D NLM 노이즈 제거 필터의 유사성을 판별하는 척도로써 사용되어 진다. 제안하는 방법은 움직임 정보가 포함된 프레임 유사도를 사용하여 움직임 아티팩트가 최소화된 X-ray 동영상 데이터를 출력하도록 한다. 수행한 결과로 노이즈가 제거된 X-ray 영상을 생성하도록 함으로써, 영상의 열화된 화질을 개선시켜 저선량 X-ray 영상 데이터에 대한 판독 능력을 향상시킬 수 있는 효과가 있다. 제안하는 방법은 객관적인 기준의 수치적인 관점에서 뿐만 아니라, 실제의 X 선 영상 시퀀스의 주관적인 시각적 인식에서도 뛰어남을 확인 할 수 있다.

엑스선에 의한 반도체 소자의 방사선 손상 (Radiation Damage of Semiconductor Device by X-ray)

  • 김동성;홍현승;박혜민;김정호;주관식
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.110-117
    • /
    • 2015
  • 최근 방사선을 이용한 반도체 검사장비 산업의 증가로 이에 대한 기술 연구 수요 또한 증가하고 있다. 반도체 검사장비는 저에너지 엑스선으로 최저 40 keV에서 최고 120 keV의 에너지 영역을 사용하고 있지만, 국내에서는 저에너지 엑스선이 주는 방사선 손상 연구가 미흡한 상황이다. 따라서 본 연구는 저에너지 엑스선을 이용하여 반도체 소자의 한 종류인 BJT (bipolor junction transistor)가 받는 방사선 손상에 관한 것이다. BJT는 NXP반도체사의 BC817-25(NPN type)를 사용하였으며, 엑스선 발생장치를 사용하여 엑스선을 조사하였다. BJT의 방사선 손상 여부는 엑스선 조사 전과 후에 전류 이득을 10으로 고정하고, 콜렉터 전류에 따른 콜렉터-이미터 전압을 측정하여 변화 정도를 분석하여 확인하였다. 엑스선 발생장치의 관전압은 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp 등 다섯 가지로, 조사 시간은 60초, 120초, 180초, 360초, 540초 등 다섯 가지로 변수를 두었다. 실험 결과 BJT에서 저에너지 엑스선 즉, 120 keV 이하의 엑스선을 조사하여도 방사선 손상이 발생하는 것을 확인하였고, 특히 80 kVp에서 가장 큰 방사선 손상이 발생되었다. 이는 ELDRS (enhanced low dose rate sensitivity) 현상이 80 kVp을 기준으로 발생되는 것으로 판단된다. 본 연구의 결과는 저에너지 엑스선을 이용한 반도체 검사장비의 효율적인 선량관리와 엑스선 여과기의 연구 및 개발에 기여할 것으로 기대한다.

Low LET X-ray가 췌장 ${\beta}$ 세포와 신경세포에 미치는 효과 (Effect on Pancreatic Beta Cells and Nerve Cells by Low LET X-ray)

  • 박광훈;김구환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권1호
    • /
    • pp.21-28
    • /
    • 2014
  • 배양된 췌장베타세포와 신경세포를 10% FBS (fetal bovine serum), 11.1 mM glucose의 normal 조건과 1% FBS, 30 mM glucose의 hyperglycemia 조건으로 배양하고, 저 LET X-선을 0.5 Gy/hr의 선량률로 총 선량이 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 4.5, 5 Gy가 되도록 저 LET 방사선을 조사한 후 MTT assay로 생존율을 측정하고 비교하였다. 분화된 췌장베타세포에 방사선을 조사하지 않았을 때는 normal 조건에 비해 hyperglycemia 조건의 생존율이 경미한 감소를 보였다. 그러나 X선의 총 선량이 점차 누적됨에 따라 normal 조건에서 생존율이 조금씩 감소하는 것에 비해 hyperglycemia 조건에서는 급격히 감소하여 시너지 효과를 나타냈다. 미분화된 신경세포에서는 방사선을 조사하지 않은 때도 normal 조건에 비해 hyperglycemia 조건의 생존율이 뚜렷하게 감소하였다. X선의 총 선량이 점차 누적됨에 따라 normal 과 hyperglycemia 조건 모두에서 비교적 급격한 세포사멸이 나타났지만 그 생존율의 감소비율이 거의 평행하게 진행되어 시너지 효과를 보이지 않았다.

동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성 (Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

광자극선량계의 저에너지 엑스선 특성비교 (Measuring Absorbed Dose from Medical X-ray Equipment Using Optically Stimulated Luminescence Dots)

  • 정숙진;진계환
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.79-83
    • /
    • 2018
  • 본 논문에서는 OSL 도트 선량계의 교정인자, 흡수선량 선형성, 피크전압 선형성, 각도 변화에 의한 흡수선량 변화를 측정하고 분석했다. 의료용 X 선발생 장치를 사용하여 조사에 노출 선량 보정 계수, 흡수선량 선형성, 피크 전압 선형성은 모두 IEC-62387-1 (2007) 기준을 만족하였다. 기준 방사선 노출과 관련하여 0도, 30도 및 60도에서 선량계 방향에 대한 기준은 -29 % (${\pm}30^{\circ}$) 및 + 67 % (${\pm}60^{\circ}$)이었다. 30도에서 측정된 값은 기준보다 -8 % 낮고 60도에서 기준보다 -18 % 낮게 나타났다. 그러므로 OSL 도트 선량계 사용 시 방향에 따른 영향을 보정하여야 한다.

Analysis of a Spun-CNT Based X-ray Source

  • Kim, Hyun Suk;Castro, Edward Joseph D.;Hun, Choong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.639-639
    • /
    • 2013
  • In this research we report the significant contribution of the as-spun multi-walled carbon nanotube (MWCNT) on the x-ray images formation using a low tube voltage x-ray source. The MWCNT, which was used for the fabrication of the spun CNT, was grown using a microwave plasma-enhanced chemical vapor deposition machine. Electrical-optics simulation software was utilized to determine the electron field emission trajectory of the triode-structure-as-spun CNT-based x-ray source. It was shown that a significant amount of converging electrons hit the target anode producing a clear x-ray image. These x-ray images where produced at a small amount of anode current of 0.67 mA at a tube voltage of 5 kV with the gate voltage of 0 V. Also, comparisons of the radiographs at various exposure times of the sample where analyzed with and without an x-ray dose filter. Results showed that spatially-resolved images were formed using the as-spun CNT at a low tube voltage with a $54-{\mu}m$ Al x-ray filter. This study can be used for low-voltage medical applications.

  • PDF

인버터식 X선발생장치의 출력특성개선이 환자피폭선량 경감에 미치는 효과 (The Effect on Patient Dose Reduction with Improvement of the Output Characteristics for Inverter Type X-ray Generator)

  • 노모은;이성길;김영근
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.27-32
    • /
    • 2011
  • The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple. In this paper, the newly developed x-ray generator in a low cost using duty modulation PWM inverter. This system verify improved performance by stabilize ripple of X-ray tube voltage and compared the reproducibility, linearity and dose in single phase, three phase and PSU.

  • PDF

X선촬영에서 보호앞치마를 투과한 1차 선량의 SID별 변화 (A Study of Changes in the Primary Dose Penetrating the Protective Apron on SID in X-ray Radiography)

  • 최성관
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.501-507
    • /
    • 2016
  • 본 연구는 손, 머리, 허리측방향 등에 대한 X선 촬영조건(kVp, mAs)으로 SID 50cm, 1m, 2m에서 발생되는 1차 X선이 보호앞치마를 어느 정도 투과하는지를 알아보았고, 그 결과는 다음과 같다. 첫째, 손 X선 촬영조건의 1차X선은 0.3mmPb 보호앞치마로 차폐할 경우 선량을 약 270배 줄일 수 있으나 SID 50cm, 1m, 2m에서 보호앞치마를 각각 0.120, 0.043, 0.012mR 수준으로 투과한다. 둘째, 머리 X선 촬영조건의 1차X선은 0.3mmPb 보호앞치마로 차폐할 경우 선량을 약 22배 줄일 수 있으나 SID 50cm, 1m, 2m에서 보호앞치마를 각각 13.191, 4.821, 1.388mR 수준으로 투과한다. 셋째, 허리측방향 X선 촬영조건의 1차X선은 0.3mmPb 보호앞치마로 차폐할 경우 선량을 약 13배 줄일 수 있으나 SID 50cm, 1m, 2m에서 보호앞치마를 각각 77.844, 27.406, 8.606mR 수준으로 투과한다. 따라서 X선 검사 시 촬영실 내에 있는 관계자들은 1차X선이 도달하는 모든 공간에서 보호앞치마만을 착용한 채 머물러 있어서는 안 되며, 부득이하게 촬영실 안에 머물러 있어야 할 경우 보호앞치마 착용과 함께 두꺼운 납이 내장된 차폐칸막이 뒤에 안전하게 피해야 한다.