• 제목/요약/키워드: loss system

검색결과 7,482건 처리시간 0.037초

EVALUATION OF SPATIAL SOIL LOSS USING THE LAND USE INFORMATION OF QUICKBIRD SATELLITE IMAGERY

  • Lee, Mi-Seon;Park, Jong-Yoon;Jung, In-Kyun;Kim, Seong-Joon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.274-277
    • /
    • 2007
  • This study is to estimate the spatial distribution of soil loss using the land use data produced from QuickBird satellite imagery. For a small agricultural watershed (1.16 $km^2$) located in the upstream of Gyeongan-cheon watershed, a precise agricultural land use map were prepared using QuickBird satellite image of April 5 of 2003. RUSLE (Revised Universal Soil Loss Equation) was adopted for soil loss estimation. The data (DEM, soil and land use) for the RUSLE were prepared for 5 m and 30 m spatial resolution. The results were compared with each other and the result of 30 m Landsat land use data.

  • PDF

전달손실계수 측정 시스템에 대하여(Part II) (On the Transmission Loss Measurement System(Part II))

  • 김윤석;류윤선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.658-661
    • /
    • 2003
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the transmission loss coefficient measurement system using 4-microphone impedance tube is proposed, based on the idea calculating the full transfer matrix of the acoustical sample to test. The theoretical background and measurement system are introduced, and finally the measurement results are verified.

  • PDF

순환적 부분트리 탐색법을 이용한 중부하 배전계통의 손실최소화 (Loss Reduction in Heavy Loaded Distribution Networks Using Cyclic Sub Tree Search)

  • 최상열;신명철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권5호
    • /
    • pp.241-247
    • /
    • 2001
  • Network reconfiguration in distribution systems is realized by changing the status of sectionalizing switches, and is usually done for loss reduction of load balancing in the system. This paper presents an effective heuristic based switching scheme to solve the distribution feeder loss reduction problem. The proposed algorithm consists of two parts. One is to set up a decision tree to represent the various switching operations available. Another is to apply a proposed technique called cyclic best first search. the proposed algorithm identify the most effective the set of switch status configuration of distribution system for loss reduction. To demonstrate the validity of the proposed algorithm, numerical calculations are carried out the 32, 69 bus system models.

  • PDF

LoRa 모듈을 이용한 GPS기반 무선 분실 방지 시스템 구현 (Implementation of GPS-based Wireless Loss Prevention System using the LoRa Module)

  • 고준혁;한동균;이세라;박하연;김동회
    • 디지털콘텐츠학회 논문지
    • /
    • 제18권4호
    • /
    • pp.761-768
    • /
    • 2017
  • 블루투스 통신을 이용한 분실 방지기는 짧은 통신거리를 가지기 때문에 일정한 거리를 벗어나면 분실물의 위치를 알 수 없다는 단점을 가지고 있다. 기존 분실 방지기의 단점을 극복하기 위하여 본 논문에서는 상대적으로 긴 통신거리를 가지는 LoRa 통신과 위치 추적을 위한 통신료가 필요 없는 GPS 기반 무선 분실 방지 시스템을 제안한다. 제안하는 분실 방지기는 원격 제어 애플리케이션을 스마트 폰에서 실행하여 Lora 통신을 이용해 분실 방지기의 장거리 GPS 좌표 정보를 구글 지도상에서 확인할 수 있는 시스템이다. 구현된 제안시스템의 성능 평가를 위해 개활지, 실내, 실내-실외에서 데이터 송수신 실험을 진행하였고 실험 결과는 제안된 시스템이 장거리에서도 성능이 우수함을 확인하였다.

Application of Remotely Sensed Data and Geographic Information System in Watershed Management Planning in Imha, Korea

  • CHAE Hyo-Sok;LEE Geun-Sang;KIM Tae-Joon;KOH Deuk-Koo
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.361-364
    • /
    • 2005
  • The use of remotely sensed data and geographic information system (GIS) to develop conservation-oriented watershed management strategies on Imha Dam, Korea, is presented. The change of land use for study area was analyzed using multi-temporal Landsat imagery. A soil loss model was executed within a GIS environment to evaluate watershed management strategies in terms of soil loss. In general, remotely sensed data provide efficient means of generating the input data required for the soil loss model. Also, GIS allowed for easy assessment of the relative erosion hazard over the watershed under the different land use change options. The soil loss model predicted substantial declines in soil loss under conservation-oriented land management compared to current land management for Imha Dam. The results of this study indicate that soil loss potential (5,782,829 ton/yr) on Imha Dam in 2003 is approximately 1.27 times higher than that (4,557,151 ton/yr) in 1989. This study represents the first attempt in the application of GIS technology to watershed conservation planning for Imha Dam. The procedures developed will contribute to the evolution of a decision support system to guide the land planning and dam management in Imha Dam.

  • PDF

Tip Clearance Effect on Through-Flow and Performance of a Centrifugal Compressor

  • Eum, Hark-Jin;Kang, Young-Seok;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.979-989
    • /
    • 2004
  • Numerical simulations have been performed to investigate tip clearance effect on through-flow and performance of a centrifugal compressor which has the same configuration of impeller with six different tip clearances. Secondary flow and loss distribution have been surveyed to understand the flow mechanism due to the tip clearance. Tip leakage flow strongly interacts with mainstream flow and considerably changes the secondary flow and the loss distribution inside the impeller passage. A method has been described to quantitatively estimate the tip clearance effect on the performance drop and the efficiency drop. The tip clearance has caused specific work reduction and additional entropy generation. The former, which is called inviscid loss, is independent of any internal loss and the latter, which is called viscous loss, is dependent on every loss in the flow passage. Two components equally affected the performance drop as the tip clearances were small, while the efficiency drop was influenced by the viscous component alone. The additional entropy generation was modeled with all the kinetic energy of the tip leakage flow. Therefore, the present paper can provide how to quantitatively estimate the tip clearance effect on the performance and efficiency.

Experimental Estimation on Magnetic Friction of Superconductor Flywheel Energy Storage System

  • Lee, Jeong-Phil;Han, Sang-Chul;Park, Byeong-Choel
    • Journal of Magnetics
    • /
    • 제16권2호
    • /
    • pp.124-128
    • /
    • 2011
  • This study estimated experimentally the loss distribution caused by magnetic friction in magnetic parts of a superconductor flywheel energy storage system (SFES) to obtain information for the design of high efficiency SFES. Through the spin down experiment using the manufactured vertical shaft type SFES with a journal type superconductor magnetic bearing (SMB), the coefficients of friction by the SMB, the stator core of permanent magnet synchronous motor/generator (PMSM/G), and the leakage flux of the metal parts were calculated. The coefficients of friction by the stator core of PMSM/G in case of using Si-steel and an amorphous core were calculated. The energy loss by magnetic friction in the stator core of PMSM/G was much larger than that in the other parts. The level of friction loss could be reduced dramatically using an amorphous core. Energy loss by the leakage magnetic field was small. On the other hand, the energy loss could be increased under other conditions according to the type of metal nearby the leakage magnetic fields. In manufactured SFES, the rotational loss by the amorphous core was approximately 2 times the loss of the superconductor and leakage. Moreover, the rotational loss by the Si-steel core is approximately 3~3.5 times the loss of superconductor and leakage.

멀티레벨 인버터 시스템의 전도손실과 스위칭손실 해석 (The Analysis of Conduction and Switching Losses in Multi-Level Inverter System)

  • ;;李요한
    • 전력전자학회논문지
    • /
    • 제7권2호
    • /
    • pp.111-120
    • /
    • 2002
  • 멀티레벨 인버터 시스템은 낮은 고조파 성분과 높은 전력이 요구되는 분야에 매우 효율적인 시스템이다. 멀티레벨 인버터 시스템의 경우에 스위치 소자의 손실은 기존의 방법으로는 해석 할 수 없다. 그 이유는 각 스위치 소자의 손실이 2-레벨과는 다르게 서로 같지 않기 때문이다. 본 논문에서는 멀티레벨 인버터 시스템에 대한 전도 손실과 스위칭 손실의 간단하고 정확한 방법을 제안하였다. 제안된 방법의 타당함은 3-레벨과 4-레벨 다이오드 클램프드 인버터 시스템에 대해 증명하였다.

진동기반 구조식별을 통한 프리스트레스트 콘크리트 거더의 긴장력 손실 검색 기법 (Prestress-Loss Monitoring Technique for Prestressd Concrete Girders using Vibration-based System Identification)

  • 호득유이;홍동수;김정태
    • 한국해양공학회지
    • /
    • 제24권1호
    • /
    • pp.123-132
    • /
    • 2010
  • This paper presents a prestress-loss monitoring technique for prestressed concrete (PSC) girder structures that uses a vibration-based system identification method. First, the theoretical backgrounds of the prestress-loss monitoring technique and the system identification technique are presented. Second, vibration tests are performed on a lab-scaled PSC girder for which the modal parameter was measured for several prestress-force cases. A numerical modal analysis is performed by using an initial finite element (FE) model from the geometric, material, and boundary conditions of the lab-scaled PSC girder. Third, a vibration-based system identification is performed to update the FE model by identifying structural parameters since the natural frequency of the FE model became identical to the experimental results. Finally, the feasibility of the prestress-loss monitoring technique is evaluated for the PSC girder model by using the experimentally measured natural frequency and numerically identified natural frequency for several prestress-force cases.

수용가내부 고압배전시스템의 전력손실감소효과 (A Proposed High Voltage Distribution System of the Customer Inside for Reducing Power Loss)

  • 박형준;윤만수;정찬수
    • 조명전기설비학회논문지
    • /
    • 제19권5호
    • /
    • pp.39-44
    • /
    • 2005
  • 에너지절감은 요즈음과 같은 고유가의 시대의 전기 설비 분야의 주요 쟁점중 하나이다. 따라서 전력분야의 여러 기관에서 에너지절감과 관련된 방안과 연구가 진행되고 있는데, 본 논문에서는 전기공학의 기본적인 이론을 바탕으로 하여 중용량 이상의 전력 수용가 내부에서 배전시스템을 변경함으로써 전기에너지의 손실을 절감하는 방안을 제시하였다. 이는 고압의 수전전압을 저압으로 변환하여서 상당한 거리에 떨어져 있는 부하에 전력을 공급하는 일반적인 수용가 내부 배전시스템 대신에, 수전전압을 수용가내의 개별 수전단까지 직접 수전하고 여기서 저압으로 변환하는 것을 의미한다. 이와같은 시스템적인 변경을 통해서, 수용가내의 저압선로가 비교적 긴 아파트단지등에서 상당한 전력에너지의 절감효과를 기대할 수 있으리라 사료된다. 본 논문에서는 기존의 수용가내의 배전시스템과 제안한 배전시스템에서의 전압강하율과 선로전력손실을 비교하여 제안한 배전시스템의 효과를 계산하였다.