• Title/Summary/Keyword: low cost method

Search Result 2,854, Processing Time 0.04 seconds

A study on the correlation between V charpy absorbed energy and critical COD value in the welded parts of high tensil strength steel under various welding methods (고장력강 용접부에 있어서 한계 COD값과 V charpy충격치와의 상관성에 관한 연구)

  • 김영식;김충해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.57-67
    • /
    • 1988
  • Although handicapped by the inability to bridge the size gap between small laboratory sample and large engineering component, the V charpy test sample method does possess certain advantages, such as each of preparation, simplicity of test method, speed, low cost in test machinery, and low cost per test. On the other hand, the COD test method does posses advantages, which reduce the size gap between the laboratory sample and actual engineering component. Consequently, the correlation between V charpy absorbed energy and the critical COD value is required for estimating critical COD value from the simple V charpy test results. In this paper, the high tensile strength steel AH36 plate specimens having a single edge cracked notch were investigated to find out the correlation between V charpy absorbed energy and critical COD value in the welded parts under such various welding methods as shielded metal arc welding, the submerged arc welding and the electro gas welding by means of V charpy impact test and static 3-point bending test. Main results obtained are as follow ; 1. The relationships between V charpy absorbed energy Wc' and critical COD value ($\delta_c$)show; $\delta_c$=0.0065 Wc'+0.1906. 2. Ductile- brittle transition behaviours can be estimated by means of fracture appearance and general yielding behaviours. 3. The V charpy absorbed energy of SMAW is higher than that of SAW, EGW and similar relationships are obtained in the COD tests.

  • PDF

The Monitoring System Using Multi Antenna GPS for Weak Slope (Multi Antenna GPS를 이용한 취약사면 상시모니터링 시스템)

  • Noh, Won-Seok;Kim, Wan-Jong;Jang, Hyun-Ick;Kim, Hak-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.677-694
    • /
    • 2009
  • While the budget has been allocated more for repairs and reinforcements, casualties are gradually increased due to slope disaster. Slope disaster causes road damaged as well as casualties. It also causes significant social and economic loss. The measurement device, which is installed inside ground of slope like inclinometer, has the high loss rate when slope is being slided. The electric type and the vibrating wire type have low durability because of corrosion. To cover the demerit of the present slope monitoring, the measurement method using the Multi-Antenna GPS has been developed. The Multi-Antenna GPS has been installed in the local slope as the regular monitoring system for slope. Although the initial cost of the Multi-Antenna GPS for installation is high, the additional cost is low. So it is the suitable method for large slope. The regular monitoring system using the Multi-Antenna GPS is the suitable measurement method for watching slope collapse, which is occurred widely, because it is economical, has high durability, and collects data with high resolution.

  • PDF

Validation of Reduced-volume Reaction in the PowerQuant® System for human DNA Quantification

  • Kim, Hyojeong;Cho, Yoonjung;Kim, Jeongyong;Lee, Ja Hyun;Kim, Hyo Sook;Kim, Eungsoo
    • Biomedical Science Letters
    • /
    • v.26 no.4
    • /
    • pp.275-287
    • /
    • 2020
  • Since its introduction in the forensic field, quantitative PCR (qPCR) has played an essential role in DNA analysis. Quality of DNA should be evaluated before short tandem repeat (STR) profiling to obtain reliable results and reduce unnecessary costs. To this end, various human DNA quantification kits have been developed. Among these kits, the PowerQunat® System was designed not only to determine the total amount of human DNA and human male DNA from a forensic evidence item, but also to offer data about degradation of DNA samples. However, a crucial limitation of the PowerQunat® System is its high cost. Therefore, to minimize the cost of DNA quantification, we evaluated kit performance using a reduced volume of reagents (1/2-volume) using DNA samples of varying types and concentrations. Our results demonstrated that the low-volume method has almost comparable performance to the manufacturer's method for human DNA quantification, human male DNA quantification, and DNA degradation index. Furthermore, using a reduced volume of regents, it is possible to run 2 times more reactions per kit. We expect the proposed low-volume method to cut costs in half for laboratories dealing with large numbers of DNA samples.

Development of a Cost-Effective Process for the Fabrication of Single Grain $YBa_2Cu_3O_{7-y}$ Bulk Superconductors (단결정 $YBa_2Cu_3O_{7-y}$ 벌크 초전도체 제조를 위한 경제적 공정의 개발)

  • Park, Soon-Dong;Kim, Kwang-Mo;Jun, Byung-Hyuk;Han, Young-Hee;Kim, Chan-Joong
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.133-138
    • /
    • 2011
  • To reduce the processing cost of the single grain REBCO (RE: Rare-earth elements) bulk superconductors, a cost-effective process should be developed. One possible way of developing the cost-effective process is the use of low-cost precursor powders. In this study, the single grain YBCO superconductors were fabricated using a home made powder. $YBa_2Cu_3O_{7-y}$ (Y123) powders were synthesized at $850-900^{\circ}C$ in air by the powder calcination method with repeated crushing and heat treatment steps. The processing parameters for the fabrication of single grain Y123 bulk superconductors, $T_{max}$ (maximum temperature), $T_p$ (peritectic temperature) and a cooling rate through $T_p$ were optimized. To enhance the flux pinning capacity of the single grain Y123 samples, $Y_2BaCuO_5$ (Y211) particles were dispersed in the Y123 matrix by adding $Y_2O_3$ powder to the calcined Y123 powder. Applying the optimized processing condition, the single grain Y123 superconductors with $T_c=91\;K$ and $J_c=1.5{\times}10^4\;A/cm^2$ at 2 T were successfully fabricated using a home made powder. The levitation forces and trapped magnetic field at 77 K measured using a Nd-B-Fe permanent magnet of 5300 G were 47 N and 3000 G, respectively, which are comparable to those obtained for the samples fabricated using a commercial grade Y123 powders.

Efficient Evaluation Method of Operation Cost for Wastewater Treatment Plant by BTL Contract Type (하수처리시설 BTL사업의 합리적인 운영비 산정방안)

  • Kang, Leen Seok;Yoon, Sun MI;Kwon, Joong Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5D
    • /
    • pp.627-634
    • /
    • 2009
  • The BTL (Build-Transfer-Lease) contract of construction project serves as a part for early establishment of industrial foundation for social overhead capital. However, project cost of BTL contract is focused on initial construction cost. Accordingly, operation cost is lowly evaluated because there is no standard criterion for estimating maintenance cost for the facility. The low operation cost can be a factor that reduces service quality of facility operation. This study suggests a resonable method for estimating cost and manpower in the operation phase by using the existing practical data for wastewater treatment plant by BTL contract. The results of the study can be used for evaluating rough operation cost and manpower of similar plant project by facility size.

The method for manufacturing a aluminum solid electrolytic capacitor using a conducting polymer (전도성 고분자를 이용한 알루미늄 고체 전해 커패시터의 제조방법)

  • Shin, Dal-Woo;Kim, Sung-Ho;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.61-64
    • /
    • 2001
  • This study relates to a method for manufacturing a solid electrolytic capacitor using a functional polymer composition. The method comprises immersing the rolled aluminum electrolytic capacitor device in polyaniline solution with high electric conductivity to impregnate the device with polyaniline, drying the impregnated device in a drying oven which is maintained at constant temperature to fully remove the solvent, inserting the dried device to a capacitor aluminum can and then sealing with epoxy resin, to manufacture a solid electrolytic capacitor using a conducting polymer. As such, the impregnation can be performed well at not only normal temperature and pressure, but also high temperature and reduced pressure. The solid electrolytic capacitor has the advantages of high capacity, low impedance and low ESR, and also, low manufacturing cost, simple processes and high reliability.

  • PDF

The method for manufacturing a aluminum solid electrolytic capacitor using a conducting polymer (전도성 고분자를 이용한 알루미늄 고체 전해 커패시터의 제조방법)

  • 신달우;김성호;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.61-64
    • /
    • 2001
  • This study relates to a method for manufacturing a solid electrolytic capacitor using a functional polymer composition. The method comprises immersing the rolled aluminum electrolytic capacitor device in polyaniline solution with high electric conductivity to impregnate the device with polyaniline, drying the impregnated device in a drying oven which is maintained at constant temperature to fully remove the solvent, inserting the dried device to a capacitor aluminum can and then sealing with epoxy resin, to manufacture a solid electrolytic capacitor using a conducting polymer. As such, the impregnation can be performed well at not only normal temperature and pressure, but also high temperature and reduced pressure. The solid electrolytic capacitor has the advantages of high capacity, low impedance and low ESR, and also, low manufacturing cost, simple processes and high reliability.

  • PDF

Speed and Position Estimation Method for PMSM with Low-Resolution Hall-Effect Sensors (저 분해능 홀센서를 이용한 영구자석 동기 전동기의 속도 및 위치 추정기법)

  • Ahn, H.J.;Lee, D.M.
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.114-115
    • /
    • 2014
  • This paper proposes a new speed and position estimation method for PMSM(Permanent Magnet Synchronous Motor) using low-resolution hall-effect sensors. In general, there are a variety of sensors to estimate rotor position for PMSM such as resolvers, and encoders. Position detection using hall-effect sensors that detect the flux of the rotor for rotor position is excellent method in terms of cost and space, but has low-resolution. To overcome this problem, this paper proposes a new speed and position estimation observer. The performance of the observer has been verified by simulations carried out using Matlab/Simulink.

  • PDF

Low Work Function and Sharp Field Emitter Arrays by Transfer Mold Fabrication Method

  • Nakamoto, Masayuki;Sato, Genta;Shiratori, Kohji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.1049-1052
    • /
    • 2007
  • Extremely sharp and uniform Transfer Mold FEAs with thin film low work function TiN emitter material have been fabricated by controlling the thickness of the coated emitter materials to realize high efficient, high reliable and low-cost vacuum nanoelectronic devices..Their tip radii are 8.3-13.8 nm. Turn-on electric fields of the Ni FEAs and TiN-FEAs resulted in the low electric field values of $31.6\;V/{\mu}m$ and $44.2V/{\mu}m$,respectively, at the short emitter/anode distance: less than $30\;{\mu}m$, which are lower than those of conventional FE As such as Spindt type FEAs and carbon nan otube FEAs The Transfer Metal Mold fabrication method is one of the best methods of changing emit ter materials with sharp and uniform emit ter shapes.

  • PDF

Implementation of the laser scanning using the step motor (스텝모터를 활용한 정밀 스케닝 구현에 관한 고찰)

  • Chun, Sam-Suk;Park, Chan-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.967-968
    • /
    • 2007
  • This report is the study for laser scanning. Scanning control of $CO_2$ laser, He-Ne laser, used for the treatment of body skin, has relatively low band about hundered Hz. It could be used as a substitiute for expensive galvanometer that is the established scan method, which operates the number of KHz movement by using step motor when it operates low speed. To increase the accuracy of step motor's the angle of rotation, We could materialize 100Hz low band by using open loop, closed loop method with microprocessor. This causes it to be stable even direction by attaching electric capacity sensor. Therefore, We could expect to reduce the cost by manufacturing low band scanner rather than costly feedback galvanometer.

  • PDF