• Title/Summary/Keyword: low PSA

Search Result 121, Processing Time 0.037 seconds

Modified parity space averaging approaches for online cross-calibration of redundant sensors in nuclear reactors

  • Kassim, Moath;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.4
    • /
    • pp.589-598
    • /
    • 2018
  • To maintain safety and reliability of reactors, redundant sensors are usually used to measure critical variables and estimate their averaged time-dependency. Nonhealthy sensors can badly influence the estimation result of the process variable. Since online condition monitoring was introduced, the online cross-calibration method has been widely used to detect any anomaly of sensor readings among the redundant group. The cross-calibration method has four main averaging techniques: simple averaging, band averaging, weighted averaging, and parity space averaging (PSA). PSA is used to weigh redundant signals based on their error bounds and their band consistency. Using the consistency weighting factor (C), PSA assigns more weight to consistent signals that have shared bands, based on how many bands they share, and gives inconsistent signals of very low weight. In this article, three approaches are introduced for improving the PSA technique: the first is to add another consistency factor, so called trend consistency (TC), to include a consideration of the preserving of any characteristic edge that reflects the behavior of equipment/component measured by the process parameter; the second approach proposes replacing the error bound/accuracy based weighting factor ($W^a$) with a weighting factor based on the Euclidean distance ($W^d$), and the third approach proposes applying $W^d$, TC, and C, all together. Cold neutron source data sets of four redundant hydrogen pressure transmitters from a research reactor were used to perform the validation and verification. Results showed that the second and third modified approaches lead to reasonable improvement of the PSA technique. All approaches implemented in this study were similar in that they have the capability to (1) identify and isolate a drifted sensor that should undergo calibration, (2) identify a faulty sensor/s due to long and continuous missing data range, and (3) identify a healthy sensor.

Comparative Evaluation of the Analytical Methods used to Determine Pesticide Residues in Milk via Dispersive Solid Phase Extraction (Dispersive Solid Phase Extraction을 사용한 우유 내 잔류농약 다성분 동시 분석법 비교연구)

  • Oh, Nam Su;Shin, Yong Kook;Lee, Ji Young;Baick, Seung Chun
    • Journal of Dairy Science and Biotechnology
    • /
    • v.33 no.1
    • /
    • pp.27-34
    • /
    • 2015
  • The aim of this study was to optimize a simple, fast, and economic analytical method for the simultaneous determination of various pesticides (aldrin, p,p'-DDT, o,p'-DDT, p,p'-DDE, ${\alpha}$-endosulfan, ${\beta}$-endosulfan, dieldrin, heptachlor, permethrin, chlordane, deltamethrin, diazinon, bifenthrin, methoprene, propargite, fenpropathrin, cypermethrin, fenvalerate, and fenpropathrin) in milk by using dispersive solid phase extraction (SPE). In this study, two different extraction methods (low temperature cleanup and liquid-liquid partitioning), which were followed by a cleanup process based on dispersive-SPE, were evaluated and compared for the 19 pesticides. The results for all the pesticides were determined by gas chromatography mass spectrometry (GC/MS) with selected-ion monitoring mode, and the matrix effect of the method was evaluated. Comparison of these approaches yielded higher and more consistent recoveries of most pesticides at fortification levels of $1{\mu}g/mL$ using low-temperature fat precipitation, followed by cleanup process based on dispersive-SPE with PSA and C18 as sorbents, than other preparation process. The relative standard deviation was <20 % and the combination of this method were very effective for the cleanup.

  • PDF

A Study on Seismic Probabilistic Safety Assessment for a Research Reactor (연구용 원자로에 대한 지진 확률론적 안전성 평가 연구)

  • Oh, Jinho;Kwag, Shinyoung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.1
    • /
    • pp.31-38
    • /
    • 2018
  • Earthquake disasters that exceed the design criteria can pose significant threats to nuclear facilities. Seismic probabilistic safety assessment(PSA) is a probabilistic way to quantify such risks. Accordingly, seismic PSA has been applied to domestic and overseas nuclear power plants, and the safety of nuclear power plants was evaluated and prepared against earthquake hazards. However, there were few examples where seismic PSA was applied in case of a research reactor with a relatively small size compared to nuclear power plants. Therefore, in this study, seismic PSA technique was applied to actually completed research reactor to analyze its safety. Also, based on these results, the optimization study on the seismic capacity of the system constituting the research reactor was carried out. As a result, the possibility of damage to the core caused by the earthquake hazard was quantified in the research reactor and its safety was confirmed. The optimization study showed that the optimal seismic capacity distribution was obtained to ensure maximum safety at a low cost compared with the current design. These results, in the future, can expect to be used as a quantitative indicator to effectively improve the safety of the research reactor with respect to earthquakes.

Comparison of Physicochemical Properties of Starch Acetates Prepared by Conventional, Preheat Treatment and Extrusion Process (습식법과 예열처리법 및 Extrusion 공정에 의해 제조한 초산전분의 이화학적 성질비교)

  • Kim, Chong-Tai;Ryu, Gi-Hyung;Kim, Dong-Chul;Kim, Chul-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.659-667
    • /
    • 1990
  • Starch acetates were prepared by conventional method, preheat treatment, and extrusion process through acetylation of corn starch with acetic anhydride and their physicochemical properties were investigated. The optimal conditions of the acetylation of starch by conventional method(CSA) was found that starch concentration was 30%, reaction temperature $35^{\circ}C$ and pH 8.5. With increasing the molar ratio of acetic anhydride to anhydrous glucose unit from 0.03 to 0.20, DS(Degree of substitution) value of corn starch acetate prepared at the optimum condition was increased from 0.019 to 0.080, while the acetylation efficiency was decreased from 31.6% to 20.5%. In the case of the preheated (gelatinized), then acetylated starch(PSA), DS value was increased from 0.027 to 0.04 at the fixed molar ratio of the acetic anhydride with increasing preheating temperature from $60^{\circ}C\;to\;90^{\circ}C$. The DS was low as 0.02 in the case of starch acetate prepared by extrusion process(WESA). The CSA and PSA showed lowering gelatinization temperature and enthalpy than raw corn starch with increasing DS. All of starch acetates showed the increased degree of transparency, the decreased lightness and the increased yellowness as compared to the raw corn starch. WESA showed lower apparent viscosity and more close to the characteristic of the Newtonian fluid than CSA and PSA. Intrinsic viscosity was reduced in CSA and WESA, although PSA has a slightly higher one than raw corn starch. The rate of retrogradation of the gels was retarded in all starch acetates.

  • PDF

Noise Reduction Methods for the EMG Median Frequency Data in Fatiguing Isotonic Exercise (등장성 운동 시 근전도 중앙주파수 데이터의 잡음 제거 방법)

  • Cho, Sang-Hyun
    • Physical Therapy Korea
    • /
    • v.8 no.4
    • /
    • pp.31-43
    • /
    • 2001
  • 19명의 건강한 성인 남자의 우세팔쪽 위팔두갈래근에서 피로가 생길 때까지 2.4초를 하나의 주기로 팔꿉을 반복적 등장성으로 굽히고 펴서 표면근전도 신호를 얻었다. 처리과정 A 중앙주파수(MDF )는 이 신호의 0.5초 구간을 power spectrum analy sis (PSA)로 계산하였는데 상당량의 잡음이 있었다. 중앙주파수의 잡음 양을 비교하기 위해, 동일한 표면근전도에서 3번까지 신호를 받았다 (2.4초 구간을 PSA로 계산한 처리과정 B, 13 point 로 moving averages한 처리과정 C, digital low pass filter한 처리과정 D). 그리고 나서 그 신호의 주요 주파수 성분을 뽑아내었다. 위의 중앙주파수 자료와 시간간의 회귀직선을 분석하면 초기 중앙주파수, 회귀기울기, 그리고 피로지수와 같은 모수를 얻을 수 있다. 비모수 검정의 하나인 Kendall 기법으로 네 개의 처리과정간의 모수를 비교하였다. 통계결과 잡음이 처리과정 A보다 B, C, D에서 적었고, D에서 가장 적게 나타났다. 중앙주파수를 digital low pass로 여과(filtering)함으로써 앞으로 있게 될 동적 운동 시 근피로 모니터기의 신뢰도를 높일 수 있다.

  • PDF

A Study on the Variation of Rn-222 Concentration in Groundwater at Busan-Geumjeong area (부산 금정구지역의 지하수에 포함된 라돈농도 변화 연구)

  • Cho, Jungg-Sook;Lee, Hyo-Min;Kim, Sun-Woong;Kim, Jin-Seop
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.149-158
    • /
    • 2012
  • In this paper, we measured the variations of radon concentrations in groundwater using low-level Liquid Scintillation Counter (LSC), an instrument for analyzing the alpha and beta radionuclides at its 10 sites around the Kumjung-Gu, north-western of Busan. Optimization of Pulse Shape Analyzer (PSA) to determinate the highest value of figure of merit (FM) was decided using Quantulus 1200 LSC with radium-226 source, the optimal PSA level was shown in the range of 100 to 110. The results show that the Minimum Detectable Activity (MDA) of radon concentrations is 0.61 $Bq{\cdot}L^{-1}$ for 20 minutes in PSA level. We find that the average radon concentration in groundwater is high in granitic rock area and low in volcanic rock area. (Biotite granite : 191.39 $Bq{\cdot}L^{-1}$, Micro graphic granite : 141.88 $Bq{\cdot}L^{-1}$, Adamellite : 92.94 $Bq{\cdot}L^{-1}$, Andesite (volcanic) : 35.35 $Bq{\cdot}L^{-1}$). No significant seasonal variation pattern is observed from the long-term variation analysis from 10 selected sites. We have not seen the significant correlation of radon concentration to groundwater temperature, atmospheric temperature, atmospheric pressure and rainfall. The concentration variation is probably caused by more complex factors and processes.

Spatial spectrum approach for pilot spoofing attack detection in MIMO systems

  • Ning, Lina;Li, Bin;Wang, Xiang;Liu, Xiaoming;Zhao, Chenglin
    • ETRI Journal
    • /
    • v.43 no.5
    • /
    • pp.941-949
    • /
    • 2021
  • In this study, a spatial spectrum method is proposed to cope with the pilot spoofing attack (PSA) problem by exploiting the of uplink-downlink channel reciprocity in time-division-duplex multiple-input multiple-output systems. First, the spoofing attack in the uplink stage is detected by a threshold derived from the predefined false alarm based on the estimated spatial spectrum. When the PSA occurs, the transmitter (That is Alice) can detect either one or two spatial spectrum peaks. Then, the legitimate user (That is Bob) and Eve are recognized in the downlink stage via the channel reciprocity property based on the difference between the spatial spectra if PSA occurs. This way, the presence of Eve and the direction of arrival of Eve and Bob can be identified at the transmitter end. Because noise is suppressed by a spatial spectrum, the detection performance is reliable even for low signal-noise ratios and a short training length. Consequently, Bob can use beamforming to transmit secure information during the data transmission stage. Theoretical analysis and numerical simulations are performed to evaluate the performance of the proposed scheme compared with conventional methods.

Zeolites: Their Features as Pressure Swing Adsorbents and CO2 Adsorption Capacity (제올라이트: 압력순환형 흡착제로서의 특성과 CO2 흡착성능)

  • Kim, Moon-Hyeon;Cho, Il-Hum;Choi, Sang-Ok;Choo, Soo-Tae
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.943-962
    • /
    • 2014
  • Industrial gas drying, dilute gas mixtures purification, air fractionation, hydrogen production from steam reformers and petroleum refinery off-gases, etc are conducted by using adsorptive separation technology. The pressure swing adsorption (PSA) has certain advantages over the other methods, such as absorption and membrane, that are a low energy requirement and cost-effectiveness. A key component of PSA systems is adsorbents that should be highly selective to a gas being separated from its mixture streams and have isotherms suitable for the operation principle. The six standard types of isotherms have been examined in this review, and among them the best behavior in the adsorption of $CO_2$ as a function of pressure was proposed in aspects of maximizing a working capacity upon excursion between adsorption and desorption cycles. Zeolites and molecular sieves are historically typical adsorbents for such PSA applications in gas and related industries, and their physicochemical features, e.g., framework, channel structure, pore size, Si-to-Al ratio (SAR), and specific surface area, are strongly associated with the extent of $CO_2$ adsorption at given conditions and those points have been extensively described with literature data. A great body of data of $CO_2$ adsorption on the nanoporous zeolitic materials have been collected according to pressure ranges adsorbed, and these isotherms have been discussed to get an insight into a better $CO_2$ adsorbent for PSA processes.

Electronic Detection of Biomarkers by Si Field-Effect Transistor from Undiluted Sample Solutions with High Ionic Strengths

  • Ah, Chil-Seong;Kim, An-Soon;Kim, Wan-Joong;Park, Chan-Woo;Ahn, Chang-Geun;Yang, Jong-Heon;Baek, In-Bok;Kim, Tae-Youb;Sung, Gun-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1561-1567
    • /
    • 2010
  • In this study, we have developed a new detection method using Si field effect transistor (FET)-type biosensors, which enables the direct monitoring of antigen-antibody binding within very high-ionic-strength solutions such as 1$\times$PBS and human serum. In the new method, as no additional dilution or desalting processes are required, the FET-type biosensors can be more suitable for ultrasensitive and real-time analysis of raw sample solutions. The new detection scheme is based on the observation that the strength of antigen-antibody-specific binding is significantly influenced by the ionic strength of the reaction solutions. For a prostate specific antigen (PSA), in some conditions, the binding reaction between PSA and anti-PSA in a low-ionic strength reaction solution such as 10 ${\mu}M$ phosphate buffer is weak (reversible), while that in high-ionic strength reaction solutions such as 1$\times$PBS or human serum is strong.

Reduced graphene oxide field-effect transistor for biomolecule detection and study of sensing mechanism

  • Kim, D.J.;Sohn, I.Y.;Kim, D.I.;Yoon, O.J.;Yang, C.W.;Lee, N.E.;Park, J.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.431-431
    • /
    • 2011
  • Graphene, two dimensional sheet of sp2-hybridized carbon, has attracted an enormous amount of interest due to excellent electrical, chemical and mechanical properties for the application of transparent conducting films, clean energy devices, field-effect transistors, optoelectronic devices and chemical sensors. Especially, graphene is promising candidate to detect the gas molecules and biomolecules due to the large specific surface area and signal-to-noise ratios. Despite of importance to the disease diagnosis, there are a few reports to demonstrate the graphene- and rGO-FET for biological sensors and the sensing mechanism are not fully understood. Here we describe scalable and facile fabrication of rGO-FET with the capability of label-free, ultrasensitive electrical detection of a cancer biomarker, prostate specific antigen/${\alpha}1$-antichymotrypsin (PSA-ACT) complex, in which the ultrathin rGO sensing channel was simply formed by a uniform self-assembly of two-dimensional rGO nanosheets on aminated pattern generated by inkjet printing. Sensing characteristics of rGO-FET immunosensor showed the highly precise, reliable, and linear shift in the Dirac point with the analyte concentration of PSA-ACT complex and extremely low detection limit as low as 1 fg/ml. We further analyzed the charge doping mechanism, which is the change in the charge carrier in the rGO channel varying by the concentration of biomolecules. Amenability of solution-based scalable fabrication and extremely high performance may enable rGO-FET device as a versatile multiplexed diagnostic biosensor for disease biomarkers.

  • PDF