• 제목/요약/키워드: loading rates

검색결과 579건 처리시간 0.032초

A new reconfigurable liquid-metal-antenna-based sensor

  • Zhou, Xiaoping;Fu, Yihui;Zhu, Hantao;Yu, Zihao;Wang, Shanyong
    • Smart Structures and Systems
    • /
    • 제30권4호
    • /
    • pp.353-369
    • /
    • 2022
  • In this paper, a new sensor chip with frequency reconstruction range of 2.252 GHz ~ 2.450 GHz is designed and fabricated. On this basis, a self-designed "T-shaped" shell is added to overcome the disadvantage of uneven deformation of the traditional steel shell, and the range of the sensor chip is expanded to 0 kN ~ 96 kN. The liquid metal antenna is used to carry out a step-by-step loading test, and the relationship between the antenna resonance frequency and the pressure load is analyzed. The results show that there is a good linear relationship between the pressure load and the resonant frequency. Therefore, the liquid metal antenna can be regarded as a pressure sensor. The cyclic loading and unloading experiments of the sensor are carried out, and different loading rates are used to explore the influence on the performance of the sensor. The loading and unloading characteristic curves and the influence characteristic curves of loading rate are plotted. The experimental results show that the sensor has no residual deformation during the cycle of loading and unloading. Moreover, the influence of temperature on the performance of the sensor is studied, and the temperature correction formula is derived.

THE ROLE OF GINSENG DRYING IN THE HARVEST AND POST-HARVEST PRODUCTION SYSTEM FOR AMERICAN GINSENG

  • Bailey W.G.;Dalfsen K.B. van;Guo Y.
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 1993년도 학술대회지
    • /
    • pp.155-163
    • /
    • 1993
  • An American ginseng(Panax quillquefolium L) industry has emerged in British Columbia, Canada over the past ten years. Interest has grown very rapidly and with this development, attention is now moving away from field production issues and emphasis is being directed to enhancements in ginseng storage, drying and processing. There is a dearth of knowledge on these aspects even though they are crucial to international competitiveness. Enhancement dicatates the application of a systems approach to optimizing the harvest and post - harvest production system(crop digging, pre - washing cold storage. washing, drying and post - drying storage). Research in British Columbia to date has focussed on drying and storage issues and has resulted in the design of an enhanced commercial drying system. The role of dryer management, loading rates, airflow rates and pre - drying cold storage on American ginseng root drying rates and root quality were examined. From the dryer management experiments, there are distinct advantages to size sorting root to yield optimum drying rates. If unsorted root is used, efficiency is increased if the trays are systematically rotated. Loading rate experiments illustrate that increasing rates above those currently used in commercial dryers are possible without any sacrifice in quality. This has significant implications for commercial drying. Pre - drying cold storage is a most significant tool for managing drying operations. Over a period of six weeks, no discernable decrease in quality was found as a consequence of cold storage. Further, the moisture loss and the associated root surface changes(loss of surface soil in storage for example) provide new challenges for root quality management. Continued research and technological innovation will be crucial in addressing the demanding challenges of the future.

  • PDF

Adaptive Group Loading and Weighted Loading for MIMO OFDM Systems

  • Shrestha, Robin;Kim, Jae-Moung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제5권11호
    • /
    • pp.1959-1975
    • /
    • 2011
  • Adaptive Bit Loading (ABL) in Multiple-Input Multiple-Output Orthogonal Frequency-Division Multiplexing (MIMO-OFDM) is often used to achieve the desired Bit Error Rate (BER) performance in wireless systems. In this paper, we discuss some of the bit loading algorithms, compare them in terms of the BER performance, and present an effective and concise Adaptive Grouped Loading (AGL) algorithm. Furthermore, we propose a "weight factor" for loading algorithm to converge rapidly to the final solution for various data rate with variable Signal to Noise Ratio (SNR) gaps. In particular, we consider the bit loading in near optimal Singular Value Decomposition (SVD) based MIMO-OFDM system. While using SVD based system, the system requires perfect Channel State Information (CSI) of channel transfer function at the transmitter. This scenario of SVD based system is taken as an ideal case for the comparison of loading algorithms and to show the actual enhancement achievable by our AGL algorithm. Irrespective of the CSI requirement imposed by the mode of the system itself, ABL demands high level of feedback. Grouped Loading (GL) would reduce the feedback requirement depending upon the group size. However, this also leads to considerable degradation in BER performance. In our AGL algorithm, groups are formed with a number of consecutive sub-channels belonging to the same transmit antenna, with individual gains satisfying predefined criteria. Simulation results show that the proposed "weight factor" leads a loading algorithm to rapid convergence for various data rates with variable SNR gap values and AGL requires much lesser CSI compared to GL for the same BER performance.

재하속도가 H-형강 기둥부재의 횡방향 거동에 미치는 영향 (Loading Rate Effect on the Lateral Response of H-Shape Steel Column)

  • 박민석;김철영;한종욱;채윤병
    • 대한토목학회논문집
    • /
    • 제41권6호
    • /
    • pp.637-644
    • /
    • 2021
  • 대부분 동적 성능 평가는 반복 가력 실험을 수행함으로써 구조물의 동적 응답을 평가할 수 있다. 일반적으로 강재는 재하속도 의존성 재료로 알려져 있으며 기둥 부재의 횡방향인 수평방향 가력 시 기둥 부재의 축력인 수직하중이 작용하면 부재의 응답에 영향을 미친다. 하지만, 강재 기둥 구조물의 실험 시 수평 및 수직하중을 동시에 제어하는 것이 어려워 관련 연구는 부족한 실정이다. 본 연구에서는 기둥 부재를 ATS Compensator와 FLB 시스템을 이용하여 수평 및 수직하중을 고속으로 제어하였다. 실험은 H-형 구조용 압연강재인 SS275을 이용하여 수직 하중을 제어하면서 여러 속도로 단조 및 반복 가력 실험을 수행하고 부재의 항복 하중을 비교하였다. 또한, 유한요소해석 시 재하속도에 따라 새로운 항복 응력을 제안하고 수치해석을 통해 비교하였다.

SWRO 전처리 공정에 적용된 DABF 내 Ball Media Filter 성능 평가 (Performance Evaluation of Ball Media Filter in DABF applied to SWRO pretreatment process)

  • 최석호;이정현;박성주;이영근;노형근;김용범
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.567-573
    • /
    • 2019
  • DABF(Dissolve Air Flotation with Ball Filter) is developed as the DAF with the addition of a fiber ball at the lower part of the DAF. The DABF with a capacity of 4,500 ㎥/h was constructed at Gijang SWRO plant in Busan. Since the ball filter has high filtration rate, the loading rate of DABF was designed from 20 to 42 ㎥/h/㎡. When one DABF basin is in the back washing mode, the loading rate of other two DABF basins is increased to 42 ㎥/h/㎡. Turbidity at the BF outlet in DABF is <2 NTU at turbidity of 5-10 NTU at the BF inlet. If there is no algae bloom and turbidity is low in raw seawater, only BF in DABF is operated and meets <2 NTU at the BF outlet. Even if BF is operated at high hydraulic loading rates, no significant differential pressure increases and reduction in the turbidity removal rate is minimal in a day. Thus, DABF is the pre-treatment technology that provides stable water quality even with BF onlyoperation without DAF operation. Compared with the DAF, DABF requires additional facilities such as valves, piping, and drainage systems for backwashing the BF. But in terms of footprint and operating costs, DABF has more advantages than DAF. With DABF application, the load of the downstream filtration equipment is decreased so that the capacity of the filtration equipment can be reduced. Also, if the downstream filtration equipment is to be maintained the same regardless of DABF, the operating cost of DABF is less than DAF.

Automatic Control Of Dissolved Oxygen In Activated Sludge Aeration Tank

  • Park, Kwang-Soo;Heo, Nam-Hyo;Lee, Hae-Goon;Han, Gee-Baek;Kim, Chang-Won
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제3권2호
    • /
    • pp.113-119
    • /
    • 1999
  • The quality of the effluent from an activated sludge aeration tank can deteriorate when the substrate removal rate decreases due to an abrupt reduction in the DO concentration, which is affected by such operating conditions as the loading rate, temperature, wastewater composition, and so on. In this research, a DO control system that includes a PI (proportional-integral) controller/Hiraoka controller was developed and applied to a pilot-scale activated sludge process, then its acceptability was estimated. The applicability of the respiration rate to DO control was also estimated. The respiration rate indicated a variety of input organic loading rates, which is the main disturbance to the DO concentration in an aeration tank. When the influent concentration incrementally decreased and increased between CODcr 1,000 mg/l and 100 mg/l, the control system with a PI controller exhibited a good llperformance-the average DO concentrations were 2.00$\pm$0.14 mg/l and 1.88$\pm$0.15 mg/l (set value was 2.0 mg/l), respectively, and the settling time was just 10 minites. When the control system was operated for 4 days, the DO concentration was 1.99$\pm$0.18 mg/l and 32.6% of the air flowrate was saved. However, the fluctuations in the respiration rates and air flowrates were severe, which could be harmful to the stability of the biomass and mechanical stability of the blower. A possible approach to solve this problem may be the simultaneous control of the loading rate and DO concentration.

  • PDF

유입원수 조류제거를 위한 high rate DAF 최적화 연구 (High Rate Dissolved Air Flotation (DAF) for the Removal of Algae Species)

  • 정우식;안주석;송근원;오현제
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.415-419
    • /
    • 2017
  • In recent years there have been large increases in the hydraulic loading rates used to design dissolved air flotation (DAF) facilities for drinking water applications. High rate DAF processes are now available at loading rates of 20 to $40m^3/m^2{\cdot}h$. This research evaluated dissolved air flotation as a separation method for algae and organic compounds from water treatment plants. During the service period of 2016. 5. to 2017. 6., DAF pilot plants ($500m^3/day$) process has shown a constantly sound performance for the treatment of raw water, yielding a significantly low level of turbidity (DAF treated water, 0.21~1.56 NTU). As a result of analyzing the algae cell counts in the influent source, it was expressed at 100-120 cells/mL. In DAF treated water, the removal efficient of alge cell counts was found to be upto 90%. The stable turbidity and algae removal were confirmed by operating the high rate DAF process under the condition of the surface loading rate of $30m^3/m^2{\cdot}hr$.

Optimal Metal Dose of Alternative Cathode Catalyst Considering Organic Substances in Single Chamber Microbial Fuel Cells

  • Nam, Joo-Youn;Moon, Chungman;Jeong, Emma;Lee, Won-Tae;Shin, Hang-Sik;Kim, Hyun-Woo
    • Environmental Engineering Research
    • /
    • 제18권3호
    • /
    • pp.145-150
    • /
    • 2013
  • Optimal preparation guidelines of a cathode catalyst layer by non-precious metal catalysts were evaluated based on electrochemical performance in single-chamber microbial fuel cells (MFCs). Experiments for catalyst loading rate revealed that iron(II) phthalocyanine (FePc) can be a promising alternative, comparable to platinum (Pt) and cobalt tetramethoxyphenylporphyrin (CoTMPP), including effects of substrate concentration. Results showed that using an optimal FePc loading of $1mg/cm^2$ was equivalent to a Pt loading of $0.35mg/cm^2$ on the basis of maximum power density. Given higher loading rates or substrate concentrations, FePc proved to be a better alternative for Pt than CoTMPP. Under the optimal loading rate, it was further revealed that 40 wt% of FePc to carbon support allowed for the best power generation. These results suggest that proper control of the non-precious metal catalyst layer and substrate concentration are highly interrelated, and reveal how those combinations promote the economic power generation of single-chamber MFCs.

비행하중에서 피로균열진전에 미치는 미소하중의 영향 (The Effect of Low-amplitude Cycles in Flight-simulation Loading)

  • 심동석;김정규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1045-1050
    • /
    • 2003
  • In this study, to investigate the effects of omitting low-amplitude cycles from a flight-simulation loading, crack growth tests are conducted on 2124-T851 aluminum alloy specimens. Three test spectra are generated by omitting small load ranges as counted by the rain-flow count method. The crack growth test results are compared with the data obtained from the flight-simulation loading. The experimental results show that omission of the load ranges below 5% of the maximum load does not significantly affect crack growth behavior, because these are below the initial stress intensity factor range. However, in the case of omitting the load ranges below 15% of the maximum load, crack growth rates decrease, and therefore crack growth curve deviates from the crack growth data under the flight-simulation loading. To optimize the load range that can be omitted, crack growth curves are simulated by the stochastic crack growth model. The prediction shows that the omission level can be extended to 8% of the maximum load and test time can be reduced by 59%.

  • PDF

강우시 저농도 고수리부하가 회분식 반응조 제거효율에 미치는 영향 (Effects of Inflow Fluctuation on the Removal Efficiency in Low Strength Sewage Treatment using Sequencing Batch Reactor Process during Rainfall)

  • 어성욱;김건하;손봉호
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.91-96
    • /
    • 2006
  • Many small scale Sewage Treatment Plants (STPs) are currently being constructed at many rural areas. The STPs in rural area suffer from low concentration and large inflow quantity fluctuation during wet weather mainly due to illicit combined sewer system. Sequencing Batch Reactor (SBR) is a process effectively coping with these obstacles. The main objective of this study was to evaluate SBR with high hydraulic loading and low inflow concentration. The operating conditions tested were: organic loading rate = $0.17-0.42KgBOD/m^3/d$, hydraulic loadings = $12.1-61.5m^3/m^2/d$, average MLSS concentration = 2500 mg/L, F/M ratio = 0.026-0.17 KgBOD/Kg MLSS, HRT = 9-12 hr HRT, and SRT = 5.6-33.6 days. Organic loading rate on SBR did not impact significantly on BOD and SS removal efficiencies. To increase treatment efficiencies, low hydraulic loading rate with low concentration was required. The results suggested that low influent concentration with high inflow rates during wet weather requires extended time for settling.