• Title/Summary/Keyword: longitudinal shear capacity

Search Result 112, Processing Time 0.035 seconds

Experimental study on effect of EBRIG shear strengthening method on the behavior of RC beams

  • Shomali, Amir;Mostofinejad, Davood;Esfahani, Mohammad Reza
    • Advances in concrete construction
    • /
    • v.8 no.2
    • /
    • pp.145-154
    • /
    • 2019
  • The present experimental study addresses the structural response of reinforced concrete (RC) beams strengthened in shear. Thirteen RC beams were divided into four different sets to investigate the effect of transverse and longitudinal steel reinforcement ratios, concrete compressive strength change and orientation for installing carbon fiber-reinforced polymer (CFRP) laminates. Then, we employed a shear strengthening solution through externally bonded reinforcement in grooves (EBRIG) and externally bonded reinforcement (EBR) techniques. In this regard, rectangular beams of $200{\times}300{\times}2000mm$ dimensions were subjected to the 4-point static loading condition and their load-displacement curves, load-carrying capacity and ductility changes were compared. The results revealed that using EBRIG method, the gain percentage augmented with the increase in the longitudinal reinforcement ratio. Also, in the RC beams with stirrups, the gain in shear strength decreased as transverse reinforcement ratio increased. The results also revealed that the shear resistance obtained by the experimental tests were in acceptable agreement with the design equations. Besides, the results of this research indicated that using the EBRIG system through vertical grooves in RC beams with and without stirrups caused the energy absorption to increase about 85% and 97%, respectively, relative to the control.

Experimental shear strengthening of GFRC beams without stirrups using innovative techniques

  • Hany, Marwa;Makhlouf, Mohamed H.;Ismail, Gamal;Debaiky, Ahmed S.
    • Structural Engineering and Mechanics
    • /
    • v.83 no.4
    • /
    • pp.415-433
    • /
    • 2022
  • Eighteen (18) (120×300×2200 mm) beams were prepared and tested to evaluate the shear strength of Glass Fiber Reinforced Concrete (GFRC) beams with no shear reinforcement, and evaluate the effectiveness of various innovative strengthening systems to increase the shear capacity of the GFRC beams. The test variables are the amount of discrete glass fiber (0.0, 0.6, and 1.2% by volume of concrete) and the type of longitudinal reinforcement bars (steel or GFRP), the strengthening systems (externally bonded (EB) sheet, side near-surface mounted (SNSM) bars, or the two together), strengthening material (GFRP or steel) links, different configurations of NSM GFRP bars (side bonded links, full wrapped stirrups, side C-shaped stirrups, and side bent bars), link spacing, link inclination angle, and the number of bent bars. The experimental results showed that adding the discrete glass fiber to the concrete by 0.6%, and 1.2% enhanced the shear strength by 18.5% and 28%, respectively in addition to enhancing the ductility. The results testified the efficiency of different strengthening systems, where it is enhanced the shear capacity by a ratio of 28.4% to 120%, and that is a significant improvement. Providing SNSM bent bars with strips as a new strengthening technique exhibited better shear performance in terms of crack propagation, and improved shear capacity and ductility compared to other strengthening techniques. Based on the experimental shear behavior, an analytical study, which allows the estimation of the shear capacity of the strengthened beams, was proposed, the results of the experimental and analytical study were comparable by a ratio of 0.91 to 1.15.

Shear bond failure in composite slabs - a detailed experimental study

  • Chen, Shiming;Shi, Xiaoyu;Qiu, Zihao
    • Steel and Composite Structures
    • /
    • v.11 no.3
    • /
    • pp.233-250
    • /
    • 2011
  • An experimental study has been carried out to reveal the shear-bond failure mechanism of composite deck slabs. Thirteen full scale simply supported composite slabs are studied experimentally, with the influence parameters like span length, slab depth, shear span length and end anchorage provided by steel headed studs. A dozen of strain gauges and LVDTs are monitored to capture the strain distribution and variation of the composite slabs. Before the onset of shear-bond slip, the longitudinal shear forces along the span are deduced and found to be proportional to the vertical shear force in terms of the shear-bond strength in the m-k method. The test results are appraised using the current design procedures. Based on the partial shear-bond connection at the ultimate state, an improved method is proposed by introducing two reduction factors to assess the moment resistance of a composite deck slab. The new method has been validated and the results predicted by the revised method agree well with the test results.

Experimental investigation on shear capacity of RC beams with GFRP rebar & stirrups

  • Vora, Tarak P.;Shah, Bharat J.
    • Steel and Composite Structures
    • /
    • v.21 no.6
    • /
    • pp.1265-1285
    • /
    • 2016
  • This paper presents experimental results of advanced investigation carried out on the beams reinforced with Glass Fiber Reinforced Polymer (GFRP) rebar and stirrups. Twelve beams reinforced with GFRP and one beam with steel reinforcement of size $230{\times}300{\times}2000mm$ were investigated. Longitudinal reinforcement, shear span and spacing of stirrups were the main variables to form the set. In advanced testing three types of strain gauges for steel, composite and concrete surface were applied to observe strain/stress development against the applied load. Live data were recorded from four strain gauges applied on stirrups, one at center on longitudinal reinforcement, two on the concrete surface and central deflection during the test. Although the focus of the paper was mainly on the behavior of GFRP shear reinforcement, other parallel data were observed for the completeness of the test. Design recommendations of ISIS Canada Design Manual (2007), Japan Society of Civil Engineers (1997) and American Concrete Institute (ACI-440.1R-06) were reviewed. Shear design predictions were compared with experimental results in which it was observed that all the three standards provided conservative predictions. However, ACI found most efficient compare to other two there is room to improve the efficiency of the recommendations.

Longitudinal Elongation of Slender Reinforced Concrete Beams Subjected to Cyclic Loading (주기하중을 받는 세장한 철근콘크리트 보의 길이방향 인장변형)

  • Eom, Tae-Sung;Park, Hong-Gun;Kang, Su-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.169-172
    • /
    • 2008
  • Longitudinal elongation develops in reinforced concrete beams that exhibit flexural yielding during cyclic loading. The longitudinal elongation can decrease the shear strength and deformation capacity of the beams. In the present study, nonlinear truss model analysis was performed to study the elongation mechanism of reinforced concrete beams. The results showed that residual tensile plastic strain of the longitudinal reinforcing bar in the plastic hinge is the primary factor causing the member elongation, and that the shear-force transfer mechanism of diagonal concrete struts has a substantial effect on the magnitude of the elongation. Based on the analysis results, a simplified method for evaluating member elongation was developed. The proposed method was applied to test specimens with various design parameters and loading conditions..

  • PDF

Evaluation of Deformation Capacity of Slender Reinforced Concrete Walls with Thin Web (얇은 두께의 웨브를 갖는 세장한 벽체의 변형 능력 평가)

  • Eom, Tae-Sung;Park, Hong-Gun;Kim, Jae-Yo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.59-68
    • /
    • 2010
  • In the present study, the deformation capacity of slender shear walls with thin web subject to inelastic deformation after flexural yielding was studied. Web-crushing and rebar-fracture were considered as the governing failure mechanisms of walls. To address the effect of the longitudinal elongation on web-crushing and rebar-fracture, the longitudinal elongation was predicted by using truss model analysis. The failure criteria by web-crushing and rebar-fracture were defined as a function of the longitudinal elongation. The proposed method was applied to 17 shear wall specimens with boundary columns, and the prediction results were compared with the test results. The results showed that proposed method predicted the maximum deformations and failure modes of the wall specimens with reasonable precision.

Seismic Response Analysis of Reinforced Concrete Wall Structure Using Macro Model

  • Kim, Dong-Kwan
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.1
    • /
    • pp.99-112
    • /
    • 2016
  • During earthquake, reinforced concrete walls show complicated post-yield behavior varying with shear span-to-depth ratio, re-bar detail, and loading condition. In the present study, a macro-model for the nonlinear analysis of multi-story wall structures was developed. To conveniently describe the coupled flexure-compression and shear responses, a reinforced concrete wall was idealized with longitudinal and diagonal uniaxial elements. Simplified cyclic material models were used to describe the cyclic behavior of concrete and re-bars. For verification, the proposed method was applied to various existing test specimens of isolated and coupled walls. The results showed that the predictions agreed well with the test results including the load-carrying capacity, deformation capacity, and failure mode. Further the proposed model was applied to an existing wall structure tested on a shaking table. Three-dimensional nonlinear time history analyses using the proposed model were performed for the test specimen. The time history responses of the proposed method agreed with the test results including the lateral displacements and base shear.

An Analytical Study on the Shear Capacity of Reinforced Concrete Member with Small Shear Span Ratio (전단스팬비가 작은 철근콘크리트 부재의 전단내력평가에 관한 해석적 연구)

  • 강석화
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.5
    • /
    • pp.193-202
    • /
    • 1994
  • In this study, an equation for modelling the shear strength of reinforced concrete member with web reinforcement is proposed. Although the general formulas for shear strength of reinforced concrete member with small a /d are obtained based on the experimental results, the proposed equation herein is derived from lower bound theorem of limit analysis. The proposed model takes into account arch mechanism and truss mechanism. And ir provides the values of divided shear strength ratio of each mechanism as well as visual understanding of the mechanism on how the given load is transfered to the support. Also, the model takes into account the effect of a /d. longitudinal reinforcement ratio, and web reiriforcement ratio quantitively. Based on the comparisons of the result of this model with previous, test results, it shows good agreements.

New Approach for Shear Capacity Prediction of High Strength Concrete Beams without Stirrups (스터럽이 없는 고강도 콘크리트 보의 전단강도 예측을 위한 새로운 예측식의 제안)

  • Choi, Jeong-Seon;Lee, Chang-Hoon;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.611-620
    • /
    • 2006
  • In the shear failure mechanism of a beam, beam and arch actions always exist simultaneously. According to the shear span to depth ratio, the proportion between these two actions is varied and the contribution of these actions to shear capacity is changed. Moreover, the current codes provide recommendations based on experimental results of normal strength concrete, so the application range of concrete strength must be extended. Based on this mechanism and new requirement, a simplified analytical equation for shear capacity prediction of reinforced high strength concrete beams without stirrups is proposed. To reflect the change in the contribution between these actions, stress variation in the longitudinal reinforcement along the span is considered by use of the Jenq and Shah Model. Dowel action with horizontal splitting failure and shear friction between cracks are also taken into account. ize effect is included to derive a more precise equation. Regression analysis is performed to determine each variable and simplify the equation. And, the formula derived from theoretical approaches is evaluated by comparison with numerous experimental data, which are in broad range of concrete strength(especially in high strength concrete), shear span to depth ratio, geometrical size and longitudinal steel ratio. It is shown that the proposed equation is more accurate and simpler than other empirical equations, so a wide range of a/d can be considered in one equation.

Seismic Performance Evaluation of Shear-Critical R/C Bridge Piers Retrofitted with Fiber Sheets (섬유 보강된 휨전단 RC교각의 내전성능 평가)

  • 송호진;정영수;김용곤;이은희
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.195-202
    • /
    • 2002
  • Lap splices of longitudinal reinforcement steels were practically located in the potential plastic hinge region of most bridge columns that were constructed before the 1992 seismic design provision of Roadway Bridge Design Specification in Korea. The objective of this research is to evaluate the seismic performance of shear-critical reinforced concrete(RC) bridge piers with poor detailing of the starter bars in the plastic hinge region, and to develop the enhancement scheme of their seismic capacity by retrofitting with fiber composites. Seven test specimens in the aspect ratio of 2.5 were made with three confinement ratios and two types of lap splices. Quasi-static test was conducted in a displacement-controlled test mode. A significant reduction of displacement ductility ratios were observed for test columns with lap splices of longitudinal steels.