• 제목/요약/키워드: long tunnel fire

검색결과 62건 처리시간 0.024초

CFD code를 이용한 철도터널 화재 위험도 평가 (The Quantitative Risk Assessment for Railroad-tunnel Fire Incidents by using CFD code)

  • 김학범;이덕희;장용준;정우성
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.169-172
    • /
    • 2011
  • Recently, railroad long tunnels are increasing and growing longer due to topological feathers like a lot of mountain in Korea. But fire disaster of a long tunnel cause many people to injury and death. For that reason, at the early design stage of a long tunnel, risk assessment and mitigation measure of risk for satisfying tunnel safety are required. According to the railroad facility safety standard (Korean MLTM Announcement No. 2006-395), risk assessment for railroad-tunnel fire should be performed when design stage. Therefore, various methods of risk assessment for tunnel fire have been studied and applied. In the paper, QRA(Quantitative Risk Analysis) for fire risk assessment by using CFD code is presented and the usefulness of CFD is discussed.

  • PDF

Hard rock TBM project in Eastern Korea

  • Jee, Warren W.
    • 한국암반공학회:학술대회논문집
    • /
    • 한국암반공학회 2008년도 국제학술회의
    • /
    • pp.33-41
    • /
    • 2008
  • The longest tunnel has been halted at Daekwanryung by the failure of the host country of the Winter Olympiad in 2014, but modern High-Power TBM will come to Korea to excavate these long tunnels to establish the better horizontal connection between the western and eastern countries to improve the strong powerful logistic strategy of Korean peninsula. Train operation provides a key function of air movements in a long underground tunnel, and heat generation from transit vehicles may account of the most heat release to the ventilation and emergency systems. This paper indicates the optimal fire suppress services and safety provision for the long railway tunnel which is designed twin tunnel with length 22km in Gangwon province of Korea. The design of the fire-fighting systems and emergency were prepared by the operation of the famous long-railway tunnels as well as the severe lessons from the real fires in domestic and overseas experiences. Designers should concentrate the optimal solution for passenger's safety at the emergency state when tunnel fires, train crush accidents, derailment, and etc. The optimal fire-extinguishing facilities for long railway tunnels are presented for better safety of the comfortable operation in this hard rock tunnel of eastern mountains side of Korea. Since year 1900, hard rock tunnel construction has been launched for railway tunnels in Korea, tunnels have been built for various purposes not only for infrastructure tunnels including roadway, railway, subway, and but also for water and power supply, for deposit food, waste, and oils etc. Most favorable railway tunnel system was discussed in details; twin tunnels, distance of cross passage, ventilation systems, for the comfortable train operations in the future.

  • PDF

장대터널용 소방차량의 운용에 관한 연구 (The study on the operation of fire fighting vehicle for a long railway tunnel)

  • 권태순;박원희
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.516-521
    • /
    • 2016
  • 본 연구에서는 장대터널의 철도차량 화재사고 진압을 위한 소방차량 운용 시 고려사항을 분석 및 검토하였다. 최근들어 터널연장 10 km 이상의 긴 장대터널 시공사례가 늘고 있으며 경부선의 금정터널(연장 20.3 km)을 시작으로 영동선의 솔안터널(연장 16.7 km) 및 2016년 하반기 개통 예정인 수서고속선의 율현터널(연장 50.3 km)까지 점점 터널의 길이가 증가하는 추세이다. 이에 따라 터널 내에서 철도차량 내 대형화재사고 발생으로 긴급정차 시에 승객의 피난시간이 길어지는데 반해 소방인력의 접근은 더욱 어려워져서 큰 인명피해의 발생이 우려된다. 이에 해외 선진국에서는 철도선로 주행이 가능한 특수소방차량을 개발 및 도입하여 운용 중에 있다. 따라서 국내에서도 기존 도로전용 소방차량이 아닌 철도터널 내에서 운행이 가능한 특수소방차량 도입을 통한 대응체계 구축이 요구된다. 상기 목적으로 본 연구에서는 철도터널의 주요 환경과 철도차량 내 화재발생에 따른 터널 내 열환경 변화를 분석하였다. 또한, 분석결과를 개발 중인 장대터널용 소방차량의 주요 사양과 연계하여 국내 장대철도터널에서 소방차량 운용 시 주요 고려사항을 제안하였다.

장대 교통터널의 피난연락갱 설치 간격에 관한 실험적 연구 (Experimental Study on the Interval of Emergency Exits in Long Traffic Tunnels)

  • 유용호;윤성욱;김진;윤찬훈
    • 터널과지하공간
    • /
    • 제15권1호
    • /
    • pp.61-70
    • /
    • 2005
  • 본 연구에서는 장대 터널 화재시 연기의 거동 특성 파악과 피난연락갱의 설치간격을 결정하기 위하여 축소 모형실험을 실시하여 그 결과를 분석하였다. Froude 상사를 기본으로 1/50로 축소하여 20 m의 모형 터널을 제작하여 실험하였다. 터널 내 20 MW의 화재가 발생 하였을 경우 CO의 전파 속도와 거리와의 관계를 이용하여 피난연락갱의 위치를 검토한 결과, 승객들의 피난시간은 6분이 적절하나 화재시 승객들의 심리적 상태를 고려하여 1분여의 지체시간을 생각하면 실제의 피난시간은 5분 정도가 될 것이므로 최대 간격 250m로 대인용 피난연락갱을 설치하는 것이 바람직할 것으로 판단되었다.

터널의 기하학적 형태 및 캐노피 설치가 터널 환기 및 화재 확산에 미치는 영향 분석 (The Effects of Tunnel Geometrical Characteristics and Canopy Installation on the Ventilation and Fire Propagation)

  • 이창우;서기윤;김정욱
    • 한국터널지하공간학회 논문집
    • /
    • 제8권4호
    • /
    • pp.325-334
    • /
    • 2006
  • 시계조절이나 설해방지 목적으로 설치되는 캐노피 구간 내에서의 기류유동특성의 이해는 정상환기 뿐만 아니라 비상시 대처방안 강구를 위한 요건이다. 또한 터널 방재시스템 설계를 위하여서는 종단구배, 평면선형, 단면크기 및 형태 등과 같은 터널의 다양한 특성이 화재확산에 미치는 영향에 대한 정량적인 이해가 필요하다. 본 연구에서는 국내도로터널의 전형적인 특성을 적용한 터널에 캐노피가 된 경우와 종단 및 선형구배, 단면적 및 형태, 곡선구간이 환기 및 화재확산에 미치는 영향을 CFD분석함을 목적으로 하였다. 분석결과 145m길이의 캐노피인 경우 50%정도의 개구율이 기류유동 패턴 및 환기효과면에서 가장 바람직하였다. 1.8km 터널내에서 20MW 화재발생시 종단구배는 풍속분포와 화재연 확산에 큰 영향을 미치며 제트팬$({\varnothing}1250)$ 4대를 가동한 경우 화재발생 후 5분 경과시 하류 40m지점 부근에서의 화재연 농도는 +2% 구배에서는 13% 감소, -2% 구배의 경우에는 20%정도 증가하며 또한 backlayering거리가 45m정도에 달한다. 직사각형 단면터널의 경우, 화재연 농도 및 풍속분포는 말굽형 터널과 비교하여 현저한 차이가 관찰되지 않는다. 3차선 터널에서는 이들 변수는 모두 감소하며 100초 경과시 50m 정도의 backlayering을 보이며 이후 서서히 감소한다. 곡선터널인 경우는 화재연의 확산이 느리며 100초 경과시 50m에 달하던 backlayering현상은 급격히 사라진다.

터널 내 화재발생시 구난역 내의 연기 거동에 미치는 설계된 환기 영향에 대한 실험적 연구 (Experimental Study on the Designed Ventilation Effect on the Smoke Movement at Rescue Station fire in Railway Tunnel)

  • 김동운;이성혁;유홍선;윤성욱
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.163-167
    • /
    • 2008
  • In this study, the 1/35 reduced-scale model experiment were conducted to investigate designed ventilation effect on the smoke movement at rescue station fire in railway tunnel. A model tunnel with 2 mm thick, 10 m long, 0.19 m high and 0.26 m was made by using Froude number scaling law. The cross-passages installing escape door at the center were connected between incident tunnel and rescue tunnel. The n-heptane pool fires with heat release rate 698.97W were used as fire source. The fire source was located at the center and portal of incident tunnel as worst case. A operating ventilation system extracted smoke amount of 0.015 cms(cubic meters per second). The smoke temperature and CO gas concentration in cross-passage were measured to verify designed ventilation system. The result showed that, at center fire case without ventilation, smoke did not propagate to rescues station. In portal fire case, smoke spreaded to rescues station without ventilation. But smoke did not propagated to rescues station with designed ventilation.

  • PDF

소방대의 현장접근성 강화를 위한 설비의 개선방안 (The Way for improvement of facility to strengthen accessibility of the site for fire department)

  • 오택흠;성재만;박찬석
    • 대한안전경영과학회지
    • /
    • 제14권3호
    • /
    • pp.67-75
    • /
    • 2012
  • Because recently(July 14, 2011) fire occurred in the engine room of a moving taxi under Namsan Tunnel 1, 51 vehicles' driver and more than 250 passengers in the road tunnel were urgently evacuated with abandoned vehicles. Vehicle fires in Namsan Tunnel that day, Sufferers struggled to escape quickly difficult to escape the two-way by abandoned vehicles on the road and to fear many casualties by using vehicle fuel and combustible interior and the driver who is ignorant of vehicle accident continuous entered in the road tunnel had accessibility the site of fire department was more difficult. In this study, It is to investigate structure and basic materials, such as fire extinguish equipment and facilities for damage prevention and to analyze the problems and to plan improvement method of fire extinguish equipment, facilities for damage prevention and transportation facilities(Large traffic signs, Breaker, etc.) on the Namsan Tunnel that in the long-term plan is prepared to strengthen for accessibility of the site of fire department in case of Vehicle's fire.

제트 팬 설치 위치에 따른 직선터널 내의 제연해석 (Analysis of Smoke Control According to Jet Fan Location in Straight Long Tunnel)

  • 변주석;임효재;강신형;이진호
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.662-668
    • /
    • 2007
  • In this study, jet fans are installed with 4 cases in the straight long tunnel; inlet-side setup, middle-side setup, outlet-side setup, and dispersion setup. A bus is selected as fired car, of which fire size is 20MW. And fired car locates at 100m, 700m, 1500m position from tunnel inlet, respectively. FLUENT, commercial finite-volume code, is used to analyze the performance. The velocity profile, $CO_2$ concentration, temperature distribution are examined for analysis. Performance of smoke control is compared by the backlayering length. Consequently, inlet-side setup of jet fans is a little more efficient than other cases considering the fire occurrence frequency in tunnel.

철도장대터널의 대피통로 최적간격에 관한 연구 (A Study of Proper Space between the Escape Tunnels in the Long Railway Tunnel)

  • 김동기;박병은;나상주;박종관
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.880-885
    • /
    • 2004
  • When a fire takes place, the escape tunnel which could prevent passengers and the crew from disasters would be most important facility among railway tunnel facilities for prevention of disaster. A shorter space between the escape tunnels is much better for safety because of short escape time. The establishment of short space escape tunnels(driftways) in the single track parallel tunnel is much easier. The establishment of long space escape tunnels(inclined shafts, vertical shafts) in the double track is much more advantageous economically. We, therefore, compared the movement time of smog originated from fire with the escape time of the crew and passengers for setting up the best space between the escape tunnels in the double track tunnel. We could calculate the best space between the escape tunnels in the double track tunnel properly by computer simulation.

  • PDF

터널용 에어커튼 시스템의 내열 및 제연 성능 평가 연구 (The study on performance evaluation of heat resistance and smoke control system using air-curtain system in tunnel)

  • 박병직;신현준;유용호;박진욱;김양균;김휘성
    • 한국터널지하공간학회 논문집
    • /
    • 제20권4호
    • /
    • pp.743-755
    • /
    • 2018
  • 터널은 지하공간과 유사한 반밀폐 형태로서 화재 발생 시 연기가 빨리 차오르고 외부로 연기가 천천히 빠져나가는 구조이다. 이에 따라 교통사고로 인한 화재 발생 시 사고차량 뒤에 차량이 연속으로 정차되어 차량을 이용한 피난이 어려우며, 화재 현장에 소방차 진입이 어렵기 때문에 소화하기가 매우 어렵다. 따라서 국내외적으로 터널 방재등급을 설정하고 이에 맞는 방재시설을 설치하고 운영하고 있다. 우리나라 도로터널은 1 km 미만의 터널의 80.0%를 차지하고 있으며, 1 km 미만의 터널은 방재등급 3등급으로서 제연시설을 설치하지 않아도 된다. 본 연구에서는 내열시로코 팬을 이용한 에어커튼 시스템을 1 km 미만 터널에 제연설비로 활용하기 위해서 실물화재실험을 통하여 성능평가를 수행하였다. 이에 따라, $250^{\circ}C$의 온도에서 60분 이상 작동하는지 내열시험을 통해서 확인하였으며, 실물화재실험을 수행하여 에어커튼 내부(터널 화재방향)에서는 온도 및 이산화탄소 농도가 급격히 상승하였지만, 에어커튼 외부(터널 외기방향)에서는 초기의 상태를 유지하고 있는 것을 확인하였다.