• Title/Summary/Keyword: long implant

Search Result 514, Processing Time 0.031 seconds

A 10-YEAR RETROSPECTIVE CLINICAL STUDY OF $BR{\AA}NEMARK$ IMPLANTS ($Br{\aa}nemark$ 임플랜트의 10년 후향적 임상연구)

  • Bae, Jung-Yoon;Shin, Sang-Wan;Cho, Hyun-Jung;Kim, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.48-59
    • /
    • 2007
  • Statement of problems: There are few studies which reported the survival rates of the specific dental implant systems in the Korean population with the follow-up periods longer than 5 years. Purpose: This retrospective clinical study was aimed to evaluate cumulative survival rate (CSR) of $Br{\aa}nemark$ implants followed for 10 years and to determine risk factors for implant failure. Material and methods: A total of 271 $Br{\aa}nemark$ implants in 83 patients were investigated with several identified risk factors. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR. Results: Thirty implants failed. The 10-year implant CSR was 82.5%. Cox regression analysis demonstrated a significant predictive association between overall CSR and implant length (P<.05). Conclusion: An acceptable long-term result of $Br{\aa}nemark$ implant was achieved and implant length showed a significant association with the CSR.

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF FIVE DIFFERENT TAPER DESIGN IMPLANT SYSTEMS (3차원 유한요소법적 분석을 이용한 5종의첨형 임플랜트에 발생하는 응력의 비교연구)

  • Byun, Sang-Ki;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.584-593
    • /
    • 2006
  • Statement of problem : Dental implant which has been developed gradually through many experiments and clinical applications is presently used to various dental prosthetic treatments. To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately of load support. Therefore, it is essential to give the consideration about the stress analysis of supporting tissues for higher successful rates. Purpose : Recently, many implant manufacturing company produce various taper design of root form implant, the fixture is often selected. However, the stress analysis of taper form fixture still requires more studies. Material and method : This study we make the element models that five implant fixture; Branemark system(Nobel Biocare, Gothenberg, Sweden), Camlog system(Altatec, Germany), Astra system(Astra Tech, Sweden), 3i system(Implant Innovations Inc, USA), Avana system(Osstem, Korea) were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the three-dimension finite element analysis under two loading condition. Results : This study compares the aspect of stress distribution of each system with the standard of Von mises stress, among many resulted from finite element analysis so that this research gets the following results. 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and type of system, cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. under the vertical loading, maximum Von mises stress is more higher in order of Branemark, Camlog, Astra, 3i, Avana. under the horizontal loading, maximum Von mises is more higher in order of Camlog, Branemark, Astra, 3i, Avana.

Effect of different lateral occlusion schemes on peri-implant strain: A laboratory study

  • Lo, Jennifer;Abduo, Jaafar;Palamara, Joseph
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.45-51
    • /
    • 2017
  • PURPOSE. This study aims to investigate the effects of four different lateral occlusion schemes and different excursions on peri-implant strains of a maxillary canine implant. MATERIALS AND METHODS. Four metal crowns with different occlusion schemes were attached to an implant in the maxillary canine region of a resin model. The included schemes were canine-guided (CG) occlusion, group function (GF) occlusion, long centric (LC) occlusion, and implant-protected (IP) occlusion. Each crown was loaded in three sites that correspond to maximal intercuspation (MI), 1 mm excursion, and 2 mm excursion. A load of 140 N was applied on each site and was repeated 10 times. The peri-implant strain was recorded by a rosette strain gauge that was attached on the resin model buccal to the implant. For each loading condition, the maximum shear strain value was calculated. RESULTS. The different schemes and excursive positions had impact on the peri-implant strains. At MI and 1 mm positions, the GF had the least strains, followed by IP, CG, and LC. At 2 mm, the least strains were associated with GF, followed by CG, LC, and IP. However, regardless of the occlusion scheme, as the excursion increases, a linear increase of peri-implant strains was detected. CONCLUSION. The peri-implant strain is susceptible to occlusal factors. The eccentric location appears to be more influential on peri-implant strains than the occlusion scheme. Therefore, adopting an occlusion scheme that can reduce the occurrence of occlusal contacts laterally may be beneficial in reducing peri-implant strains.

Study about the complications associated with implant surgery and prosthetic treatment (임프란트 수술 및 보철물에 따른 합병증 연구)

  • Lee, Ji-Young;Kim, Young-Kyun;Yun, Pil-Young;Bae, Ji-Hyun;Kim, Jae-Seung
    • The Journal of the Korean dental association
    • /
    • v.47 no.9
    • /
    • pp.585-595
    • /
    • 2009
  • Purpose : The aim of this study was to compare surgical complications between simple implant placement and implant placement combined with complicated surgical procedures. We also evaluated prosthetic complications according to the specific types of prosthesis. Material and Method : A retrospective analysis of dental chart of patients who was performed implant therapy during the period from June 2003 to December 2005 was carried out. This study was performed on 408 patients (208 male, 200 female). In addition, 1671 implants were performed. Based on their medical record and radiographs, the authors evaluated surgical and prosthetic complications, surgical procedures accompanied at the time of implant, risk factors of implant failure etc. Result : Surgical complications were developed on 358 implants(21.4% on total placed implants) and wound dehiscence was most prevalent complication. On maxillary posterior area, surgical complications developed more frequently on implants with major surgery and showed a significant difference. And complication rate of implants accompanied with GBR was higher than that of simple implants placement and also showed significant difference. The implant supported prosthesis showed no statistical difference in the occurrence of complications according to the types of prosthesis, and food retention was the most common post-prosthetic complication. Also we speculated that length and width of implant showed significant correlation to the failure of implant primary osseointegration. Conclusion : Based on the result, clinician should provide more careful maintenance for patients with implant placement accompanied by complicated surgical procedure. And periodic maintenance for the patient is requested for long-term survival of implant therapy.

  • PDF

Factors associated with the survival rate and the marginal bone loss of dental implant over 7-years loading (7년 이상 기능한 임플란트의 변연골 흡수와 생존율에 영향을 주는 요인)

  • Choi, Jung-Hyeok;Koh, Jae-kwon;Kwon, Eun-Young;Joo, Ji-Young;Lee, Ju-Youn;Kim, Hyun-Joo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.116-126
    • /
    • 2018
  • Purpose: The purpose of this study was to analyze the factors affecting the survival rate and the marginal bone level of dental implants that have functioned over 7-years. Materials and Methods: In 92 patients, 178 dental implants were included. Implant-related factors (diameter, length, prosthetic splint), patient-related factors (gender, smoking, plaque index, compliance to supportive periodontal therapy) and surgery-related factors (proficiency of surgeon, bone graft) were evaluated via clinical and radiographic examination. The marginal bone level was determined by intraoral standard radiography at the mesial and distal aspects of each implant using an image analysis software program. Results: The survival rate of all the implants was 94.94% and the marginal bone level was $0.89{\pm}1.05mm$, these results are consistent with other studies that present long-term good clinical results. Implant length and plaque index among several factors were statistically significant for implant survival rate (P < 0.05). Smoking and the presence of regeneration surgery were statistically significant for the marginal bone level (P < 0.05). Conclusion: Dental implant that have functioned over 7-years showed favorable long-term survival rates and marginal bone level. Implant length and plaque control should be considered for improving the long-term clinical results. It is needed that careful application of bone regeneration technique and smoking control for maintaining of marginal bone level.

The cumulative survival rate of dental implants with micro-threads: a long-term retrospective study

  • Dong-Hui Nam;Pil-Jong Kim;Ki-Tae Koo;Yang-Jo Seol;Yong-Moo Lee;Young Ku;In-Chul Rhyu;Sungtae Kim;Young-Dan Cho
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.1
    • /
    • pp.53-62
    • /
    • 2024
  • Purpose: This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. Methods: This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant® dental implants with an implant neck micro-thread design during 2006-2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan-Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. Results: Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between external-and internal-implant types (98.2% and 97.6%, respectively, P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. Conclusions: Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes.

Long-term Retrospective Clinical Study Comparing Submerged Type with External Hex Connection and Non-submerged Type with Internal Morse Taper Connection Implants

  • Kwoen, Min-Jeong;Kim, Sang-Yun;Kim, Young-Kyun
    • Journal of Korean Dental Science
    • /
    • v.12 no.1
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose: This study was aimed to compare the survival and success rates, and long-term crestal bone loss according to the use of 2 connection types of dental implants (submerged-USII and non-submerged-SSII; Osstem $Implant^{(R)}$) by analyzing the change in alveolar bone height after 1 year under load and during final follow-up period. Materials and Methods: Between December 2004 and August 2008, patients with two types of Osstem implants (USII and SSII) were retrieved retrospectively. A total of 92 patients with 284 implants (USII=60, SSII=224) was finally selected. Their mean follow-up period was 7.5 years. The mesial and distal alveolar crestal bone changes were measured using radiographic images and the average was calculated at 1 year after loading and during final follow-up period. Result: Among the 284 implants, 4 USII and 7 SSII implants were removed, indicating 93.3% and 96.9% survival rates. Of the survived implants, mean crestal bone loss 1 year after loading was 0.39 mm for USII and 0.19 mm for SSII (P=0.018). During the final follow-up, mean crestal bone loss was 0.63 mm and 0.35 mm for USII and SSII, respectively, without statistical significance (P=0.092). According to the criteria for the success and failure of the implant by Albreksson and colleagues, final success rate was estimated as 86.7% for USII and 91.5% for SSII, respectively. Conclusion At 1 year after loading, the average crestal bone loss was significantly different between USII and SSII; however, both types met the criteria for implant success. During the final follow-up, both groups showed insignificant bone resorption patterns and did not show any pathological clinical symptoms. Therefore, both implants exhibited high long-term stability.

A STUDY ON THE VARIOUS IMPLANT SYSTEMS USING THE FINITE ELEMENT STRESS ANALYSIS (수종의 임플랜트 시스템에 따른 유한요소법적 응력분석에 관한 연구)

  • Yu Seong-Hyun;Park Won-Hee;Park Ju-Jin;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.207-216
    • /
    • 2006
  • Statement of Problem: To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately within the limitation of alveolar bone around implant and bio-capacity of load support. Now implant which is used in clinical part has a very various shapes, recently the fixture that has tapered form of internal connection is often selected. However the stress analysis of fixtures still requires more studies. Purpose: The purpose of this study is to stress analysis of the implant prosthesis according to the different implant systems using finite element method. Material and methods: This study we make the finite element models that three type implant fixture ; $Br{\aa}nemark$, Camlog, Frialit-2 were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the finite element analysis under two loading condition. Conclusion: The conclusions were as follows: 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and the type of system. cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. 3. Under the vertical loading, maximum Von mises stress of $Br{\aa}nemark$ system with external connection type and tapered form is lower than Camlog and Frialit-2 system with internal connection type and tapered form, but under oblique loading Camlog and Frialit-2 system is lower than $Br{\aa}nemark$ system.

A FINITE ELEMENT STRESS ANALYSIS OF THE STRESS DISTRIBUTION AND THE SHOCK ABSORPTION IN AN OSSEOINTEGRATED IMPLANT-NATURAL TOOTH SUPPORTED FIXED PARTIAL DENTURE (골유착성 임프란트와 자연치를 이용한 고정성 국소의치에서 응력분산 및 충격흡수에 관한 유한요소법적 응력분석)

  • Jeong Chang-Mo;Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.4
    • /
    • pp.582-610
    • /
    • 1992
  • The long-term success of any dental implant is dependent upon the optimization of stresses which occur during oral function and parafunction. Especially, it has been suggested that there is an unique set of problems associated with joining an osseointegrated implant and a natural tooth with a fixed partial denture. For this particular case, although many literatures suggest different ways to avoid high stress concentrations on the bone surrounding the implant under static and dynamic loading conditions, but few studies on the biomechanical efficacy of each assertion have been reported. The purpose of this investigation was to evaluate the efficacies of clinically suggested methods on stress distribution under static load and shock absorption under dynamic load, using two dimensional finite element method. In FEM models of osseointegrated implant-natural tooth supported fixed partial dentures, calculations were made on the stresses in surrounding bone and on the deflections of abutments and superstructure, first, to compare the difference in stress distribution effects under static load by the flexure of fastening screw or prosthesis, or intramobile connector, and second, to compare the difference in the shock absorption effects under dynamic load by intramobile connector or occlusal veneering with composite resin. The results of this analysis suggest that : 1. Under static load condition, using an implant design with fastenign screw connecting implant abutment and prosthesis or increasing the flexibility of fastening screw, or increasing the flexibility of prosthesis led to the .increase in height of peak stresses in cortical bone surrounding the implant, and has little effect on stress change in bone around the natural tooth. 2. Under static load condition, intramobile connector caused the substantial decrease in stress concentration in cortical bone surrounding the implant and the slight increase in stress in bone around the natural tooth. 3. Under dynamic load condition, both intramobile connector and composite resin veneering showed shock absorption effect on bone surrounding the implant and composite resin veneering had a greater shock absorption effect than intramobile connector.

  • PDF

Clinical evaluation of 3.0-mm narrow-diameter implants: a retrospective study with up to 5 years of observation

  • InKyung Hwang;Tae-Il Kim;Young-Dan Cho
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.1
    • /
    • pp.44-52
    • /
    • 2024
  • Purpose: This study aimed to evaluate the clinical outcomes of a single type of narrow-diameter implant (NDI) by investigating its survival rate and peri-implant marginal bone loss (MBL). In addition, variables possibly related to implant survival and MBL were investigated to identify potential risk factors. Methods: The study was conducted as a retrospective study involving 49 patients who had received 3.0-mm diameter TSIII implants (Osstem Implant Co.) at Seoul National University Dental Hospital. In total, 64 implants were included, and dental records and radiographic data were collected from 2017 to 2022. Kaplan-Meier survival curves and a Cox proportional hazard model were used to estimate the implant survival rate and to investigate the effects of age, sex, jaw, implant location, implant length, the stage of surgery, guided bone regeneration, type of implant placement, and the surgeon's proficiency (resident or professor) on implant survival. The MBL of the NDIs was measured, and the factors influencing MBL were evaluated. Results: The mean observation period was 30.5 months (interquartile range, 26.75-45 months), and 6 out of 64 implants failed. The survival rate of the NDIs was 90.6%, and the multivariate Cox regression analysis showed that age was associated with implant failure (hazard ratio, 1.17; 95% confidence interval, 1.04-1.31, P=0.01). The mean MBL was 0.44±0.75 mm, and no factors showed statistically significant associations with greater MBL. Conclusions: NDIs can be considered a primary alternative when standard-diameter implants are unsuitable. However, further studies are required to confirm their long-term stability.