• 제목/요약/키워드: long-term monitoring system

검색결과 456건 처리시간 0.028초

교량의 상시감시 시스템 구축에 관한 연구 (The Study on Long-Term Monitoring System of Bridge)

  • 박승범;조광연;홍석주;최상필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.813-818
    • /
    • 1999
  • The construction of large scale civil and building structures which form the base of social economy has been grown greatly. As the increasing of aged and deteriorated structures, it is necessary to evaluate the safety of those structures. The deterioration, safety evaluation, repair and rehabilitation are important problems in the construction area that every country faces. This paper presents the general information on how to conduct a data analysis of long-term monitoring system and evaluate the characteristics of surveying methods.

  • PDF

철도교 상시계측시스템의 교정 및 교정상수 설정에 관한 연구 (Calibration of Health Monitoring System installed in the Railway Bridges)

  • 박준오;이준석;최일윤;민경주
    • 한국철도학회논문집
    • /
    • 제5권3호
    • /
    • pp.148-157
    • /
    • 2002
  • A health monitoring system becomes a useful tool to obtain information on long term behavior of the important railway structures such as very long span and special type bridges. The health monitoring system not only gives the direct measurement data of the railway bridges but also provides the basic data on the maintenance of the structures. Therefore, periodic calibrations of the health monitoring system will be a necessary step toward precise and accurate assessment of the railway bridges. In this study, the calibration and gauge factor readjustment process made for the health monitoring system installed in the railroad bridges is reviewed and some findings are explained in detail: specifically, the calibrators made for this purpose are illustrated and the regression processes of the calibration on long-term displacement using water level sensor, longitudinal displacement using LVDT sensor, instantaneous displacement using LVDT sensors and accelerometer are described in full length. Based on the regression results, it was found that the gauge factors need to be readjusted according to the regression equation but, since the deviation or shift is not serious so far, long-term observation on each sensor is also recommended. Future work will be concentrated on the long-term analysis of each sensor and on the database creation so that the assessment of the structures is possible.

철도구조물 상시계측시스템의 교정방안에 관한 연구 (A Study on the calibration of health monitoring system installed in rail infrastructures)

  • 이준석;최일윤;이현석;고동춘
    • 한국철도학회논문집
    • /
    • 제6권4호
    • /
    • pp.232-238
    • /
    • 2003
  • A health monitoring system becomes a very useful tool to obtain information on long term behavior of the important railway structures such as very long span and special type bridges. It can be also used to give a warning signal to the maintenance engineer when the structure shows abnormal behavior. However, due to long term use and temperature changes, the health monitoring system needs to be calibrated periodically. In this study, calibration and gauge factor readjustment process made for the health monitoring system installed in the railroad bridges and tunnel are reviewed and a few findings are updated. Future work will be concentrated on the long-term analysis of the measurement data and on the database structures so that the assessment of the structure is possible

장기처짐계측에 의한 노후교량의 유지관리에 관한 연구 (A Study on Maintenance of Deteriorated Bridge By Long-Term Displacement Monitoring)

  • 경갑수;이영일;이희현;박용진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권3호
    • /
    • pp.194-204
    • /
    • 1998
  • This study was performed to suggest the proper maintenance method for the deteriorated gerber type PC box girder bridge by using the long term displacement monitoring data. For this study, the monitoring system which can measure the long term displacement and the concrete surface temperature was designed and operated. From the measurement and structural analysis results, the cause of the permanent deformation which the bridge has already was estimated, and based on this result, the allowable permanent displacement value at the hinge was suggested. From this study, it was known that the long term monitoring system can be applied to the active maintenance of the deteriorated bridge and the suggested allowable permanent displacement could be used for the maintenance of the bridge.

  • PDF

선박엔진성능분석용 웹기반 장기모니터링시스템 구현 (Long-term Monitoring System for Ship's Engine Performance Analysis Based on the Web)

  • 권혁주;양현숙;김민권;이성근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.483-488
    • /
    • 2015
  • 본 논문에서는 엔진유지관리 개선을 위해 Web 기반 선박엔진성능분석용 장기모니터링시스템을 구현하고자 한다. 이 시스템은 시뮬레이터, 다채널 A/D 변환기가 내장된 감시모듈, 모니터링 컴퓨터, 네트워크저장기(NAS), RS485 및 무선인터넷 통신시스템으로 구성된다. 기존 제품은 각 엔진마다 압력센서를 설치하고 이를 감시모듈에서 실시간으로 계측한 후 통신에 의해 현장 제어실 PC나 Web 상에서 모니터링이 가능하지만 많은 샘플링 압력데이터 용량으로 인해 통신전송속도가 느려지고, 장기모니터링에 오류가 발생할 수 있다. 이와 같은 문제점을 개선하기 위하여 본 논문에서는 각 실린더별 압력센서에서 받은 원본 압력데이터는 NAS에 저장하고, 원본 압력데이터를 구간별 다운샘플링을 하여 제어실에서 장기모니터링하고, Web에서의 장기모니터링을 위하여 다운샘플 데이터를 무선전송 한다. 제안한 방식에서는 전송량을 1/10로 하였으므로 작은 용량을 가진 메모리를 사용할 수 있고, 빠른 통신속도를 유지할 수 있어 통신비용이 절감되며, 화면전체에 약 30일간의 장기모니터링이 가능하여 엔진의 유지관리에 큰 기여를 할 수 있을 것으로 사료된다.

수질오염총량관리를 위한 4대강수계 장기유황곡선 작성방안 (Development of Long Term Flow Duration Curves in 4 River Basins for the Management of Total Maximum Daily Loads)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.343-353
    • /
    • 2013
  • Flow duration curve (FDC) can be developed by linking the daily flow data of stream flow monitoring network to 8-day interval flow data of the unit watersheds for the management of Total Maximum Daily Loads. This study investigated the applicable method for the development of long term FDC with the selection of the stream flow reference sites, and suggested the development of the FDC in 4 river basins. Out of 142 unit watersheds in 4 river basins, 107 unit watersheds were shown to estimate daily flow data for the unit watersheds from 2006 to 2010. Short term FDC could be developed in 64 unit watersheds (45%) and long term FDC in 43 unit watersheds (30%), while other 35 unit watersheds (25%) were revealed to have difficulties in the development of FDC itself. Limits in the development of the long term FDC includes no stream monitoring sites in certain unit watersheds, short duration of stream flow data set and missing data by abnormal water level measurements on the stream flow monitoring sites. To improve these limits, it is necessary to install new monitoring sites in the required areas, to keep up continuous monitoring and make normal water level observations on the stream flow monitoring sites, and to build up a special management system to enhance data reliability. The development of long term FDC for the unit watersheds can be established appropriately with the normal and durable measurement on the selected reference sites in the stream flow monitoring network.

사례 연구: 녹거노인 일상 활동 모니터링 시스템의 실제 주택에서의 장기간 실험 (Case Study: Long-term Experiments on a Daily Activity Monitoring System for an Elderly Living Alone)

  • 이선우;옥대윤;정필환;김점근
    • 제어로봇시스템학회논문지
    • /
    • 제18권8호
    • /
    • pp.738-743
    • /
    • 2012
  • This paper describes analysis of long-term experiments on a monitoring system to assess the daily activities of the elderly who live alone. The developed system is composed of an in-house sensing system and a server system. The in-house sensing system installed in their own houses is a typical wireless sensor network system including three kinds of wireless sensors. The server system has a database server and an assessment server. We have installed the system into an elderly house, collected data during over two years continuously, then analyze the data. From the analysis, we could measure the energy consumption profile of three kinds of sensor nodes. The experiment shows all kinds of nodes can operate over one year with two AA-size alkaline batteries. Using a measure of reliability of the monitoring system called 'deadzone', the system has showed the failure operation for 842 hours (4.66 %) during over 18,000 hours total operation period.

천곡동굴의 수질환경 장기 모니터링 (A Long-term Monitoring of Water Quality at Chongok Cave)

  • 전병희
    • 한국지반환경공학회 논문집
    • /
    • 제14권9호
    • /
    • pp.13-19
    • /
    • 2013
  • 천곡동굴은 동해시에 자리잡고 있는 석회암동굴로서 많은 돌리네를 가지고 있어 관광적 가치와 교육적 가치가 매우 높다. 하지만 천곡동굴은 시가지에 위치하고 있어 접근이 용이한 반면 하수의 유입 등에 의해 환경적 영향을 받을 가능성이 매우 크다. 본 연구에서는 천곡동굴의 수질환경을 장기 모니터링하여 생태계의 영향을 조사하고, 향후 장기 모니터링을 위한 인자를 선정하였다. 그 결과 천곡동굴 내 지하수의 수온은 $14^{\circ}C$, 용존 산소량은 10mg/L 이상, pH는 7-8의 범위에서 안정되게 유지되고 있어, 수생태계에 부정적 영향을 주는 수질적 요소는 없는 것으로 판단되었다. 관람객의 안전을 확보하기 위한 강우기준으로서 일강우로서 60mm/d가 적절하며 향후 장기 모니터링을 위해서 전기전도도를 주된 인자로 이용하고 pH와 탁도를 보조적으로 활용하는 것이 적절하며, 계절적 변화 등을 ORP를 이용하여 모니터링하는 것이 적절하다고 판단되었다.

국내 교량 계측시스템 현황 파악 및 문제점 분석 (The state of the art on bridge monitoring system in Korea)

  • 박기태;이우상;주봉철;황윤국
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.465-468
    • /
    • 2008
  • The long term bridge monitoring system in Korea was installed in 1995 at first, and many bridges has been maintained by long term monitoring system. Recently, reliability of data and cost effectiveness has been increased by advanced sensor technology, measuring equipment. However, considering several reference and data on bridge monitoring systems in Korea, various problems of bridge monitoring systems can be found. Therefore, in this study, the state of the art on bridge monitoring systems in Korea were investigated and various problems and solutions for these problems were suggested.

  • PDF

Design of a MEMS sensor array for dam subsidence monitoring based on dual-sensor cooperative measurements

  • Tao, Tao;Yang, Jianfeng;Wei, Wei;Wozniak, Marcin;Scherer, Rafal;Damasevicius, Robertas
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권10호
    • /
    • pp.3554-3570
    • /
    • 2021
  • With the rapid development of the Chinese water project, the safety monitoring of dams is urgently needed. Many drawbacks exist in dams, such as high monitoring costs, a limited equipment service life, long-term monitoring difficulties. MEMS sensors have the advantages of low cost, high precision, easy installation, and simplicity, so they have broad application prospects in engineering measurements. This paper designs intelligent monitoring based on the collaborative measurement of dual MEMS sensors. The system first determines the endpoint coordinates of the sensor array by the coordinate transformation relationship in the monitoring system and then obtains the dam settlement according to the endpoint coordinates. Next, this paper proposes a dual-MEMS sensor collaborative measurement algorithm that builds a mathematical model of the dual-sensor measurement. The monitoring system realizes mutual compensation between sensor measurement data by calculating the motion constraint matrix between the two sensors. Compared with the single-sensor measurement, the dual-sensor measurement algorithm is more accurate and can improve the reliability of long-term monitoring data. Finally, the experimental results show that the dam subsidence monitoring system proposed in this paper fully meets the engineering monitoring accuracy needs, and the dual-sensor collaborative measurement system is more stable than the single-sensor monitoring system.