• 제목/요약/키워드: local exhaust ventilation

검색결과 74건 처리시간 0.025초

실내 공기질 개선을 위한 환기기술에 관한 연구 (A Study on the ventilation Technology for Indoor Air Quality Improvement)

  • 장태현;조현욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.540-551
    • /
    • 2005
  • In this research, We'll focus on warm environment and ventilation characteristics when utilizing intake ports, exhaust port and 4-way cassettes for removing heat and polluted air. Four way cassettes have been typical air conditioning units for offices since the multi air-conditioner was introduced. The following installation cases will also be discussed: 1) 4-way cassette's operation without intake ports and exhaust port. 2) Effect of the position of intake port and exhaust ports. 3) cooling air flow, temperature. distribution and local supply index according to the air flow rate from 4-way cassettes.

유해물질 및 공업용 분진 제거를 위한 산업용 후드 개선에 관한 연구 (A Study on Improvement of Industrial Hood in Ventilation System for Elimination of Harmful Material and Dust)

  • 김영선;오율권
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.238-244
    • /
    • 2008
  • This study investigates on the improvement of inhalation effect of hood which attached new device named as "gas-guide-device" in local exhaust ventilation system for the effective elimination of harmful material and dust in manufacturing factory. The gas-guide-device having a diamond shape is composed of width (b) and two sides of a device (X, Y) and its size is selected the industrial hood under application in manufacturing factory after due consideration. In order to investigate the effect of gas-guide-device, numerical and experimental study is performed that the flow velocity is calculated and is measured by a commercial program "COMSOL $Multiphysics^{TM}$" and a hot wire type of anemometer, respectively. The numerical and experimental results are revealed is a similar pattern and flow velocity has improved to hood attached gas-guide-device. Also, the numerical method and result is also verified the dependance. Moreover, the optimum shape and size of gas-guide-device is revealed that the width (b) and the ratio of two sides of gas-guide-device (X, Y) has 125mm and 4 to 6.

경유승용차 도입이 터널 소요환기량에 미치는 영향분석 (The effects of introduction of diesel passenger cars on the ventilation requirements for road tunnels)

  • 김효규;송석헌;김남영;이창우
    • 한국터널지하공간학회 논문집
    • /
    • 제9권3호
    • /
    • pp.309-321
    • /
    • 2007
  • 2005년 하반기부터 국내 승용차시장에 경유승용차의 시판이 허용되면서 시장점유율이 점증하고 있어, 향후 서유럽의 경우와 같은 수준으로 까지도 증가할 것으로 예상된다. 본 연구에서는 경유승용차의 확대보급에 따른 터널 소요환기량 및 환기설비용량 변화를 검토하기 위하여 차령, 차종구성비, 매연 배출량 변화추이를 감안한 기준배출량을 달리하는 3가지 경우를 비교 분석하였다. 전형적인 2km 길이의 2차선 고속도로 터널을 대상으로 한 비교연구에서 현 환기설계기준상의 기준배출량과 경유승용차 구성비 40%를 가정한 Case 1의 경우, 현 설계기준보다 상대적으로 많은 소요환기량 및 환기설비용량을 요구하였다. 차령은 고려하나 경유승용차를 감안하지 않은 기준배출량을 설계에 반영하고 있는 실제 터널을 대상으로 한 Case2와, 차령 및 경유승용차 보급률을 동시에 고려한 배출계수에 의한 기준배출량을 적용한 Case3은 모두 EURO-3 규제기준과 비슷한 수준의 환기특성을 나타내는 것으로 분석되었다. 한편, 국내 기존 환기설계기준에 적용하고 있는 환경부 제작차 허용배출량 기준은 EURO-2 규제기준보다 높은 편으로 조사되었으며, 2006년부터 적용하고 있는 허용배출량 기준은 EURO-4 규제기준과 비슷하게 분석되었다. 본 연구는 향후 국내 경유승용차의 확대보급에 따른 경유차량 구성비의 증가, 매연 배출량 규제에 따른 매연배출량의 감소 등의 변화를 고려한 오염물질의 기준배출량 산정을 통하여 최적 소요환기량 및 환기설비용량 결정을 하기 위한 기초자료의 제공을 목적으로 하고 있다.

  • PDF

바닥의 위치가 Vortex Vent의 배기성능에 미치는 영향 (Effect of the Floor on the Ventilation Performance of the Vortex Vent)

  • 이진원;임영복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.154-158
    • /
    • 2009
  • The vortex ventilation system (VV) which uses a rotating finned swirler installed coaxially with the exhaust duct is a very effective local ventilator. VV can enhance the capture depth by a factor of 3-5 compared to the conventional exhaust hood, in the absence of any solid walls nearby. In real situations there may exist ceiling, side wall and floor, all of which can affect the flow field and suction performance by way of the no-slip condition on the walls. 3D CFD simulation was performed in order to see the effect of the floor on the capture performance of the VV. The presence of floor reduced suction flow velocity, and increased the critical rotational speed which is the rotational speed required for stable vortex formation. Flow velocity profile along the axis could be well approximated by a universal functional form when the distance from the exhaust inlet is non-dimensionalized by the distance to the floor. Capture depth, define by the distance from the exhaust inlet to a point of velocity decreased to 10% of that at the inlet, is reduced by about 10% when the floor distance is 6 times the exhaust hood diameter.

  • PDF

유공성 수평격판을 가진 열원이 있는 밀폐공간내의 온도분포 특성 (Characteristices of Temperature Distribution in a Closed Space with Heat Source and Porous Horizontal Partition)

  • 박찬수;조대환;전철균
    • 한국해양공학회지
    • /
    • 제13권3B호
    • /
    • pp.29-37
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-${\epsilon}$ model was carried out. In the present study, the marine engine room is separated to two floors with porus horizontal partition and considered as a closed space with a heat source and forced ventilation ducts. The porosity of horizontal partition is found to be important. For the engine room with 2 supply ports & 2 exhaust ports, the increasing of the porosity of horizontal partition is effective to reduce the recirculation flow zone in the second floor. When the engine room is ventilated with three supply air ports & one exhaust port, the increasing of the porosity of horizontal partition is effective to reduce the recirculating flow zone in the exhaust air area, but there is a possibility of local extreme heating at the lower side of engine near bottom.

  • PDF

공동주택의 국소배기용 루프팬 성능개선에 관한 연구 (Study on the Performance Improvement of Roof Fan Used for Local Exhaust System Installed in Apartment)

  • 권용일;정열화;안정헌
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.136-141
    • /
    • 2012
  • Performance improvement of local exhaust system used in toilet and cooking place are main concern in a field of ventilation. In Korea, There are many high riser residential apartments in recent years. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depends on stack effect. This study investigates on the performance improvement of terminal device, roof fan, of vertical spiral duct used in high riser residential apartments. This paper focuses mainly on the effect of accessories, number or shape of blades, composed of roof fan with function of exhaust air volume of toilet and cooking place. Roof fan with 10 blades is observed at optimum exhaust performance in this study.

Measurements of Ventilation Effectiveness in an Underfloor Air-Conditioned Space Using a Tracer Gas Technique

  • Han, Hwa-Taik;Seo, S.Y.;Kim, M.H.;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.91-100
    • /
    • 1999
  • This paper investigates ventilation characteristics of an environmental chamber simulating an under-floor air conditioning system for isothermal and cooling supply air conditions. The tracer gas sulfur-hexafluoride (SF$F_6$) was injected into a supply duct using step-up and step-down methods. Local mean and room mean ages were calculated from the concentrations measured at internal points and at the exhaust duct. The air change efficiency of the chamber has been found to be greater in cooling conditions than in isothermal conditions. Also the room air change efficiency is not significantly affected but slightly improved by the presence of a supply diffuser.

  • PDF

기술사 마당 - 주방 후드 부스타 배기 방식

  • 진남기
    • 기술사
    • /
    • 제45권6호
    • /
    • pp.44-51
    • /
    • 2012
  • Local functional, closed the hood and exhaust are classified as open-style hood. Around the closed hood contaminants prevent the spread of contaminants. Surrounded Some pollutants (open-style hood is used in cases where the odor, vapor diffusion, and inferior) of indoor allowed to Hood expressions, which are used for kitchen, laboratory, factory canopy is typical. Contamination that occurs during cooking, kitchen ventilation barrier materials are the biggest problem, its solution by introducing fresh outside air in the kitchen troubleshoot and. Study on the kitchen exhaust airflow for my kitchen, and perform a number of each Institute and at the University of hydrodynamic analysis is investigated.

  • PDF

우리 나라 치과기공사의 직업성 질병과 관련요인에 대한 조사연구 (A Study on the Occupational Diseases of the Dental Technicians and the Related Factors in Korea)

  • 임병철;민경진
    • 보건교육건강증진학회지
    • /
    • 제18권2호
    • /
    • pp.141-156
    • /
    • 2001
  • This study was performed to identify the occupational diseases in the dental technicians working in Korea, and to elucidate the main related affecting factors for the occurrence of the occupational diseases. The research was carried out using a mail questionnaire and data collection was done for two months from April 15, 2000. The questionnaires were delivered to 1000 dental technicians working at 250 dental laboratories which were chosen among the total 1330 dental laboratories in south Korea. And 763 questionnaires were collected, then 739 questionnaires were used for a logistic and a multiple regression analyses. The results obtained in this study are summarized as follows: 1. The occupational diseases in the dental technicians included pneumoconiosis, chronic bronchitis, asthma, pneumonia, hyposmia, allergic dermatitis, eczema, contagious dermatitis, central nervous disorder, dysfunction of finger, vertebral disorder, dysfunction of interphalangeal joint, ophthalmitis, auditory dysfunction, otitismedia, optic trauma, and bum. 2. The main related affecting factors for the occurrence of the occupational diseases in the dental technicians were elucidated as follows: On the ccurrence of chronic bronchitis, vibration of equipment and job career were affected positively. On the ccurrence of asthma, job career and career on current working part were affected positively, but exhaust ventilation, work hour were affected negatively. On the occurrence of eczema, career on current working part and vibration of equipment were affected positively, but personal protective equipment, local exhaust ventilation, isolation of gas source were affected negatively. And eczema was occurred more in methyl methacrylate work than in any other work part. On the occurrence of finger dysfunction, vibration of equipment and noise of work place were affected positively. But personal protective equipment, local exhaust ventilation, isolation of dust and gas source were affected negatively. But finger dysfunction was occurred more in metal polishing than in any other work part. On the occurrence of auditory dysfunction, noise of work place were affected negatively. The results obtained in this study can give a valuable information for a prevention of the occupational diseases in the dental technicians working in Korea, and for keeping them in healthy. This study also can be helpful for a researcher who is aiming at a identification of occupational diseases and a elucidation of related affecting factors in a similar occupation.

  • PDF

시멘트 포장공정에서 환기시스템에 따른 발생분진의 제어 (Control of Suspended Dust in Various Ventilation Systems of Cement Packaging Process)

  • 이승철;김수창;노광철;박명호
    • 한국산학기술학회논문지
    • /
    • 제10권3호
    • /
    • pp.463-469
    • /
    • 2009
  • 시멘트 포장공정에서 발생하는 비산분진을 효율적으로 제거하기 위해 3가지 환기방식(국소배기시스템, 정전식스크러버시스템, 국소급기시스템)을 도입하고 풍량을 변화시키며 총 9가지의 조건에서 실험을 수행하였다. 분진의 농도는 시멘트분진 입자분포 특성을 고려하여 PM2.5, PM10, TSP로 구분하여 측정하였다. 3가지 환기방식에 대한 집진효율을 분석한 결과, 기존의 국소배기시스템과 정전식스크러버시스템이 같이 사용되는 경우 가장 효율적인 것으로 나타났다. 또한 정정식스크러버시스템의 풍량 증가에 따른 입자의 질량농도감소율이 큰 차이가 없는 것을 확인할 수 있었고 이로부터 정정식스크러버시스템을 $2,700m^3/h$ 풍량으로 운전하는 것이 에너지절약 관점에서 효율적인 것이라고 판단되었다. 각 환기방식별 환기성능을 국소배기시스템의 풍량으로 환산한 결과, 대체시스템(정전식스크러버시스템, 국소급기시스템)분진제거성능이 우수한 젓으로 나타났고 정전식스크러버시스템이 국소급기시스템보다 상당히 효율적인 것으로 나타났다. 따라서 기존의 국소배기시스템파 정전식스크러버시스템을 동시에 가동한다면 국소배기시스템의 풍량만을 증가시키는 경우에 비해 반송동력을 줄일 수 있어 분진제거와 에너지절감측면에서 훨씬 효율적이라는 것을 알 수 있었다.