• Title/Summary/Keyword: long baseline

Search Result 495, Processing Time 0.023 seconds

A Comparative Study on the Balance of Musculoskelectal System between Long-Term Employed Male Taxi Drivers and General People - through Moire Topography (장기근속 남성 택시기사와 일반인의 근골격계 균형에 관한 비교 연구 - 모아레 체형측정법을 통해)

  • Lim, Sang-Hoon;Park, Dong-Su;Lee, Kyung-Moo;Jeong, Su-Hyeon;Kim, Soon-Joong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.1
    • /
    • pp.141-151
    • /
    • 2008
  • Objectives : The purpose of this study was to investigate effects of long-term taxi driving posture on the balance of musculoskelectal system. Methods : The author practiced Moire topography by using IBS-2000 for 30 male taxi drivers and general people. Then we measured difference of contour lines, difference of shoulder joint height, interval between vertical baseline of pelvis and vertical baseline of neck, ratio of thoracic curve and lumbar curve, difference of width between right and left through Moire topography. After we statistically analyzed difference of Moire topography's data between long-term employed male taxi drivers and general people. Results : 1. Taxi drivers, difference of contour lines in scapular, lumbar, gluteal region was bigger than general people and significant difference(p<0.05) was observed between subject group. 2. Taxi drivers, diference of shoulder joint height was more large than general people and significant difference(p<0.01) was observed between subject group. 3. Taxi drivers, diference of interval between vertical baseline of pelvis and vertical baseline of neck was more large than general people and significant difference((p<0.05) was observed between subject group. 4. Taxi drivers, ratio of thoracic curve was more large than general people and ratio of lumbar curve was more less than general people and significant difference(p<0.05) was observed between subject group. Conclusions : According to above results long-term taxi driving posture might cause musculoskelectal system unbalance.

Long-baseline single-layer 2nd-order $high-T_c$ SQUID gradiometer (긴기저선을 가진 단일층 고온초전도 SQUID 2차미분기)

  • Lee Soon-Gul;Kang Chan Seok;Kim In-Seon;Kim Sang-Jae
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.6-10
    • /
    • 2005
  • We have studied feasibility of single-layer second-order $high-T_c$ SQUID gradiometers in magnetocardiography. We have measured human cardiomagnetic signals using a short-baseline (5.8 mm) single-layer second-order YBCO gradiometer in partially shielded environments. The gradiometer has an overall size of $17.6\;mm{\times}6\;mm$ and contains three parallel-connected pickup coils which are directly coupled to a step-edge junction SQUID. The gradiometer showed an unshielded gradient noise of $0.84\;pT/cm^2/Hz^{1/2}$ at 1 Hz, which corresponds to an equivalent field noise of $280\;fT/Hz^{1/2}$. The balancing factor was $10^3$. Based on the same design rules as the short-baseline devices, we have studied fabrication of 30 mm-long baseline gradiometers. The devices had an overall size of $70.2\;mm{\times}10.6\;mm$ with each pickup coil of $10\;mm{\times}10\;mm$ in outer size. As Josephson elements we made two types of submicron bridges, which are variable thickness bridge (VTB) and constant thickness bridge (CTB), from $3\;{\mu}m-wide$ and 300 nm-thick YBCO lines with a thin layer of Au on top by using a focused ion beam (FIB) patterning method. VTB was 300 nm wide, 200 nm thick, 30 nm long with Au removed and CTB 100 nm wide and 30 nm long. In temperature-dependent critical currents, $I_c(T)$, VTB showed an nonmetallic barrier-type behavior and CTB an SNS behavior. We believe that those characteristics are ascribed to naturally formed grain boundaries crossing the bridges.

  • PDF

Precision Improvement of Long Baseline Determination by IGS Ephemeris and Geodetic Positioning of '96 Korea GPS Fiducial Network (정밀(IGS)력을 이용한 장기선 해석 및 전국망 성과 분석)

  • Choi, Yun-Soo;Sa, Jae-Kwang;Cho, Heung-Muk;Park, Byung-Uk;Kim, Woong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.1
    • /
    • pp.51-58
    • /
    • 1998
  • The goal of this study is to propose a precision improvement scheme for long baseline determination based on the use of IGS ephemeris and different cutoff angles. It is also to present the adjustment results of ’96 Korea GPS fiducial network. In order to obtain more accurate coordinates in precise geodetic surveying, the revision of specification is necessary for the field operation and procedure of baseline processing.

  • PDF

Estimation of Ionospheric Delays in Dual Frequency Positioning - Future Possibility of Using Pseudo Range Measurements -

  • Isshiki, Hiroshi
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.185-190
    • /
    • 2006
  • The correct estimation of the ionospheric delays is very important for the precise kinematic positioning especially in case of the long baseline. In case of triple frequency system, the ionospheric delays can be estimated from the measurements, but, in case of dual frequency system, the situation is not so simple. The precision of those supplied by the external information source such as IONEX is not sufficient. The high frequency component is neglected, and the precision of the low frequency component is not sufficient for the long baseline positioning. On the other hand, the high frequency component can be estimated from the phase range measurements. If the low frequency components are estimated by using the external information source or pseudo range measurements, a more reasonable estimation of the ionospheric delays may be possible. It has already been discussed by the author that the estimation of the low frequency components by using the external information source is not sufficient but fairly effective. The estimation using the pseudo range measurements is discussed in the present paper. The accuracy is not sufficient at present because of the errors in the pseudo range measurements. It is clarified that the bias errors in the pseudo range measurements are responsible for the poor accuracy of the ionospheric delays. However, if the accuracy of the pseudo range measurements is improved in future, the method would become very promising.

  • PDF

A Study on the Effective Use of Long-Baseline Kinematic Surveying by GPS (GPS에 의한 장기선 이동측량의 효율성 검토)

  • Kang, Joon-Mook;Lee, Young-Wook;Park, Joung-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.8 no.2 s.16
    • /
    • pp.101-108
    • /
    • 2000
  • Kinematic GPS surveying which can be obtained many three-dimensional topographical informations through a short-time measurement is being utilized mainly in the short base line of a few km and below The coordinate for the long base line depends on Static GPS surveying But it needs long time measurement. Therefore, the method which can decide a position of the long base line for a short time is being needed. To examine a possibility of an efficient use of kinematic GPS surveying of the long base line, this research has analysed an accuracy of the base line by static GPS surveying according to baseline distance, ephmeris, and observation time. As the results of research, I could see that accuracy was very low in case of the occurrence of cycle slip. When we use of precise ephmeris, we obtained 1ppm and less of accuracy with one-minute kinematic GPS surveying within 70km. If a lot of studies about the long baseline kinematic GPS surveying are processed, a topographical information necessary for each kind of construction field including land development could be utilized more efficiently.

  • PDF

Review on Underwater Positioning for Deep Towing Vehicles (심해 예인 탐사장비의 위치 보정에 대한 고찰)

  • Lee, Gun-Chang;Ko, Young-Tak;Yoo, Chan-Min;Chi, Sang-Bum;Kim, Jong-Uk;Ham, Dong-Jin
    • Ocean and Polar Research
    • /
    • v.27 no.3
    • /
    • pp.335-339
    • /
    • 2005
  • The underwater positioning system is important in interpreting data that are acquired from towing vehicles such as the deep-sea camera (DSC) system. Currently, several acoustic positioning systems such as long baseline (LBL), short baseline (SBL), and ultra short baseline (USBL), are used for underwater positioning. The accurate position of DSC, however, could not be determined in a R/V Onnuri unequipped with any of these underwater positioning systems. As an alternative, the DSC position was estimated based on the topography of towing track and cable length in the cruises before 1999. The great uncertainties, however, were found in the areas of flat bottom topography. In the 2003 and 2004 cruises these uncertainties were reduced by calculating the position of DSC with the cable length and seafloor depth below the vessel. The Japanese cruises for Mn-nodule used a similar estimation method for the DSC positioning system with a CTD sensor. Although the latter can provide better information for the position of DSC, the USBL underwater positioning system is strongly recommended for establishing better positioning of DSC and other towing devices.

Fully Analog ECG Baseline Wander Tracking and Removal Circuitry using HPF Based R-peak Detection and Quadratic Interpolation

  • Nazari, Masoud;Rajeoni, Alireza Bagheri;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • v.7 no.3
    • /
    • pp.231-238
    • /
    • 2020
  • This work presents a fully analog baseline wander tracking and removal circuitry using high-pass filter (HPF) based R-peak detection and quadratic interpolation that does not require digital post processing, thus suitable for compact and low power long-term ECG monitoring devices. The proposed method can effectively track and remove baseline wander in ECG waveforms corrupted by various motion artifacts, whereas minimizing the loss of essential features including the QRS-Complex. The key component for tracking the baseline wander is down sampling the moving average of the corrupted ECG waveform followed by quadratic interpolation, where the R-peak samples that distort the baseline tracking are excluded from the moving average by using a HPF based approach. The proposed circuit is designed using CMOS 0.18-㎛ technology (1.8V supply) with power consumption of 19.1 ㎼ and estimated area of 15.5 ㎟ using a 4th order HPF and quadratic interpolation. Results show SNR improvement of 10 dB after removing the baseline wander from the corrupted ECG waveform.

Factors Impacting the Physical Function of Older Adults in Korean Long-Term Care Hospitals

  • Lee, Ji-Yun;Kim, Eun-Young;Cho, Eun-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.6
    • /
    • pp.780-787
    • /
    • 2011
  • Purpose: This study was conducted to examine activities of daily living (ADL) of older adults admitted to Korean long-term care hospitals (LTCHs), and to explore the patient and organizational factors that have an impact on the ADL of this population. Methods: A secondary analysis of the Korean minimum data set (K-MDS) of patients (N=14,369) and of the profiles of LTCHs (N=358) from the Health Insurance Review and Assessment Service was done between January and July 2008. The outcome variable was ADL score 6 months after baseline assessment. Multi-level linear regression was employed to explore the patient and organizational factors that affected ADL scores. Results: Of the patients, 45.4% had a baseline ADL score of between 31 and 40, with a score of 40 indicating that the patient was entirely dependent for all items. None of the organizational characteristics were significantly associated with effects on the ADLs of older adults who had been in a LTHC for at least 6 months. However, patient characteristics, such as age, baseline ADL, frequency of physical therapy, urinary incontinence, fecal incontinence, pressure ulcers, and having a tube or catheter, were significantly associated with ADL 6 months after baseline. Conclusion: In order to maintain and improve the ADL of older adults in LTCHs, we should develop strategies to prevent urinary and fecal incontinence, pressure ulcers, unnecessary tubes or catheters, providing adequate physical therapy. Additional studies should include more detailed information regarding nursing staff, including RN hours for direct care, education level and turnover.

Short- and Long-term Effects of a Physical Exercise Intervention on Work Ability and Work Strain in Symptomatic Menopausal Women

  • Rutanen, Reetta;Luoto, Riitta;Raitanen, Jani;Mansikkamaki, Kirsi;Tomas, Eija;Nygard, Clas-Hakan
    • Safety and Health at Work
    • /
    • v.5 no.4
    • /
    • pp.186-190
    • /
    • 2014
  • Background: Physical exercise during leisure time is known to increase physical capacity; however, the long-term effects on work ability and work strain are inconclusive. The aim of this study was to investigate the effects of a 6-month physical exercise program on work ability and work strain after 6 months and 30 months, among women with menopausal symptoms at baseline. Methods: A questionnaire including questions on work ability and work strain was mailed in the beginning, at 6 months and after 30 months after the intervention to occupationally active women participating in a randomized controlled study on physical exercise and quality of life. The intervention included aerobic exercise training 4 times per week, 50 minutes per session. Work ability was measured with the Work Ability Index (WAI) and with questions about physical and mental work strain. Results: Women aged 47-62 years (N=89) who were occupationally active at baseline were included in the analyses. The increase in WAI from baseline to the end of the exercise intervention (6 months) was statistically significantly greater among the intervention group than among the control group (regression coefficient 2.08; 95% confidence interval 0.71-3.46). The difference between the groups persisted for 30 months. No significant short- or long-term effects on physical and mental work strain were found. Conclusion: A 6-month physical exercise intervention among symptomatic menopausal women had positive short-term as well as long-term effects on work ability.

Instrumentation and Structural Health Monitoring of Bridges (교량구조물의 헬스모니터 링을 위한 진동계측)

  • 김두기;김종인;김두훈
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.5
    • /
    • pp.108-122
    • /
    • 2001
  • As bridge design is advancing toward the performance-based design. it becomes increasingly important to monitor and re-evaluate the long-term structural performance of bridges. Such information is essential in developing performance criteria for design. In this research. sensor systems for long-term structural performance monitoring have been installed on two highway bridges. Pre1iminary vibration measurement and data analysis have been performed on these instrumented bridges. On one bridge, ambient vibration data have been collected. based on which natural frequencies and mode shapes have been extracted using various methods and compared with those obtained by the preliminary finite element analysis. On the other bridge, braking and bumping vibration tests have been carried out using a water truck In addition to ambient vibration tests. Natural frequencies and mode shapes have been derived and the results by the breaking and bumping vibration tests have been compared. For the development of a three dimensional baseline finite element model, the new methodology using a neural network is proposed. The proposed one have been verified and applied to develop the baseline model of the bridge.

  • PDF