• Title/Summary/Keyword: long arm

Search Result 313, Processing Time 0.025 seconds

A study on the torso body size and body shape classification of obese adult women (비만 성인 여성의 토르소 신체 치수 및 체형 분석)

  • Sohn, Jae-Min;Kim, Dong-Eun
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.5
    • /
    • pp.561-576
    • /
    • 2017
  • The purpose of this study was to classify the upper torso body types of obese Korean adult women using the 7th Korea National Anthropometric Study data and compare the body type differences according to three age groups: 20s~30s, 40s~50s, and 60s. A total of 548 adult women whose BMI was in the obese range of 25 or higher and whose age ranged from 20s to 60s were selected from the anthropometric database. Twenty-nine body measurements related to torso and arm areas important for torso and sleeve pattern development were chosen. Five drop values by differences between bust, waist, and hip circumferences were also chosen for analysis. The number of obese women increased with age. The results revealed seven factors according to the factor analysis and three obese body types based on the cluster analysis. Body type 1 (47.3% of obese women) was characterized by narrow shoulders, a small or medium torso, and a straight waist. Body type 2 (42.4% of obese women) was characterized by a defined waist and a larger lower torso than upper torso. Body type 3 (10.3% of obese women), the largest obese body type among the three types, was characterized by a large bust, large abdomen area, and long upper torso. Women in their 20s to 30s were most likely to have body type 2, women in their 40s to 50s were evenly distributed between body types 2 and 3, and women in their 60s were most likely to have body type 1.

The Analysis of Types and Historical Review of False Sleeves (False Sleeves의 유형분석과 복식사적 고잘)

  • Kwon, Soo-Hyun;Kang, Soon-Che
    • Journal of the Korean Society of Costume
    • /
    • v.60 no.10
    • /
    • pp.163-179
    • /
    • 2010
  • False sleeves are 'the sleeves that are attached to clothes but exist just as a part without any function to put arms in them.' They are different from sleeves to put arms in them and are to follow the trend or a way of wearing clothes. They are mostly found in medieval Europe's decorative sleeves named 'Hanging sleeves', but they are also found in Eastern region, too. They are found in sleeves that attached women's headgear in East and Middle Asia, and also in high-class male caftan in Ottoman Turk in the 16th and 17th century. False sleeves can be divided into two kinds by shapes. The first ones are the decorative sleeves of which trunk-shaped sleeves hang around the whole or part of the arm hole but have no function to put arms in them; this is called as 'sleeve-shaped False sleeves'. These sleeves are found in women's headgear in medieval Europe, Ottoman Turk, and East and Middle Asia. False sleeves in Europe and Ottoman Turk played a role in showing wealth and power while those in East and Middle Asia had a great role in highlighting the costume's decorative effect. The second ones are the sleeves hanging down from the arms by attaching long cloth to the arm hole, in design; these are named as 'cape-shaped False sleeves.' This style is found only in medieval Europe, and presumably, these cape-shaped false sleeves may have played a role in boasting of one's wealth and power.

Molecular Analysis of the Y Chromosome in a 46,XY Female Phenotype

  • Kim, Jin-Woo;Kim, Tae-Jin;Park, So-Yeon;Nam, Sung-A;Jun, Jong-Young
    • Journal of Genetic Medicine
    • /
    • v.3 no.1
    • /
    • pp.5-10
    • /
    • 1999
  • This is a case report of 46,XY female phenotype (46,XY karyotype, no pubic hair, blind vagina and absence of uterus)in an 18-year-old patient. To confirm whether a Y chromosome has a structural abnormality, fluorescent in situ hybridization (FISH) with the chromosome X/Y cocktail probe was simultaneously performed, and the six loci [PABY, RPS4Y(sy16, sy17), ZFY, DYS14] on the short arm, one locus (DYZ3) on the centromere and one locus (DYZ1) on the long arm were amplified by polymerase chain reaction (PCR). The probes used FISH hybridized to centromere of the X chromosome and heterochromatin region (Yq12) of the Y chromosome, and all PCR related Y chromosome showed positive band like normal male. From the results obtained, it seemed that the Y chromosome from the 46,XY female was structurely normal. Especially, the SRY gene has been equated with the mammalian testis-determining factor, and absence or point mutation in the SRY gene causes XY female. To detect the point mutations of SRY sequences, single-strand conformation polymorphism (SSCP) assay was used. Our results confirm that this patient has no mutation in the SRY gene on the Y chromosome.

  • PDF

Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization (자체 제작한 정위적체부방사선치료(Stereotactic Body Radiotherapy) 고정용구의 유용성 평가)

  • Lee, Dong-Hoon;Ahn, Jong-Ho;Seo, Jeong-Min;Shin, Eun-Hyeok;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Materials and Methods: Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. Results: The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. Conclusion: The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations. Particularly in case of the stereotactic body therapy which requires the maintenance of set-up state for a long time, the self-developed immobilizations is thought to more useful for stereotactic body radiotherapy rather than the rest two immobilizations with instable respiratory cycle as time passes.

  • PDF

Long-Term Follow-Up Results of Anterior Cervical Inter-Body Fusion with Stand-Alone Cages

  • Kim, Woong-Beom;Hyun, Seung-Jae;Choi, Hoyong;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.385-391
    • /
    • 2016
  • Objective : The purpose of this study was to evaluate long-term follow-up radiologic/clinical outcomes of patients who underwent anterior cervical discectomy and inter-body fusion (ACDF) with stand-alone cages (SAC) in a single academic institution. Methods : Total 99 patients who underwent ACDF with SAC between February 2004 and December 2012 were evaluated retrospectively. A total of 131 segments were enrolled in this study. Basic demographic information, radiographic [segmental subsidence rate, fusion rate, C2-7 global angle, and segmental angle changes)/clinical outcomes (by Odom's criteria and visual analog score (VAS)] and complications were evaluated to determine the long-term outcomes. Results : The majority were males (55 vs. 44) with average age of 53.2. Mean follow-up period was 62.9 months. The segmental subsidence rate was 53.4% and fusion rate was 73.3%. In the subsidence group, anterior intervertebral height (AIH) had more tendency of subsiding than middle or posterior intervertebral height (p=0.01). The segmental angle led kyphotic change related to the subsidence of the AIH. Adjacent segmental disease was occurred in 18 (18.2%) patients. Total 6 (6%) reoperations were performed at the index level. There was no statistical significance between clinical and radiological outcomes. But, overall long-term clinical outcome by Odom's criteria was unsatisfactory (64.64%). The neck and arm VAS score were increased by over time. Conclusion : Long-term outcomes of ACDF with SAC group were acceptable but not satisfactory. For optimal decision making, more additional comparative long-term outcome data is needed between ACDF with SAC and ACDF with plating.

Interstitial deletion of 5q33.3q35.1 in a boy with severe mental retardation

  • Lee, Jin Hwan;Kim, Hyo Jeong;Yoon, Jung Min;Cheon, Eun Jung;Lim, Jae Woo;Ko, Kyong Og;Lee, Gyung Min
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.sup1
    • /
    • pp.19-24
    • /
    • 2016
  • Constitutional interstitial deletions of the long arm of chromosome 5 (5q) are quite rare, and the corresponding phenotype is not yet clearly delineated. Severe mental retardation has been described in most patients who present 5q deletions. Specifically, the interstitial deletion of chromosome 5q33.3q35.1, an extremely rare chromosomal aberration, is characterized by mental retardation, developmental delay, and facial dysmorphism. Although the severity of mental retardation varies across cases, it is the most common feature described in patients who present the 5q33.3q35.1 deletion. Here, we report a case of a de novo deletion of 5q33.3q35.1, 46,XY,del(5)(q33.3q35.1) in an 11-year-old boy with mental retardation; to the best of our knowledge this is the first case in Korea to be reported. He was diagnosed with severe mental retardation, developmental delay, facial dysmorphisms, dental anomalies, and epilepsy. Chromosomal microarray analysis using the comparative genomic hybridization array method revealed a 16-Mb-long deletion of 5q33. 3q35.1(156,409,412-172,584,708)x1. Understanding this deletion may help draw a rough phenotypic map of 5q and correlate the phenotypes with specific chromosomal regions. The 5q33.3q35.1 deletion is a rare condition; however, accurate diagnosis of the associated mental retardation is important to ensure proper genetic counseling and to guide patients as part of long-term management.

Nutritional Assessment and Management in Long-term Care Insurance's Home Visit Care Service (경기도 일부 노인의 노인장기요양보험 방문요양서비스의 영양상태 평가 및 영양관리 현황)

  • Yoon, Mi-Ock;Moon, Hyun-Kyung;Kim, Seo-Yeon;Kim, Bok-Hee
    • Korean Journal of Community Nutrition
    • /
    • v.18 no.2
    • /
    • pp.142-153
    • /
    • 2013
  • The purpose of the study was to examine nutritional management and nutritional care demands of home-visit care service and the nutritional status of serviced elderly. The survey was carried out from $5^{th}$ to $21^{st}$ of January, 2011 among 37 In-Home Service institutions. The number of elderly surveyed by 143 care helpers was 281. Analysis was performed for 203 subjects (male: 44, female: 159). The age distribution was from 50 to 99 years. The grading by long-term care insuranceshowed 18,2% on level 1 and 2, and 81.8% on level 3. For the disease treatment, the proportion of implementing diet treatment turned out to be very low. The proportion of subjects living with their children was 45.3%, and living alone was 29.1%. The proportion of home-visit care among types of In-Home Service was 70%. Subjects who needed additional necessary diet management service turned out to be 40.9%. Diet management was the most necessary services from all levels. MNA (specifiy MNA) scores were significantly (p < 0.001) associated with BMI, mid-arm circumference (MAC), calf circumference (CC), intake problems, and weight loss during the last 3 months. For studied elderly, 45.3% were malnourished, and 46.8% were at the risk of malnutrition by MNA score. Based on the result of this survey, the nutritional care was not systematic on the In-Home Service. Prevention and management of the disease was much better than the treatment to improve the quality of life. We conclude that nutrition management is necessary for the elderly. To improve nutritional status of elderly in home care services, systematic nutrition management should be implemented.

Long Term Clinical and Radiological Follow-up Study in Spondylolisthesis, Grade I : Decompression with or without Instrument (GradeⅠ요추부 척추 전방 전위증의 치료 : 감압성 후궁절제술과 고정기구 삽입술의 비교)

  • Chung, Seung Young;Kim, Gook Ki;Lim, Young Jin;Kim, Tae Sung;Leem, Won;Rhee, Bong Arm
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.235-241
    • /
    • 2001
  • Objective : Controversy exists which surgical treatment better in lumbar grade I spondylolisthesis, decompressive laminectomy with or without lumbar instrumentation. Methods : Out of Sixty-four patients with lumbar spondylolisthesis underwent surgery, 18 patients operated with decompressive laminectomy alone and 44 patients with decompession and lumbar instrument, during recent 5-years between January, 1994 and December, 1998. The author studied a long term follow-up in the above two groups to analyzing the overall clinical outcomes in each group and to determining the incidence of pos-toperative radiologic instability. Results : 1) Overall postoperative symptoms improvement were not so different in both groups. 2) Postoperative progressive subluxation is more common after decompressive laminectomy without instrumentation than with instrumentation group. 3) Overall clinical outcomes were slightly better in decompressive laminectomy without instrumentation than with instrumentation group but there was no significant difference. 4) Postoperative radiologic changes did not seem to influence the patient-reported clinical outcomes. 5) Postoperative complications is more common in decompressive laminectomy with instrumentation group than without instrumentation group. Conclusion : In the surgical management of grade I spondylolisthesis, the efficiency and superiority of surgical treatments requires the cost effectiveness and risk/benefit analysis of decompressive laminectomy with or without instrumentation. Therefore, Further detailed studies of long term follow up in a large number of patients in each group are needed for choice of best treatment.

  • PDF

A Study On Low-cost LPR(License Plate Recognition) System Based On Smart Cam System using Android (안드로이드 기반 스마트 캠 방식의 저가형 자동차 번호판 인식 시스템 구현에 관한 연구)

  • Lee, Hee-Yeol;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.471-477
    • /
    • 2014
  • In this paper, we propose a low-cost license plate recognition system based on smart cam system using Android. The proposed system consists of a portable device and server. Potable device Hardware consists of ARM Cortex-A9 (S5PV210) processor control unit, a power supply device, wired and wireless communication, input/output unit. We develope Linux kernel and dedicated device driver for WiFi module and camera. The license plate recognition algorithm is consisted of setting candidate plates areas with canny edge detector, extracting license plate number with Labeling, recognizing with template matching, etc. The number that is recognized by the device is transmitted to the remote server via the user mobile phone, and the server re-transfer the vehicle information in the database to the portable device. To verify the utility of the proposed system, user photographs the license plate of any vehicle in the natural environment. Confirming the recognition result, the recognition rate was 95%. The proposed system was suitable for low cost portable license plate recognition device, it enabled the stability of the system when used long time by using the Android operating system.

A small ocean bottom electromagnetometer and ocean bottom electrometer system with an arm-folding mechanism (Technical Report) (팔-접힘 구조를 가지는 소규모 OBEM과 OBE시스템 (기술보고서))

  • Kasaya, Takafumi;Goto, Tada-nori
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • Natural magnetic fields are attenuated by electrically conductive water. For that reason, marine magnetotelluric surveys have collected data at long periods (1000-100 000 s). The mantle structure has been the main target of seafloor magnetotelluric measurements. To ascertain crustal structure, however, electromagnetic data at shorter periods are important, e.g. in investigations of megathrust earthquake zones, or in natural resource surveys. To investigate of the former, for example, electromagnetic data for periods of less than 1000 s are necessary. Because no suitable ocean bottom electromagnetometer (OBEM) has been available, we have developed a small OBEM and ocean bottom electrometer (OBE) system with a high sample rate, which has an arm-folding mechanism to facilitate assembly and recovering operations. For magnetic observation, we used a fluxgate sensor. Field observations were undertaken to evaluate the field performance of our instruments. All instruments were recovered and their electromagnetic data were obtained. Results of the first experiment show that our system functioned well throughout operations and observations. Results of other field experiments off Tottori support the claim that the electromagnetic data obtained using the new OBEM and OBE system are of sufficient quality for the survey target. These results suggest that this device removes all instrumental obstacles to measurement of electromagnetic fields on the seafloor.