Application of AE Techniques for Detecting Wire Fracture in the PSC Railway Bridges (철도 PSC교량의 텐던 파단 감지를 위한 AE방법의 적용)

  • Choi Min-Seok;Youn Seok-Goo;Kim Eun-Keum
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1223-1228
    • /
    • 2005
  • A lot of PSC railway bridges have been constructed in countries and, they are considered as cost-effective and less maintenance-demanded structures. However, recently several collapse of PSC bridges happened in Europe show that PSC bridges have some serious maintenance problems related to tendon corrosion and wire fractures. Furthermore, any reliable NDT method is not presented until recently. In this paper, AE techniques are investigated for detection of wire fractures in PSC beam. Using long-term monitoring AE techniques, two acoustic signals of wire fractures in a PSC beam are obtained. These data are compared to other noise signals. Based on the test results, the characteristics of the AE signals are classified and wire fracture signals are figured out among the other AE signals. As a result, AE techniques are certainly exposed to tendon fracture sound, and application of AE techniques are better than any other non-destructive method.

  • PDF

A Study on The Missile Service Life Extension Plan (유도탄 수명 연장 방안 고찰)

  • Ryoo, Baekneung;Kim, Baegyong;Yoo, Jichang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.163-167
    • /
    • 2017
  • The service life extension of the missile can reduce the replacement cost of the missile, maintain the combat power, and consist of the lifetime assessment of the shelf-life(energetic) items, the maintenance of the missile and upgrade of the related components. This technology should be developed together with the missile system and advanced sustainedly. It is a converging technology that combines various fields of expertise and long-term experiences and databases.

  • PDF

The Design and Implementation of Manhole Management System Using Wireless Communication (무선 통신을 이용한 맨홀 관리시스템 설계 및 구현)

  • Lee, Sangyoon;Lee, Yougkwon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.2
    • /
    • pp.53-61
    • /
    • 2017
  • How to manage manhole is to estimate the part without observation and maintain the sewer. To get the information about current flow rate, visiting and measuring specific manhole is positively necessary. Also, there are some problems that accurate measurement of flow rate is difficult and obtaining the information about real-time whole flow rate is impossible. This thesis will easily grasp the accurate location and type of manhole to solve the problems, and provide the manhole system conveying information through direct radio communication with a manhole cover to renewal information of manhole properly. Besides, it intends to save the information about management of waterworks, maintenance of facilities, data for flow rate, and structure of manhole. Using these, it is supposed to offer how to handle manhole. Thus, this thesis delivers the information to manhole and into central servers directly without wire and provides the system and management method for effective maintenance of manhole.

An Experimental Study on the Neutralization of High-Flowable Concrete (고유동콘크리트의 중성화에 관한 실험적 연구)

  • Jeon, Hyun-Kyu;Lim, Jin-Kyu;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.3
    • /
    • pp.177-185
    • /
    • 1999
  • In this study, study about fly ash and blast-furnace slag used as substitutive materials for cement, and the influence on the neutralization of high flow concrete durability with these substitutive materials was performed and analyzed. The results are as follows 1) Aggregate segregation was partially improved with the progress of the admixture input at the mix proportion above slump flow 65 cm 2) Compressive strength with the progress of the increasement of fly ash input was decreased in early age, but decrease range was improved in long term age. Also, in case of blast-furnace, similar or improved compressive strength was appeared. 3) The neutralization depth with fly ash input was noticeably increased. But blast-furnace slag was effective to prevent. 4) In this experiment, high powder content was advantageously affected on preventive effect of the neutralization, and the relationship between the compressive strength and the neutralization depth was inversely proportional.

  • PDF

On the Improvement of Facility to Performance Evaluation and Security of Safety through the Application of AHP Method in Railroad Signal Control System (철도 신호제어 시스템의 AHP 기법 적용을 통한 성능평가 대상설비 항목 개선 및 안전성 확보에 관한 연구)

  • Hwang, Sunwoo;Kim, Joouk;Kim, Youngmin;Kim, Hyungchul;Lee, Soohwan
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.1
    • /
    • pp.71-79
    • /
    • 2021
  • The railroad facilities are intended for long-term operation as the initial acquisition costs necessary for infrastructure construction are high. Therefore, regular maintenance of railroad facilities is essential, and furthermore, system reliability through systematic performance evaluation is required. In this study, the signal control system of railroad electrical equipment was selected as the subject of research and the performance evaluation target facility selection study was conducted using AHP. The results of the study can contribute to the reliability of the signal control system as well as to the reliability of the railroad system, which is a higher system.

Structural monitoring of movable bridge mechanical components for maintenance decision-making

  • Gul, Mustafa;Dumlupinar, Taha;Hattori, Hiroshi;Catbas, Necati
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.3
    • /
    • pp.249-271
    • /
    • 2014
  • This paper presents a unique study of Structural Health Monitoring (SHM) for the maintenance decision making about a real life movable bridge. The mechanical components of movable bridges are maintained on a scheduled basis. However, it is desired to have a condition-based maintenance by taking advantage of SHM. The main objective is to track the operation of a gearbox and a rack-pinion/open gear assembly, which are critical parts of bascule type movable bridges. Maintenance needs that may lead to major damage to these components needs to be identified and diagnosed timely since an early detection of faults may help avoid unexpected bridge closures or costly repairs. The fault prediction of the gearbox and rack-pinion/open gear is carried out using two types of Artificial Neural Networks (ANNs): 1) Multi-Layer Perceptron Neural Networks (MLP-NNs) and 2) Fuzzy Neural Networks (FNNs). Monitoring data is collected during regular opening and closing of the bridge as well as during artificially induced reversible damage conditions. Several statistical parameters are extracted from the time-domain vibration signals as characteristic features to be fed to the ANNs for constructing the MLP-NNs and FNNs independently. The required training and testing sets are obtained by processing the acceleration data for both damaged and undamaged condition of the aforementioned mechanical components. The performances of the developed ANNs are first evaluated using unseen test sets. Second, the selected networks are used for long-term condition evaluation of the rack-pinion/open gear of the movable bridge. It is shown that the vibration monitoring data with selected statistical parameters and particular network architectures give successful results to predict the undamaged and damaged condition of the bridge. It is also observed that the MLP-NNs performed better than the FNNs in the presented case. The successful results indicate that ANNs are promising tools for maintenance monitoring of movable bridge components and it is also shown that the ANN results can be employed in simple approach for day-to-day operation and maintenance of movable bridges.

ANALYSIS ON THE EVALUATION OF PROJECT EFFICIENCY BASED ON BUDGET EXECUTION: PLANNED OUTAGE MAINTENANCE (POM) FOR ELECTRICITY POWER PLANT

  • Sungkon Moon;Sangwon Han;Myoungwon Kang
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.66-73
    • /
    • 2011
  • With rapid industrialization, electric power consumption has been increasing every year in Korea and in other countries. The provision of additional power stations to produce more electricity is one possible response to this steady increase in consumption. Another alternative is to improve the efficiency of existing stations through timely and effective maintenance works. Since the construction of a new power plant involves a large amount of capital as well as difficulties in the selection of sites, the improvement of existing power stations' efficiencies is often a preferred solution. Therefore, this paper focuses on maintenance project management to address this issue. Among several types of maintenance works, this paper concentrates on planned outage maintenance (POM). This focus arises from the critical impact of POM on other maintenance work, as well as the entire process of electricity production. Unlike other maintenance work, POM is done on the basis of mid and long-term plans. In addition, only POM works are conducted during the outage of all power plants. To evaluate the efficiency of POM works, budget data relating to 164 POM projects between 2001 and 2008 was collected from 7 sites in South Korea. Data envelopment analysis (DEA) was selected as a methodology for evaluation. From this analysis, comparative study was used to determine the categories of projects that had performed well, and those with the most optimized budget structures. Moreover, through discussion with industry, this research develops a feasible proposed method by which to enhance the efficiency of POM projects.

  • PDF

Rodent model for long-term maintenance and development of the viable cysticerci of Taenia saginata asiatica

  • Wang, I.C.;Chung, W.C.;Lu, S.C.;Fan, P.C.
    • Parasites, Hosts and Diseases
    • /
    • v.38 no.4
    • /
    • pp.237-244
    • /
    • 2000
  • Although oncospheres of Taenia saginata asiatica can develop into cysticerci in immunodeficiency, immunosuppressed, and normal mice, no detailed information on the development features of these cysticerci from SCID mice is available. In the present study, the tumor-like cyst was found in the subcutaneous tissues of each of 10 SCID mice after 38-244 days inoculation with 39,000 oncospheres of T. s. asiatica. These cysts weighed 2.0-9.6 gm and were 1.5-4.3 cm in diameter. The number of cysticerci were collected from these cysts ranged from 125 to 1,794 and the cysticercus recovery rate from 0.3% to 4.6%. All cysticerci were viable with a diameter of 1-6 mm and 9 abnormal ones each with 2 evaginated protoscoleces were also found. The mean length and width of scolex, protoscolex, and bladder were $477{\;}{\times}{\;}558,{\;}756{\;}{\times}{\;}727,{\;}and{\;}1,586{\;}{\times}{\;}1,615{\;}$\mu\textrm{m}$, respectively. The diameters of suckers and rostellum were $220{\mu\textrm{m}}{\;}and{\;}70\mu\textrm{m}$, respectively All cysticerci had two rows of rostellar hooks. These findings suggest that the SCID mouse model can be employed as a tool for long-term maintenance of the biological materials for advanced studies of immunodiagnosis, vaccine development, and evaluation of cestocidal drugs which would be most benefit for the good health of the livestocks.

  • PDF

Evaluation of Tension of Stay Cable using MBM (Measurement-based Model) (계측기반모델에 의한 사장케이블의 장력 평가)

  • Nam, Sang-Jin;Yhim, Sung-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.93-100
    • /
    • 2014
  • This study presents the recomposition of MBM (measurement-based model) using natural frequencies and modes from the usually measured data, and the evaluation of cable tension in service from the analysis results upon MBM of existing CSB (cable stayed bridge). The cable tension is shown to be different according to the position attached to cable and loading type. The measured cable tensions are not different distinctly according to position attached cable under dead and live loads, but larger than those under design loads. The distribution of cable tension calculated upon the MBM is similar to those of measured tension although the former is more than those of cable tension upon the design model. Considering to long-term behaviors of cable, therefore, the design of cable in CSB needs to apply the analysis results on MBM. For this purpose, future study needs lots of measured data and MBM is used to analyze the long-term behavior of cable in CSB.

Characteristics of Calcium Leaching Resistance for Concrete Mixed with Mineral Admixture (광물질 혼화재를 혼합한 콘크리트의 칼슘용출 저항 특성)

  • Choi, So-Yeong;Choi, Yoon-Suk;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.59-67
    • /
    • 2016
  • Concrete is a very useful construction material for the sealing disposal of hazardous substances. In general, mass concrete is applied to these structures. And, the mineral admixtures are recommended for the long term performance. Calcium leaching could be happened due to the contact with pure water in underground structures. Thus, it is needed to evaluate the resistance of calcium leaching for concrete mixed with mineral admixtures. From the test results, the mineral admixtures are effective to the improvement of long term compressive strength and chloride diffusion coefficient in concrete members. When calcium leaching is happened, however, the reduction of compressive strength and chloride penetration resistance is severe than OPC case, the micro pore distribution is adversely affected. Consequently, when the mineral admixtures are applied to underground structures which is exposed to calcium leaching environment, it is desirable to reduce water-to-binder ratio, to expose after the sufficient pozolanic reaction, and to use BFS than FA.