• Title/Summary/Keyword: loss angle

Search Result 848, Processing Time 0.024 seconds

A Study of Aging Characteristic of EPDM by High-temperature Treatment (고온 열처리에 의한 EPDM의 열화 특성에 대한 연구)

  • Choi, N.H.;Han, S.I.;Han, S.O.;Yoon, J.Y.;Park, K.S.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1465-1468
    • /
    • 1997
  • In this study we investigated the aging characteristic such as leakage current, dielectric loss, contact angle, of EPDM for outdoor use by thermal treatment. And also observed the color change of surface, changing of chemical ingredient of the marterials by optical microscope. SEMI, FTIR and EDX at the section and surface. The test result show that leakage current is increased with thermal aging time. contact angle and dielectric loss is slightly decreased. Moreover, micro-void or crack in bulk is severely increased with aging time. However, the result affect to the tan $\delta$ at bulk of EPDM. It seems that carrier sources are removed by degassing with heat treatment.

  • PDF

Effect of Impact Angle on the Etching of Glass by Powder Blasting (Powder Blasting 을 이용한 유리의 표면부식시 분사각도의 영향)

  • 김광현;박경호;박동삼
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.349-354
    • /
    • 2001
  • In this study, we investigated the effect of the impacting ang1e of particles, the scanning times and the stand-off distance on the surface roughness and the weight-loss rate of samples with no mask, and the wall profile and overetching of samples with different mask pattern in powder blasting of soda-lime glass. The varying parameters were the different impact angles between 50$^{\circ}$ and 90$^{\circ}$, scanning times of nozz1e up to 40 and the stand-off distances 70mm and 100mm. The widths of mask pattern were 0.2mm, 0.5mm and 1mm. The powder was alumina sharp particles, WA#600. The mass flow rate of powder during the erosion test was fixed constant at 175g/min and the blasting pressure of powder at 0.2MPa

  • PDF

A CASE REPORT OF ANGLE'S CLASS I MALOCCLUSION WITH LOSS OF THE FIRST MOLARS (제 1 대구치 상실을 동반한 Angle씨 제 I 급 부정교합의 치험예)

  • Park, Young Chul;Oh, Sung San
    • The korean journal of orthodontics
    • /
    • v.14 no.1
    • /
    • pp.47-52
    • /
    • 1984
  • A girl aged 13 years 1 month, had a Angle's Class 1 malocclusion, characterized by severe aterior crowding, high canine, and loss of the upper and lower left first molars on account of dental caries. This patient underwent ${\frac{4}{4}}$extraction and multibonded system was used. After 20 Months, anterior crowding and high canine was corrected, and the extraction space as closed on both arch. The upper and lower left 2nd molars occupied the first molar spaces instead of the first polars. After 6 Months from debanding, band spaces were disappeared and the third molars were upting normally.

  • PDF

A Study on Solid Particle Erosion Wear Characteristics of High Cr White Iron Hardfacing by Response Surface Method (반응표면분석에 의한 고 Cr 철계 오버레이 용접부의 분체침식마모 특성의 연구)

  • 이형근
    • Journal of Welding and Joining
    • /
    • v.20 no.4
    • /
    • pp.551-556
    • /
    • 2002
  • Solid particle erosion wear characteristics of high Cr white iron hardfacing were investigated using the erosion wear test method according with the ASTM G76-95. Wear experiments, where the blast angle, blast distance and blast pressure were selected as test variables, were planned and analyzed by response surface method (RSM to evaluate the wear loss statistically and quantitatively. The measured wear losses well coincided with the calculated ones by the experimental equation. The wear loss of high Cr cast iron hardfacing was increased with blasting pressure, but affected in a complicated way by the blasting angle and distance. Erosion wear of high Cr cast iron hardfacing could be well predicted by RSM analysis of wear variables.

A study for the changer of resistance and influence of the dioctylphthalate by irradiation on the polyvinyl chloride (폴리염화비닐에 방사선 조사시의 저항의 변화와 가소제의 영향)

  • 신종원;백용현
    • 전기의세계
    • /
    • v.30 no.10
    • /
    • pp.639-644
    • /
    • 1981
  • PVC is a kind of electric insulation polymer. But we get some deteriorations in electrical characteristics of the PVC, when it is used on the radioactive field. In order to find out the cause of the deterioration, we investigate the surface-resistance, volume-resistance, dielectric constant and dielectric loss angle of the soft and hard PVC which is irradiated by the Co$^{60}$ .gamma. radioactivity. From the experiment, we can conclude the followings 1. Radio-activity proof characteristic in the soft PVC is stronger than in the hard PVC. 2. The resistance of PVC which is irradiated by the radio-activity decrease exponentially. 3. The dielectric constant and the dielectric loss angle of PVC irradiated by Co$^{60}$ .gamma.ray reach maximum value in first few time.

  • PDF

The effects of high sustained +Gz under different seat back angles (조종석 각도변화가 양성 가속도에 미치는 영향에 관한 연구)

  • 이창민;박세권
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.69-78
    • /
    • 1996
  • Current fighter pilots, flying new generation aircrafts with high performance, are under severe stress during aerial combat maneuvering when they are exposed to high sustained +Gz(Head-to-foot) acceleration stress. Two major factor limiting performance during high sustaied +Gz acceleration stress are loss of vision-greyout or blackout, and loss of consciousness (LOC). These symptoms are believed to occur as a result of insuff- icient blood flow to the retina and the brain. This study was conducted to evaluate the effects of high sustained +Gz stress under different seat back angle. The results. obtained by the biodvanmic computer simulations using the ATB(articulated total body) model, are represented with respect to three variables, such as HIC(head injury criterion) value, average G, and maximum G. The results demonstrate that the seat back angle(over $30^{\circ}C$) had a significant effect to decrease +Gz stress on the head segment and had no significant effect on HIC.

  • PDF

Critical Current and AC loss Characteristics with Pitch of HTS tape (HTS tape의 Pitch에 따른 임계전류 및 교류손실 특성)

  • Kim, Hae-Joon;Sim, Ki-Deok;Kim, Jae-Ho;Kim, Seok-Ho;Cho, Jeon-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.265-266
    • /
    • 2006
  • Superconductor is developed for applications in high-power devices such as power-transmission cables, transformers, motor and generators. In such applications, HTS tapes are subjected to various kinds of stress or strain. In the fabrication of the devices, the critical current (Ic) of the high temperature superconductor degrades due to many reasons including the tension applied by bending, twist and thermal contraction. In particular manufactured HTS cable, we need pitch angle controls. This paper is analyzed that Ic characteristics is changed pitch angle of HTS tape. These results will amount the most important basis data in HTS cable.

  • PDF

Harmonic Bun Analysis of Traction Motor in the High Speed Train with the Distributed Tractions (운전 특성을 고려한 고속 전철용 영구자석 동기전동기의 철손 해석)

  • Seo, Jang-Ho;Lim, Jae-Won;Lee, Sang-Yub;Jung, Ryun-Kyo
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.267-274
    • /
    • 2009
  • To predict efficiency of Interior Permanent Magnet Synchronous Motors(IPMSM) and to cope with the demagnetization risk of permanent magnets used in the IPMSM, accurate iron analysis of the IPMSM is very important at the motor design stage. In the analysis, we calculate the operation condition such as rotor speed and current angle. and then, we analyzed the iron loss of the machine for electric vehicle according to its driving condition. From the analysis results, it was shown that the harmonic iron losses of stator are larger than before at field-weakening region. In addition, it was revealed that rotor iron loss mainly induced by stator slot-ripples is independent of current angle and only varied according to the speed.

  • PDF

Numerical Analysis on Cascade Performance of Double-Circular-Arc Hydrofoil (수치 모사를 통한 이중원호 익렬의 성능 예측)

  • Jeong, Myeong-Gyun;O, Jae-Min;Paeng, Gi-Seok;Song, Jae-Uk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.432-438
    • /
    • 2002
  • In order to design and analyze the performance of an axial-flow pump it is necessary to know the flow deviation, deflection angle and pressure loss coefficient as a function of the angle of incidence for the hydrofoil section in use. Because such functions are unique to the particular section, however, general correlation formulae are not available for the multitude of hydrofoil profiles, and such functions must be generated by either experiment or numerical simulation for the given or selected hydrofoil section. The purpose of present study is to generate design correlations for hydrofoils with double circular arc (DCA) camber by numerical analysis using a commercial code, FLUENT. The cascade configuration is determined by a combination of the inlet blade angle, blade thickness, camber angle, and cascade solidity, and a total of 90 cascade configurations are analyzed in this study. The inlet Reynolds number based on the chord and the inlet absolute velocity is fixed at 5${\times}$10$\^$5/. Design correlations are formulated, based on the data at the incidence angle of minimum total pressure loss. The correlations obtained in this way show good agreement with the experiment data collected at NASA with DCA hydrofoils.

Impact of Screw Type on Kyphotic Deformity Correction after Spine Fracture Fixation: Cannulated versus Solid Pedicle Screw

  • Arbash, Mahmood Ali;Parambathkandi, Ashik Mohsin;Baco, Abdul Moeen;Alhammoud, Abduljabbar
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.1053-1059
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To detect the effect of cannulated (poly-axial head) and solid (mono-axial head) screws on the local kyphotic angle, vertebral body height, and superior and inferior angles between the screw and the rod in the surgical management of thoracolumbar fractures. Overview of Literature: Biomechanics studies showed that the ultimate load, yield strength, and cycles to failure were significantly lower with cannulated (poly-axial head) pedicle comparing to solid core (mono-axial head). Methods: The medical charts of patients with thoracolumbar fractures who underwent pedicle screw fixation with cannulated or solid pedicle screws were retrospectively reviewed; the subjects were followed up from January 2011 to December 2015. Results: Total 178 patients (average age, $36.1{\pm}12.4years$; men, 142 [84.3%]; women, 28 [15.7%]) with thoracolumbar fractures who underwent surgery and were followed up at Hamad Medical Corporation were classified, based on the screw type as those with cannulated screws and those with solid screws. The most commonly affected level was L1, followed by L2 and D12. Surgical correction of the local kyphotic angle was significantly different in the groups; however, there was no significant difference in the loss of correction of the local kyphotic angle of the groups. Surgical correction of the reduction in the vertebral body height showed statistical significance, while the average loss of correction in the reduction of the vertebral body height was not significantly different. The measurement of the angles made by the screws on the rods was not significantly different between the cannulated (poly-axial head) and solid (mono-axial head) screw groups. Conclusions: Solid screws were superior in terms of providing increased correction of the kyphotic angle and height of the fractured vertebra than the cannulated screws; however, no difference was noted between the screws in the maintenance of the superior and inferior angles of the screw with the rod.