• Title/Summary/Keyword: longitudinal reinforcement

Search Result 445, Processing Time 0.029 seconds

Crack Damages in Exterior Wall Structures of Korean High-Rise Apartment Buildings Based on Nonlinear Finite Element Analysis (비선형 유한요소해석 기반 국내 고층아파트 외벽구조의 균열손상 특성 분석)

  • Kim, Sung Hyun;Mo, Sang Yeong;Kim, Si Hyun;Choi, Kyoung Kyu;Kang, Su Min
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.47-57
    • /
    • 2024
  • Recently, in newly constructed apartment buildings, the exterior wall structures have been characterized by thinness, having various openings, and a significantly low reinforcement ratio. In this study, a nonlinear finite element analysis was performed to investigate the crack damage characteristics of the exterior wall structure. The limited analysis models for a 10-story exterior wall were constructed based on the prototype apartment building, and nonlinear static analysis (push-over analysis) was performed. Based on the finite element (FE) analysis model, the parametric study was conducted to investigate the effects of various design parameters on the strength and crack width of the exterior walls. As the parameters, the vertical reinforcement ratio and horizontal reinforcement ratio of the wall, as well as the uniformly distributed longitudinal reinforcement ratio and shear reinforcement ratio of the connection beam, were addressed. The analysis results showed that the strength and deformation capacity of the prototype exterior walls were limited by the failure of the connection beam prior to the flexural yielding of the walls. Thus, the increase of wall reinforcement limitedly affected the failure modes, peak strengths, and crack damages. On the other hand, when the reinforcement ratio of the connection beams was increased, the peak strength was increased due to the increase in the load-carrying capacity of the connection beams. Further, the crack damage index decreased as the reinforcement ratio of the connection beam increased. In particular, it was more effective to increase the uniformly distributed longitudinal reinforcement ratio in the connection beams to decrease the crack damage of the coupling beams, regardless of the type of the prototype exterior walls.

Finite element analysis of reinforced concrete spandrel beams under combined loading

  • Ibraheem, O.F.;Bakar, B.H. Abu;Johari, I.
    • Computers and Concrete
    • /
    • v.13 no.2
    • /
    • pp.291-308
    • /
    • 2014
  • A nonlinear, three-dimensional finite element analysis was conducted on six intermediate L-shaped spandrel beams using the "ANSYS Civil FEM" program. The beams were constructed and tested in the laboratory under eccentric concentrated load at mid-span to obtain a combined loading case: torsion, bending, and shear. The reinforcement case parameters were as follows: without reinforcement, with longitudinal reinforcement only, and reinforced with steel bars and stirrups. All beams were tested under two different combined loading conditions: T/V = 545 mm (high eccentricity) and T/V = 145 mm (low eccentricity). The failure of the plain beams was brittle, and the addition of longitudinal steel bars increased beam strength, particularly under low eccentricity. Transverse reinforcement significantly affected the strength at high eccentricities, that is, at high torque. A program can predict accurately the behavior of these beams under different reinforcement cases, as well as under different ratios of combined loadings. The ANSYS model accurately predicted the loads and deflections for various types of reinforcements in spandrel beams, and captured the critical crack regions of these beams.

Behavior of a tunnel face reinforced with longitudinal pipes - laboratory investigation (실내실험에 의한 수평보강재로 보강된 터널막장의 거동)

  • Yoo, Chung-Sik;Yang, Ki-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.2
    • /
    • pp.91-100
    • /
    • 2002
  • This paper presents the results of laboratory investigation on the deformation behavior of tunnel face reinforced with longitudinal pipes. A series of reduced-scale model tests was carried out to investigate the effect of reinforcement layout on the tunnel face axial displacement as well as the surface settlement. Among other things, the results of the model tests indicate that the axial displacement of tunnel face as well as the ground surface settlement can significantly be reduced by pre-reinforcing the tunnel face with longitudinal pipes, suggesting that the pre-reinforcing technique may effectively be used as a positive ground control method in the urban environments. Also illustrated is that the reinforcing effect is significantly influenced by the reinforcement layout. The implications of the findings from this study are discussed in a great detail.

  • PDF

Experimental Study on the Failure Behavior of RC Octagonal Hollow Section Columns with Aspect Ratio of 4.0 and Longitudinal Steel Ratio of 2.36 ~ 4.71% (형상비 4.0이고 축방향철근비 2.36 ~ 4.71%인 팔각형 중공단면 철근콘크리트 기둥의 파괴거동에 관한 실험적 연구)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.102-111
    • /
    • 2022
  • The aim of this study is to assess the seismic performance of octagonal hollow cross section reinforced concrete bridge pier, and to investigate the effect of longitudinal reinforcement ratios on the failure behavior. Four octagonal hollow section RC bridge columns of small scale model were tested under a quasi-static cyclically reversed horizontal load with constant axial load. The volumetric ratio of transverse spiral hoop of all specimens was maintained constant(0.206%), the ratios of longitudinal reinforcement were varied(2.36 ~ 4.71%). Failure behavior and seismic performance were investigated. Three specimens with the exception of lap spliced specimen showed flexure-shear failure at final stage. The test results with the exception of lap spliced specimen showed that the displacement ductility factor and accumulated energy dissipation decreased in inverse proportion to the ratio of longitudinal steel.

Stress-Strain Relationships of Concrete Confined by Spiral Reinforcement (나선근으로 횡보강된 콘크리트의 응력-변형도 관계)

  • 김진근;박찬규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.04a
    • /
    • pp.119-123
    • /
    • 1993
  • Axial load-strain relationships of confined concrete with spiral reinforcement were investigated. The main variables were compressive strength of concrete, spacing of hoop reinforcement, and specimen height of plain concrete. The program included tests of eleven confined specimens, and twelve plain specimens, but for all specimens no longitudinal reinforcement was provided. Load-strain curves of confined and plain concrete specimens are reporeted.

  • PDF

Effect of Reinforcement Type on Ultimate Strength of Tubular X-Joints (X형 관이음부의 보강방법에 따른 극한강도 해석)

  • 조현만;류현선;김정태
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.230-237
    • /
    • 2000
  • Tubular joints of jacket structures are usually reinforced using thicker can section, internally ring stiffeners, diaphragm, or externally gusset plates to increase load carry capacity. In this paper, the effect of reinforcement type and geometric parameters of stiffener on the ultimate strength of tubular X-joints subjected to brace compression have been studied numerically Three reinforcement methods were considered; (1)can reinforcement (2)internally ring stiffener (3)internally longitudinal diaphragm. The ANSYS software was used nonlinear strength analysis. It was found that there is significant strength enhancement for reinforced joints.

  • PDF

Numerical Analysis on Buckling of Longitudinal Bar in Reinforced Concrete Columns (철근콘크리트 기둥의 구조좌굴에 관한 수치해석)

  • 이리형;박재형;이용택
    • Computational Structural Engineering
    • /
    • v.8 no.2
    • /
    • pp.73-84
    • /
    • 1995
  • The study summarized in this paper is concerned with the buckling of longitudinal bars in reinforced concrete columns with numerical analysis method. The objectives of this study are (1) to investigate the stress transfer mechanism between concrete and reinforcement and (2) to propose a modeling equation. The results give an acceptable agreement between the proposed modeling equation and published computer packages as follows; (1) the proposed equation is a possible of strain softening of concrete and buckling of reinforcement. (2) the buckling of longitudinal bar is mainly influenced by spacing of hoop and location of the bar

  • PDF

Seismic Performance of RC Bridge Piers Retrofitted with Steel Bands (Steel Band로 보강된 철근콘크리트 교각의 내진성능)

  • Lee, Dae-Hyoung;Song, Hee-Won;Park, Chang-Kyu;Lee, Beom-Gi;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.97-100
    • /
    • 2005
  • It has been known that lab splices of the longitudinal reinforcement steel in bridge columns are not desirable for seismic performance, but it is sometimes unavoidable. Lap splices were usually be located in the plastic hinge region of most bridge columns that were constructed before the adoption of the seismic design provision of Korea Bridge Design Specification on 1992. This research is to evaluate the seismic performance of reinforced concrete bridge piers with lap splicing of longitudinal reinforcement in the plastic hinge region, and to develop the enhancement scheme of their seismic capacity by retrofitting with steel bands. It was observed that RC bridge specimens with lap-spliced longitudinal steels appeared to fail at low curvature and displacement ductility, but significant improvement was appeared in the ductility of RC specimens with steel bands retrofitted around the plastic hinge region.

  • PDF

Seismic Performance and Retrofit of Reinforced Concrete Bridge Piers with Spliced Longitudinal Steels (추철근 겹침이음된 철근콘크리트 교각의 보강에 의한 내진성능평가)

  • 정영수;이재형
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.179-186
    • /
    • 2001
  • It has been known that lap splicing in the longitudinal reinforcement of bridge columns is not desirable for seismic performance, but it is sometimes unavoidable. Lap splices were usually be located in the plastic hinge region of most bridge columns that were constructed before the adoption of the seismic design provision of Korea Bridge Design Specification on 1992. This research is to evacuate the seismic performance of reinforced concrete bridge piers with lap splicing of longitudinal reinforcement in the plastic hinge region, and to develop the enhancement scheme of their seismic capacity by retrofitting with glassfiber sheets and to develop appropriate limited ductility design concept in low or moderate seismicity region. Nine test specimens in the aspect ratio of 4.0 were made with three confinement ratios and three types of lap splicing. Quasi-static tests under three different axial load levees were conducted. It has been observed that displacement ductility ratios of test columns with lap splicing were significantly reduced.

  • PDF

Reinforcement Location of Plate Girders with Longitudinal Stiffeners (플레이트 거더의 수평보강재 보강 위치)

  • Son, Byung-Jik;Huh, Yong-Hak
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.82-89
    • /
    • 2009
  • Unlike concrete bridge, steel bridge resists external force by forming thin plate. Thus, because steel girder bridge has big slenderness ratio, buckling is a major design factor. Plate girder consists of flange and web plate. Because of economic views, web plate that resists shear forces is made by more thinner plate. Thus, web plate has much risk for buckling. The objective of this study is to analyze the buckling behaviors of plate girder and to present the proper reinforcement location of longitudinal stiffeners. Various parametric study according to the change of web height, transverse stiffeners and load condition are examined.