• Title/Summary/Keyword: low damage system

Search Result 577, Processing Time 0.036 seconds

A evaluation study of a fire smoke diffusion delay device installed in a great depth underground double deck tunnel (대심도 복층터널에 설치 가능한 화재연기 확산지연장치 성능 평가 연구)

  • Shin, Tae-Gyun;Moon, Jung-Joo;Yang, Yong-Won;Lee, Yun-Taek
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.225-234
    • /
    • 2018
  • Domestic urban areas are experiencing serious traffic congestion problems due to continuous population growth and increased traffic volume. In order to solve the problem of traffic congestion, the study of great depth underground double deck tunnels using underground space is being actively carried out in the urban areas. The characteristics of great depth underground double deck tunnels are low in cross section, so the spread of fire smoke is expected to spread faster than the road tunnel in case of fire. Therefore, it is necessary to provide a fire smoke delay device which delays the spread of fire smoke when a fire occurs in a tunnels. In the previous study, the diffusion effect was analyzed according to the blocking area when the fire smoke spread delay device was operated through the 3D CFD in the study of preventing the smoke spread in the case of the tunnel fire. A study on fire smoke diffusion delay device using spring elasticity which is excellent in applicability to a tunnel and economical value is studied. In this study, fire smoke spread delay system was developed to fire smoke delay was experimentally analyzed. Fire smoke delay effect of fire smoke delay device appeared. Therefore, it is considered that the can minimize the damage of the victims when installed in the great depth underground double deck tunnels.

Effect of Packaging Methods on Postharvest Quality of $Tah$ $Tasai$ Chinese Cabbage ($Brassica$ $campestris$ var. $narinosa$) Baby Leaf Vegetable (어린잎 채소 다채의 포장방법이 품질에 미치는 영향)

  • Lee, Jung-Soo;Lee, Youn-Suk
    • Food Science and Preservation
    • /
    • v.19 no.1
    • /
    • pp.1-6
    • /
    • 2012
  • The effect of the packing methods for enhancing the shelf life and improving the postharvest quality of the $tah$ $tasai$ Chinese cabbage baby leaf vegetable was studied during storage. Fresh baby leaf vegetables were packed in four commercial packaging types: (1) a non-perforated bag with a 0.03-mm oriented polypropylene (OPP) film; (2) a perforated bag with 1.0-mm-diameter holes on an OPP film; (3) a 0.40-mm polyethylene terephthalate (PET) container with a hinged lid; and (4) an expanded polystyrene (EPS) tray wrapped with a 0.02-mm polyvinyl chloride (PVC) film. The quality parameters, such as the weight loss, moisture content change, color difference, and appearance of the baby leaf vegetables were investigated. The baby leaf vegetables in the PET container and in the non-perforated OPP film bag showed relatively low weight loss, high moisture content, and good external appearance compared to those in the EPS tray and in the perforated OPP film bag during limited storage periods, at $16^{\circ}C$. The PET container also protected the baby leaf vegetables from physical damage. The study results will enable the selection of a better packaging system for extending the freshness and increasing the market ability of baby leaf vegetables.

Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests (풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석)

  • Lee, Dooyoung;Goo, Jaeryang;Park, Sooman;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.79-88
    • /
    • 2017
  • In this paper, the wind tunnel test for the measurement of aerodynamic characteristics of transmission conductors with asymmetric sections is described. A single conductor model and bundled conductor models with ice accreted shapes are tested both in steady and turbulent flow, and the aerodynamic coefficients are acquired. Transmission conductor galloping is a kind of wind-induced vibration which is characterized by primarily vertical oscillation with a very low frequency and a high amplitude. It is well known that transmission conductor galloping is generally caused by moderately strong, steady winds when a transmission conductor has an asymmetric cross-section shaped by accreted ice. Galloping should be considered from the design stage of overhead lines because it can cause severe wear and fatigue damage to attachments as well as transmission conductors. It is reported that there have been normally 20 events of galloping per year in Korea, which may be followed by serious consequences in the electric power system. Therefore, this research is performed to measure aerodynamic characteristics of ice accreted transmission conductors to understand and control transmission conductor galloping so that it would help to prevent unexpected failures and reduce the maintenance costs caused by galloping.

Effects of Special Protection Area Designation on Soil Properties and Vegetation Coverage of Degraded Trails (국립공원 특별보호구 지정이 훼손 탐방로 주변 토양과 식생피도에 미치는 영향)

  • Kim, Dong-Hwan;Lee, Dong-Ho;Kim, Hyun Seok;Kim, Seong-il
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.3
    • /
    • pp.352-359
    • /
    • 2015
  • This study was conducted to evaluate how the special protection area designations of degraded trails effect on the soil and vegetation recovery of degraded trails. The study areas were established on an opened trail and a 16-year closed trail, which was prohibited to enter after the designation as a special protection area for recovery, at Bukhansan National Park. Soil core sampling and measurements of vegetation cover were performed to compare soil and vegetation properties of the trails. Soil bulk density increased and soil water total nitrogen decreased on the opened trail, while no significant differences were found on bulk density, soil water, total nitrogen, acidity, and organic matter on the closed trail. On the opened trail, vegetation cover was seemed to be degraded, because vegetation litter cover ratio was low and barren rock cover ratio was high. On the closed trail, litter rock barren cover ratio of the closed trail was recovered, but only limited recovery was found on vegetation cover by applying environmental damage condition rating class. In conclusion, the closed trail was recovered by designation of special protection area, while difference in recovery progress of soil and vegetation was found. Therefore, designation of special protection area of degraded area should be based on scientific basis of recovery characteristics of the area. In order to improve the effectiveness of special protection area system, further specific standards for special protection area designation and management would be needed, considering ecological and social importance of target areas.

Experimental Study of Retrograde Cerebral Perfusion During Hypothermic Circulatory Arrest (초저체온 순환정지시 역행성 뇌혈 관류의 실험적 연구)

  • 김치경
    • Journal of Chest Surgery
    • /
    • v.26 no.7
    • /
    • pp.513-520
    • /
    • 1993
  • Surgical treatment of aneurysm or dissection involving the ascending aorta and aortic arch still poses one of the most complicated technical and tactical challenges in surgery. The use of total circulatory arrest[TCA] with profound hypothermia in the surgical treatment of aneurysmal dissection involving the ascending aorta and aortic arch has been reported as popular surgical methods. However, the safe period of prolonged circulatory arrest with hypothermia remains controversial and ischemic damage to the central nervous system and uncontrollable perioperative bleeding have been the major problem. We have found profound hypothermic circulatory arrest with retrograde cerebral perfusion via the superior vena cava to achieve cerebral protection. We experiment the aortic anastomosis in 7 adult mongrel dogs, using profound hypothermic circulatory arrest with continuous retrograde cerebral perfusion[RGCP] via superior vena cava. We also studied the extent of cerebral protection using above surgical methods, by gas analysis of retrograde cerebral perfusion blood and returned blood of aortic arch, preoperative, intraoperative and postoperative electroencephalography and microscopic findings of brain tissue. The results were as follows: 1. The cooling time ranged from 15 minutes to 24 minutes[19.71$\pm$ 3.20 minutes] ; Aorta cross clamp time ranged from 70 minutes to 89 minutes[79.86 $\pm$ 7.54 minutes] ; Rewarming time ranged from 35 minutes to 47 minutes[42.86$\pm$ 4.30 minutes] ; The extracorporeal circulation time ranged from 118 minutes to 140 minutes[128.43$\pm$ 8.98 minutes] [Table 2]. 2. The oxygen content in the oxygenated blood after RGCP was 12.66$\pm$ 1.25 ml/dl. At 5 minutes after the initiation of RGCP, the oxygen content of returnedlood was 7.58$\pm$ 0.21 ml/dl, and at 15 minutes 7.35$\pm$ 0.17 ml/dl, at 30 minutes 7.20$\pm$ 0.19 ml/dl, at 60 minutes 6.63$\pm$ 0.14 ml/dl [Table 3]. 3. Intraoperative electroencephalographic finding revealed low amplitude potential during hypothermia, and no electrical impulse throughout the period of circulatory arrest and RGCP. Electrical activity appeared after reperfusion, and the electroencephalographic reading also recovered rapidly as body temperature returned to normal [Fig. 2]. 4. The microscopic finding of brain tissue showed widening of the interfibrillar spaces. But there was no evidence of tissue necrosis or hemorrhage [Fig. 3]. We concluded the retrograde cerebral perfusion during hypothermic circulatory arrest is a simplified technique that may have a excellent brain protection.

  • PDF

Plasma Potential of Atmospheric Plasma Double Jets (대기압 플라즈마 이중 제트의 플라즈마 전위)

  • Kang, Han-Lim;Kim, Jung-Hyun;Kim, Hyun-Chul;Han, Sang-Ho;Cho, Gunagsup
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.312-321
    • /
    • 2012
  • The electric potential of plasma column is measured with the high voltage probe in a pair of atmospheric plasma jets operated by AC-voltage. According to the polarity of voltage applied to the electrodes, the polarity of plasma column potential has the same polarity of applied voltage. The high potential of plasma column at the side of high voltage electrode is decreased linearly along the plasma column to the ground side. Therefore, the plasma column seams to be a kind of resistor whose resistivity is a few 10s $M{\Omega}/m$. In the experiment of double-jets system, the polarity of plasma potential is verified to be the same polarity to the applied voltage. When the different voltage polarities are applied to the electrodes of double plasma jets, the attractive force is acted between two plumes at the merged plasma and the plasma potential is measured to be low as a few 10s V. When the same polarity of voltage is applied to the electrode, the repulsive force is acted and the plasma potential is measured to be high as a several 100s V at the merged plumes. In the exposure of plasma plume on the bio-substrate with the double plasma jets, the electric shock and thermal damage might be proportional to the plasma power which is the multiplication of the plasma potential and the plasma current.

Dual-frequency Capacitively Coupled Plasma-enhanced Chemical Vapor Deposition System for Solar Cell Manufacturing

  • Gwon, Hyeong-Cheol;Won, Im-Hui;Sin, Hyeon-Guk;Rehman, Aman-Ur;Lee, Jae-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.310-311
    • /
    • 2011
  • Dual-frequency (DF) capacitively coupled plasmas (CCP) are used to separately control the mean ion energy and flux at the electrodes [1]. This separate control in capacitively coupled radio frequency discharges is one of the most important issues for various applications of plasma processing. For instance, in the Plasma Enhanced Chemical Vapor Deposition processes such as used for solar cell manufacturing, this separate control is most relevant. It principally allows to increase the ion flux for high deposition rates, while the mean ion energy is kept constant at low values to prevent highly energetic ion bombardment of the substrate to avoid unwanted damage of the surface structure. DF CCP can be analyzed in a fashion similar to single-frequency (SF) driven with effective parameters [2]. It means that DF CCP can be converted into SF CCP with effective parameters such as effective frequency and effective current density. In this study, comparison of DF CCP and its converted effective SF CCP is carried out through particle-in-cell/Monte Carlo (PIC-MCC) simulations. The PIC-MCC simulation shows that DF CCP and its converted effective SF CCP have almost the same plasma characteristics. In DF CCP, the negative resistance arises from the competition of the effective current and the effective frequency [2]. As the high-frequency current increases, the square of the effective frequency increases more than the effective current does. As a result, the effective voltage decreases with the effective current and it leads to an increase of the ion flux and a decrease of the mean ion energy. Because of that, the negative resistance regime can be called the preferable regime for solar cell manufacturing. In this preferable regime, comparison of DF (13.56+100 or 200 MHz) CCP and SF (60 MHz) CCP with the same effective current density is carried out. At the lower effective current density (or at the lower plasma density), the mean ion energy of SF CCP is lower than that of DF CCP. At the higher effective current density (or at the higher plasma density), however, the mean ion energy is lower than that of SF CCP. In this case, using DF CCP is better than SF CCP for solar cell manufacturing processes.

  • PDF

Acute Type V Acromioclavicular Injury Treated by the Modified Bosworth Technique (급성 제 5형 견봉쇄골관절 탈구의 치료)

  • Kim Seung-Key;Yi Sang-Hoon;Park Jong Beom;Bahk, Won-Jong;Jang Il-Seok;Chang Han
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.126-132
    • /
    • 1999
  • Purpose : To evaluate the functional and radiographic outcome of the modified Bosworth method in the surgical treatment of acute type V acromioclavicular joint dislocation. Materials and Methods: From June 1995 to May 1998, 20 patients were operated on for acute and complete acromioclavicular dislocation(Rockwood type V). The operative technique includes fixation of the coracoclavicular joint with Bosworth screw or 6.5mm cancellous screw and imbrication of trapezius and deltoid muscles. The average age was 34 years(range, 19 to 51 years). These 20 patients with an average follow-up of 18months, were evaluated clinically using the UCLA scoring system. Additional radiographical assessment was performed with stress radiographs. Results: Excellent or good clinical results were obtained in 95%(19 cases). And the average coracoclavicular interval ratio was decreased from 3.31(2.2-6.0) to 1.13(1-1.4) in stress radiographs. There were 4 cases of hetero­topic calcification postoperatively but there was no correlation with clinical result. Posttraumatic A-C joint arthritis was developed in one case. In that case, the distal clavicular resection was done under the arthroscopic technique. Conclusion: The severe displacement observed with type V injuries is incompatible with normal shoulder function if the shoulder is left in its displaced position. In type V injuries, significant damage to the deltoid and trapezius musculature and overlying fascia occurs, therefore open reduction and good fixation must be obtained with imbrication of trapezius and deltoid muscles. In our type V acute complete acromioclavicular dislocation, the modified Bosworth technique provides excellent results with a low complication rate.

  • PDF

The Controlling Activity of Several Fungicides against Rice Bakanae Disease Caused by Fusarium fujikuroi in Five Assay Methods (몇 가지 살균제의 벼 키다리병과 병원균에 대한 효과 검정)

  • Shin, Myeong-Uk;Lee, Su-Min;Lee, Yong-Hwan;Kang, Hyo-Jung;Kim, Heung-Tae
    • The Korean Journal of Pesticide Science
    • /
    • v.12 no.2
    • /
    • pp.168-176
    • /
    • 2008
  • Recently damage of rice bakanae disease disseminated by infected seeds increased in paddy field in Korea. For controlling rice bakanae disease, the efficacy of 17 fungicides was assessed by 5 kinds of bioassay, spore germination test (SGT), mycelial growth test, detection test on Komada's medium (KDT), pouch test (PT) and greenhouse test (GT). Among ergosterol biosynthesis inhibiting fungicides, prochloraz showed a high controlling activity in all the assay systems while the others showed very low activity except for $500\;{\mu}g/ml$ of hexaconazole in GT and $500\;{\mu}g/ml$ of triflumizole in KDT. Although benomyl and the mixture of benomyl and thiram showed a good activity at 100 and $500\;{\mu}g/ml$ in SGT and PT, respectively, in GT they did a middle activity. Trifloxystrobin and kresoxim-methyl included in strobilurins showed a good activity even at $20\;{\mu}g/ml$ in KDT as well as a middle activity in SGT. Also a high activity not only at $10\;{\mu}g/ml$ in SGT but also at $100\;{\mu}g/ml$ KDT was detected in thiram. The activity of fludioxonil was confirmed in SGT, KDT and PT. Based on these results, it is very important to determine a bioassay system, because the fungicidal activity against rice bakanae disease was fluctuated depending on a assay systems as well as the mechanism of fungicide.

Immuno-chromatographic Analysis for HPV-16 and 18 E7 Proteins as a Biomarker of Cervical Cancer Caused by Human Papillomavirus

  • Kim, Joo-Ho;Cho, Il-Hoon;Seo, Sung-Min;Kim, Ji-Sook;Oh, Kyu-Ha;Kang, Heun-Soo;Kim, In-Gyu;Paek, Se-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.2999-3005
    • /
    • 2009
  • Among the more than 120 different types of human papillomavirus (HPV), types 16 and 18 have been known to be high risk agents that cause cervical cancer. We examined, in an immuno-chromatographic analysis, the potential of using the early gene product, E7 protein, as a diagnostic marker of cervical cancer caused by HPV. We developed monoclonal antibodies specific to HPV-16 and 18 E7 proteins that were produced from bacterial cells using gene recombinant technology. For each E7 protein, the optimal antibody pair was selected using the immuno-chromatographic sandwichtype binding system based on the lateral flow through membrane pores. Under these conditions, this rapid testing assay had a detection capability as low as 2 ng/mL of E7 protein. Furthermore, since viral analysis required the host cell to be lysed using chemicals such as detergents, it was possible that the E7 protein was structurally damaged during this process, which would result in a decrease in detection sensitivity. Therefore, we examined the detrimental effects caused by different detergents on the E7 protein using HeLa cells as the host. In these experiments, we found that the damage caused by the detergent, nonylphenylpolyethylene glycol (NP-40), was minimal relative to Triton X-100 commonly used for the cell lysis. Temperature also affected the stability of the E7 protein, and we found that the E7 protein was stabilized at 4$^{\circ}C$ for about 2 h, which was 4 times longer than at room temperature. Finally, a HPV-infected cervical cancer cell line, which was used as a real sample model, was treated using the optimized conditions and the presence of E7 proteins were analyzed by immuno-chromatography. The results of this experiment demonstrated that this rapid test could specifically detect HPV-infected samples.