• Title/Summary/Keyword: low contrast resolution

검색결과 137건 처리시간 0.027초

Application of a newly developed software program for image quality assessment in cone-beam computed tomography

  • de Oliveira, Marcus Vinicius Linhares;Santos, Antonio Carvalho;Paulo, Graciano;Campos, Paulo Sergio Flores;Santos, Joana
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.75-86
    • /
    • 2017
  • Purpose: The purpose of this study was to apply a newly developed free software program, at low cost and with minimal time, to evaluate the quality of dental and maxillofacial cone-beam computed tomography (CBCT) images. Materials and Methods: A polymethyl methacrylate (PMMA) phantom, CQP-IFBA, was scanned in 3 CBCT units with 7 protocols. A macro program was developed, using the free software ImageJ, to automatically evaluate the image quality parameters. The image quality evaluation was based on 8 parameters: uniformity, the signal-to-noise ratio (SNR), noise, the contrast-to-noise ratio (CNR), spatial resolution, the artifact index, geometric accuracy, and low-contrast resolution. Results: The image uniformity and noise depended on the protocol that was applied. Regarding the CNR, high-density structures were more sensitive to the effect of scanning parameters. There were no significant differences between SNR and CNR in centered and peripheral objects. The geometric accuracy assessment showed that all the distance measurements were lower than the real values. Low-contrast resolution was influenced by the scanning parameters, and the 1-mm rod present in the phantom was not depicted in any of the 3 CBCT units. Smaller voxel sizes presented higher spatial resolution. There were no significant differences among the protocols regarding artifact presence. Conclusion: This software package provided a fast, low-cost, and feasible method for the evaluation of image quality parameters in CBCT.

A building roof detection method using snake model in high resolution satellite imagery

  • Ye Chul-Soo;Lee Sun-Gu;Kim Yongseung;Paik Hongyul
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.241-244
    • /
    • 2005
  • Many building detection methods mainly rely on line segments extracted from aerial or satellite imagery. Building detection methods based on line segments, however, are difficult to succeed in high resolution satellite imagery such as IKONOS imagery, for most buildings in IKONOS imagery have small size of roofs with low contrast between roof and background. In this paper, we propose an efficient method to extract line segments and group them at the same time. First, edge preserving filtering is applied to the imagery to remove the noise. Second, we segment the imagery by watershed method, which collects the pixels with similar intensities to obtain homogeneous region. The boundaries of homogeneous region are not completely coincident with roof boundaries due to low contrast in the vicinity of the roof boundaries. Finally, to resolve this problem, we set up snake model with segmented region boundaries as initial snake's positions. We used a greedy algorithm to fit a snake to roof boundary. Experimental results show our method can obtain more .correct roof boundary with small size and low contrast from IKONOS imagery. Snake algorithm, building roof detection, watershed segmentation, edge-preserving filtering

  • PDF

Gender Classification of Low-Resolution Facial Image Based on Pixel Classifier Boosting

  • Ban, Kyu-Dae;Kim, Jaehong;Yoon, Hosub
    • ETRI Journal
    • /
    • 제38권2호
    • /
    • pp.347-355
    • /
    • 2016
  • In face examinations, gender classification (GC) is one of several fundamental tasks. Recent literature on GC primarily utilizes datasets containing high-resolution images of faces captured in uncontrolled real-world settings. In contrast, there have been few efforts that focus on utilizing low-resolution images of faces in GC. We propose a GC method based on a pixel classifier boosting with modified census transform features. Experiments are conducted using large datasets, such as Labeled Faces in the Wild and The Images of Groups, and standard protocols of GC communities. Experimental results show that, despite using low-resolution facial images that have a 15-pixel inter-ocular distance, the proposed method records a higher classification rate compared to current state-of-the-art GC algorithms.

시각 감지 기반의 저조도 영상 이미지 적응 보상 증진 알고리즘 (Adaptive Enhancement of Low-light Video Images Algorithm Based on Visual Perception)

  • 이원;민병원
    • 사물인터넷융복합논문지
    • /
    • 제10권2호
    • /
    • pp.51-60
    • /
    • 2024
  • 저조도 환경에서 영상 이미지의 콘트라스트가 낮고 식별이 어려운 문제를 목표로 사람의 시각 감지 기반의 콘트라스트 적응 보상 증진 알고리즘을 제안한다. 첫째, 저조도 환경에서 평균 밝기, 평균 대역폭 요인의 영상 이미지 특징 요인을 추출하고, 원본 영상의 회색/색도 차이에 따라 사람의 시각적 콘트라스트 해상도 보상의 수학적 모델을 설정하며, 실제 컬러의 3원색에 대해 각각 비례 적분하여 보상한다. 다음으로 보상 정도가 명시각 차이를 적절하게 구별할 수 있는 것보다 낮을 때 보상 임계값 선형 보상이 명시각에서 전체 대역폭으로 설정된다. 마지막으로 주관적인 이미지 품질 평가와 이미지 특성 요인을 결합하여 비례 계수를 보상하는 자동 최적화 모델을 구축한다. 실험 테스트 결과는 영상 이미지 적응 증진 알고리즘이 우수한 증진 효과와 우수한 실시간 성능을 가지며 다크 비전 정보를 효과적으로 마이닝할 수 있으며 다양한 시나리오에서 널리 사용될 수 있음을 보여준다.

Breast Ultrasound Microvascular Imaging and Radiogenomics

  • Ah Young Park;Bo Kyoung Seo;Mi-Ryung Han
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.677-687
    • /
    • 2021
  • Microvascular ultrasound (US) techniques are advanced Doppler techniques that provide high sensitivity and spatial resolution for detailed visualization of low-flow vessels. Microvascular US imaging can be applied to breast lesion evaluation with or without US contrast agents. Microvascular US imaging without a contrast agent uses a sophisticated wall filtering system to selectively obtain low-flow Doppler signals from overlapped artifacts. Microvascular US imaging with second-generation contrast agents amplifies flow signals and makes them last longer, which facilitates hemodynamic evaluation of breast lesions. In this review article, we will introduce various microvascular US techniques, explain their clinical applications in breast cancer diagnosis and radiologic-histopathologic correlation, and provide a summary of a recent radiogenomic study using microvascular US.

4차원 TRICKS 자기공명혈관조영술과 기존 TOF 자기공명혈관조영술의 비교 및 유용성 (The Value of Comparison with Four Dimension Time Resolved Imaging of Contrast Kinetics(TRICKS) MRA by Time of Flight(TOF) MRA)

  • 배성진;임청환;박병래;신운재;김정삼
    • 한국콘텐츠학회논문지
    • /
    • 제10권3호
    • /
    • pp.215-221
    • /
    • 2010
  • Time Resolved Imaging of Contrast Kinetics 기법을 이용한 4차원 자기공명혈관조영술 (TRICKS-MRA)영상과 기존 TOF-MRA영상을 비교하여 임상적 유용성에 대해 알아보고자 하였다. 총17명 중 뇌혈관 질환이 의심되는 11명과 뇌종양을 의심하는 6명을 대상으로 TOF-MRA와 TRICKS-MRA을 시행한 후 17 대상자 중 11명에서 DSA를 추가적으로 시행하였다. TOF-MRA는 공간해상력보다 시간해상력이 부족하였고, TRICKS-MRA에서는 TOF-MRA보다 공간분해능은 부족한 점이 많지만 영상판독에 큰 영향은 없었고 모든 대상자에서 동맥과 정맥의 구별이 가능하여 시간분해능이 우수한 것을 나타났다. 또한 종양과 혈관과의 관계성 평가에서 TOF-MRA보다 좋은 것으로 나타났다. TRICKS-MRA방법은 시간대별로 동맥, 모세혈관, 정맥기를 신속하면서 쉽게 4차원적으로 영상화가 가능하여 앞으로 임상에서 이용도가 더욱 증가 할 것으로 사료된다.

4차원 영상기법 Time Resolved Imaging of Contrast Kinetics MRA의 유용성 (Four Dimension(4D) Time Resolved Imaging of Contrast Kinetics(TRICKS) MR Angiography)

  • 임청환;배성진
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1105-1110
    • /
    • 2009
  • Time Resolved Imaging of Contrast Kinetics 기법을 이용한 4차원 자기공명혈관조영술(TRICKS -MRA)영상과 기존 TOF-MRA영상을 비교하여 임상적 유용성에 대해 알아보고자 하였다. 총 17명 중 뇌 혈관 질환이 의심되는 11명과 뇌 종양을 의심하는 6명을 대상으로 TOF-MRA와 TRICKS -MRA을 시행한 후 17대상자 중 11명에서 DSA를 추가적으로 시행하였다. TOF-MRA는 공간해상력보다 시간해상력이 부족하였고, TRICKS-MRA에서는 TOF-MRA보다 공간분해능은 부족한 점이 많지만 영상판독에 큰 영향은 없었고 모든 대상자에서 동맥과 정맥의 구별이 가능하여 시간분해능이 우수 한 것을 나타났다. 또한 종양과 혈관과의 관계성 평가에서 TOF-MRA보다 좋은 것으로 나타났다. TRICKS-MRA방법은 시간대별로 동맥, 모세혈관, 정맥기를 신속하면서 쉽게 4차원적으로 영상화가 가능하여 앞으로 임상에서 이용도가 더욱 증가 할 것으로 사료된다.

  • PDF

고분해능 전자현미경법을 이용한 (Bi, La)4Ti3O12 박막의 결정학적 특성 평가 (Crystallographic Characterization of the (Bi, La)4Ti3O12 Film by High-Resolution Electron Microscopy)

  • 이덕원;양준모;박태수;김남경;염승진;박주철;이순영;박성욱
    • 한국재료학회지
    • /
    • 제13권7호
    • /
    • pp.478-483
    • /
    • 2003
  • The crystallographic characteristics of the $(Bi, La)_4$$Ti_3$$O_{12}$ thin film, which is considered as an applicable dielectrics in the ferroelectric RAM device due to a low crystallization temperature and a good fatigue property, were investigated at the atomic scale by high resolution transmission electron microscopy and the high resolution Z-contrast technique. The analysis showed that a (00c) preferred orientation and a crystallization of the film were enhanced with the diffraction intensity increase of the (006) and (008) plane as the annealing temperature increased. It indicated a change of the atomic arrangement in the (00c) plane. Stacking faults on the (00c) plane were also observed. Through the comparison of the high-resolution Z-contrast image and the $Bi_4$$Ti_3$$O_{12}$ atomic model, it was evaluated that the intensity of the Bi atom was different according to the atomic plane, and it was attributed to a substitution of La atom for Bi at the specific atom position.

Design of an Image Processor for UXGA Class LCD

  • Cho, Hwa-Hyun;Choi, Myung-Ryul
    • Journal of Information Display
    • /
    • 제2권2호
    • /
    • pp.13-21
    • /
    • 2001
  • We propose a universal image processor for a-Si TFT LCD of UXGA class that can display the full screen on the LCD panel with low resolution of video sources such as NTSC, VGA, SVGA, XGA, and SXGA by using the proposed interpolation filter. In addition, we propose a real-time contrast controller for image improvement of multi-gray scale image. The operation of the proposed methods has been verified using Synopsys VHDL and computer simulation. Results show that the proposed methods might be suitable for a UXGA LCD controller for real-time image improvement.

  • PDF

저선량에서의 TrueX 재구성 방법에 의한 유용성 평가 (The Evaluation of TrueX Reconstruction Method in Low Dose)

  • 오세문;김계환;김승정;이홍재;김진의
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.83-87
    • /
    • 2011
  • 최근 진단분야에서 PET/CT는 종양학 분야뿐만 아니라 심장 신경 등 여러 가지 분야에서 널리 활용되고 있다. PET/CT의 중요성이 높아지면서 영상의 질과 관련된 재구성 방법에 대한 연구도 활발히 진행되고 있다. 이 중 Siemens사의 TrueX 재구성 방법을 phantom 실험을 통해 Iterative 2D 재구성 방법과 비교 평가하여 임상적 유용성을 높이고자 하였다. 선량에 따른 영상을 비교 평가하기 위해 contrast ratio와 FWHM을 측정하였고 Biograph 40 True Point PET/CT (Siemens, Germany)를 사용하여 실험을 실시하였다. Contrast ratio를 구하기 위해 NEMA IEC PET body phantom (Data Spectrum Corp.)을 이용하였고, FWHM을 측정하기 위해 capillary tube를 사용하였다. 모든 영상은 10분씩 획득하였고, 영상 재구성은 현재 사용하고 있는 TrueX와 기존에 사용하던 Itertive 2D 알고리즘을 사용하였다. Iterative 2D는 임상에 적합한 parameter 조건을 적용하고 TrueX는 Siemens에서 권고하는 parameter를 적용하여 실험하였다. Capillary tube를 사용하여 FWHM을 측정한 결과, TrueX가 Iterative 2D 방식보다 낮게 나왔다. 저선량일수록 FWHM의 차이가 점점 커졌다. NEMA IEC PET body phantom을 사용하여 contrast ratio를 구한 결과, TrueX가 Itertive 2D보다 좋은 양상을 보였다. 그러나 선량에 따른 차이는 보이지 않았다. 본 연구에서는 영상 분석을 통해 TrueX가 Itertive 2D보다 contrast ratio와 spatial resolution이 높게 나타났다. 또한 TrueX를 통한 재구성 결과 저선량일수록 기존의 Iterative 2D보다 resolution은 좋은 양상을 보였고 contrast ratio는 큰 변화를 보이지 않았다. 즉 PET/CT에서 TrueX 재구성 기법이 환자의 피폭도 절감하고 질적으로 우수한 영상을 구현할 수 있어 임상적 이용가치가 높다고 생각된다.

  • PDF