• Title/Summary/Keyword: low damage system

Search Result 577, Processing Time 0.025 seconds

Seismic behavior of steel reinforced concrete (SRC) T-shaped column-beam planar and 3D hybrid joints under cyclic loads

  • Chen, Zongping;Xu, Jinjun;Chen, Yuliang;Xue, Jianyang
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.555-572
    • /
    • 2015
  • This paper presents an experimental study of three two-dimensional (2D/planar) steel reinforced concrete (SRC) T-shaped column-RC beam hybrid joints and six 3D SRC T-shaped column-steel beam hybrid joints under low cyclic reversed loads. Considering different categories of steel configuration types in column cross section and horizontal loading angles for the specimens were selected, and a reliable structural testing system for the spatial loading was employed in the tests. The load-displacement curves, carrying capacity, energy dissipation capacity, ductility and deformation characteristics of the test subassemblies were analyzed. Especially, the seismic performance discrepancies between planar hybrid joints and 3D hybrid joints were intensively compared. The failure modes for planar loading and spatial loading observed in the tests showed that the shear-diagonal compressive failure was the dominating failure mode for all the specimens. In addition, the 3D hybrid joints illustrated plumper hysteretic loops for the columns configured with solid-web steel, but a little more pinched hysteretic loops for the columns configured with T-shaped steel or channel-shaped steel, better energy dissipation capacity & ductility, and larger interlayer deformation capacity than those of the planar hybrid joints. Furthermore, it was revealed that the hysteretic loops for the specimens under $45^{\circ}$ loading angle are generally plumper than those for the specimens under $30^{\circ}$ loading angle. Finally, the effects of steel configuration type and loading angle on the seismic damage for the specimens were analyzed by means of the Park-Ang model.

A study on the high transparent and antistatic thin films on sodalime glass by reactive pulsed DC magnetron sputtering (Pulsed DC 마그네트론 스퍼터링으로 제조한 소다라임 유리의 고투과 및 대전방지 박막특성 연구)

  • Jung, Jong-Gook;Lim, Sil-Mook
    • Journal of Surface Science and Engineering
    • /
    • v.55 no.6
    • /
    • pp.353-362
    • /
    • 2022
  • Recently, transmittance of photomasks for ultra-violet (UV) region is getting more important, as the light source wavelength of an exposure process is shortened due to the demand for technologies about high integration and miniaturization of devices. Meanwhile, such problems can occur as damages or the reduction of yield of photomask as electrostatic damage (ESD) occurs in the weak parts due to the accumulation of static electricity and the electric charge on chromium metal layers which are light shielding layers, caused by the repeated contacts and the peeling off between the photomask and the substrate during the exposure process. Accordingly, there have been studies to improve transmittance and antistatic performance through various functional coatings on the photomask surface. In the present study, we manufactured antireflection films of Nb2O5, | SiO2 structure and antistatic films of ITO designed on 100 × 100 × 3 mmt sodalime glass by DC magnetron sputtering system so that photomask can maintain high transmittance at I-line (365 nm). ITO thin film deposited using In/Sn (10 wt.%) on sodalime glass was optimized to be 10 nm-thick, 3.0 × 103 𝛺/☐ sheet resistance, and about 80% transmittance, which was relatively low transmittance because of the absorption properties of ITO thin film. High average transmittance of 91.45% was obtained from a double side antireflection and antistatic thin films structure of Nb2O5 64 nm | SiO2 41 nm | sodalime glass | ITO 10 nm | Nb2O5 64 nm | SiO2 41 nm.

Ductility demands of steel frames equipped with self-centring fuses under near-fault earthquake motions considering multiple yielding stages

  • Lu Deng;Min Zhu;Michael C.H. Yam;Ke Ke;Zhongfa Zhou;Zhonghua Liu
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.589-605
    • /
    • 2023
  • This paper investigates the ductility demands of steel frames equipped with self-centring fuses under near-fault earthquake motions considering multiple yielding stages. The study is commenced by verifying a trilinear self-centring hysteretic model accounting for multiple yielding stages of steel frames equipped with self-centring fuses. Then, the seismic response of single-degree-of-freedom (SDOF) systems following the validated trilinear self-centring hysteretic law is examined by a parametric study using a near-fault earthquake ground motion database composed of 200 earthquake records as input excitations. Based on a statistical investigation of more than fifty-two (52) million inelastic spectral analyses, the effect of the post-yield stiffness ratios, energy dissipation coefficient and yielding displacement ratio on the mean ductility demand of the system is examined in detail. The analysis results indicate that the increase of post-yield stiffness ratios, energy dissipation coefficient and yielding displacement ratio reduces the ductility demands of the self-centring oscillators responding in multiple yielding stages. A set of empirical expressions for quantifying the ductility demands of trilinear self-centring hysteretic oscillators are developed using nonlinear regression analysis of the analysis result database. The proposed regression model may offer a practical tool for designers to estimate the ductility demand of a low-to-medium rise self-centring steel frame equipped with self-centring fuses progressing in the ultimate stage under near-fault earthquake motions in design and evaluation.

A study on cleaning performance of particles on collection plates using an electrodynamic screen (전기역학적 스크린을 이용한 집진판 표면 위 입자 세정성능 연구)

  • Yunhui Joe;Dongho Shin;Younghun Kim;Inyong Park;Sang Bok Kim;Gunhee Lee;Bangwoo Han
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.63-76
    • /
    • 2023
  • An electrostatic precipitator (ESP) has a low pressure drop and a high collection efficiency but its collection efficiency can be reduced due to dust accumulation on the collection plates during long-term operations. In order to maintain the initial dust collection efficiency, it is necessary to periodically clean the collection plates. The common cleaning methods are using physical impacts or water sprays. These cleaning methods can lead to damage to the collection plate or generate wastewater. Herein, we implemented an electrodynamic screen (EDS) for ESP cleaning and evaluated its surface cleaning performance of particles. The EDS is an electrostatic system that can electrostatically repel particles on surfaces, allowing it to clean the ESP without causing damage and wastewater generation. Our evaluation included the analysis of the effects of AC voltage characteristics, electrode configuration and environmental conditions on the cleaning performance of the EDS with the aim of achieving effective surface cleaning. It has been demonstrated that activating the EDS cleans up to 65% of the particles on the surface, which indicates about 94% of our target cleaning zone.

Chattering Reduction of Variable Structure Controller for Position System of Induction Motor (유도전동기의 위치제어 시스템을 위한 가변구조제어기의 떨림저감)

  • Kim, Young-Jo;Kim, Hyun-Jung
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.2
    • /
    • pp.39-47
    • /
    • 1998
  • It has been known that variable structure control(VSC) has theoretically powerful control technique of providing fast response, no overshoot, and very robust control with respect to system parameter variations and disturbances. However, the technique has not become more widely extended in the industrial circles because chattering phenomenon which may excite high-frequency unmodelled plant dynamics and damage to system components exists. In this paper, a modified variable structure control(MVSC) is developed to alleviate these problems which are applied to the position control of induction motor. While the conventional VSC makes the structure of the system change with high-frequency switching on the center of the one switching surface, in the MVSC two switching surface are used to establish a sliding sector. The structure of the system will be changed with low-frequency switching. Therefore, the proposed algorithm has the properties of reducing chattering, retaining the benefits achieved in the conventional VSC, and working even under the influences of parameter variations. Experimental results show the effectiveness of the control strategy proposed here for the position control of induction motor.

  • PDF

Evaluation of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance (내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 저항성 평가)

  • Won, Jong-Pil;Choi, Seok-Won;Park, Chan-Gi;Park, Hae-Kyun
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.559-568
    • /
    • 2006
  • The purpose of this study is to evaluate the mechanical performance and fire resistance of wet-mixed high strength sprayed polymer-modified mortar in order to protect tunnel lining system which are in the event of fire disaster. Since the current commercial fire-resistant materials reproduce the low strength issue of mortar, this study aims to provide an enhanced fire-resistant mortar with a proper strength. Normally, a large temperature gradient phenomenon arise in the vicinity of free surfaces which are fully exposed in the event of persistent flame. Thereby, the determination of optimal cover depth of wet-mixed high strength sprayed polymer-mortar(WHSPM) is important for fire-resistance of tunnel lining system. With comparison of current commercial fire-resistance materials and WHSPM, the experimental result of WHSPM shows the better fire-resistant performance than the others. In addition, the cover limitation should be controlled by minimum 4cm depth in order to avoid fire-induced damage.

Application of Sprinkler System for Control of Cone Insects on Korean Pine, Pinus koraiensis Seed Orchard (스프링클러시스템을 이용한 잣나무 채종원의 구과해충 방제에 관한 연구)

  • Song Byong-Min;Kwon Gun-Hyung;Chung Sang-Bae
    • Korean Journal of Plant Resources
    • /
    • v.19 no.1
    • /
    • pp.93-96
    • /
    • 2006
  • In order to prevent cones from being damaged by cone insects, Gravitarmata margarotana and Dioryctria abietella, sprinkler system was installed on the Pinus koraiensis Seed Orchard. Such a test was conducted at Chung-ju, Chungcheong buk-do, Korea in 2002. Insectides of Diflubenzuron 25% WP ${\times}2,500$ and Cyfluthrin 2%EC ${\times}\;1,000$ were sprayed at fifteen-day and twenty-day intervals during the period of insects adult occurrence by sprinkler system. The Gravitarmata margarotana generally emerged for about 53 days from middle April to early June, and peak emergence was 10 days from April 20 to April 30. Dioryctria abietella generally emerged for about 108 days from late April to early August, and peak emergence was 10 days from May 20 to May 30. Damage rate of cones were $8.7{\sim}9.7%$ and $10.9{\sim}12.7%$ on average with crown insecticide spraying with Cyfluthrin and Diflubenzuron, while 67.5% when not treated. Control effectiveness of this insecticide spraying was $85.6{\sim}87.1%$ and 83.9%와 81.2%, respectively. When it considers the forest environment, it is recommended diflubenzuron which is low toxic pesticide. In conclusion, effectual times and number of diflubenzuron 25% WP application with sprinkler system against cone insects were from early May through late August and six times at twenty-day interval.

Functional Characterization of the C-Terminus of YhaV in the Escherichia coli PrlF-YhaV Toxin-Antitoxin System

  • Choi, Wonho;Yoon, Min-Ho;Park, Jung-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.6
    • /
    • pp.987-996
    • /
    • 2018
  • Bacterial programmed cell death is regulated by the toxin-antitoxin (TA) system. YhaV (toxin) and Pr1F (antitoxin) have been recently identified as a type II TA system in Escherichia coli. YhaV homologs have conserved active residues within the C-terminus, and to characterize the function of this region, we purified native YhaV protein (without denaturing) and constructed YhaV proteins of varying lengths. Here, we report a new low-temperature method of purifying native YhaV, which is notable given the existing challenges of purifying this highly toxic protein. The secondary structures and thermostability of the purified native protein were characterized and no significant structural destruction was observed, suggesting that the observed inhibition of cell growth in vivo was not the result of structural protein damage. However, it has been reported that excessive levels of protein expression may result in protein misfolding and changes in cell growth and mRNA stability. To exclude this possibility, we used an [$^{35}S$]-methionine prokaryotic cell-free protein synthesis system in vitro in the presence of purified YhaV, and two C-terminal truncated forms of this protein (YhaV-L and YhaV-S). Our results suggest that the YhaV C-terminal region is essential for mRNA interferase activity, and the W143 or H154 residues may play an analogous role to Y87 of RelE.

Extraction of Lineament and Its Relationship with Fault Activation in the Gaeum Fault System (가음단층계의 선형구조 추출과 선형구조와 단층활동의 관련성)

  • Oh, Jeong-Sik
    • Journal of The Geomorphological Association of Korea
    • /
    • v.26 no.2
    • /
    • pp.69-84
    • /
    • 2019
  • The purpose of this study is to extract lineaments in the southeastern part of the Gaeum Fault System, and to understand their characteristics and a relationship between them and fault activation. The lineaments were extracted using a multi-layered analysis based on a digital elevation model (5 m resolution), aerial photos, and satellite images. First-grade lineaments inferred as an high-activity along them were classified based on the displacement of the Quaternary deposits and the distribution of fault-related landforms. The results of classifying the first-grade lineaments were verified by fieldwork and electrical resistivity survey. In the study area of 510 km2, a total of 222 lineaments was identified, and their total length was 333.4 km. Six grade lineaments were identified, and their total length was 11.2 km. The lineaments showed high-density distribution in the region along the Geumcheon, Gaeum, Ubo fault, and a boundary of the Hwasan cauldron consisting the Gaeum Fault System. They generally have WNW-ESE trend, which is the same direction with the strike of Gaeum Fault System. Electrical resistivity survey was conducted on eight survey lines crossing the first-grade lineament. A low-resistivity zone, which is assumed to be a fault damage zone, has been identified across almost all survey lines (except for only one survey line). The visual (naked eyes) detecting of the lineament was evaluated to be less objectivity than the automatic extraction using the algorithm. However, the results of electrical resistivity survey showed that first-grade lineament extracted by visual detecting was 83% reliable for inferred fault detection. These results showed that objective visual detection results can be derived from multi-layered analysis based on tectonic geomorphology.

A Study on Deriving Key Management Factors for the Prevention of COVID-19 in Construction Sites (건설현장 코로나 바이러스 예방을 위한 중점관리요소 도출에 관한 연구)

  • Shin, Eun Kyoung;Eom, Yong Been;Kim, Dae Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.91-102
    • /
    • 2022
  • Many industries are being severely damaged by COVID-19, a respiratory infection that has recently been prevalent around the world. In particular, for workers in the construction industry, it is impossible to work from home, and if an outbreak on a construction site is confirmed, it can lead to great damage. Accordingly, the government has drafted 「Guidelines for Response to Construction Sites for Prevention and Spread of COVID-19」. In addition, domestic and foreign research about COVID-19 in the field of construction sites is being actively conducted. However, Korea has lacked studies on the effectiveness of the countermeasures in place at construction sites, or that reflect the opinions of construction site workers. Therefore, this study conducted a survey of construction site workers by dividing the construction of the COVID-19 quarantine management system and response plan into on-site management and social management. Through the AHP/IPA analysis, it was found that among social management, 'infectious disease management system and cooperation system with related institutions' and 'reduction of working hours' are areas with high importance but low satisfaction. After that, the causes of the two items were analyzed and related countermeasures were suggested. The results of this study will be able to contribute to the improvement of the quarantine management system and response plan at construction sites, and to minimize the damage to the construction industry related to COVID-19.