• 제목/요약/키워드: longitudinal wave

검색결과 478건 처리시간 0.024초

초음파를 이용한 중회귀분석법에 의한 콘크리트의 압축강도추정 (Estimate of Compressive Strength for Concrete using Ultrasonics by Multiple Regression Analysis Method)

  • 박익근;한응교;김완규
    • 비파괴검사학회지
    • /
    • 제11권2호
    • /
    • pp.22-31
    • /
    • 1991
  • Various types of ultrasonic techniques have been used for the estimation of compressive strength of concrete structures. However, conventional ultrasonic velocity method using only longitudial wave cannot be determined the compressive strength of concrete structures with accuracy. In this paper, by using the introduction of multiple parameter, e. g. velocity of shear wave, velocity of longitudinal wave, attenuation coefficient of shear wave, attenuation coefficient of longitudinal wave, combination condition, age and preservation method, multiple regression analysis method was applied to the determination of compressive strength of concrete structures. The experimental results show that velocity of shear wave can be estimated compressive strength of concrete with more accuracy compared with the velocity of longitudinal wave, accuracy of estimated error range of compressive strength of concrete structures can be enhanced within the range of ${\pm}$10% approximately.

  • PDF

단일 위치에서의 측정을 이용한 가속도 종파 분리 방법의 개발 (Development of longitudinal acceleration wave decomposition method with single point measurement)

  • 정병보;박영진;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.629-633
    • /
    • 2006
  • We investigated a new longitudinal acceleration wave decomposition method in time domain. The proposed method separates up- and down-stream waves with an axial strain and axial acceleration measured at a single point on the transmission path. The advantages such as low computation load and easy implementation would be possible by developing time domain under the following assumptions; low frequency range, uniform cross sectional area and elastic wave propagation. We confirmed the feasibility and performance of the method through experiment using Split Hopkinson Pressure Bar (SHPB). The method can be effective in several applications, including active vibration control with wave view point, where real time wave decomposition is necessary.

  • PDF

콘크리트에서의 One-Sided 응력파 속도 측정 기법의 적용에 관한 연구 (Application Advanced One-Sided Stress Wave Velocity Measurement in Concrete)

  • 이준현;송원준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.544-550
    • /
    • 1997
  • In this study, the advanced on-sided stress wave velocity measurement method was applied to investigate the effects of composition, age and moisture content in concrete. Two concrete specimens that have different composition were used to figure out the change of the Longitudinal and Surface wave velocity due to different composition. The other concrete specimen was cast and the Longitudinal and Surface wave velocity was monitored during curing process. After 28-day old, the effect of moisture content in the concrete specimen to the stress wave velocity is presented in this paper during the time period 43-74 days after casting. For drying process. an aggregate drying oven was used. A conventional ultrasonic through transmission method was used to compare with the results determined by the one-sided method.

  • PDF

Longitudinal Cut 파형해석의 응용을 위한 특성연구 (Study on th Wave-Pattern Analysis by Longitudinal Cut Method)

  • 강신형;이영길
    • 대한조선학회지
    • /
    • 제18권1호
    • /
    • pp.9-18
    • /
    • 1981
  • The wave-pattern analysis has been one of important research tools in the towing tank, and applied for hull form design. The longitudinal-cut method of Newman and Sharma is adopted in KRIS deep towing tank. Instrumentations and data acquisition systems are developed for that. Local effects and truncation effects are estimated by using calculated wave patterns of simple source distributions. Wigley model of 2m is used to check the accuracy of the whole system. Cut positions and truncation points are changed to investigate characteristics of the wave-pattern analysis. Coefficients of wave-pattern resistance are low-estimated in comparison with those of Maruo and Ikehata. The general quality of the system is very good, but some more efforts to increase the accuracy are required. Two full-form models(one basic form, the other with bulbous bow) are tested to show high application-possibilities of the wave-pattern analysis for the hull form design.

  • PDF

초음파 음속측정에 의한 응력평가에 관한 연구 (Stress Evaluation by Measuring Ultrasonic Velocity)

  • 이범성
    • 한국정밀공학회지
    • /
    • 제16권2호통권95호
    • /
    • pp.138-144
    • /
    • 1999
  • Longitudinal wave and shear wave velocity changes of PMMA Polymer meterial under the the unidirection load were measured. The Third-order elastic modulus and acousto-elastic modulus of PMMA are obtained. The theoretical and experemental values of the velocity change of each wave by stress are compared each other and the validity of theoretical expression is examinated.

  • PDF

Material Characterization of Weld-Zone Using Poisson's Ratio Distribution

  • Park, Jin-Ha;Kim, Young-H.;Lee, Seung-S.;Kim, Young-Gil
    • 비파괴검사학회지
    • /
    • 제29권6호
    • /
    • pp.586-590
    • /
    • 2009
  • Poisson's ratio, one of elastic constants of elastic solids, has not attracted attention due to its narrow range and difficult measurement. Transverse wave velocity as well as longitudinal wave velocity should be measured for nondestructive measurement of Poisson's ratio. Rigid couplants for transverse wave is one of obstacle for scanning over specimen. In the present work, a novel measurement of Poisson's ratio distribution was applied. Immersion method was employed for the scanning over the specimen. Echo signals of normal beam longitudinal wave were collected, and transverse wave modes generated by mode conversion were identified. From transit time of longitudinal and transverse waves, Poisson's ratio was determined without the information of specimen thickness. Poisson's ratio distribution of the carbon steel weldment was mapped. Heat affected zone of the weldment was clearly distinguished from base and filler metals.

Poisson's Ratio Scanning Using Immersion Ultrasonic Testing

  • Oh, Seo-Young;Kim, Young-H.;Shin, Yo-Sub;Cho, Hyun-Joon
    • 비파괴검사학회지
    • /
    • 제28권6호
    • /
    • pp.519-523
    • /
    • 2008
  • Poisson's ratio is one of elastic constants of elastic solids. However, it has not attracted attention due to its narrow range and difficult measurement. Transverse wave velocity as well as longitudinal wave velocity should be measured for nondestructive measurement of Poisson's ratio. Hard couplant for transverse wave prevents transducer from scanning over specimen. In the present work, a novel measurement of Poisson's ratio distribution was proposed. Immersion method was employed for the scanning over the specimen. Echo signals of normal beam longitudinal wave were collected. Transverse wave modes generated by mode conversion were identified. From transit time of longitudinal and transverse waves, Poisson's ratio can be determined without information of specimen thickness. This technique was demonstrated for aluminum and steel specimens.

전단 자극에 의한 심방 근세포 칼슘 웨이브의 발생: Phospholipase C-이노시톨 1,4,5-삼인산 수용체 신호전달의 역할 (Activation of a Ca2+ wave by Shear Stress in Atrial Myocytes: Role of Phospholipase C-inositol 1,4,5-Trisphosphate Receptor Signaling)

  • 김준철;우선희
    • 약학회지
    • /
    • 제59권4호
    • /
    • pp.158-163
    • /
    • 2015
  • Cardiac myocytes are subjected to fluid shear stress during each contraction and relaxation. Under pathological conditions, such as valve disease, heart failure or hypertension, shear stress in cardiac chamber increases due to high blood volume and pressure. The shear stress induces proarrhythmic longitudinal global $Ca^{2+}$ waves in atrial myocytes. In the present study, we further explored underlying cellular mechanism for the shear stress-induced longitudinal global $Ca^{2+}$ wave in isolated rat atrial myocytes. A shear stress of ${\sim}16dyn/cm^2$ was applied onto entire single myocyte using pressurized fluid puffing. Confocal $Ca^{2+}$ imaging was performed to measure local and global $Ca^{2+}$ signals. Shear stress elicited longitudinally propagating global $Ca^{2+}$ wave (${\sim}80{\mu}m/s$). The occurrence of shear stress-induced atrial $Ca^{2+}$ wave was eliminated by the inhibition of ryanodine receptors (RyRs) or inositol 1,4,5-trisphosphate receptors ($IP_3Rs$). In addition, pretreatment of phospholipase C (PLC) inhibitor U73122, but not its inactive analogue U73343, abolished the generation of longitudinal $Ca^{2+}$ wave under shear stress. Our data suggest that shear-induced longitudinal $Ca^{2+}$ wave may be induced by $Ca^{2+}$-induced $Ca^{2+}$ release through the RyRs which is triggered by $PLC-IP_3R$ signaling in atrial myocytes.

Nondestructive Characterization of Materials Using Laser-Generated Ultrasound

  • Park, Sang-Woo;Lee, Joon-Hyun
    • International Journal of Reliability and Applications
    • /
    • 제5권1호
    • /
    • pp.1-13
    • /
    • 2004
  • It is recently well recognized that the technique for the one-sided stress wave velocity measurement in structural materials provides measurement in structural materials provides valuable information on the state of the material such as quality, uniformity, location of cracked or damaged area. This technique is especially effective to measure velocities of longitudinal and Rayleigh waves when access to only one surface of structure is possible. However, one of problems for one-sided stress wave velocity measurement is to get consistent and reliable source for the generation of elastic wave. In this study, the laser based surface elastic wave was used to provide consistent and reliable source for the generation of elastic wave into the materials. The velocities of creeping wave and Rayleigh wave in materials were measured by the one-sided technique using laser based surface elastic wave. These wave velocities were compared with bulk wave velocities such as longitudinal wave and shear wave velocities to certify accuracy of measurement. In addition, the mechanical properties such as poisson's ratio and specific modulus(E/p) were calculated with the velocities of surface elastic waves.

  • PDF

초음파를 이용한 복합재료 기계적 특성값의 새로운 특정 방법 (A New Method for Characterization of Composites by Ultrasonics)

  • 장필성;전홍재
    • Composites Research
    • /
    • 제13권2호
    • /
    • pp.1-7
    • /
    • 2000
  • 일방향 복합재료의 기계적 특성값을 비파괴적으로 얻기 위하여 초음파를 이용한 새로운 시험 방법을 제안하였다. 제안된 접촉식 시험 방법에서, 파속도를 측정하기 위하여 종파용 탐촉자만이 through-transmission 방식으로 사용되었다. 알루미늄 쐐기와 알루미늄 직육면체 형태의 보조적인 매질이 시편의 양쪽에 부착되었다. 경사 입사된 종파는 쐐기에서 시편으로 전파되며, 입사된 파는 시편과 두 개의 매질의 경계면에서 연속적으로 모드 변환된다. 마지막 매질에서 종파로 모드 변환된 파속도를 측정함으로써 시편의 기계적 특성값을 결정하는데 필요한 모든 정보를 얻게된다. 이 과정에서 전단 강성 계수를 얻기 위해, 수신된 종파로부터 간접적으로 횡파의 속도를 측정하였다. 본 연구에는 재료의 이방성이 파에 미치는 영향 또한 고려되었다.

  • PDF