• Title/Summary/Keyword: lock plate

Search Result 23, Processing Time 0.029 seconds

Optimal Design and Analysis of Ducted Fan Clutch With or Without Mechanical Lock-up (기계적 잠금장치의 적용여부에 따른 덕티드팬 클러치의 최적설계 및 분석)

  • Su-chul Kim;Jae-seung Kim;Sang-gon Moon;Geun-ho Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.10-15
    • /
    • 2023
  • Wet multi-disk clutch, a power switching device of the ducted fan, was optimized and results were analyzed. The clutch was divided into two types depending on whether a mechanical lock-up was applied or not. It was optimized under each design condition. Transfer torque capacity, friction material surface pressure, friction surface temperature, and drag torque were calculated as factors to optimize the clutch. The volume of separator plate and drag torque were used as the objective function for optimization. In the case of Type 1, which did not include a mechanical lock-up, the clutch could be operated regardless of the pitch angle of the ducted fan. However, the outer diameter of the friction surface was doubled, the volume was increased by 5~7 times, and the drag torque was increased by 7~12 times compared to those of Type 2, which included a mechanical lock-up.

Leakage and Rotordynamic Analysis of Damper Floating Ring Seal with Round­Hole Surfaces in the High Pressure Turbo Pump (원형 단면 구멍 표면을 갖는 댐퍼 후로팅 링 실의 누설량 및 회전체 동역학적 특성 해석)

  • 하태웅;이용복;김창호
    • Tribology and Lubricants
    • /
    • v.19 no.6
    • /
    • pp.349-356
    • /
    • 2003
  • A damper floating ring seal with round hole pattern surfaces is suggested for better leakage control. The flat plate test of the round hole pattern surfaces has been performed to yield an empirical friction factor model. The exact predictions of the lock­up position of the damper floating ring, the leakage performance, and the rotordynamic coefficients of the seal are necessary to evaluate the rotordynamic performance of the turbo pump unit. The governing equations including the empirical friction factor model for round hole pattern surfaces are solved by the Fast Fourier Transform method. The lock­up position, leakage flow rate, and rotordynamic coefficients are evaluated according to the geometric parameters of the damper floating ring seal. Theoretical results show that the damper floating ring seals yield less leakage and better rotordynamic stability than the floating ring seal with a smooth surface.

Analysis of Converter Transformer Exiting Current and Eddy Loss by FEM (FEM을 이용한 컨버터용 변압기 여자전류 및 와전류 손실해석)

  • Lee, Jeong-Geun;Lee, Gon;Cho, Ik-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.750-751
    • /
    • 2008
  • 본 논문은 컨버터용 변압기의 여자전류 해석을 통해 DC 성분 유입시 자속밀도-여자전류 곡선 그래프를 도출하여 철심포화 여부를 확인하며, 철심 공극에 의해 발생되는 누설자속(Leakage Flux)으로 인한 철구조물(Lock Plate)의 와전류 손실을 계산하였다. 변압기 해석을 위해 상용 해석 소프트웨어인 Maxwell 3D를 이용하였고, 철심의 비선형성을 고려하여 해석하였다.

  • PDF

Low Speed Weigh-In Motion System Using Multi-FBG Sensors (다중 광섬유 브라그 격자 센서를 적용한 저속용 자동계중 시스템)

  • Lee Hojoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.1
    • /
    • pp.21-28
    • /
    • 2004
  • We have demonstrated a low speed weigh-in motion system using FBG sensors and performed field test at a trial road. Technique, called identical chirped grating interrogation, have used for a demodulation relying on the mismatching of two identical broadband chirped gratings. We compensated the fluctuation of LED power and the temperature of sensor and used a lock-in amplifier to reduce effect of noise. We could design a bending plate that the measurement results are independent of position of weight. The FBG sensors weigh-in motion system showed linearity and reproducibility.

Effects of Co-current and Cross Flows on Circular Enhanced Gravity Plate Separator Efficiencies

  • Ngu, Lock Hei;Law, Puong Ling;Wong, Kien Kuok
    • Environmental Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.151-155
    • /
    • 2014
  • This study compares the effects of flow on oil and suspended solids removal efficiencies in circular enhanced gravity plate separator equipped with coalescence medium. Coalescence medium acts to capture rising oil droplets and settling solid particles and assist in the coalescence of oil and coagulation of solid. The circular separator uses an upflow center-feed perforated-pipe distributor as the inlet. The co-current flow is achieved using 4 increasing sizes of frustum, whereas cross flow uses inclined coalescence plates running along the radius of the separator. The different arrangement gave the cross flow separator a higher coalescence plan area per operational volume, minimal and constant travelling distance for the oil droplets and particles, lower retention time, and higher operational flowrate. The cross flow separator exhibited 6.04% and 13.16% higher oil and total suspended solids removal efficiencies as compared to co-current flow.

The Penn Polarimeters

  • Koch, Robert H.;Wolf, George W.;Hull, Anthony B.;Elias, Nicholas M. II;Holenstein, Bruce D.;Mitchell, Richard J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.69-77
    • /
    • 2012
  • This report describes the inception, development and extensive use over 30 years of elliptical polarimeters at the University of Pennsylvania. The initial Mark I polarimeter design utilized oriented retarder plates and a calcite Foster-Clarke prism as the analyzer. The Mark I polarimeter was used on the Kitt Peak 0.9 m in 1969-70 to accomplish a survey of approximately 70 objects before the device was relocated to the 0.72 m reflector at the Flower and Cook Observatory. Successive generations of automation and improvements included the early-80's optical redesign to utilize a photoelastic modulated wave plate and an Ithaco lock-in amplifier-the photoelastic modulating polarimeter. The final design in 2000 concluded with a fully remote operable device. The legacy of the polarimetric programs includes studies of close binaries, pulsating hot stars, and luminous late-type variables.

SPEECH-LANGUAGE EVALUATION BEFORE AND AFTER PHARYNGOPLASTY (인두피판성형술 전후의 언어 평가)

  • Yoo Yang-Keun;Han Jin-Soon;Kim Jung-Lock;Hwang Soon-Jung
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.3 no.2
    • /
    • pp.61-66
    • /
    • 2000
  • General characteristics of speech in deft palate patients are hypemasality and articulation disorder, which are affected by velopharyngeal inadequacy(VPI). 17 subjects with a chief complaint of 'nasal sounds and inaccurate pronunciation' underwent a speech-language evaluation before and after pharyngoplasty. Hypemasality and obligatory articulation errors were improved but compensatory articulation errors remained after pharyngoplasty. Above mentioned results indicate that resonance may be normal or improved following successful surgical management of VPI but, compensatory articulation errors will still persist. The separate recognition of hypemasality, compensatory and obligatory articulation errors in deft palate patients is important in determining the timing of therapy and selection of appropriate targets in therapy.

  • PDF

고자장, 저온 환경의 UHV surface magneto-optical Kerr effect 장비 구축 및 Fe/Cr(001)계의 자성특성 연구

  • Park, Yong-Seong;O, Yong-Rok;Hong, Ji-Sang;Kim, Won-Dong;Hwang, Chan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.400-400
    • /
    • 2010
  • 우리는 기본 진공 $10^{-11}\;Torr$의 UHV surface magneto-optical Kerr effect (SMOKE) 시스템을 quarter-wave plate를 사용하였던 기존의 방식에서 PEM (photo elastic modulator)를 사용하는 방식으로 장비의 기능을 향상시켰다. 기존 quarter-wave plate를 사용하는 방식의 경우 Kerr signal을 구하기 위해 편광자와 검광자를 수직으로 두어 광량을 0으로 만들어야 한다. 그러나 금속의 경우 대부분 가시광선 영역에서 큰 반사율 때문에 측정되는 광량이 편광자와 검광자를 거치면서 넓은 각도 범위에서 최소값을 갖기 때문에 정확한 영점을 잡는 데 한계가 있다. 이러한 단점을 해결하기 위하여 우리는 PEM을 이용한 위상변조방식을 사용하였다. 위상변조 방식은 Kerr signal과 관계된 양을 PEM을 이용하여 50 kH ($1{\omega}$)와 100 kH ($2{\omega}$)의 진동 주파수에 공조시키고 이를 Lock-in-amplifier를 사용하여 탐지하기 때문에 좋은 sensitivity를 얻을 수 있을 뿐 아니라 Kerr ellipticity와 Kerr rotation을 동시에 측정할 수 있다. 자화에 필요한 전자석은 순철로 된 코어를 제작하여 챔버에 부착하였고 10 A에서 최대 7 kOe의 고자장을 얻을 수 있어 포화자화가 큰 물질에 대해서도 필요한 자성영역까지 측정이 가능하게 하였다. 또 저온 측정을 위해 SMOKE 샘플 홀더를 개조하여 액체 질소를 이용하여 100 K 근방의 영역에서 온도를 제어할 수 있도록 저온 장치를 구성하였다. 여기에서 샘플 근처에 위차한 e-beam heater가 장착된 고온 부분과 액체 질소 냉각, 온도감지를 위한 센서, cartridge heater가 장착된 저온 부분을 sapphire plate로 분리하여 저온용 cartridge heater의 파손을 최소화하였다. 이러한 SMOKE 시스템을 구성한 후에 우리는 Fe/Cr(001)시스템의 자성특성에 대해 연구하였다. Fe/Cr 시스템은 Fe/Cr/Fe의 exchange coupling이나 bulk Cr의 복잡한 자성 특성 때문에 주목을 받아왔다. 이 연구에서 우리는 저온 및 상온에서 Cr(001) 단결정 위에 증착된 Fe 박막의 자성 특성을 보고한다.

  • PDF

Case Study of 4-Bar Linkage KAFO in Person With Poliomyelitis (소아마비에서 4절 연쇄 장하지보조기 사례연구)

  • Kim, Jang-Hwan;Kwon, Oh-Yun;Yi, Chung-Hwi;Cho, Sang-Hyun;Cynn, Heon-Seock;Choi, Heung-Sik
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.18-27
    • /
    • 2013
  • The purpose of this study was to compare the ring lock type knee-ankle-foot orthosis (KAFO) with newly developed 4-bar linkage KAFO on the gait characteristics of persons with poliomyelitis clinically. This 4-bar linkage is the stance control type KAFO which provide the stability during stance phase and knee flexion during swing phase. Two subjects participated in this study voluntarily. We provided the customized 4-bar linkage KAFO then asked the subjects to walk in level surface and stairs under the two different KAFO conditions. The characteristics of gait in the persons with poliomyelitis were evaluated using a 3D motion analysis system and force plate. Additionally 6 minute walk test for physiological cost index were conducted using pulse oximeter to measure the energy consumption. In the results of this study, the differences of 4-bar linkage KAFO compared with ring lock type KAFO are as follows: (1) Walking speed, stride length, and step length on level increased in subjects, (2) The gait symmetry was improved by generated knee flexion and decreased pelvic external rotation on level and stairs walking, (3) Decreased vertical excursion of center of mass and pelvic elevation during swing phase was decreased on level, (4) Knee extension moment, hip flexion moment, hip and knee internal rotation moment of non-braced limb were decreased on level walking, (5) Walking speed in 6-minute walk test was increased and physiological cost index was decreased. These findings indicate that 4-bar linkage KAFO compared with ring lock type KAFO is effective in enhancing pattern, endurance, and energy consumption in level surface and stairs walking.

A Study on Developing the Designs of Handle for Personal Locker (개인사물함 손잡이 디자인개발 연구)

  • Cho, Sook-Kyung
    • Journal of the Korea Furniture Society
    • /
    • v.27 no.2
    • /
    • pp.104-110
    • /
    • 2016
  • The aim of this study is to develop and suggest the handle for lockers according to the design process which are used for keeping of student's personal stuffs such as books, writing implements and gym uniform in elementary, middle and high school and university as well. This includes the design development for ILGUMTUR which is specialized for office furniture, but does not own the intellectual property right yet. The design concept based on the domestic locker market survey is recessed handle at low- to intermediate price and it's material should be plastic what is solid and light. The lock system should be constructed by molding process and the name plate can be exchanged every time the owner of locker changes. Contrary to the right angle of it's external appearance, the handle of the locker is designed to be softly round and the simplicity is pursued for an easy production. On the basis of this design concept the sketch has been drawn and upgraded in full by 3D-rendering. Then the mock-up has been completed by 3D printer and ILGUMTUR has obtained a patent for the locking system based on the rotation of 2 circles.