Implementation of Simple Controller Board for the Servo System (서보 시스템을 위한 간단한 제어기 보드의 구현)

  • Choi, Kwang-Soon;Lee, Yong-Gu;Eom, Ki-Hwan;Son, Dong-Seol
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.738-741
    • /
    • 1995
  • This disseration realized the simple digital controller board using ${\mu}$-PD 70320 microprocessor has characteristics that are low cost, simple hardware organization, convenient and interchangeable with the 8086 for the servo system. We gave the control algorithm such as PD control. Self tuning adaptive control and Fuzzy control to the realized controller board and made a new real number data type for a high accuracy control. Users can select of suitable for the control algorithim. In the result of simulation and experiment shown a good performance.

  • PDF

Implementation of the 3 axes Attitude Control Sensor System (3축 자세 제어용 센서 시스템의 구현)

  • Jeong, Jong-Won;Choi, Woo-Jin;Ji, Suk-Jun;Lee, Ki-Young;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2329-2331
    • /
    • 2001
  • In this paper, were developed the 3 axes attitude control sensor system to control and monitoring the moving object. The proposed sensor system has been studied in Japan, America for a year ago. But it is high expensive and has a difficulty in application. To overcome these problems, proposed the 3 axes attitude control sensor system is low cost and easily applied. Proposed sensor system is equipped with the 3 gyro sensors, 2 tilt sensors and 3 MR sensors using 80C51 microprocessor for signal processing. It's output value transmit at long distance using RS232 serial communication protocol. We expect this system shall have a good performances in many applications of control and monitoring the moving object.

  • PDF

A Low Cost Drive System of Switched Reluctance Motor Using Reflective Type Photosensors (반사형 광센서를 사용한 저가형 SRM 구동시스템)

  • Kim, Se-Joo;Yoon, Yong-Ho;Jung, Gyun-Ha;Won, Chung-Yuen;Kim, Young-Real
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.63-68
    • /
    • 2004
  • Since rotor position information is necessary to drive the SRM, absolute-encoder, resolver and incremental-encoder is used to detect a poor position. But, it is not desirable to use a high priced encoder and high efficient microprocessor under the condition of the simple driving system when precision control is not demanded. In this paper, Only using the reflective type 2 photosensors replace the conventional opto interrupter and slotted disk, which not only remove a slotted disk section but drive 3-phase 6/4 SRM bidirectionally. Moreover, as control circuit only is composed of common analog device economy is maximized.

  • PDF

Novel Encoder for Independent Switching Angle Control of SRM (SRM제어를 위한 스위칭 각 독립제어형 엔코더)

  • Lee, Ju-Hyun;Hwang, Hyung-Jin;Oh, Seok-Gyu;An, Jin-Woo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.511-513
    • /
    • 2004
  • In a switched reluctance motor drive, it is important to synchronize the stator phase excitation with the rotor position, because the position of rotor is an essential information. In the high-speed region, switching angles are fluctuated back and forth out of the preset value, which is caused by the sampling period of the microprocessor. In this paper, a low cost analog encoder suitable for practical applications is proposed. The validity of the proposed analog encoder with a proper logic controller is verified from the experiments.

  • PDF

A Stable A/D Conversion of Load Cell Signal by Single Chip Microprocessor (싱글칩 마이크로프로세서에 의한 로드셀 신호의 A/D 변환 안정화 처리)

  • Park, C.W.;An, K.H.;Choi, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.450-452
    • /
    • 1993
  • In this study, a method is suggested to design the A/D conversion system which has high resolution to convert load cell signal. First, hardware was designed to reduce the offset voltage of integrator and comparator. And then, a calibration software technique was performed to obtain the stable data from A/D converter. The optimal parameters of each elements in the circuits was selected using the SPICE simulation. The main advantage of our method is high precision A/D converter can be constructed with low cost and high confidence. Therefore proposed method is expected to be used in the industrial field where a high precision measurement is required.

  • PDF

A study on MPPT control using the balace/unbalance control (평형/불평형 제어를 이용한 MPPT제어에 과한 연구)

  • K., T.K.;K., G.H.;C., K.J.;P., J.W.;Matsui, M.;L., H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.334-336
    • /
    • 2005
  • This paper proposes a simple MPPT control scheme of a Current- Control-Loop Error system Based that can be obtains a lot of advantage to compare with another digital control method, P&O and IncCond algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. But, a proposed method is easy to solve the cost reduction and power unbalance problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment on battery charger using PIC that is the microprocessor of a low price.

  • PDF

A Study about Modeling and Control of Dynamic Absorber for Vehicle by Using Active Viscous Damping (능동적 점성감쇠를 이용한 차량용 동적 흡진기의 모델링과 제어에 관한 연구)

  • 김대원;배준영
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.121-130
    • /
    • 1999
  • Generally, A Dynamic Absorber by using Active viscous Damping is highlighted for effective suspension system, such as improved ride comfort and handling in the market. Lately, this system based on the Sky-Hook damper theory is introduced by the name of "Active Dynamic Absorber" to us. This system has an excellent performance in contrast to Passive. Adaptive Dynamic Absorber, besides having low cost components of system, low energy consumption. light weight of system. In this viewpoint. most of car-maker will adopt this system in the near future. For this reason, we developed Dynamic Absorber by using Active viscous Damping which is equipped with continuously variable Dynamic Absorber and Control logic consisting Filter and Estimator. control apparatus of Dynamic Absorber operated by 16-bit microprocessor of high performance. variable device of viscous Damping. G-sensor so on. In this paper. several important points of development procedure for realizing this system will be described with results in which is obtained from experiment by simulation and Full car test in Proving ground. respectively.pectively.

  • PDF

Design and Implementation of Real-Time Vehicle Safety System based on Wireless Sensor Networks (무선 센서 네트워크 기반의 실시간 차량 안전 시스템 설계 및 구현)

  • Hong, YouSik;Oh, Sei-JIn;Kim, Cheonshik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.2
    • /
    • pp.57-65
    • /
    • 2008
  • Wireless sensor networks achieve environment monitoring and controlling through use of small devices of low cost and low power. Such network is comprised of several sensor nodes, each having a microprocessor, sensor, actuator and wired/wireless transceiver inside a small device. In this paper, we employ the sensor networks in order to design and implement a real-time vehicle safety system. Such system can inform the safe velocity in a specific weather condition to drivers in advance through analyzing the weather data collected from sensor networks. As a result, the drivers can prevent effectively accidents by controlling their car speed.

  • PDF

A Study on MPPT Control using the Maximum Power Balance/Unbalance Boundary Point Control (최대 전력 평형/불평형 경계점 제어를 이용한 MPPT제어에 관한 연구)

  • Koh Kang-Hoon;Kang Tae-Kyeng;Lee Hyun-Woo;Woo Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.33-38
    • /
    • 2006
  • This paper proposes a simple MPPT control scheme of a based Current-Control-Loop system that can be obtains a lot of advantage to compare with another digital control method, P&O(Perturbation and Observation) and IncCond(Incremental Conductance) algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. Therefore, it is applied a small home power generation system that required many expenses. But, a proposed method is easy to solve the cost reduction and power unbalance Problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment results on battery charger using PIC that is the microprocessor of a low price.

Design of a Current Transducer and Over-Current Fault Detection Circuit for Power Strip Applications (멀티 콘센트용 변류기 및 과전류 검출 회로 설계)

  • Kim, Yong-Jae;Kim, Min-Seok;Park, Gyu-Sang;Kim, Jae-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.8
    • /
    • pp.921-926
    • /
    • 2015
  • For the over-heat protection purpose in power strip devices, over-current detection/protection circuits, such as bimetal, switching circuit, and microprocessor-based relay circuit, have been widely setup in high-end products. Most of these circuits are connected to the power line in parallel and, thus, they are sensitive to the line voltage and current distortion. Moreover, these protection circuits are often costly and, therefore, it is hard to meet the commercial requirements. A low-cost over-current detection circuit with the contactless current transducer is designed and tested in this paper. The detection circuit is galvanically isolated from the power line and, thus, less sensitive to the line voltage distortion. The experimental results show that the proposed circuit accurately operates despite of its simple structure and low-cost electronic parts.