• Title/Summary/Keyword: long-range inspection

Search Result 75, Processing Time 0.024 seconds

A Study for Flaw Detection of 3/4″ Pipe by Using Guided Wave (유도초음파를 이용한 3/4″ 배관 결함 검출 연구)

  • Chung, Woo Geun;Kim, Jin-Hoi;Cheon, Keun Young
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.40-45
    • /
    • 2019
  • Unlike the welded pipes in the primary system of light water nuclear power plants being periodically inspected with in-Service inspection program, relatively small pipes with the outer diameter less than 2 inch have not been regularly inspected to date. However, after several failure reports on the occurrence of critical crack-like defects in small pipes, inspection for the small pipes has been more demanded because it could cause the provisional outage of nuclear power plants. Nevertheless, there's no particular method to examine the small pipes having access limitations for inspection due to various reasons; inaccessible area, excessive radiation exposure, hazardous surrounding, and etc. This study is to develop a reliable inspection technique using torsional and flexural modes of guided wave to detect defects that could occur in inaccessible area. The attribute of guided wave that can travel a long distance enables to inspect even isolated range of the pipe from accessible location. This paper presents a case study of the evaluation test on 3/4" small-bore pipes with guide wave method. The test result demonstrates the crack signal behavior and assures possibility to detect the crack signal in a flexural mode, which is clearly distinguishable from the symmetric structure signal in a torsional mode.

A Study on the Preparation of Inspection Standard for Front Collision Protection System for Vehicles (승용차 전방충돌보호 시스템 검사기준 마련 연구)

  • Park, Jiyang;Gwon, Yeongmun;Choi, Sookwang;Lee, Hosang;Kim, Yongdal;Yeo, Unseok;Jeong, Jaehwan;Kim, Jinyong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.2
    • /
    • pp.24-29
    • /
    • 2021
  • In order to prevent automobile accidents internationally, advanced safety devices are actively being developed. Among them, Auto Emergency Brake (AEB) function and Forward Collision Warning (FCW), which are used to prevent or reduce frontal collision, have been studied for a long time, and are being researched by various manufacturers to develop better performance. In fact, in the case of large vehicles, it is mandatory for AEB to be installed in Korea. Accordingly, a variety of Vehicles equipped with AEB and FCW are coming out, and inspection of these mounting devices is a necessary system in the future. This study confirms how AEB and FCW are currently assessed in regulation and the New Car Assesment Program (NCAP), This is a basic study of the matters to be considered in preparing AEB and FCW inspection standard by checking the performance of vehicles equipped with forward collision protection and identifying the vehicle's sensitivity, range and speed of radar sensors, and target vehicles based on CAN communication data.

Optimal Design and Control of xy${\theta}$ Fine Stage in Lithography System (리소그라피 장비에서 xy${\theta}$미세구동기의 최적 설계 및 제어)

  • 김동민;김기현;이성규;권대갑
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.163-170
    • /
    • 2002
  • The quality of a precision product, in general, relies on the accuracy and precision of its manufacturing and inspection process. In many cases, the level of precision in the manufacturing and inspection system is also dependent on the positioning capability of tool with respect to the work piece in the process. Recently the positioning accuracy level has reached to the level of submicron and long range of motion is required. For example, for 1 GDARM lithography, 20nm accuracy and 300mm stroke needs. This paper refers to the lithography stage especially to fine stage. In this study, for long stroke and high accuracy, the dual servo system is proposed. For the coarse actuator, LDM (Linear DC Motor) is used and for fine one VCM is used. In this study, we propose the new structure of VCM for the fine actuator. It is 3 axis precision positioning stage for an aligner system. After we perform the optimal design of the stage to obtain the maximum force, which is related to the acceleration of the stage to accomplish throughput of product. And we controlled this fine stage with TDC. So we obtained 50nm resolution. So later more works will be done to obtain better accuracy.

Variable Angle Beam Guided Wave Probe Design for Tubing Based on Solid Mechanics

  • Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.594-604
    • /
    • 2003
  • A State-of-art methodologies on implementing conventional piezoelectric and flexible PVDF elements for generating ultrasonic guided waves in a tubing are presented. Comb transducers with PVDF can be efficiently applied to selectively excite a guided wave mode by wrapping around any size pipe while a conventional immersion type piezo-elements can be also possibly used with a modification of transducer fabrication. Technical comparisons between the use of angle beam probe and comb one will be also discussed in detail. The presented technique can be easily applied to NDE for a long range inspection of tubular structures.

Flaw Detection of Petrochemical Pipes using Torsional Waves (비틀림파를 이용한 석유화학 파이프의 결함탐지)

  • Park, K.J.;Kang, W.S.;Kang, D.J.
    • Journal of Power System Engineering
    • /
    • v.14 no.3
    • /
    • pp.46-51
    • /
    • 2010
  • A torsional guided wave was applied to detect a defect in petrochemical pipes. Phase and group velocity dispersion curves for the longitudinal and torsional modes of the inspected pipe were presented for the theoretical analysis. It was found through mode shape analysis that there was mode conversion when torsional wave is incident at an asymmetric defect. An artificial notch was fabricated in the pipe and the detectability was examined from the distance 2m of the end of the pipe by using magnetostrictive sensors. The relativities between the amplitude of the reflected signal and the size of the defect was examined. It was shown that the T(0,1) mode could be used for the long range inspection for the petrochemical pipes.

An Experimental Study on the Neutralization of High-Flowable Concrete (고유동콘크리트의 중성화에 관한 실험적 연구)

  • Jeon, Hyun-Kyu;Lim, Jin-Kyu;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.3
    • /
    • pp.177-185
    • /
    • 1999
  • In this study, study about fly ash and blast-furnace slag used as substitutive materials for cement, and the influence on the neutralization of high flow concrete durability with these substitutive materials was performed and analyzed. The results are as follows 1) Aggregate segregation was partially improved with the progress of the admixture input at the mix proportion above slump flow 65 cm 2) Compressive strength with the progress of the increasement of fly ash input was decreased in early age, but decrease range was improved in long term age. Also, in case of blast-furnace, similar or improved compressive strength was appeared. 3) The neutralization depth with fly ash input was noticeably increased. But blast-furnace slag was effective to prevent. 4) In this experiment, high powder content was advantageously affected on preventive effect of the neutralization, and the relationship between the compressive strength and the neutralization depth was inversely proportional.

  • PDF

X-RAY Inspection for PCB/SMT & Electronics Components Latest Development

  • Maur Friendhelm W.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.02a
    • /
    • pp.17-25
    • /
    • 2004
  • During the past few years, advances have been made in both in X-ray tube and detector technologies. The field of microfocus radioscopy has been established as an important testing process and has expanded into many new industrial applications that require quality control or process optimization. The first nanofocus and multifocus X-ray systems have become available with a focal spot of .5 micron. In the existing range of microfocus X-ray tubes, further improvements have been achieved as well, such as increased long term stability of intensity position constancy. Software, image processing and manipulation techniques have all progressed as well, allowing X-ray to become a formidable non-destructive inspection method for manufacturers in virtually every industry, especially those involved with Electronic Packaging and SMT.

  • PDF

Evaluation on Expectation of Deflection of Floor Damping Materials Subjected to Long-Term Load (장기하중을 받는 바닥완충재의 처짐 예측 평가)

  • Kim, Jung-Min;Hong, Yoon-Ki;Kim, Jin-Koo;Lee, Jung-Yoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.19-26
    • /
    • 2016
  • Floor damping materials used in floating floor system to diminish the floor noise have been made with low density and dynamic stiffness. Owing to this low density and dynamic stiffness, the deflection in these materials under long-term loading and cracking of the floor finishing mortar in the floating floor system may occur. This paper presents the results of long-term loading effects on the deflection of different types of floor damping materials. The experimental program involved the long-term loading tests for 490 days loading period on sixteen specimens. Specimens were classified as DM1(Damping Materials) to DM8, depending upon the four main parameters; types, bottom shapes and densities of floor damping materials and amount of loading. Results indicated that the long-term deflection of all specimens of damping materials remained unchanged after 200 days at all loading amounts, except the specimens made up of Polystrene, in which long-term deflection remained unchanged after 160 days at 250 N load and 100 days 500 N load. In this paper, two types of correlation expressions were shown in the deflection range prior to the range where deflection remained constant; two analyses by ISO 20392 and linear regression. In comparison of two analyses and experimental results on the difference of deflection of 16 specimens, the difference of deflection was below 0.4 mm in those analyses in case of that total deflection was below 10 mm. Restrictively, it was judged that the analysis for the deflection of specimens made up of Polystrene is more appropriate using ISO 20392.

Effect of Moisture Conditions in Soils on Mode Attenuation of Guided Waves in Buried Pipes (지반의 수분 상태에 따른 매립 배관에서의 유도초음파 모드 감쇠 변화)

  • Lee, Ju-Won;Shin, Sung-Woo;Na, Won-Bae;Kim, Young-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.42-47
    • /
    • 2010
  • Recently, many techniques have been developed for the inspection of pipelines using guided waves. However, few researches have been made on the application of those techniques for buried underground pipes. Guided wave motions in the buried pipes are somewhat different from those of on-ground pipes which have traction-free (air) boundary condition on outer pipe walls and thus are strongly affected by the mechanical property of the surrounding soils. Therefore, it should be investigated the effect of soil properties on the guided wave behavior in buried pipe. On the other hand, the mechanical property of soil is largely depending on its moisture conditions nevertheless of other influential factors such as void ratio. In this study, the effect of moisture conditions in soils on mode attenuation of guided waves in the buried pipe is investigated. To this end, numerical study is performed to characterize mode attenuation behavior in buried pipes and the effective mode which is suitable for long range inspection is identified.

Evaluation of Emission Reduction Program for In-use Diesel Vehicles Using PM10 Concentrations of Road-side and Background Monitoring Network (도로변 및 배경농도 측정망 PM10 자료를 이용한 노후 운행경유차 배출가스 저감사업 효과 해석)

  • Kim, Cheol-Hee;Jo, Hyun-Young;Lee, Song-Weon;Oh, Chang-Seok
    • Journal of Environmental Science International
    • /
    • v.20 no.12
    • /
    • pp.1585-1598
    • /
    • 2011
  • Emission reduction program for in-use diesel vehicles (ERPDV) has been enacted since 2004 over the Seoul metropolitan area, and diesel emission reduction is forced to fulfill this regulation. This study was performed to evaluate the ERPDV using $PM_{10}$ concentrations of both road-side monitoring and national background network during the period of 2004-2010. In order to assess the pure road emission, we first eliminated the long range transport effect by deducting the trend of annual national background concentrations from the road-side $PM_{10}$ concentrations, and then analyzed the time series of the resultant $PM_{10}$ concentrations over Seoul metropolitan area. The annual rates of variations of road-side $PM_{10}$ with the deduction of trend of background level show -3.2, +0.4, and -2.4 ${\mu}g/m^3$/year, in Seoul, Incheon, and Gyonggi province, respectively. There are steadily decreasing trend in Seoul with all of statistic parameters such as mean, mediam, 5%ile, 10%ile, 25%ile, 75%ile, 90%ile, and 95%ile concentrations. Incheon shows some fluctuations with positive with no significant trend, and Gyonggi province shows overall decreasing but not consistent. Student-t test shows 95% significant level of ERPDV effect in Seoul, but there exists no significant level greater than 90% in both Incheon, and Kyonggi province. Total annual averaged trend over the whole Seoul metropolitan area is estimated to lie in approximately $-2.9{\mu}g/m^3$/year in this study, implying the intimate involvement of ERPDV to a large extent. This is also suggesting that the further research cost-effectiveness of ERPDV with consideration of the long range transport process would be needed over the Seoul metropolitan area.