• Title/Summary/Keyword: loss angle

Search Result 843, Processing Time 0.033 seconds

Design Method for a Total Internal Reflection LED Lens with Double Freeform Surfaces for Narrow and Uniform Illumination

  • Yang, Jae Suk;Park, Jae-Hyeung;O, Beom-Hoan;Park, Se-Geun;Lee, Seung Gol
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.614-622
    • /
    • 2016
  • In this paper, we propose a novel differential equation method for designing a total internal reflection (TIR) LED lens with double freeform surfaces. A complete set of simultaneous differential equations for the method is derived from the condition for minimizing the Fresnel loss, illumination models, Snell’s Law of ray propagation, and a new constraint on the incident angle of a ray on the light-exiting surface of the lens. The last constraint is essential to complete the set of simultaneous differential equations. By adopting the TIR structure and applying the condition for minimizing the Fresnel loss, it is expected that the proposed TIR LED lens can have a high luminous flux efficiency, even though its beam-spread angle is narrow. To validate the proposed method, three TIR LED lenses with beam-spread angles of less than 22.6° have been designed, and their performances evaluated by ray tracing. Their luminous flux efficiencies could be obviously increased by at least 35% and 5%, compared to conventional LED lenses with a single freeform surface and with double freeform surfaces, respectively.

The development of joint angle sensor using optical fiber (광파이버를 이용한 관절각 센서의 개발)

  • Lee, Hyeon-Hee;Lim, Seung-Kwan;Jeong, Ho-Chun;Lee, Tea-Ho;Chin, Dal-Bok
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.593-596
    • /
    • 1997
  • The main purpose of this paper is to develop sensing device of joint angle using loss of opfical fiber. The source of light to optical fiber is infrared rays diode, and receiver is a photo transistor. The bent angle of optical fiber is measured with rotary encoder, and The change of voltage due to the loss of light is measured with micro computer PIC16C74. The sensing device may be used to Functional Electrical stimulation(FES) System for Rehabilitation patient.

  • PDF

Off-Design Performance Prediction of an Axial Flow Compressor Stage Using Simple Loss Correlations (간단한 손실모델을 이용한 단단축류압축기 탈설계점 성능예측)

  • 김병남;정명균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3357-3368
    • /
    • 1994
  • Total pressure losses required to calculate the total-to-total efficiency are estimated by integrating empirical loss coefficients of four loss mechanisms along the mean-line of blades as follows; blade profile loss, secondary flow loss, end wall loss and tip clearance loss. The off-design points are obtained on the basis of Howell's off-design performance of a compressor cascade. Also, inlet-outlet air angles and camber angle are obtained from semi-empirical relations of transonic airfoils' minimum loss incidence and deviation angles. And nominal point is replaced by the design point. It is concluded that relatively simple loss models and Howell's off-design data permit us to calculate the off-design performance with satisfactory accuracy. And this method can be easily extended for off-design performance prediction of multi-stage compressors.

Variation of Pressure Loss and IPF Flowing Ice Slurry in Straight Tube Inclined to Various Angle (다양한 각도로 기울어진 직관내에서 아이스슬러리 유동시 압력손실과 IPF 변화)

  • Kim Kyu-Mok;Park Ki-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1028-1034
    • /
    • 2004
  • Recently, the ice storage system using ice slurry has been used increasingly since it has been introduced where the rapid cooling load change is required. Because it overcomes a decrease of the melting performance and an increase of the thermal resistance on the ice layer in static ice thermal storage system. This study is performed to understand the effects of transporting ice slurry through horizontal, vertical and inclined tubes ($30^{\circ},\;45^{\circ}$). It used propylene glycol-water solution and ice particles (diameter of about 2 mm) in this experiment. The experiments were carried out under various conditions, with concentration of water solution ranging from 0 to $20wt\%$, and velocity of water solution at the entry ranging from 1.5 to 2.5 m/s. The results were as follows: Regarding the angle of inclined tube, the highest pressure loss was measured for vertical tube and the pressure loss for $45^{\circ},\;30^{\circ}$, horizontal straight tubes were lower successively. The lowest pressure loss in these tubes was measured at velocity of $2.0{\sim}2.5m/s$ and concentration of $10wt\%$. The outlet IPF was likewise stable in these ranges.

The optimum design of optical transmitting antenna versus elevation angle on the optical satellite communication up-link for B-ISDN (B-ISDN용 광위성 통신 업링크의 앙각에 따른 송신안테나 최적설계에 관한 연구)

  • 한종석;이준구;정진호;김영권
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.10
    • /
    • pp.64-72
    • /
    • 1995
  • In this paper, atmospheric turbulence and absorption under clear weather condition, which affect the optical satellite up-link communication between geo-satellites and earth station, were studied. In case of the up-link communication, the received optical power is weakened by pointing loss caused by beam tilt which is the main effect of turbulent atmosphere. This pointing loss directly has relation to the diameter of optical transmitting antenna. From the inverse proportion of the pointing and spaced loss, it is the regions where the diameter of transmitting antenna increases abruptly and the efficient design of transmitting antenna is impossible. In case of using channel coding, it was shown that the peak value of diameter moved to the lower regions of elevation angle with increasing the coding gain and its width was also decreased. In case of considering both coding gain and transmission rate on the design of transmitting antenna, it was known that more coding gain was necessary as transmission rate was increased.

  • PDF

Improvement of Performance Instability and Miniaturization of Very Low Specific Speed Centrifugal Pump (극저비속도 원심펌프의 불안정성능개선 및 소형화에 관한 연구)

  • Choi, Young-Do;Kurokawa, Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.4
    • /
    • pp.21-28
    • /
    • 2007
  • The ratio of disk friction loss in a centrifugal pump is very large for the total pump loss in the range of very low specific speed. Therefore, impeller radius should be shortened to increase the pump efficiency because the disk friction loss is proportional to the fifth power of impeller radius. In order to compensate the decreased head by the shortened impeller radius, vane angle at impeller outlet should be increased. However, as the vane angle at impeller outlet becomes larger, performance instability occurs at low flow rate regions. In this study, J-Groove is adopted to suppress the performance instability and detailed examination is performed for the influence of the J-Groove on the pump performance. The results show that J-Groove gives good effect on the suppression of performance instability. Moreover, as J-Groove increases pump head considerably, the pump size can be smaller for head requirements.

The Magnetization Losses Characteristics of Multi-stacked and Variable Angle of External Magnet Field in YBCO CC and BSCCO tape (YBCO Coated Conducor와 BSCCO tape의 적층 및 외부자장의 각도에 따른 자화손실 특성)

  • Lim, Hyoung-Woo;Lee, Hee-Joon;Cha, Guee-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.34-38
    • /
    • 2005
  • Multi-stacked HTS tapes are needed to conduct large current in the power application. In this paper, magnetization losses of the multi-stacked YBCO coated conductor and the BSCCO tape have been measured and compared. Magnetization losses of single tape, 2-stacked, 3-stacked and 4-stacked HTS tapes have been presented in this paper. Multi-stacked tapes have been fabricated using face-to-face type stacking method. Measurements of magnetization loss were performed under various angle of external magnetic field to consider the anisotropic characteristics of HTS tapes. Test results show that loss density per unit volume decreased for both YBCO coated conductors and BSCCO tapes when the stacking number of tapes is increased. The magnetization losses of YBCO CC are larger than those of BSCCO tapes when the external magnetic field is increased.

Numerical Investigation on Permanent-Magnet Eddy Current Loss and Harmonic Iron Loss for PM Skewed IPMSM

  • Lim, Jin-Woo;Kim, Yong-Jae;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.417-422
    • /
    • 2011
  • This paper presents the characteristics of PM eddy current loss and harmonic iron loss for PM step-skewed Interior Permanent Magnet Synchronous Motor (IPMSM) with concentrated windings and multi-layered PM under the running condition of maximum torque per ampere (MTPA) and flux-weakening control. In particular, PM eddy current loss and harmonic iron loss in IPMSM have been numerically computed with three-dimensional Finite Element Analysis (3D FEA), whereby IPMSM with concentrated windings and multi-layered PM has been designed to identify the optimized skew angle contributing to the reduced PM eddy current loss and torque ripples, while maintaining the required average torque. Furthermore, numerical investigation on PM eddy current loss and iron loss at MTPA and flux-weakening control has been carried-out in terms of PM step-skew.

Determination of Optimal Operating Angle for HVDC System (전류형 HVDC 시스템의 최적 운전각 결정)

  • Kim, Jin-Young;Kim, Jae-Han;Kim, Chan-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.7-15
    • /
    • 2012
  • In this paper a process of determination for thyristors operating with optimal angle is described. The proposed method is based on the trade-off between the cost(due to rating and loss) and controllability of the system. Large control angle increases controllability of HVDC system and also increase the rating of the system which leads to a high price. Therefore it is important to determine a control angle at a first step of design procedure. This paper shows a rating trend of C.Tr, Valve and Filter due to control angle variation, and then introduces a determination process of the HVDC operating angle.

Measurement of Dynamic Compressive Properties of Apples using the Oscillatory Test

  • Lee, Jong-Whan;Tan, Jinglu;Waluyo, Sri
    • Journal of Biosystems Engineering
    • /
    • v.37 no.1
    • /
    • pp.28-35
    • /
    • 2012
  • Purpose: This study performed the oscillatory test using the texture analyzer to characterize the viscoelastic behavior of apples such as the storage modulus (E'), the loss modulus (E"), the complex modulus (${\mid}E^*{\mid}$) and the energy dissipated per cycle ($W_{diss}$). Methods: The sinusoidal deformation with the frequency of 1-10 Hz and the maximum displacement of 0.1 mm were applied to the flesh tissues of Fuji, Golden Delicious and Red Delicious apples. The Lissajous figure was used to measure the phase angle(${\delta}$) between stress and strain curve. Results: Trigger force was critical to the measurement of the phase angle. E', E", ${\mid}E^*{\mid}$ and Wdiss were measured using the Lissajous figure and the phase angle. The complex modulus of Golden Delicious apple was significantly lower than those of Fuji apple and Red Delicious apple. Conclusions: Apple flesh was exhibiting more elasticity at low frequency, and more viscosity at high frequency. Dynamic compressive properties of Fuji apple were similar to those of Red Delicious apple but significantly different from those of Golden Delicious apple.